Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Wisconsin In Situ Penning (WISP) gauge: A versatile neutral pressure gauge to measure partial pressures in strong magnetic fields

A new type of in-vessel Penning gauge, the Wisconsin In Situ Penning (WISP) gauge, has been developed and successfully operated in the Wendelstein 7-X (W7-X) island divertor baffle and vacuum vessel. The capacity of the quantitative measurements of the neutral reservoir for light impurities, in particular, helium, is important for tokamaks as well as stellarator divertors in order to avoid fuel dilution and radiative energy loss. Penning gauges assisted by spectroscopy are a powerful tool to obtain the total neutral pressure as well as fractional neutral pressures of specific impurities. The WISP gauge is a miniaturized Penning gauge arrangement, which exploits the ambient magnetic field of magnetic confinement fusion experiments to establish the Penning discharge. Then, in situ spectroscopy is conducted to separate the fractional neutral pressures of hydrogen, helium, and possibly also other impurities. The WISP probe head was qualified using the magnetic field of the Magnetized Dusty Plasma Experiment at Auburn University between 0.25 T and 3.5 T [E. Thomas et al ., J. Plasma Phys. 81, 345810206 (2015)]. The in-depth quantitative evaluation for hydrogen and helium will be shown as well as an exploration of nitrogen, argon, and neon. A power law scaling between current I and pressure p, I = f (Gas,V) p n⁽Gas, B⁾ , was shown. The factor f is gas and anode potential dependent, while n is gas and magnetic field strength dependent. Pressure measurements from 0.1 mbar and down to 1 × 10 -5 mbar were achieved, demonstrating a reliable operating range for relevant pressure levels in the divertor and main vessel regions in current and future fusion devices, with a time resolution of up to 1 kHz. The lowest achievable pressure measurement increases with an increase in B and can be shifted with the anode potential V . At W7-X, the WISP probe head was mounted on an immersion tube setup that passes through the cryostat and places the probe head close to the plasma. Two probe heads were positioned in different divertor pump gaps, top and bottom, and one close to the plasma on the midplane in one module. The gauges were in situ calibrated together with the ASDEX pressure gauges [G. Haas and H.-S. Bosch, Vacuum 51, 39 (1998)]. Data were taken during the entire operation phase 1.2b, and measurements were coherent with other neutral gas pressure gauges. For the spectroscopic partial pressure measurements, channels of a spectroscopic detection system based on photo-multipliers, a so-called filterscope [R. J. Colchin et al ., Rev. Sci. Instrum. 74, 2068 (2003)], provided by the Oak Ridge National Lab were used.

47 OTHER INSTRUMENTATION↗

Forward modeling of Doppler velocity interferometer system for improved shockwave measurements

We report that when near-instantaneous shocks are recorded by using a Doppler velocity interferometer velocity interferometer system for any reflector (VISAR), they typically exceed the detector’s ability to react and “skipped fringes” result, where its visibility briefly reduces. Traditionally, replacing skipped fringes required guesswork in analysis, which increased arrival time errors. Second, the use of long but velocity-sensitive interferometer delays with fast detectors which can resolve the delay has traditionally been avoided because of the fear of confusing the arrival time signal. However, shorter delays produce smaller fringe phase shifts per velocity and, thus, can decrease velocity precision. We realize that while some loss of fringe information occurs at shock events, this is often just a partial loss and the residual fringe information can still hold valuable information. We describe a forward model (FM) of the interferometer action and detector blurring that assists with VISAR fringe analysis at skipping events: (1) more precise shock arrival times, (2) arrival time precision not limited by long delays, and (3) improved ghost subtraction, which improves accuracy over a broad time region. Lastly, we demonstrate the utility of a FM on National Ignition Facility and Laboratory for Laser Energetics Omega shots and discuss data process methods to increase the high time resolution of VISAR systems despite their limitations and complexities.

47 OTHER INSTRUMENTATION↗

Subsurface spectroscopy of heterogeneous materials using optical wavefront shaping

Plastic-bonded explosives and propellants consist of energetic molecular crystals embedded in a polymer matrix that also includes additives, such as taggants, plasticizers, grit, antioxidants, etc. Furthermore, this heterogeneous composition renders these materials optically opaque, limiting optical characterization techniques (e.g., Raman spectroscopy) to probing chemical reactions at the sur-face. However, many reactions of interest are believed to occur inside the material where current optical techniques can not probe. To address this challenge, we have developed a new optical technique that utilizes feedback assisted wavefront shaping (using spatial light modulators) to focus probe light inside a heterogeneous material, such that we can perform subsurface spectroscopy. Recently, we demonstrated this technique by monitoring subsurface photodegradation and thermal degradation of Eu-doped molecular crystals using both fluorescence and Raman spectroscopy. Based off these successes we are now looking into improvements to this technique to allow for greater time resolution, including replacing our spatial light modulators with fast digital mirror devices, using ns optical phase conjugation, and self-healing optical beams.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A kiloelectron-volt ultrafast electron micro-diffraction apparatus using low emittance semiconductor photocathodes

We report the design and performance of a time-resolved electron diffraction apparatus capable of producing intense bunches with simultaneously single digit micrometer probe size, long coherence length, and 200 fs rms time resolution. We measure the 5d (peak) beam brightness at the sample location in micro-diffraction mode to be 7×1013 A/m2 rad2. To generate high brightness electron bunches, the system employs high efficiency, low emittance semiconductor photocathodes driven with a wavelength near the photoemission threshold at a repetition rate up to 250 kHz. We characterize spatial, temporal, and reciprocal space resolution of the apparatus. We perform proof-of-principle measurements of ultrafast heating in single crystal Au samples and compare experimental results with simulations that account for the effects of multiple scattering.

43 PARTICLE ACCELERATORS↗

Relativistic ultrafast electron diffraction at high repetition rates

The ability to resolve the dynamics of matter on its native temporal and spatial scales constitutes a key challenge and convergent theme across chemistry, biology, and materials science. The last couple of decades have witnessed ultrafast electron diffraction (UED) emerge as one of the forefront techniques with the sensitivity to resolve atomic motions. Increasingly sophisticated UED instruments are being developed that are aimed at increasing the beam brightness in order to observe structural signatures, but so far they have been limited to low average current beams. Here, we present the technical design and capabilities of the HiRES (High Repetition-rate Electron Scattering) instrument, which blends relativistic electrons and high repetition rates to achieve orders of magnitude improvement in average beam current compared to the existing state-of-the-art instruments. The setup utilizes a novel electron source to deliver femtosecond duration electron pulses at up to MHz repetition rates for UED experiments. Instrument response function of sub-500 fs is demonstrated with < 100 fs time resolution targeted in future. We provide example cases of diffraction measurements on solid-state and gas-phase samples, including both micro- and nanodiffraction (featuring 100 nm beam size) modes, which showcase the potential of the instrument for novel UED experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Structure and ultrafast dynamics of tri-nuclear Ag-/Tl–Pt 2 POP 4 complexes in solution

The energetics and dynamics of ion assembly in solution has broad influence in nanomaterials and inorganic synthesis. To investigate the fundamental processes involved, we present a time-resolved x-ray solution scattering (TR-XSS) study of the trinuclear silver and thallium complexes of the diplatinum ion PtPOP [Pt 2 (H 2 P 2 O 5 )$_4^{4−}$] in aqueous solution. These complexes, their structural properties, and their electronic structure are not well understood and afford a unique opportunity to study the metal–metal bond formation that influences molecular and material assembly in solution. We present model-independent analysis of the observed dynamics as well as an analysis incorporating time-resolved structural refinements of key bond lengths with $<$100 fs time resolution. We find that upon photoexcitation, the Pt atoms contract ∼0.25 Å toward the center of both the Ag- and the Tl-PtPOP complexes, as previously observed for the PtPOP anion. For the AgPtPOP system, an ultrafast Ag-Pt bond expansion of ∼0.2 Å is observed, whereas in contrast, the TlPtPOP system exhibits a Tl-Pt bond contraction of ∼0.3 Å upon photoexcitation. For both complexes, the change in electronic state leads to coherent (“wave-packet”) oscillations along the metal–Pt coordinates. Based on these structural dynamics, we propose an electronic structure model that describes the metal–metal bonding behavior in both the ground and excited state for both complexes.

Lenzen, Philipp [Technical Univ. of Denmark, Lyngb↗

The Scattered Light Time-history Diagnostic suite at the National Ignition Facility

The Scattered Light Time-history Diagnostic (SLTD) is being implemented at the National Ignition Facility (NIF) to greatly expand the angular coverage of absolute scattered-light measurements for direct- and indirect-drive inertial confinement fusion (ICF) experiments. The SLTD array will ultimately consist of 15 units mounted at a variety of polar and azimuthal angles on the NIF target chamber, complementing the existing NIF backscatter suite. Each SLTD unit collects and diffuses scattered light onto a set of three optical fibers, which transport the light to filtered photodiodes to measure scattered light in different wavelength bands: stimulated Brillouin scattering (350 nm–352 nm), stimulated Raman scattering (430 nm–760 nm), and ω/2 (695 nm–745 nm). SLTD measures scattered light with a time resolution of ~1 ns and a signal-to-noise ratio of up to 500. Currently, six units are operational and recording data. Measurements of the angular dependence of scattered light will strongly constrain models of laser energy coupling in ICF experiments and allow for a more robust inference of the total laser energy coupled to implosions.

47 OTHER INSTRUMENTATION↗

Multi-energy calibration of a PILATUS3 CdTe detector for hard x-ray measurements of magnetically confined fusion plasmas

A multi-energy hard x-ray pin-hole camera based on the PILATUS3 X 100K-M CdTe detector has been developed at the Princeton Plasma Physics Laboratory for installation on the Tungsten Environment in Steady State Tokamak. This camera will be employed to study thermal plasma features such as electron temperature as well as non-thermal effects such as fast electron tails produced by a lower hybrid radiofrequency current drive and the birth of runaway electrons. The innovative aspect of the system lies in the possibility of setting the threshold energy independently for each of the ~100k pixels of the detector. This feature allows for the measurement of the x-ray emission in multiple energy ranges with adequate space and time resolution (~1 cm, 2 ms) and coarse energy resolution. In this work, the energy dependence of each pixel was calibrated within the range 15 keV–100 keV using a tungsten x-ray tube and emission from a variety of fluorescence targets (from yttrium to uranium). The data corresponding to pairs of K α emission lines are fit to the characteristic responsivity (“S-curve”), which describes the detector sensitivity across the 64 possible energy threshold values for each pixel; this novel capability is explored by fine-tuning the voltage of a six-bit digital-analog converter after the charge-sensitive amplifier for each of the ~100k pixels. Here, this work presents the results of the calibration including a statistical analysis. It was found that the achievable energy resolution is mainly limited by the width of the S-curve to 3 keV–10 keV for threshold energies up to 50 keV, and to ≥20 keV for energies above 60 keV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A multi-channel x-ray temporal diagnostic for measurement of time-resolved electron temperature in cryogenic deuterium–tritium implosions at OMEGA

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as Te is unaffected by residual flows and other non-thermal effects unlike ion temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The proposed diagnostic utilizes five fast-rise (~15 ps) scintillator channels with distinct x-ray filtering. Furthermore, titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10 keV–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons. Initial data collected using a prototype nosecone on the existing neutron temporal diagnostic demonstrate the validity of this diagnostic technique. The proposed system will be capable of measuring spatially integrated T e (t) with 20 ps time resolution and <10% uncertainty at peak emission in cryogenic DT implosions.

47 OTHER INSTRUMENTATION↗

Two-photon absorption laser induced fluorescence measurements of absolute neutral deuterium density, temperature, and bulk flow in Proto-MPEX

Neutral particle control is critical for fusion fueling and confinement. Neutral diagnostics for fusion-relevant plasmas are commonly restricted to line-integrated or ex situ methods. A non-perturbative, two-photon absorption laser induced fluorescence (TALIF) diagnostic is implemented on the Prototype Material Plasma Exposure eXperiment (Proto-MPEX) to probe neutral atomic deuterium in a fusion-relevant plasma at 1 cm intervals along the radius of the vacuum vessel. The diagnostic is situated ~20 m from the vacuum vessel, and a signal is collected along the laser injection axis, requiring only one line-of-sight. TALIF measurements are absolutely calibrated using xenon and krypton. Absolute atomic densities derived from xenon calibration are compared to absolute atomic densities derived from krypton calibration. In this work, preliminary measurements of absolute atomic deuterium density, temperature, and local bulk flow dependence on radial location and input power in Proto-MPEX are presented. Neutral atomic deuterium velocity distribution functions are measured throughout a one-second plasma pulse with a time resolution of 250 ms.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Femtosecond ultraviolet laser absorption spectroscopy for simultaneous measurements of temperature and OH concentration

This Letter reports a femtosecond ultraviolet laser absorption spectroscopy (fs-UV-LAS) for simultaneous in situ measurements of temperature and species. Here, this fs-UV-LAS technique was demonstrated based on X 2 Π-A 2 Σ + transitions of OH radicals near 308 nm generated in low temperature plasmas and flames. The fs-UV-LAS technique has revealed three major diagnostic benefits. First, a series of absorption features within a spectral bandwidth of ~3.2 nm near 308 nm were simultaneously measured and then enabled simultaneous multi-parameter measurements with enhanced accuracy. The results show that the temperature and OH concentration could be measured with accuracy enhanced by 29–88% and 58–91%, respectively, compared to those obtained with past two-narrow-line absorption methods. Second, an ultrafast time resolution of ~120 picoseconds was accomplished for the measurements. Third, due to the large OH X 2 Π-A 2 Σ + transitions in the UV range, a simple single-pass absorption with a 3-cm path length was allowed for measurements in plasmas with low OH number density down to ~2 × 10 13 cm –3 . Also due to the large OH UV transitions, single-shot fs absorption measurements were accomplished in flames, which was expected to offer more insights into chemically reactive flow dynamics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Constraining time-dependent ion temperature measurements in inertial confinement fusion (ICF) implosions with an intermediate distance neutron time-of-flight (nToF) detector

A concept for using an intermediate distance (0.3–3.0 m) neutron time-of-flight (nToF) to provide a constraint on the measurement of the time-dependence of ion temperature in inertial confinement fusion implosions is presented. Simulated nToF signals at different distances are generated and, with a priori knowledge of the burn-averaged quantities and burn history, analyzed to determine requirements for a future detector. Results indicate a signal-to-noise ratio >50 and time resolution <20 ps to constrain the ion temperature gradient to ∼±25% (0.5 keV/100 ps).

Moore, A. S. (ORCID:0000000221258882)↗

The phase-2 particle x-ray temporal diagnostic for simultaneous measurement of multiple x-ray and nuclear emission histories from OMEGA implosions (invited)

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as T e is negligibly affected by residual flows and other non-thermal effects unlike ion-temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The newly implemented phase-2 Particle X-ray Temporal Diagnostic (PXTD) utilizes four fast-rise (~15 ps) scintillator-channels with distinct x-ray filtering. Titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons (DTn) from OMEGA Cryo-DT implosions. High quality data have been collected from warm implosions at OMEGA. These data have been used to infer spatially integrated T e (t) with <10% uncertainty at peak emission. Nuclear and x-ray emission histories are measured with 10 ps relative timing uncertainty for x rays and DTn and 12 ps for x rays and deuterium- 3 He protons (D 3 Hep). A future upgrade to the system will enable spatially integrated T e (t) with 40 ps time-resolution from cryogenic DT implosions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Monte Carlo technique to model performance of streak camera-based time-resolving x-ray spectrometers

A Monte Carlo technique has been developed to simulate the expected signal and the statistical noise of x-ray spectrometers that use streak cameras to achieve the time resolution required for ultrafast diagnostics of laser-generated plasmas. The technique accounts for statistics from both the photons incident on the streak camera’s photocathode and the electrons emitted by the photocathode travelling through the camera’s electron optics to the sensor. We use the technique to optimize the design of a spectrometer, which deduces the temporal history of electron temperature of the hotspot in an inertial confinement fusion implosion from its hard x-ray continuum emission spectra. The technique is general enough to be applied to any instrument using an x-ray streak camera.

Stoupin, S. (ORCID:0000000226225270)↗

Local measurements of the pedestal magnetic field profile throughout the ELM cycle on DIII-D

We report new high speed localized measurements of the pedestal magnetic field during the edge localized mode (ELM) cycle of a DIII-D High confinement mode (H-mode) discharge indicate a temporally and spatial complex redistribution of the edge current density profile, $j_{edge}$. The measurement technique extracts the magnetic field magnitude, $\textit{B}$, via the spectral separation of Stark-split neutral beam radiation in the pedestal. Single spatial channel measurements from a novel spatial heterodyne spectrometer are validated in discharges with core current profile changes. The technique measures Stark-splitting changes that imply $\textit{B}$ changes as small as 1 mT with high time resolution (50 μs). At normalized poloidal flux $ψ_n$ = 1.0, $\textit{B}$ appears saturated in the inter-ELM period and then rapidly decreases in <200 μs by ~1%, before edge recycling emission begins to increase. Radially inboard of $j_{edge}$, $\textit{B}$ increases at the ELM crash. The behavior is consistent with a rapid collapse of $j_{edge}$ at the ELM crash and subsequent pedestal recovery. In some discharges, at $ψ_n$ < 0.96, changes in $\textit{B}$ are observed throughout the ELM cycle. In others, $\textit{B}$ recovers and is relatively stable until a few ms leading up to the next crash. Measurements of $\textit{B}$ during the H-mode transition show a large increase at $ψ_n$ = 1 with little change at $ψ_n$ = 0.9, consistent with the formation of the edge bootstrap current density peak. The $ψ_n$ = 0.9 spectrum is complicated by predicted changes to the Stark component intensities with density at the L–H transition.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Cinematic reflectometry using QIKR, the quite intense kinetics reflectometer

The Quite Intense Kinetics Reflectometer (QIKR) will be a general-purpose, horizontal-sample-surface neutron reflectometer. Reflectometers measure the proportion of an incident probe beam reflected from a surface as a function of wavevector (momentum) transfer to infer the distribution and composition of matter near an interface. The unique scattering properties of neutrons make this technique especially useful in the study of soft matter, biomaterials, and materials used in energy storage. Exploiting the increased brilliance of the Spallation Neutron Source Second Target Station, QIKR will collect specular and off-specular reflectivity data faster than the best existing such machines. It will often be possible to collect complete specular reflectivity curves using a single instrument setting, enabling “cinematic” operation, wherein the user turns on the instrument and “films” the sample. Samples in time-dependent environments (e.g., temperature, electrochemical, or undergoing chemical alteration) will be observed in real time, in favorable cases with frame rates as fast as 1 Hz. Cinematic data acquisition promises to make time-dependent measurements routine, with time resolution specified during post-experiment data analysis. This capability will be deployed to observe such processes as in situ polymer diffusion, battery electrode charge–discharge cycles, hysteresis loops, and membrane protein insertion into lipid layers.

47 OTHER INSTRUMENTATION↗

Gas puff imaging on the TCV tokamak

We present the design and operation of a suite of Gas Puff Imaging (GPI) diagnostic systems installed on the Tokamak à Configuration Variable (TCV) for the study of turbulence in the plasma edge and Scrape-Off-Layer (SOL). These systems provide the unique ability to simultaneously collect poloidal 2D images of plasma dynamics at the outboard midplane, around the X-point, in both the High-Field Side (HFS) and Low-Field Side (LFS) SOL, and in the divertor region. We describe and characterize an innovative control system for deuterium and helium gas injection, which is becoming the default standard for the other gas injections at TCV. Extensive pre-design studies and the different detection systems are presented, including an array of avalanche photodiodes and a high-speed CMOS camera. First results with spatial and time resolutions of up to ≈2 mm and 0.5 µs, respectively, are described, and future upgrades of the GPI diagnostics for TCV are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Novel angular velocity estimation technique for plasma filaments

Magnetic field aligned filaments such as blobs and edge localized mode filaments carry significant amounts of heat and particles to the plasma facing components and they decrease their lifetime. The dynamics of these filaments determine at least a part of the heat and particle loads. These dynamics can be characterized by their translation and rotation. In this paper, we present an analysis method novel for fusion plasmas, which can estimate the angular velocity of the filaments on frame-by-frame time resolution. After pre-processing, the frames are two-dimensional (2D) Fourier-transformed, then the resulting 2D Fourier magnitude spectra are transformed to log-polar coordinates, and finally the 2D cross-correlation coefficient function (CCCF) is calculated between the consecutive frames. The displacement of the CCCF’s peak along the angular coordinate estimates the angle of rotation of the most intense structure in the frame. Further, the proposed angular velocity estimation method is tested and validated for its accuracy and robustness by applying it to rotating Gaussian-structures. The method is also applied to gas-puff imaging measurements of filaments in National Spherical Torus Experiment plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗