Search NASA⌕ Search

SEARCH · Search NASA

Results for “TUBING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Lava tubes and channels in the Lunar Marius Hills.

The Marius Hills region, a volcanic plateau in Oceanus Procellarum, contains numerous rilles, rille-like structures, and chains of elongate craters. Most of these structures characteristically: (1) originate on or near irregular shaped craters associated with features previously interpreted as volcanic domes, (2) trend downslope onto Plateau Plains, (3) generally taper in width and become shallower, (4) are often discontinuous, (5) occupy the center, or apparent crest of a broad ridge, (6) may contain cut-off branches and distributary structures, and (7) may have local reversals in longitudinal slope. Structures having these characteristics are interpreted to be lava channels or partly collapsed lava tubes. Terrestrial lava tubes form exclusively, and commonly, in fluid basalt flows. Recent evidence indicates that viscosities of lunar mare 'basalt' lava flows were conducive for lava tube formation. Terrestrial analogs are offered for structures described in the Marius Hills.

Greeley, R.↗

Observations of actively forming lava tubes and associated structures, Hawaii.

Fluid basalts were erupted in August, 1970, from a vent near Alae Crater and flowed southeast. Forming exclusively in pahoehoe basalt, tubes in general evolve from lava channels by crustal formation, although some tubes develop directly from the vent. The observation discussed shows that channel crusts and tube roofs form in several ways. Lava channels usually form along the axis of highest velocity within the flow and are often centered along older lava channels, stream beds, rifts, grabens, or fracture zones.

Greeley, R.↗

The shock tube in spectroscopy and astrophysics.

The role of shock-tube spectroscopy in laboratory astrophysics is discussed, with special emphasis on the effectiveness of the hook method for quantitative analyses on shock-heated gases in the determination of solar abundances. Oscillator strengths of Fe I obtained by the hook method are compared with f-values which have been measured by different experimental techniques. Although the hook values tend to be somewhat higher, they are in agreement with those obtained by wall-stabilized arc and shock-tube emission, the beamfoil techniques, and delayed coincidence measurements. Examples are given of other applications of shock-tube spectroscopy to solar and astrophysical studies such as comparisons of solar EUV spectra and laboratory observations of neutral iron, once-ionized iron, and the diatomic Fourth Positive system of CO.

Parkinson, W. H.↗

Non-isothermal laminar flow of gases through cooled tubes.

Numerical solutions of the laminar-flow equations in differential form are presented for gas flows through cooled tubes. For nearly isothermal flow there is good agreement with available experimental data, as is also found for the case of a large amount of wall cooling. This correspondence along with a check on the satisfaction of the global momentum and energy constraints allowed an appraisal of the effect of wall cooling on flow through tubes. In general, the effect of wall cooling was to decrease the wall friction and the change in pressure along tubes, but the average heat-transfer coefficient did not vary much.

Back, L. H.↗

Metal tube used as solar engine

Ends of metal tube are fastened to axles which are supported on bearings so tube can rotate about its long axis while subjected to invariant bending moment that stresses it along longitudinal axis of rotation. Heat absorbed leads to expansion of metal, which unbalances internal forces and generates rotational moment in tube.

Jedlicka, J. R.↗

Development of an engineering model traveling wave tube amplifier for space communication systems

A design has been made of a 100 watt traveling-wave tube amplifier for use in space communication applications. The features of very high overall efficiency and heat rejection of waste heat at low thermal densities were predominant in the design concept. The design concept was proven by building a series of tubes, operating at efficiencies up to 50%. These tubes utilized heat pipe cooling and heat distribution such that 150 watts of waste heat was rejected at a density of less than 1.5 watts per square inch. A power supply to convert a 28 volt primary line of the needs of the TWT was built and operated at 85% efficiency.

Eallonardo, C. M.↗

System efficiency of a microwave power tube with a multistage depressed collector

The efficiencies of a microwave power tube with a multistage depressed collector and of the power supply driving the tube are computed. An analytical expression for the collector efficiency, which includes the effect of secondary emission and the radial component of velocity, is derived for a hypothetical current probability distribution function. In addition, collector efficiency is calculated with the aid of a digital computer for a specific current distribution. The efficiency of the power supply required to operate the tube in a space environment is estimated by using a simple parallel inverter system.

Dayton, J. A., Jr.↗

Thermal expansion method for lining tantalum alloy tubing with tungsten

A differential-thermal expansion method was developed to line T-111 (tantalum - 8 percent tungsten - 2 percent hafnium) tubing with a tungsten diffusion barrier as part of a fuel element fabrication study for a space power nuclear reactor concept. This method uses a steel mandrel, which has a larger thermal expansion than T-111, to force the tungsten against the inside of the T-111 tube. Variables investigated include lining temperature, initial assembly gas size, and tube length. Linear integrity increased with increasing lining temperature and decreasing gap size. The method should have more general applicability where cylinders must be lined with a thin layer of a second material.

Watson, G. K.↗

Appraisal of UTIAS implosion-driven hypervelocity launchers and shock tubes.

A critical appraisal is made of the design, research, development, and operation of the novel UTIAS implosion-driven hypervelocity launchers and shock tubes. Explosively driven (PbN6-lead azide, PETN-pentaerythritetetranitrate) implosions in detonating stoichiometric hydrogen-oxygen mixtures have been successfully developed as drivers for hypervelocity launchers and shock tubes in a safe and reusable facility. Intense loadings at very high calculated pressures, densities, and temperatures, at the implosion center, cause severe problems with projectile integrity. Misalignment of the focal point can occur and add to the difficulty in using small caliber projectiles. In addition, the extreme driving conditions cause barrel expansion, erosion, and possible gas leakage from the base to the head of the projectile which cut the predicted muzzle velocities to half or a third of the lossless calculated values. However, in the case of a shock-tube operation these difficulties are minimized or eliminated and the possibilities of approaching Jovian reentry velocities are encouraging.

Glass, I. I.↗

Flight velocity effects on jet noise of several variations of a 48-tube suppressor installed on a plug nozzle

Because of the relatively high takeoff speeds of supersonic transport aircraft, it is important to know if the flight velocity affects the noise level of suppressor nozzles. To investigate this, a modified F-106B aircraft was used to conduct a series of flyover and static tests on a 48-tube suppressor installed on an uncooled plug nozzle. Comparison of flyover and static spectra indicated that flight velocity had little effect on the noise suppression of the 48-tube suppressor configuration. However, flight velocity adversely affected noise suppression of the 48-tube suppressor with an acoustic shroud and plug installed.

Burley, R. R.↗

Investigation of an anomalous flow condition of the Langley pilot model expansion tube

Free-stream flow velocity measurements were made in the Langley pilot model expansion tube during the test flow interval. During this interval, an anomalous dip in pitot pressure occurs for the expansion tube operating conditions employed. Within the test flow interval, the main conclusions reached from comparison of the measured flow velocity, pitot pressure, and tube wall pressure are: the variations which occur in velocity and wall pressure are small compared with the variations in pitot pressure; a corresponding dip in the derived flow density is associated with the dip in pitot pressure; and the value of the average density over the interval, which results from the expansion from the shocked intermediate chamber condition, is approximately one-half of the value that can result from only an isentropic process.

Friesen, W. J.↗

A finite-difference solution for unsteady wave interactions with an application to the expansion tube

An analytical study of the unsteady wave interaction of a shock wave overtaking a previously initiated shock tube flow has been conducted for a real gas by solving a finite-difference representation of the one-dimensional Navier-Stokes equations. This analysis has been used to determine the effect on the available test time of opening the secondary diaphragm in the expansion-tube operating cycle prior to the arrival of the incident shock wave. Special emphasis is placed on determining expansion-tube test-time limitations resulting from a nonuniform entropy distribution occurring during the early test-gas flow due to the varying Mach number of the incident shock wave as it traverses the expansion fan caused by the preopening process. Time distributions of velocity, temperature, pressure, and entropy at various distances from the diaphragm are presented as a function of the time required to open the diaphragm.

Weilmuenster, K. J.↗

A composite model for a class of electric-discharge shock tubes

A gasdynamic model is presented and analyzed for a class of shock tubes that utilize both Joule heating and electromagnetic forces to produce high-speed shock waves. The model consists of several stages of acceleration in which acceleration to sonic conditions is achieved principally through heating, and further acceleration of the supersonic flow is obtained principally through use of electromagnetic forces. The utility of the model results from the fact that it predicts a quasi-steady flow process, mathematical analysis is straightforward, and it is even possible to remove one or more component stages and still have the model related to a possible shock-tube flow. Initial experiments have been performed where the electrical discharge configuration and current level were such that Joule heating was the dominant form of energy addition present. These experiments indicate that the predictions of the model dealing with heat addition correspond quite closely to reality. The experimental data together with the theory show that heat addition to the flowing driver gas after diaphragm rupture (approach used in the model) is much more effective in producing high-speed shock waves than heating the gas in the driver before diaphragm rupture, as in the case of the arc-driven shock tube.

Elkins, R. T.↗

Development of an annular arc accelerator shock tube driver

An annular arc accelerator (ANAA) shock tube driver has been developed that deposits the energy of an arc discharge into a flowing gas, which then expands and cools without any delay for the opening of a diaphragm. A simplified one-dimensional flow analysis of the ANAA shock tube has been performed, which indicates that shock velocities greater than 40 km/sec may be obtained using a 300-kJ capacitor bank. The ANAA driver consists of a high-pressure driver, an expansion section, and an electrode section. In operation, the cold gas driver is pressurized until the diaphragm bursts, sending a pressure front down the expansion tube to the arc section. When the accelerated flow arrives at the electrode section, a 100-capacitor, 300-kJ capacitor bank is discharged either by breaking an insulating diaphragm between the electrodes or by the triggering of a series of external switches. Shock velocities of 28 km/sec have been obtained, and modifications are described that are expected to improve performance.

Leibowitz, L. P.↗

Study of Permanent Magnet Focusing for Astronomical Camera Tubes

A design is developed of a permanent magnet assembly (PMA) useful as the magnetic focusing unit for the 35 and 70 mm (diagonal) format SEC tubes. Detailed PMA designs for both tubes are given, and all data on their magnetic configuration, size, weight, and structure of magnetic shields adequate to screen the camera tube from the earth's magnetic field are presented. A digital computer is used for the PMA design simulations, and the expected operational performance of the PMA is ascertained through the calculation of a series of photoelectron trajectories. A large volume where the magnetic field uniformity is greater than 0.5% appears obtainable, and the point spread function (PSF) and modulation transfer function(MTF) indicate nearly ideal performance. The MTF at 20 cycles per mm exceeds 90%. The weight and volume appear tractable for the large space telescope and ground based application.

Long, D. C.↗

Permanent and separable aerospace tubing/ fitting evaluation program, volume 1

The tube fitting evaluation program was conducted to develop a standard overall test program including methods, procedures, and equipment as well as recommended test sequences for qualifying fitting/tubing assemblies. The program consisted of testing the MS flareless (separable) fitting and utilizing the results as baseline data from which all other fittings will be evaluated. Five separable designs and five permanent designs were tested in three sizes with two types of tubing materials. The basic design requirements were 4,000 psi operating pressure within the temperature range of minus 65 F to plus 450 F while also being compatible with 21-6-9 and titanium 3Al-2.5V tubing alloys.

Ursell, C. R.↗

Calibration of image dissector tubes

Technique employs computer-controlled light-emitting diode (LED), precision machined mask, and analog-to-digital coverter (ADC). Computer turns on LED which floods masked face of tube. Intensity pattern, generated as tube is electromagnetically swept, is fed to ADC which controls tube calibration.

Klingman, E. E., III↗