Search NASA⌕ Search

SEARCH · Search NASA

Results for “TURBINES - BLADES - CASCADES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Optimal Wind Turbine Design for H2 Production

NREL and industrial partners GE and Nel seek to advance affordable green hydrogen production by optimizing wind turbine design specifically for hydrogen production and validating designs using NREL's ARIES facilities. This project will couple wind turbine, wind plant, solar plant, and electrolyzer models to predict hydrogen production from variable, renewable power sources. It will then use gradient-based optimization with exact-analytic gradients to optimize wind turbine rotor diameter, hub height, and power rating for optimal hydrogen production. Finally, it will validate the optimal turbine designs using the ARIES research platform, where it will compare a baseline turbine to the optimal design for a variety of scenarios and resources.

electrolyzer↗

Turbine nozzle and method of manufacture

Methods of fabricating a turbomachine component and turbomachine components are provided. The method includes irradiating a layer of powder in a powder bed to form a fused region. The powder is disposed on a build plate. The method further includes a step of providing a subsequent layer of powder over the powder bed by passing a recoater arm over the powder bed from a first side of the powder bed. The method further includes repeating the irradiating and providing steps until a turbine nozzle assembly is formed on the build plate. The turbine nozzle assembly includes the turbine nozzle and a plurality of heat fins disposed within the turbine nozzle. The plurality of heat fins transfer heat away from a thermally sensitive portion of the turbine nozzle.

Griffis, Clay Thomas↗

2022 Small Turbine Certification Awardee: NPS Solutions

Inverters convert the direct current power generated by wind turbines into the alternating current needed to serve local loads and feed onto the electricity grid. Although distributed wind systems typically supply electricity for homes and businesses near the turbines, these systems can also provide clean power to strengthen grid resilience. Certification to UL 1741 SA ensures that inverters will enable distributed wind turbines to provide grid support services and stay online when the grid experiences stability issues. Small companies often find the electrical listing process too complex and expensive to undertake on their own, so few distributed wind turbine inverters are certified to this standard. A U.S. Department of Energy (DOE) Competitiveness Improvement Project (CIP) award is helping NPS Solutions (NPS) secure this critical certification for the inverter in its 100-kilowatt NPS 100C wind turbine, which is optimized for on-site generation at farms, businesses, schools, hospitals, and remote locations.

CIP↗

Water separator for turbine engine

A turbine engine is provided that includes a turbine engine core, a water separate and a core flowpath. The turbine engine core includes a core compressor section, a core combustor section and a core turbine section. The water separator includes a flowpath duct and a collector duct. The flowpath duct extends axially along and circumferentially about an axis. The collector duct extends axially along and circumferentially about the flowpath duct. The collector duct is fluidly coupled with the flowpath duct through a water permeable region in an outer wall of the flowpath duct. The core flowpath extends through the core compressor section, the core combustor section, the core turbine section and the flowpath duct from an inlet into the core flowpath to an exhaust from the core flowpath. The core flowpath extends axially along the water permeable region within the flowpath duct.

Alahyari, Abbas A.↗

Modeling a Bulb-Style Kaplan Unit Hydrogovernor and Turbine in Mathworks-Simulink and RTDS-RSCAD

Some run-of-river (ROR) hydropower plants use a horizontal bulb-style Kaplan turbine. This turbine and the corresponding governor are not represented well in standard high-fidelity power-system modeling platforms. This paper presents the characterization, development, and modeling of bulb-style Kaplan turbine and associated hydrogovernor equipment in two platforms: Simulink from the MathWorks, Inc., and RSCAD from RTDS Technologies, Inc. The developed models enable accurate assessment of the response of a bulb-style Kaplan hydropower unit to changes in electrical loading and water conditions. The resulting models enable accurate digital real-time simulation with hardware-in-the-loop testing of this class of turbine, which was not previously possible. This, in turn, improves the ability to innovate these technologies and hybridize them in a lab setting, accelerating the potential for innovation in this type of ROR hydropower plant.

13 HYDRO ENERGY↗

Emrgy 2022 Hydrokinetic Turbine Data - TEAMER Post Access Submission

The data herein contains all data collected and used for the Performance Characterization Testing and Model Calibration of a Vertical Axis Hydrokinetic Turbine. The data includes performance data and durability data for the Hydrokinetic Turbine. The device performance data contains shaft RPM, turbine RPM, power output, flow velocity, pressure, and pressure drop across the turbine. The mechanical durability data includes stress and strain at varied depths and velocities. There is also an FEA analysis included. This TEAMER project was awarded to Emrgy, Inc.in collaboration with Alden Research Laboratory LLC.

16 TIDAL AND WAVE POWER↗

TEAMER: Pitching Foil Crossflow Turbine Efficiency Data

This dataset documents the efficiency testing of a pitching foil crossflow turbine, conducted at the University of New Hampshire's (UNH) Chase Ocean Engineering Laboratory tow tank facility. The tests explored various pitch phases and amplitudes, ranging from 0 to 18 degrees, across different flow speeds and turbine RPMs. Specifically, testing was performed at pitch amplitudes of 0,3,6,9,12,15 and 18 degrees. The results indicate that turbine efficiency improves with increased pitch amplitude, reaching optimal performance at 12 degrees. Modifications were made to the test frame by UNH to enhance the stiffness of the support structure. The testing specifically mapped the efficiency of a single quadrant of the Ocean Renewable Power Company (ORPC) Autonomous Turbine Generator Unit (ATGU), covering the full range of allowable pitching amplitudes and phases. The dataset provides both raw and processed data, including drag and torque measurements, and contains Python scripts used for data processing and visualization. This research was supported by funding from TEAMER RFTS 1 (Request for Technical Support).

16 TIDAL AND WAVE POWER↗

High-Fidelity Modeling of a Type-5 Wind Turbine Gearbox (Intern Poster) [Poster]

Type-5 wind turbines are unique in their use of a permanent magnet synchronous generator, as well as their use of a hydraulic torque converter. This architecture presents an opportunity to provide steady and grid-ready energy without the need for a power converter. With infrastructure continuity and reliability being an important topic amongst renewable energies, researchers have been prompted to further investigate the benefits of type-5 turbines’ unique electromechanical configuration on stable electricity generation. Researchers involved in the WindSG project, SG standing for synchronous generator, are aiming to model a type-5 turbine using Real Time Digital Simulation (RTDS) to evaluate its efficacy in the grid. RSCAD, the software run on the RTDS, comes pre-loaded with electrical and electromechanical components to help simulate electrical generation and grid conditions. However, within this repertoire there is a lack of a component to represent a gearbox with high-fidelity. Within RSCAD’s case studies, the gearbox is often represented simply by a gear ratio value. This presented the task of developing a high-fidelity gearbox model in RSCAD for use in the larger RTDS type-5 wind turbine model. This poster describes a method of developing a lumped parameter mathematical model to represent a planetary-parallel-parallel gearbox in RSCAD for use in RTDS.

17 WIND ENERGY↗

High-Fidelity Modeling of a Type-5 Wind Turbine Gearbox (Intern Technical Presentation) (Poster)

Type-5 wind turbines are unique in their use of a permanent magnet synchronous generator, as well as their use of a hydraulic torque converter. This architecture presents an opportunity to provide steady and grid-ready energy without the need for a power converter. With infrastructure continuity and reliability being an important topic amongst renewable energies, researchers have been prompted to further investigate the benefits of type-5 turbines’ unique electromechanical configuration on stable electricity generation. Researchers involved in the WindSG project, SG standing for synchronous generator, are aiming to model a type-5 turbine using Real Time Digital Simulation (RTDS) to evaluate its efficacy in the grid. RSCAD, the software run on the RTDS, comes pre-loaded with electrical and electromechanical components to help simulate electrical generation and grid conditions. However, within this repertoire there is a lack of a component to represent a gearbox with high-fidelity. Within RSCAD’s case studies, the gearbox is often represented simply by a gear ratio value. This presented the task of developing a high-fidelity gearbox model in RSCAD for use in the larger RTDS type-5 wind turbine model. This presentation describes a method of developing a lumped parameter mathematical model to represent a planetary-parallel-parallel gearbox in RSCAD for use in RTDS.

17 WIND ENERGY↗

Preliminary Study of Heat Pipe Turbine Vane Cooling in the NASA N+3 Reference Engine

This paper investigates the effects of implementing Heat Pipe Turbine Vane (HPTV) cooling in the NASA N+3 engine. The HPTV can be thought of as a heat pipe in the shape of a turbine vane, functioning as both an aerodynamic body and heat exchanger. The heat-absorbing section of the HPTV remains fixed in the vanes of the high pressure turbine (HPT), while the heat-rejecting section can be placed in any stage of the low pressure turbine (LPT) as well as the bypass stream. The optimal location of the condensing (heat-rejecting) section is shown to be in the bypass stream for both HPT stages. The thrust specific fuel consumption increased by 0.2%, which is mainly attributed to the elimination of air cooling in the second stage HPT vanes combined with the transfer of energy from the main gas path to elsewhere in the cycle. Air cooling is also eliminated in the first stage HPT vanes, but this cooling air is nonchargeable. A preliminary design is proposed and shown to demonstrate the desired performance and operates below all the heat flux limitations in the first stage HPT . The design in the second stage HPT exceeds a limiting phenomenon but is expected to be remedied by changing the working fluid.

Gas Turbine↗

Preliminary Study of Heat Pipe Turbine Vane Cooling in the NASA N+3 Reference Engine

This investigates the effects of implementing Heat Pipe Turbine Vane (HPTV) cooling in the NASA N+3 engine. The HPTV can be thought of as a heat pipe in the shape of a turbine vane, functioning as both an aerodynamic body and heat exchanger. The heat-absorbing section of the HPTV remains fixed in the vanes of the high pressure turbine (HPT), while the heat-rejecting section can be placed in any stage of the low pressure turbine (LPT) as well as the bypass stream. The optimal location of the condensing (heat-rejecting) section is shown to be in the bypass stream for both HPT stages. The thrust specific fuel consumption increased by 0.2%, which is mainly attributed to the elimination of air cooling in the second stage HPT vanes combined with the transfer of energy from the main gas path to elsewhere in the cycle. Air cooling is also eliminated in the first stage HPT vanes, but this cooling air is nonchargeable. A preliminary design is proposed and shown to demonstrate the desired performance and operates below all the heat flux limitations in the first stage HPT . The design in the second stage HPT exceeds a limiting phenomenon but is expected to be remedied by changing the working fluid.

Gas Turbine↗

Review of wake management techniques for wind turbines

Summary The progression of wind turbine technology has led to wind turbines being incredibly optimized machines often approaching their theoretical maximum production capabilities. When placed together in arrays to make wind farms, however, they are subject to wake interference that greatly reduces downstream turbines' power production, increases structural loading and maintenance, reduces their lifetimes, and ultimately increases the levelized cost of energy. Development of techniques to manage wakes and operate larger and larger arrays of turbines more efficiently is now a crucial field of research. Herein, four wake management techniques in various states of development are reviewed. These include axial induction control, wake steering, the latter two combined, and active wake control. Each of these is reviewed in terms of its control strategies and use for power maximization, load reduction, and ancillary services. By evaluating existing research, several directions for future research are suggested.

17 WIND ENERGY↗

Wind turbine main bearing rating lives as determined by IEC 61400‐1 and ISO 281: A critical review and exploratory case study

Abstract This paper studies the rating lives of wind turbine main bearings, as determined by the IEC 61400‐1 and ISO 281 standards. A critical review of relevant bearing life theory and turbine design requirements is provided, including discussion on possible shortcomings such as the existence (or not) of the bearing fatigue load limit and the validity of assuming linear damage accumulation. A detailed exploratory case study is then undertaken to determine rating lives for two models of main bearing in a 1.5 MW wind turbine. Rating life assessment is carried out under different conditions, including various combinations of main bearing temperature, wind field characteristics, lubricant viscosity, and contamination levels. Rating lives are found to be sufficiently above the desired 20‐year design life for both bearing models under expected operating conditions. For the larger bearing, operational loads are shown to be below or close to the bearing fatigue load limit a vast majority of the time. Key sensitivities for rating life values are temperature and contamination. Overall, the results of this study suggest that an ISO 281 rating life assessment does not account for reported rates of main bearing failures in 1 to 3 MW wind turbines. It is recommended that a similar analysis be undertaken for ISO/TS 16281 rating lives, along with further efforts to identify principal root causes of main bearing failures in future work, possibly leading to a new application standard specific to this component. It is also recommended that the impacts of partial wake impingement on main bearing rating lives are investigated.

17 WIND ENERGY↗

Modeling, Validation, and Control of the IEA‐15 MW Reference Wind Turbine and VolturnUS‐S Platform

This paper presents the acausal modeling, validation, and control of floating offshore wind turbines (FOWTs). The model simulates the IEA‐15 MW reference turbine and the semi‐submersible VolturnUS‐S platform utilizing a Control‐oriented, Reconfigurable, and Acausal Floating Turbine Simulator (CRAFTS), which integrates the key coupled aero‐hydro‐elasto‐servo dynamics and is being developed by authors at the University of Central Florida. Verification and validation are conducted using numerical data from the industry‐standard simulation platform OpenFAST and experimental data from the Floating Offshore‐wind and Controls Advanced Laboratory (FOCAL) project, in which the authors were involved. Numerical results demonstrate the model's ability to qualitatively capture loads and responses across various load cases, highlighting the impact of the control system under different wind and wave conditions and opening new opportunities for optimizing FOWT designs. This paper provides wind turbine researchers with valuable insights into system characteristics, system frequencies, damping effects, and internal reaction forces, serving as a reference for future studies in FOWT modeling and control.

17 WIND ENERGY↗

Lessons learned from the design and operation of a small-scale cross-flow tidal turbine

In 2023, a first-generation prototype of a small-scale marine current turbine was operated in Sequim Bay, Washington (USA) for 141 days. The system, referred to as the Turbine Lander, was the product of a laboratory-to-field effort to develop a system that enables enhanced ocean sensing or vehicle recharge in remote, energetic settings. The turbine consists of a vertical-axis, cantilevered rotor (1.19 m x 0.85 m) with four foils installed on a gravity foundation. A broader range of constraints including the deployment strategy, site characteristics, and estimated loads, drove the system’s design. This work presents the design, characterization, operation, and post-recovery engineering assessment of the Turbine Lander. Pre-deployment characterization efforts yielded a peak power coefficient of approximately 0.3 for the rotor, although system losses resulted in much lower water-to-wire efficiencies under most operating conditions. The results demonstrate the importance of co-design among key components of the powertrain and control systems to achieve acceptable system efficiency across operating conditions.

Co-design↗

An Update to the National Renewable Energy Laboratory Baseline Wind Turbine Controller

The National Renewable Energy Laboratory's 5-MW wind turbine model is well established as an industry standard and is often used as a comparison model, or a model on which to build upon. Though effective, the legacy controller for the 5-MW wind turbine uses a simple algorithm that is not up to date with many industry standards. Additionally, as the research community has advanced into fast-paced development cycles, as systems engineering tools such as Wind-Plant Integrated System Design & Engineering Model (WISDEM ®) [1] are employed, and as a greater focus on controls co-design practices is encouraged, demand for a generic wind turbine controller has arisen. This work presents updates for the NREL 5-MW controller to a more modern control architecture, and establishes a generic tuning framework that can be easily adapted to various wind turbines. Based on initial results, the updated generic controller eases the automatic tuning process while maintaining or improving the performance of the legacy NREL 5-MW controller.

17 WIND ENERGY↗

IEA Wind Task 32 and Task 37: Optimizing Wind Turbines with Lidar-Assisted Control Using Systems Engineering

Lidar-assisted control is a promising technology for reducing the levelized cost of energy from wind turbines, but quantifying its impact at the overall system level requires sophisticated systems engineering analysis and optimization frameworks. The joint workshop on Optimizing Wind Turbines with Lidar-Assisted Control Using Systems Engineering was held by the International Energy Agency Wind Task 32 (Lidar) and Task 37 (Systems Engineering) in October 2019 to address this challenge. This paper summarizes the outcome of the workshop and presents a road map for further research. The most promising applications of lidar-assisted control identified at the workshop and discussed here include 1) increasing annual energy production, 2) decreasing capital expenditure costs by reducing design loads, 3) extending turbine lifetime by reducing operating loads, and 4) enabling wind turbine class upgrades. For each application, we review the state of the art and highlight remaining research needs. Finally, we discuss strategies for addressing these research needs by conducting high-fidelity systems engineering optimizations.

17 WIND ENERGY↗

Rapid approach for structural design of the tower and monopile for a series of 25 MW offshore turbines

The goal of further reducing the Levelized Cost of Energy (LCOE) has driven the investigation of large-scale wind turbines. This work presents a simple, rapid and detailed approach for the structural design of the tower and monopile without a controller, but with frequency and high fidelity structural verification. The approach uses an optimization to reduce the mass of the structures while meeting strength, buckling and geometric constraints by using analytical equations. A verification of frequency constraints is performed with BModes, and ANSYS Mechanical APDL is used for high fidelity verification of stress and buckling. The approach is applied to study the design space of three 25 MW offshore wind turbines with different rotor diameters and cone angles, and to evaluate the nacelle center of mass fore-aft location effect. Results obtained show that the tower and monopile are more susceptible to changes in the rotor thrust than the overturning moment even for designs with high pre-cone angle and large distance of the nacelle center of mass from the tower axis. But it is possible to obtain structurally feasible tower and monopile designs for the three 25 MW turbines studied while not exceeding diameter and wall thickness limits. However, mass penalties can be decreased by 0.8-14%, to further reduce the cost of energy, by increasing the diameter limit which may require manufacturing technology development. The approach applied and studies serve to understand the design space of the tower and monopile for a 25 MW turbine, and provide baseline designs that can be used in the development of a controller and evaluation of a full suite of design load cases.

17 WIND ENERGY↗