Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time Projection Chamber”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Present and Future of Central Production With STAR Detector at RHIC

The present status and future of the physics program of Central Production using the STAR detector at RHIC are described. The program focuses on particle production in the Double Pomeron Exchange (DPE) process. Forward protons from the DPE interaction are detected in the Roman Pot system installed at 55.5 m and 58.5 m on both sides of the STAR interaction point. The recoil system of charged particles from the DPE process is measured in the STAR Time Projection Chamber (TPC). The first data were taken during the 2009 RHIC Run 9 using polarized proton-proton collisions at {radical}(s) 200 GeV. The preliminary spectra of two pion and four pion invariant mass reconstructed by STAR TPC in central region of pseudo-rapidity |{eta}|<1, are presented. Plans to take data with the current system at {radical}(s) = 500 GeV and plans to upgrade the forward proton tagging system, so that it can reach higher masses and obtain large data samples to allow searching for glueballs that could be produced in the DPE process, are also discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Potentials for J/{psi} from b decays measurement in the ALICE experiment at LHC

The ALICE potentials in proton-proton collisions for the measurement of the fraction of J/{psi} produced at central rapidity (|y|<0.9) in beauty hadrons semi-inclusive decays, namely B{yields}J/{psi}X, is discussed.This measurement relies on the combined use of the Time Projection Chamber (TPC), for tracking and particle identification via dE/dx measurement; the Inner Tracking System (ITS) for tracking and detection of displaced vertices; the Transition Radiation Detector (TRD) for particle identification.The description of the analysis method developed and the discussion of the estimate for a total J/{psi} statistics corresponding to one year of ALICE data taking in p-p collisions at {radical}(s) = 7 TeV is provided in the article.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the evaluation of silicon photomultipliers for use as photosensors in liquid xenon detectors

Silicon photomultipliers (SiPMs) are potential solid-state alternatives to traditional photomultiplier tubes (PMTs) for single-photon detection. In this paper, we report on evaluating SensL MicroFC-10035-SMT SiPMs for their suitability as PMT replacements. The devices were successfully operated in a liquid-xenon detector, which demonstrates that SiPMs can be used in noble element time projection chambers as photosensors. The devices were also cooled down to 170 K to observe dark count dependence on temperature. Here, no dependencies on the direction of an applied 3.2 kV/cm electric field were observed with respect to dark-count rate, gain, or photon detection efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The electric field dependence of single electron emission in the PIXeY two-phase xenon detector

Dual phase xenon detectors are widely used in experimental searches for galactic dark matter particles. The origin of single electron backgrounds following prompt scintillation and proportional scintillation signals in these detectors is not fully understood, although there has been progress in recent years. Here, in this paper, we describe single electron backgrounds in 83m Kr calibration events and their correlation with drift and extraction fields, using the Particle Identification in Xenon at Yale (PIXeY) dual-phase xenon time projection chamber. The single electron background induced by the Fowler-Nordheim (FN) effect is measured, and its electric field dependence is quantified. The photoionization of grids and impurities by prompt scintillation and proportional scintillation also contributes to the single electron background.

47 OTHER INSTRUMENTATION↗

Simulation results for a low energy nuclear recoil yields measurement in liquid xenon using the MiX detector

Measuring the scintillation and ionization yields of liquid xenon in response to ultra-low energy nuclear recoil events is necessary to increase the sensitivity of liquid xenon experiments to light dark matter. Neutron capture on xenon can be used to produce nuclear recoil events with energies below 0.3 keV NR via the asymmetric emission of γ rays during nuclear de-excitation. The feasibility of an ultra-low energy nuclear recoil measurement using neutron capture was investigated for the Michigan Xenon (MiX) detector, a small dual-phase xenon time projection chamber that is optimized for a high scintillation gain. Simulations of the MiX detector, a partial neutron moderator, and a pulsed neutron generator indicate that a population of neutron capture events can be isolated from neutron scattering events. Additionally, the rate of neutron captures in the MiX detector was optimized by varying the thickness of the partial neutron moderator, neutron pulse width, and neutron pulse frequency.

detector calibration↗

Scintillation light detection performance for the DUNE ND-LAr 2 × 2 modules

The Deep Underground Neutrino Experiment (DUNE) will be using a liquid argon time projection chamber (LAr TPC) with optically separated modules in the Near Detector (ND) complex. A prototype experiment, DUNE ND-LAr 2 × 2, is composed of four test modules. They detect ionization charge through a pixel-based readout and scintillation light through fibers in light collection modules and light traps called ArCLights. The light detection performance for two modules of DUNE ND-LAr 2 × 2 that took cosmic ray data at the University of Bern is shown. We present further the role of the 2 × 2 prototype in DUNE and how it is used to demonstrate the reconstruction capabilities of its light detectors in terms of energy thresholds and timing resolution.

47 OTHER INSTRUMENTATION↗

The Enriched Xenon Observatory

The Enriched Xenon Observatory (EXO) experiment will search for neutrinoless double beta decay of {sup 136}Xe. The EXO Collaboration is actively pursuing both liquid-phase and gas-phase Xe detector technologies with scalability to the ton-scale. The search for neutrinoless double beta decay of {sup 136}Xe is especially attractive because of the possibility of tagging the resulting Ba daughter ion, eliminating all sources of background other than the two neutrino decay mode. EXO-200, the first phase of the project, is a liquid Xe time projection chamber with 200 kg of Xe enriched to 80% in {sup 136}Xe. EXO-200, which does not include Ba-tagging, will begin taking data in 2009, with two-year sensitivity to the half-life for neutrinoless double beta decay of 6.4x10{sup 25} years. This corresponds to an effective Majorana neutrino mass of 0.13 to 0.19 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Analysis of TPC Single Sextant U-238/U-235 Engineering In-Beam Data

The Time Projection Chamber is a collaborative effort to implement an innovative approach and deliver unprecedented fission measurements to DOE programs. This 4π- detector system will provide unrivaled 3-D data about the fission process. This TPC has been shipped and installed at LANSCE and is collecting further engineering data for the full system scale up next year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Observation of radon mitigation in MicroBooNE by a liquid argon filtration system

We report the MicroBooNE liquid argon time projection chamber (LArTPC) maintains a high level of liquid argon purity through the use of a filtration system that removes electronegative contaminants in continuously-circulated liquid, recondensed boil off, and externally supplied argon gas. We use the MicroBooNE LArTPC to reconstruct MeV-scale radiological decays. Using this technique we measure the liquid argon filtration system's efficacy at removing radon. This is studied by placing a 500 kBq 222 Rn source upstream of the filters and searching for a time-dependent increase in the number of radiological decays in the LArTPC. In the context of two models for radon mitigation via a liquid argon filtration system, a slowing mechanism and a trapping mechanism, MicroBooNE data supports a radon reduction factor of greater than 97% or 99.999%, respectively. Furthermore, a radiological survey of the filters found that the copper-based filter material was the primary medium that removed the 222 Rn. This is the first observation of radon mitigation in liquid argon with a large-scale copper-based filter and could offer a radon mitigation solution for future large LArTPCs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The US Long Baseline Neutrino Experiment Study

The US Long Baseline Neutrino Experiment Study was commissioned jointly by Brookhaven National Laboratory (BNL)and Fermi National Accelerator Laboratory (FNAL) to investigate the potential for future U.S. based long baseline neutrino oscillation experiments using MW class conventional neutrino beams that can be produced at FNAL. The experimental baselines are based on two possible detector locations: 1) off-axis to the existing FNAL NuMI beamline at baselines of 700 to 810 km and 2) NSF's proposed future Deep Underground Science and Engineering Laboratory (DUSEL) at baselines greater than 1000 km. Two detector technologies are considered: a megaton class Water Cherenkov detector deployed deep underground at a DUSEL site, or a 100 kT Liquid Argon Time-Projection Chamber (TPC) deployed on the surface at any of the proposed sites. The physics sensitivities of the proposed experiments are summarized. We find that conventional horn focused wide-band neutrino beam options from FNAL aimed at a massive detector with a baseline of >1000 km have the best sensitivity to CP violation and the neutrino mass hierarchy for values of the mixing angle {theta}{sub 13} down to 2 deg.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Short-Baseline Neutrino Program at Fermilab

The Short-Baseline Neutrino (SBN) program consists of three liquid argon time-projection chamber detectors located along the Booster Neutrino Beam at Fermi National Accelerator Laboratory. Its main goals include searches for New Physics—particularly eV-scale sterile neutrinos, detailed studies of neutrino–nucleus interactions at the GeV energy scale, and the advancement of the liquid argon detector technology that will also be used in the DUNE/LBNF long-baseline neutrino experiment in the next decade. Here, we review these science goals and the current experimental status of SBN.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

BoNuS: Development and Use of a Radial TPC using Cylindrical GEMs

To provide new access to information about nucleon structure from electron-neutron interactions, a specialized aystem of target and detector was developed at Jefferson Lab. It allows identification and measurement of spectator protons produced in e X scattering events. The detector is a radial time-projection chamber optimized for the acceptance of low-momentum protons. Gas gain is provided by three cascaded curved Gas Electron Multipliers (GEMs), the first application of GEMs in any configuration other than flat.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lifetime study of the ColdADC for the Deep Underground Neutrino Experiment

ColdADC is a custom ASIC digitizer implemented in 65 nm CMOS technology using specialized techniques for long-term reliability in cryogenic environments. ColdADC was developed for use in the DUNE Far Detector complex, which will consist of four liquid argon time projection chambers. Each contains 17 kilotons liquid argon as the target material in order to measure neutrino oscillations. Approximately 40,000 ColdADC ASICs will be installed for DUNE in the first two large detectors and will be operated at cryogenic temperatures during the experiment without replacement. The lifetime of the ColdADC is a critical parameter affecting the data quality and physics sensitivity of the experiment. A measurement of the lifetime of the ColdADC was carried out, and the results shown in this paper assure orders of magnitude longer lifetime of the ColdADC than the planned operation time of the detectors.

Front-end electronics for detector readout↗

The XENON10 WIMP Direct Detection Search at the Gran Sasso Underground Laboratory

The direct detection search for WIMPs with the XENON10 detector has produced among the best results in the field to date. The detector is a dual-phase liquid xenon time projection chamber, capable of 3-D position reconstruction and nuclear recoil discrimination. We summarize 58.6 live-days of WIMP search data collected at the Gran Sasso Underground Laboratory (LNGS) in Italy. With this data we have been able to set stringent upper limits on the spin-dependent and spin-independent WIMP scattering cross sections, in addition to a lower limit of 2.2 TeV/c{sup 2} on the mass of the heavy Majorana neutrino.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Status of The US Long Baseline Neutrino Experiment Study

The US Long Baseline Neutrino Experiment Study was commissioned jointly by Brookhaven National Laboratory and Fermi National Accelerator Laboratory to investigate the potential for future U.S. based long baseline neutrino oscillation experiments beyond the currently planned program. The Study focused on MW class conventional neutrino beams that can be produced at Fermilab or BNL. The experimental baselines are based on two possible detector locations: 1) off-axis to the existing Fermilab NuMI beamline at baselines of 700 to 810 km and 2) NSF's proposed future Deep Underground Science and Engineering Laboratory (DUSEL) at baselines greater than 1000 km. Two detector technologies are considered: a megaton class Water Cherenkov detector deployed deep underground at a DUSEL site, or a 100 kT Liquid Argon Time-Projection Chamber (TPC) deployed on the surface at any of the proposed sites. The physics sensitivities of the proposed experiments are summarized. We find that conventional horn focused wide-band neutrino beam options from Fermilab or BNL aimed at a massive detector with a baseline of >1000 km have the best sensitivity to CP violation and the neutrino mass hierarchy for values of the mixing angle {theta}{sub 13} down to 2.2 deg.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A system to test the effects of materials on the electron drift lifetime in liquid argon and observations on the effect of water

A materials test system (MTS) has been developed at FNAL to assess the suitability of materials for use in a large liquid argon time projection chamber. During development of the MTS, it was noted that controlling the cryostat pressure with a 'raining' condenser reduced the electron drift lifetime in the liquid argon. The effect of condensing has been investigated using a series of passive materials to filter the condensate. We report the results of these studies and of tests on different candidate materials for detector construction. The inferred reduction of electron drift lifetime by water concentrations in the parts per trillion is of particular interest.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results from the XENON10 Dark Matter search experiment at Gran Sasso Laboratories

One of the most appealing questions in astroparticle physics concerns the nature of the Dark Matter (DM) particles and their possible interaction with ordinary matter. In order to find a solution to such problem, a double phase liquid-gas Xenon Time Projection Chamber has been proposed and built as a suitable detector for the direct detection of DM in the form of Weakly Interacting Massive Particles (WIMPs). The possibility of simultaneously measuring the scintillation and the ionization signals, and a 3D event localization feature, represent a powerful background discrimination method. During the Autumn-Winter 2006-2007 a prototype of 15 kg sensitive mass of Liquid Xenon (XENON10) has been successfully run at the Gran Sasso Underground Laboratory. The technique and the results of the XENON10 detector are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radioactive nuclear beams of COMBAS facility

The basic ion-optical characteristics of the luminosity and the high-resolution of kinematic separator COMBAS realized for the first time on the strong focusing principle are presented. The developed facility allows to separate the high-intensity secondary radioactive beams in a wide range of mass numbers A and atomic numbers Z which are produced in heavy ion reactions in the energy range of 20 ≤ E ≤ 100 MeV/A (Fermi energy domain). Two distinct detector systems such as realized Si strip detector telescope and the promising development of the three dimension time-projection chamber are discussed. Program of the investigations of nuclear reaction mechanisms at intermediate energies of 20–100 MeV/A, measurement of the radii of unstable nuclei, study of the cluster structure of light nuclei near the nuclear drip-line and search of {sup 26,28}O resonances in exchange reactions is proposed. The upgrading of experimental facility by the integration of COMBAS separator with the Ion Catcher is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗