Search NASA⌕ Search

SEARCH · Search NASA

Results for “TRADE OFF ANALYSIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Optimal Design and Techno-Economic Analysis of 3D-Printed, Intensified Packings for Absorbers and Strippers in Solvent-Based CO 2 Capture

A potential technology for the CO 2 absorption process is utilizing intensified structured packing with embedded cooling/heating channels for continuous heat exchange, which can overcome limitations of discrete methods, such as discrete intercooling and centralized reboilers, to aid in reducing energy consumption and decreasing costs. This work investigates the modeling of intensified packing (IP) for the stripper tower, extending on previous work for the absorber, which distributes heat internally within the column, improving the thermodynamics for the solvent regeneration process. The model includes submodels for steam turbine extraction to produce steam at various qualities as well as a surrogate model for calculating steam enthalpy. A cost model for a plant-scale absorption capture process was developed, allowing for the design of the plant to be optimized, subject to minimizing capture cost using two different power plant flue gas sources. In this optimization, the placement of IP in both towers is optimized to balance the trade-off between enhanced heat transfer and reduced mass transfer volume. For natural gas combined cycle flue gas, the standard process configuration had a minimum cost of $\$$65.40/tonne CO 2 , and considering IP, the minimum capture cost is reduced to $\$$62.73/tonne, with utilization in the stripper column, which reduces yearly costs by up to $\$$2.67 MM/yr. Cooling the absorber through IP, or intercoolers, was only found to be beneficial at higher capture rates, with IP in both towers having a cost of capture of $\$$68.08/tonne at 99.9% capture, a reduction of $\$$12.64/tonne when using only intercoolers at the same capture rate. When capturing from pulverized-coal power plants, the minimum cost of capture when using IP in both towers is $\$$44.18/tonne (at 97% capture), while the standard configuration with and without intercoolers was $\$$45.69 and $\$$47.22 per tonne, respectively. This results in a reduction in yearly costs of $\$$16.98 MM/yr from the base-case configuration. At this higher CO 2 concentration, cooling in the absorber from the IP becomes extremely beneficial, reducing energy consumption by up to 6%.

20 FOSSIL-FUELED POWER PLANTS↗

Analysis and Benchmarking of feature reduction for classification under computational constraints

Abstract Machine learning is most often expensive in terms of computational and memory costs due to training with large volumes of data. Current computational limitations of many computing systems motivate us to investigate practical approaches, such as feature selection and reduction, to reduce the time and memory costs while not sacrificing the accuracy of classification algorithms. In this work, we carefully review, analyze, and identify the feature reduction methods that have low costs/overheads in terms of time and memory. Then, we evaluate the identified reduction methods in terms of their impact on the accuracy, precision, time, and memory costs of traditional classification algorithms. Specifically, we focus on the least resource intensive feature reduction methods that are available in Scikit-Learn library. Since our goal is to identify the best performing low-cost reduction methods, we do not consider complex expensive reduction algorithms in this study. In our evaluation, we find that at quadratic-scale feature reduction, the classification algorithms achieve the best trade-off among competitive performance metrics. Results show that the overall training times are reduced 61%, the model sizes are reduced 6×, and accuracy scores increase 25% compared to the baselines on average with quadratic scale reduction.

97 MATHEMATICS AND COMPUTING↗

Providing Levelized Cost and Waiting Time Inputs for HDV Hydrogen Refueling Station Planning: A Case Study of U.S. I-75 Corridor

Widespread use of diesel fuels in freight transportation leads to greenhouse gas (GHG) emissions that play an important role in air pollution. The air pollution, as well as the energy crisis, drives the transition from diesel fuel to cleaner and more energy-efficient fuels such as hydrogen fuels. With such a transition, the strategic planning and optimization of supporting refueling infrastructure along the national highway for heavy-duty vehicles (HDVs) become a necessity. Cost and service level are two essential factors to be considered in hydrogen refueling station location and capacity optimization. The service level in this study is assessed by the delay (waiting time) at fueling stations as well as the fueling demand fulfilled. To this end, this study presents a methodology to provide waiting time (delay) and levelized hydrogen fuel cost inputs under different station configurations (number of dispensers and fill rates) for hydrogen refueling station planning. Determining the station configurations based on the trade-off between the two inputs is further discussed. Particularly, this study points out that the levelized cost and waiting time are affected by hourly demand patterns and estimates the two inputs under different peak hour fueling demand scenarios. The results suggest that, with the same daily demand, the cost, as well as the waiting time, increases obviously with the peak hour demand. In the case study, the cost grows at least 30% when the peak hour visit frequency of the daily total visits increases from 5% (evenly distributed pattern) to 10% (the most common pattern for existing diesel fueling stations along I-75). Accounting for this peak hour effect in hydrogen refueling station planning is recommended. Overall, the waiting time model and cost analysis provide key inputs for optimizing hydrogen refueling station location and configurations based on anticipated refueling demand patterns. The paper is the second in a series that aims to build a comprehensive modeling plan and optimize hydrogen refueling infrastructure along the Interstate 75 (I-75) corridor for HDVs.

Liu, Yuandong↗

Co-Location of Cellulosic Bioethanol and Alcohol-to-Jet (ATJ) Production Facilities for Targeted Scale-Up of Sustainable Aviation Fuel (SAF) Production

Achieving aerospace industry net-zero emissions by 2050 requires rapid scaling of sustainable aviation fuel (SAF) production. Leveraging existing infrastructure, proven technologies like Alcohol-to-Jet (ATJ), and low carbon intensity (CI) feedstocks (e.g., switchgrass and miscanthus) can support this transition and help achieve near-term emissions reduction targets. This study evaluates the implications of lignocellulosic ethanol biorefinery siting and integration with petroleum refineries to produce SAF across 1000 sites randomly sampled from areas suitable for perennial grasses in the U.S. rainfed region. To better understand the logistics of material transport and handoffs, we integrated models of biomass harvest, transport, ethanol, and ATJ production in a stochastic framework based on Monte Carlo simulations to characterize SAF minimum selling price (MSP) and carbon intensity (CI), considering site-specific parameters (e.g., feedstock production, transportation, taxes, incentives). The results indicate trade-offs between MSP and CI across locations, with median MSP ranging from 7.9 to 12.8 USD·gal −1 and CI from −9.7 to 39.4 gCO 2 e·MJ −1 . Despite high estimated decarbonization costs (580 USD·tonCO 2 e −1 ), our results indicate that site-specific deployment of ATJ with low-CI feedstocks can improve sustainability outcomes. The framework provides a systematic approach to assess cost and sustainability trade-offs across locations, considering the end-to-end supply chain and supporting an informed investment in SAF production.

09 BIOMASS FUELS↗

Montage electron tomography of vitrified specimens

Cryo-electron tomography provides detailed views of macromolecules in situ. However, imaging a large field of view to provide more cellular context requires reducing magnification during data collection, which in turn restricts the resolution. To circumvent this trade-off between field of view and resolution, we have developed a montage data collection scheme that uniformly distributes the dose throughout the specimen. In this approach, sets of slightly overlapping circular tiles are collected at high magnification and stitched to form a composite projection image at each tilt angle. These montage tilt-series are then reconstructed into massive tomograms with a small pixel size but a large field of view. For proof-of-principle, we applied this method to the thin edge of HeLa cells. Thon rings to better than 10 Å were detected in the montaged tilt-series, and diverse cellular features were observed in the resulting tomograms. These results indicate that the additional dose required by this technique is not prohibitive to performing structural analysis to intermediate resolution across a large field of view. We anticipate that montage tomography will prove particularly useful for lamellae, increase the likelihood of imaging rare cellular events, and facilitate visual proteomics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technology Demonstration of a High-Pressure Swirl Oxy-Coal Combustor

This technical report presents the exploration of the design and prototyping of a High-Pressure Swirl Oxy-coal Combustor. Pressurized oxy-coal combustion systems have the potential to improve efficiency along with an increased carbon capture rate. Reduction of flue gas at higher pressure, smaller system size, and capital cost reductions render high-pressure oxy-coal systems particularly attractive as next-generation energy-producing systems. High-pressure oxy-coal combustion systems are a recent concept, and thus operability issues of combustor designs for such systems are not fully understood. Significant challenges exist to maintain oxy-coal combustion stability at elevated pressure and a high CO 2 diluent environment. Although a body of knowledge exists for high-pressure oxygen combustion in rocket engines (or similar applications), it is yet to be strategized how these fundamental concepts can be translated to low-temperature CO 2 diluent combustion regimes. The realization of the pressurized oxy-coal based systems requires combustor components to be designed and demonstrated for an operating pressure over 10 bar. However, pressurized oxy-coal combustor design information at this pressure range and scale relevant to validate those proposed systems is currently limited. Experimental data from MWth scale oxy-coal combustors are needed to identify the optimal trade-off between net efficiency and systems size. The proposed effort is aimed at demonstrating a 1 MWth down-fired swirl Oxy-Coal combustor and investigate the interrelation between combustor operating conditions (pressure; flame stability; flue gas recirculation ratio) and conversion efficiencies to minimize oxygen requirements. One of the key challenges is to configure burner design (i.e., swirl number and injector) and operating conditions for high-pressure oxy-coal combustion systems. These experiments differ from current systems partly due to the high theoretical flame temperature and related burner operability issues associated with oxy-combustion. An ASPEN PLUS® model study for 550 MWe TIPS and ENEL pressurized oxy-coal systems with CO 2 recirculation was performed to evaluate system design, subsystems sizing, and operating condition determination. The system analysis effort included TRL and technology gap determination of subsystems and critical components. This information was scaled to develop design requirements (design pressure and flue gas recirculation: RR Flue Gas = $\frac{m_{flue}}{m_{total}}$) for the 1 MWth combustor. The effects of a wide range of carbon dioxide recirculation ratios on the thermal efficiency of ENEL and TIPS cycles are studied. The pressure of 10 bar and 80 bar are used for ENEL and TIPS cycles, respectively. The thermal efficiency of ENEL is significantly higher than the efficiency of TIPS at a pressure of less than 10 bar. The insights from system analysis were then used to design a 1 MWth swirl oxy-coal combustor. Flame temperature analysis and material strength analysis was performed to determine the combustor thickness. The structural integrity of the combustor was validated by finite element analysis using Abacus® and Hypermesh®. Feasibility of igniters and secondary burners are investigated in successful high-pressure oxy-methane combustion. The secondary burners are designed in such a way that it can operate between 100 to 500 kW firing input. Three generations of the pintle injector were designed based on swirl numbers (S=0, 0.9, and 1.2). Key pintle injector parameters such as pintle size, pintle orifice size, spray pattern were investigated by cold flow tests. Information from these tests was used to modify injector design for smooth and successful operation. A 5 mm pintle orifice size was decided upon as the optimum size for oxy-coal operation for the combustor. Shadow sizing experiments were performed to identify the atomization rate of each injector. Different coal water slurry mixtures (30 – 50% coal by wt% in the mixture) at various total momentum ratios (TMR) were investigated for this purpose. These experiments provided decisive information to choose the best design of the injector. The injector with 1.2 swirl provided higher atomization in all cases than other designs. The mean equivalent droplet size of the jet was similar at different TMR and mixture ratios using this injector, thus making it suitable for use in most cases. Therefore, the 1.2 swirl-pintle injector was chosen for the shakedown test. The combustor and other sub-systems, including feed systems and control and data acquisition, have been manufactured, assembled, and integrated. The total system integration and installation began on July 1, 2020. The shake-down tests and initial operational capability demonstration are expected to be completed by September 30, 2020.

01 COAL, LIGNITE, AND PEAT↗

Time Series Dimension Reduction for Surrogate Models of Port Scanning Cyber Emulations

Surrogate model development is a key resource in the scientific modeling community for providing computational expedience when simulating complex systems without loss of great fidelity. The initial step to development of a surrogate model is identification of the primary governing components of the system. Principal component analysis (PCA) is a widely used data science technique that provides inspection of such driving factors, when the objective for modeling is to capture the greatest sources of variance inherent to a dataset. Although an efficient linear dimension reduction tool, PCA makes the fundamental assumption that the data is continuous and normally distributed. Thus, it provides ideal performance when these conditions are met. In the case for which cyber emulations provide realizations of a port scanning scenario, the data to be modeled follows a discrete time series function comprised of monotonically increasing piece-wise constant steps. The sources of variance are related to the timing and magnitude of these steps. Therefore, we consider using XPCA, an extension to PCA for continuous and discrete random variates. This report provides the documentation of the trade-offs between the PCA and XPCA linear dimension reduction algorithms, for the intended purpose to identify key components of greatest variance in our time series data. These components will ultimately provide the basis for future surrogate models of port scanning cyber emulations.

97 MATHEMATICS AND COMPUTING↗

The Cost and Benefit of Enhancing Cybersecurity for Hybrid AC/DC Grids

As critical interfaces of AC grids and DC grids inside a hybrid AC/DC grid, the voltage-sourced-converter (VSC) has been demonstrated to be vulnerable to false data injection (FDI) cyber-attacks. As a result, the cyber-attack-induced AC grid frequency deviations and DC grid voltage deviations threaten the secure operation. Here, to enhance cybersecurity in a not only feasible but also cost-effective manner, this paper proposes a cost-benefit-based cyber-defense strategy for a hybrid AC/DC grid. First, this paper establishes a spatial-temporal dual cyber-attack evaluation model, in which the cyber-attack-induced frequency and voltage deviations are modelled in both a spatially and temporally dual manner. Then, the proposed cost-benefit-based cyber-defense strategy is modelled as a VSC commitment problem to achieve the trade-off between maximizing the cyber-defense benefits and minimizing the cyber-defense costs. The VSC commitment problem is then mathematically convexified into a mixed-integer second-order cone programming (MISOCP) problem, which could be efficiently solved in an event-triggered manner against unfolding cyber-attack events. Simulation results on a test hybrid AC/DC grid verified the feasibility and the cost-effectiveness of the proposed cyber-defense strategy.

cost-benefit analysis↗

Integration of a Concentrating Solar Steam Topping Turbine to an Existing Geothermal Binary Power Plant (CRADA CRD-17-700 Final Report)

U.S. Geothermal Inc. is a publicly traded leading renewable energy company focused on the development, production, and sale of electricity from geothermal energy with operating generation facilities at Raft River, Idaho; San Emidio, Nevada; and Neal Hot Springs, Oregon. (U.S. Geothermal was acquired by Ormat Technologies, Inc. since the execution of this project). This project will evaluate the integration of a concentrating solar steam topping cycle with a geothermal bottoming binary cycle. This hybrid plant configuration will enable high efficiency conversion of the solar heat to electrical power, while simultaneously increasing the power output of the bottoming cycle. Such a design has the potential to reduce the cost of electrical power from concentrating solar power (CSP) and geothermal plants, and a viable design could be deployed at existing geothermal plants that have experienced resource productivity decline as well as in greenfield projects. This analysis will examine US Geothermal’s Raft River power plant for implementation of this concept. INL and NREL have previously collaborated in the analysis of geo-solar hybrid power plants. These two labs will again work together to model the solar field, steam-topping, and geothermal bottoming cycles in order to investigate the performance of the proposed cycle. This analysis will provide US Geothermal with technical information including equipment specifications and estimated power generation necessary to advance the concept toward implementation. A successful project outcome has two parts: One would be for US Geothermal to have a process flow diagram (heat and mass balance), and performance parameters for the major pieces of equipment. US Geothermal could then use this information evaluate the techno-economic feasibility of the hybrid power cycle, and serve as the basis for subsequent detailed equipment design, purchase, and installation of the cycle. The second would be for the developed solution to be published by DOE for use by other geothermal developers both to retrofit underperforming plants and to lower the LCOE of new developments.

15 GEOTHERMAL ENERGY↗

Optimizing fluvial flood mitigation strategies: A multi-objective approach for cost-effective and socially-aware infrastructure feasibility analysis

Effective levee planning must balance capital cost, risk reduction, and community priorities. These objectives are rarely optimized together. This study presents a feasibility phase, simulationin-the-loop framework that couples terrain-based flood modeling with a socially aware multiobjective optimizer. Flood risk is measured as Expected Annual Exposed Population (EAEP), obtained by integrating exposure over Annual Exceedance Probability (AEP) nodes, mirroring the Hydrologic Engineering Center's Flood Damage Reduction Analysis (HEC-FDA) expected-annual formulation but with people rather than dollars. Exposure per scenario is computed by overlaying binary inundation masks with a population surface at the tract level. Distributional fairness is encoded through a Group Benefit Share (GBS) constraint that requires high-SVI tracts to receive at least a baseline share of annualized benefits. Capital cost is represented by a height-dependent unit-cost model suitable for screening. This study addresses the two-objective problem, minimize cost and expected annual exposure subject to the GBS constraint, using Non-Dominated Sorting Genetic Algorithm II (NSGA-II) and leveraging Pareto front for feasibility phase decision making. Implemented with terrain-based flood modeling, GeoFlood, for rapid scenario evaluation, the framework is demonstrated in Southeast Texas. The results reveal clear trade-offs among cost, risk, and social benefits and identify non-dominated levee height configurations that satisfy the benefit-share floor. The contributions are a scalable decision support method that operationalizes expected annual population-based risk, embeds enforceable benefit-sharing guarantees, and uses lightweight simulation to explore large design spaces before higher fidelity design stages.

Flood mitigation↗

Stakeholder-driven carbon neutral pathways for Thailand and Bangkok: integrated assessment modeling to inform multilevel climate governance

Thailand has established a target of carbon neutrality by 2050. Reaching this goal will require coordination and collaboration between stakeholders spanning sectors and scales, including energy system decision makers, land managers, and city planners. Robust decarbonization scenarios incorporating current plans and targets, additional measures needed, and trade-offs between strategies can help stakeholders make informed decisions in the face of uncertainty. Through iterative engagement with decision makers at the city and national levels, we develop and analyze carbon neutral scenarios for Thailand that incorporate Bangkok’s role using a global integrated assessment model. We find that Thailand can reach carbon neutrality through power sector decarbonization, energy efficiency improvements, widespread electrification, and advanced technologies including carbon capture and storage and hydrogen. Negative emissions technologies will also be needed to offset Thailand and Bangkok’s hardest-to-abate CO 2 emissions. Bangkok, as a major population and economic center, contributes significantly to Thailand’s energy demand and emissions and can therefore play an important role in climate change mitigation. Accordingly, our results underscore the importance of subnational climate action in meeting Thailand’s carbon neutral goal. Our analysis also indicates that without sustained land-based carbon sequestration, much more mitigation effort will be needed in Thailand’s energy sector, including at the subnational scale, to reach carbon neutrality. These insights can help stakeholders identify priorities, consider tradeoffs, and make decisions that will impact Bangkok and Thailand’s long-term climate change mitigation potential. This analysis demonstrates how stakeholder engagement in integrated assessment modeling can facilitate and inform multilevel climate governance.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Financial-technical co-design for capital-intensive, resource-responsive energy systems

Because of their capital-intensive operation, wind energy systems that are competitive in terms of the cost of the energy that they produce lead to risk-reward trade-offs that make their business cases less favorable than those of conventional energy generation technologies. However, wind energy systems tend to be designed to maximize energy production or minimize cost of energy rather than to maximize their business cases. In this work, we attempt to exploit designs specifically tailored to business cases. We develop a novel framework for analyzing energy systems that ties their design variables to monthly operating incomes using simple models and historical hourly market and resource data. Using this approach, we demonstrate that for a wind site with abundant wind resource in the California Independent System Operator market, we can control the trade-off between mean and 5th percentile monthly returns by choosing the specific power of the turbine at a fixed modeled initial capital cost. Our framework gives a measure of the risk-reward spectrum of energy generation assets that could be built at a given site with respect to the sub-annual resource/market variation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Aggregation in bottom-up vulnerability assessments and equity implications: The case of Jordanian households’ water supply

Bottom-up methods for water resources modeling rely on acceptability thresholds to find, through a response surface, which deeply uncertain futures lead to system failure. They commonly treat water users as aggregate actors, which may preclude analysis of the equity impacts of interventions. This paper explores how aggregation choices for large groups of water users lead to different policy recommendations in response surface assessments. Herein, two aggregation methods with varying parameters are considered: percentile satisfaction targets and generalized mean. A 2-dimensional stress-test assessment across groundwater availability and population is applied to household water supply in Jordan. The study compares six different policies covering supply enhancement and rebalancing, using a country-wide multi-agent model that characterizes households across socioeconomic strata. For different aggregation levels, policies are ordered by their associated robustness index. Results show that aggregation choices may modify response surfaces as much as policy changes and strongly determine policy preference. Modifying allocation rules can substantially reduce the disparity in household vulnerability. Preferences defined by aggregation intervals provide a finer understanding of trade-offs among water users and may improve deliberation over equity under deep uncertainty.

54 ENVIRONMENTAL SCIENCES↗

Climate-Driven Divergence in Biophysical and Economic Impacts of Agrivoltaics

Increasing global demands for food and energy necessitate innovative land-use solutions. Agrivoltaics, colocating solar photovoltaics with agriculture, shows promise, but its widespread adoption faces complex biophysical and economic trade-offs in a changing climate. Here, we develop an integrated biophysical-economic modeling framework to quantify how agrivoltaics affect biophysical and economic impacts across the Midwestern United States under both current and project climate conditions. We find strong regional divergences driven by climate gradients. In the humid eastern Midwest, solar panel shading limits photosynthesis, leading to reduced yields (maize -24%; soybean -16%) and lower farmers' profitability (maize -16%; soybean -2%) compared to conventional agriculture. Conversely, in the semiarid western region, shading alleviates heat and water stress, moderating yield reductions for maize (-12%) and even boosting soybean yields (+6%), resulting in improved economic returns (-6% for maize; +9% for soybean), for a scenario with 33% photovoltaic ground coverage ratio. Although agrivoltaics generate substantial electrical energy across all regions, high upfront installation costs challenge solar developers compared to standalone solar photovoltaics. However, our analysis identifies “win-win” opportunities where soybean-based agrivoltaics in the semiarid region produce economic benefits for both farmers and solar developers, highlighting the necessity for region-specific designs tailored to local climate conditions. Critically, future climate projections indicate eastward expansion of semiarid conditions, broadening areas where agrivoltaics can mitigate crop yield penalties (even boosting yield) and improve overall profitability, especially under high-emission scenarios. The results provide a mechanistic and economically integrated understanding essential for developing evidence-based and region-specific strategies to scale agrivoltaics in a changing climate.

14 SOLAR ENERGY↗

Assess The Water Resistance And Thermal Performance Of Pre-flashing Methods When Adding Continuous Insulation During Re-siding (AIRS)

Retrofitting existing buildings by adding continuous insulation during re-siding projects has become a popular method for enhancing energy efficiency, especially given the aging building stock and stricter energy codes. When properly integrated with existing window systems, continuous insulation can significantly improve thermal performance, but it also presents challenges related to water resistance and building envelope integrity. Research indicates that the interface between windows and wall assemblies is critical as improper installation or sealing can lead to water intrusion, materials deterioration, and energy loss. Moreover, studies show that fully integrating the windows with the insulation layer can reduce window heat loss by up to 40%, emphasizing the importance of optimizing window placement and sealing during retrofitting to ensure both energy efficiency and structural performance. In this study, we conducted experimental tests to evaluate the water penetration and thermal performance of two window types: an aluminum window with a 2-inch installation fin and a wood window, representing typical mid-20th century designs. Using the Heat, Air, and Humidity (HAM) chamber at Oak Ridge National Laboratory (ORNL), we assessed bulk water penetration and performed COMSOL analysis for thermal flux and examined the effectiveness of different pre-flashing methods, i.e., standard self-adhered flashing tape and high-performance flashing tape with low-expansion foam, to enhance water resistance. The results indicate that applying proper flashing techniques and moisture management strategies can mitigate these risks, improving the overall performance and durability of retrofitted buildings. Additionally, proper sealing during retrofitting is essential, as improper installation can lead to moisture issues that compromise both energy efficiency and structural integrity.

Shen, Zhenglai [ORNL]↗

Chain Flexibility and Structure of a Polyimide Copolymer: Revisiting the Freely Rotating Chain Model

Poly(4–4′-oxydiphenylene-pyromellitimide)-based polyimides─trade name Kapton─have wide-ranging engineering applications owing to their thermal and mechanical stability, but little is known about underlying chain-level characteristics. While theoretical models have conceptualized Kapton as inflexible polycyclic rods separated by freely rotating diphenyl ether hinge groups, the model’s core predictions remain untested and subtleties of the relaxation behavior are missed, which atomistic modeling can resolve. To these ends, we examine all-atom Kapton structures in crystalline and glassy amorphous configurations using a DFT-validated class II force field. Constructing amorphous configurations is challenging, as the fused-ring-containing backbone has slow relaxation dynamics and scaling suggestive of entanglements even in oligomers. In conclusion, we find larger backbone rearrangements of the linear polycyclic segments about ether groups that are consistent with the rod-hinge picture on the monomer scale, whereas a ring rotation analysis suggests partially flexible rod-like segments and involves multiple facile rotational relaxation modes.

Liesen, Nicholas T. [Lawrence Livermore National L↗

Analysis and Optimization of Seismo-Acoustic Monitoring Networks with Bayesian Optimal Experimental Design

The Bayesian optimal experimental design (OED) problem seeks to identify data, sensor configurations, or experiments which can optimally reduce uncertainty. The goal of OED is to find an experiment that maximizes the expected information gain (EIG) about quantities of interest given prior knowledge about expected data. Therefore, within the context of seismic monitoring, we can use Bayesian OED to configure sensor networks by choosing sensor locations, types, and fidelity in order to improve our ability to identify and locate seismic sources. In this work, we develop the framework necessary to use Bayesian OED to optimize the ability to locate seismic events from arrival time data of detected seismic phases. In order to do utilize Bayesian OED we must develop four elements:1. A likelihood function that describes the uncertainty of detection and travel times; 2. A Bayesian solver that takes a prior and likelihood to identify the posterior; 3. An algorithm to compute EIG; and, 4. An optimizer that finds a sensor network which maximizes EIG. Once we have developed this framework, we can explore many relevant questions to monitoring such as: how and what multiphenomenology data can be used to optimally reduce uncertainty, how to trade off sensor fidelity and earth model uncertainty, and how sensor types, number, and locations influence uncertainty

47 OTHER INSTRUMENTATION↗

Opportunities to Expand Building Efficiency Programming at Community Colleges

According to the most recent U.S. Energy and Employment Report, more than 2.3 million workers in the United States are involved in activities that reduce energy usage in buildings. This workforce supports energy efficiency from the design of buildings and their systems through the manufacturing and trade of components and supplies involved in these systems to the installation, repair, and maintenance of these systems. Less than 10% of the workers in key building efficiency occupations have a bachelor’s or higher degree, compared to ~40% of the general workforce. Thus, the community college system is a key stakeholder in training and educating a large portion of the building efficiency workforce. Despite this, the literature review conducted for this report found almost no research focused on better understanding and supporting the role of community colleges as they train this workforce at scale. This report seeks to understand how and to what extent building efficiency and advanced building technology concepts are being addressed in community colleges as well as potential pathways for schools to consider to better prepare students to enter the building efficiency industry. The first section presents information from a literature review and data analysis to provide background on the building efficiency workforce, the types of building efficiency training and education available from community colleges, and the barriers and challenges that exist in the workforce. The second section offers a series of case studies that illustrate the various ways that building efficiency content can be addressed at community colleges. The final section provides an overview of the opportunities available to community colleges as well as considerations for schools that want to increase building efficiency programming.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗