Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolved imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Degradation Dynamics of Perovskite Solar Cells Under Fixed Reverse Current Injection

Previous studies of reverse-bias stability in perovskite solar cells have focused primarily on voltage controlled reverse-bias tests. Here we instead present an investigation of perovskite solar cell degradation under well-defined, constant reverse-current stress. We show that the choice of hole-transport layer dictates the dominant degradation pathway: cells using thick poly(triphenylamine) (PTAA) layers with better indium-doped tin oxide (ITO) coverage can tolerate high reverse bias but quickly undergo catastrophic breakdown under fixed reverse current near their one-sun maximum power-point. In contrast, cells modified with the phosphonic-acid interface layer MeO-2PACz, with poorer ITO coverage compared to PTAA, exhibit soft, gradual, and largely recoverable degradation, regardless of the shading conditions. For MeO-2PACz devices, degradation increases with both current magnitude and duration. Importantly, when normalized by injected charge (current times duration), lower currents applied over longer times cause more severe degradation than higher currents over shorter periods. Combining electrical measurements with spatially resolved photoluminescence imaging, we argue against shunt formation and instead support an ion- and charge-mediated interfacial electrochemical degradation mode.

Applied Physics (physics.app-ph)↗

Remote sensing; Proceedings of the Meeting, Orlando, FL, Apr. 3, 4, 1986

Advances in optical technology for remote sensing are discussed in reviews and reports of recent experimental investigations. Topics examined include industrial applications, laser diagnostics for combustion research, laser remote sensing for ranging and altimetry, and imaging systems for terrestrial remote sensing from space. Consideration is given to LIF in forensic diagnostics, time-resolved laser-induced-breakdown spectrometry for rapid analysis of alloys, CARS in practical combustion environments, airborne inertial surveying using laser tracking and profiling techniques, earth-resources instrumentation for the EOS polar platform of the Space Station, and the SAR for EOS.

Menzies, Robert T.↗

A Study of Planetary System Formation and Evolution Using a Dual Channel Adaptive Optics Imaging Polarimeter

The award I received from the Graduate Student Research Program in 2001, and the renewal award in 2002, supported the gathering and processing of my thesis data, and the presentation of my scientific results at astronomy conferences. Ultimately, this led to a successful defense of my PhD thesis. In the thesis work, I built, calibrated, and observed with the first dual imaging polarimeter ever used in series with a high order adaptive optics system and on an 8 meter class telescope. The instrument was arguably the most sensitive instrument for the high-contrast detection of the scattered light from circumstellar disks. The success of the instrument has provided the impetus for the construction of several similar simultaneous adaptive optics imaging polarimeters. In the course of the observations, a number of circumstellar disks were resolved for the first time in their scattered light, such as the disk around the classical T-tauri stars, LkCa 15 and LkHa 262. A sample of 24 young, nearby, solar-analog stars were observed with the instrument in search of the scattered light signature from debris disks around these stars. Although none of the stars revealed any obvious scattered light signatures, a meaningful limit was placed on the dust population around these stars. Also, a brown dwarf binary system was found to be a companion to one of the solar-analog stars observed, HD130948. A careful monitoring of the orbit of the binary brown dwarf will result in a dynamical mass determination of the objects, providing a valuable calibration of the physical models explaining brown dwarf evolution.

Potter, Daniel E.↗

Satellites for long-term monitoring of inland U.S. lakes: The MERIS time series and application for chlorophyll-a

Lakes and other surface fresh waterbodies provide drinking water, recreational and economic opportunities, food, and other critical support for humans, aquatic life, and ecosystem health. Lakes are also productive ecosystems that provide habitats and influence global cycles. Chlorophyll concentration provides a common metric of water quality, and is frequently used as a proxy for lake trophic state. Here, we document the generation and distribution of the complete MEdium Resolution Imaging Spectrometer (MERIS; Appendix A provides a complete list of abbreviations) radiometric time series for over 2300 satellite resolvable inland bodies of water across the contiguous United States (CONUS) and more than 5,000 in Alaska. This contribution greatly increases the ease of use of satellite remote sensing data for inland water quality monitoring, as well as highlights new horizons in inland water remote sensing algorithm development. We evaluate the performance of satellite remote sensing Cyanobacteria Index (CI)-based chlorophyll algorithms, the retrievals for which provide surrogate estimates of phytoplankton concentrations in cyanobacteria dominated lakes. Our analysis quantifies the algorithms' abilities to assess lake trophic state across the CONUS. As a case study, we apply a bootstrapping approach to derive a new CI-to-chlorophyll relationship, ChlBS, which performs relatively well with a multiplicative bias of 1.11 (11%) and mean absolute error of 1.60 (60%). While the primary contribution of this work is the distribution of the MERIS radiometric timeseries, we provide this case study as a roadmap for future stakeholders' algorithm development activities, as well as a tool to assess the strengths and weaknesses of applying a single algorithm across CONUS.

MERIS timeseries↗

Time-domain modelling and thermometry of the CH 4 v 1 Q-branch using hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering

Here, we present time-domain measurements and modelling of the CH 4 v 1 vibrational Q-branch, as well as simultaneous temperature acquisition from the CH 4 and N 2 vibrational Q-branches using broadband hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS). Accurate measurements with fs/ps CARS require knowledge of the time-domain response of the probed molecule at different temperatures and pressures. In this work, a fs/ps CARS model was developed for theCH 4 v 1 Q-branch and validated using time-resolved probe delay scans at pressures between 70 and 600 Torr and temperatures between 295 and 1000 K. A simplified modified exponential energy gap model was used to determine the linewidths of the Raman transitions within the Q-branch. Total Q-branch linewidths for the entire explored parameter space were also determined from the probe delay scans. This enabled quantitative measurements of CH 4 with fs/ps CARS as well as the temperature through the hot bands of the CH 4 v 1 Q-branch. With a broadband fs laser pulse in a two-beam phase matching scheme, the N 2 Q-branch and CH 4 v 1 Q-branch were simultaneously measured in a heated cell, and the temperatures from each molecule's spectra was evaluated. Here, the fitted temperatures corresponded well with differences ranging from 4 to 17%. It was also shown that exchanging 90% of CH 4 for N 2 or Ar at 295 K and 500 Torr did not significantly impact the normalized time-domain signal prior to a 100 picosecond probe delay. Spatially resolved one-dimensional (1-D) thermometry using the CH 4 Q-branch was also demonstrated with an imaged spatial resolution of 40 µm. With the developed model, 1-D quantitative measurements of CH 4 concentration and temperature can be measured with time resolution of tens of picoseconds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tracking Dendritic Growth in Hydrogen-Based Hematite Reduction via Computer Vision

The reduction of hematite to metallic iron using hydrogen (H2) as a reducing agent presents a promising pathway for decarbonizing steel production. In this study, we employ a combination of in situ confocal scanning laser microscopy (CSLM) and advanced computer vision techniques to quantitatively analyze dendritic growth of ferrite during H2-based reduction of iron oxide at high temperatures. A workflow integrating Watershed Image Segmentation (WIS) and Lucas-Kanade Optical Flow (LKOF) is developed to extract both global and local kinetic information from time-resolved micrograph sequences. H2 reduction experiments conducted at 1400 degrees C and 1500 degrees C demonstrate a clear correlation between temperature and reduction rate, as evidenced by accuracy of fitted Johnson-Mehl-Avrami-Kolmogorov (JMAK) parameters. Optical flow analysis further elucidates the anisotropic and branched nature of dendritic growth, providing spatially resolved velocity fields that correlate well with global transformation kinetics. The proposed methodology demonstrates strong agreement with experimental measurements and literature values, offering a robust framework for automated image-based analysis to study kinetics through microstructural evolution in the reduction of iron ore, and likely other reaction-diffusion phenomena.

08 HYDROGEN↗

Planar shock-induced bubble collapse and jetting in water captured via X-ray phase contrast imaging

Shock wave–bubble interactions in water manifest rich dynamics driven by a combination of strong pressure and density mismatches. They have a wide variety of applications, including the injection of pharmaceuticals, and through scaling, enable the exploration of various aspects of high-energy-density systems such as inertial confinement fusion. In this work, the interaction between a micrometric nitrogen bubble and a planar shock wave, characterized by a Mach number of M = 1.24 and a peak pressure of p max = 0.57 , is experimentally recorded using ultra-high-speed x-ray phase contrast imaging. Highly resolved radiographs provide access to all phase discontinuities along the beam path, offering quantities such as the time-varying bubble size, the speed of a jet produced during the bubble collapse, and the time evolution of the shock wave front, which are critical benchmark data for numerical scheme validation. This study addresses the lack of well-characterized, repeatable, and high spatiotemporal resolution experiments at negative Atwood numbers by providing shock–bubble visualization and corresponding numerical simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

macroMS: Image-Guided Analysis of Random Objects by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

Mass spectrometry imaging is well-suited to characterizing sample surfaces for their chemical content in a spatially resolved manner. However, when the surface contains small objects with significant empty spaces between them, more efficient approaches to sample acquisition are possible. Image-guided mass spectrometry (MS) enables high-throughput analysis of a diverse range of sample types, such as microbial colonies, liquid microdroplets, and others, by recognizing and analyzing selected location targets in an image. Here, we describe an imaging protocol and macroMS, an online software suite that can be used to enhance MS measurements of macroscopic samples that are imaged by a camera or a flatbed scanner. Furthermore, the web-based tool enables users to find and filter targets from the optical images, correct optical distortion issues for improved spatial location of selected targets, input the custom geometry files into an MS device to acquire spectra at the selected locations, and finally, perform limited data analysis and use visualization tools to aid locating samples containing compounds of interest. Using the macroMS suite, an enzyme mutant library of Saccharomyces cerevisiae and nL droplet arrays of Escherichia coli and Pseudomonas fluorescens have been assayed at a rate of ~2 s/sample.

47 OTHER INSTRUMENTATION↗

Utilizing the Precessing Orbit of TRMM to Produce Hourly Corrections of Geostationary Infrared Imager Data with the VIRS Sensor

Accurate characterization of the Earth's radiant energy is critical for many climate monitoring and weather forecasting applications. For example, groups at the NASA Langley Research Center rely on stable visible- and infrared-channel calibrations in order to understand the temporal/spatial distribution of hazardous storms, as determined from an automated overshooting convective top detection algorithm. Therefore, in order to facilitate reliable, climate-quality retrievals, it is important that consistent calibration coefficients across satellite platforms are made available to the remote sensing community, and that calibration anomalies are recognized and mitigated. One such anomaly is the infrared imager brightness temperature (BT) drift that occurs for some Geostationary Earth Orbit satellite (GEOsat) instruments near local midnight. Currently the Global Space-Based Inter-Calibration System (GSICS) community uses the hyperspectral Infrared Atmospheric Sounding Interferometer (IASI) sensor as a common reference to uniformly calibrate GEOsat IR imagers. However, the combination of IASI, which has a 21:30 local equator crossing time (LECT), and hyperspectral Atmospheric Infrared Sounder (AIRS; 01:30 LECT) observations are unable to completely resolve the GEOsat midnight BT bias. The precessing orbit of the Tropical Rainfall Measuring Mission (TRMM) Visible and Infrared Scanner (VIRS), however, allows sampling of all local hours every 46 days. Thus, VIRS has the capability to quantify the BT midnight effect observed in concurrent GEOsat imagers. First, the VIRS IR measurements are evaluated for long-term temporal stability between 2002 and 2012 by inter-calibrating with Aqua-MODIS. Second, the VIRS IR measurements are assessed for diurnal stability by inter-calibrating with Meteosat-9 (Met-9), a spin-stabilized GEOsat imager that does not manifest any diurnal dependency. In this case, the Met-9 IR imager is first adjusted with the official GSICS calibration coefficients. Then VIRS is used as a diurnal calibration reference transfer to produce hourly corrections of GEOsat IR imager BT. For the 9 three-axis stabilized GEO imagers concurrent with VIRS, the midnight effect increased the BT on average by 0.5 K (11 microns) and 0.4 K (12 microns), with a peak at approx.01:00 local time. As expected, the spin-stabilized GEOsats revealed a smaller diurnal temperature cycle (mostly < 0.2 K) with inconsistent peak hours.

Scarino, Benjamin↗

Characterization of a Low-Temperature Plasma (LTP) Ambient Ionization Source Using Temporally Resolved Monochromatic Imaging Spectrometry

The low-temperature plasma (LTP) probe is a common plasma-based source used for ambient desorption–ionization mass spectrometry (MS). While the LTP probe has been characterized in detail with MS, relatively few studies have used optical spectroscopy. In this paper, two-dimensional (2D) imaging at selected wavelengths is used to visualize important species in the LTP plasma jet. First, 2D steady-state images of the LTP plume for N 2 + (391.2 nm), He I (706.5 nm), and N 2 (337.1 nm) emissions were recorded under selected plasma conditions. Second, time-resolved 2D emission maps of radiative species in the LTP plasma jet were recorded through the use of a 200 ns detection gate and varying gate delays with respect to the LTP trigger pulse. Emission from He I, N 2 + , and N 2 in the plasma jet region was found to show a transient behavior (often referred to as plasma bullets) lasting only a few microseconds. The N 2 + and He I maps were highly correlated in spatial and temporal structure. Further, emission from N 2 showed two maxima in time, one before and one after the maximum emission for N 2 + and He I, due to an initial electronic excitation wave and ion–electron recombination, respectively. Third, the interaction of the LTP probe with a sample substrate and an electrically grounded metallic needle was studied. Emission from a fluorophore on the sample substrate showed an initial photon-induced excitation from plasma-generated photons followed by electronic excitation by other plasma species. The presence of a grounded needle near the plasma jet significantly extended the plasma jet lifetime and also generated a long-lived corona discharge on the needle. The effect of LTP operating parameters on emission spectra was correlated with mass-spectral results including reagent-ion signals. Lastly, five movies provide a side-by-side comparison of the temporal behavior of emitting species and insights into the interactions of the emission clouds with a sample surface as well as an external needle. Temporally and spatially resolved imaging provided insights into important processes in the LTP plasma jet, which will help improve analyte ion sampling in LTP–MS.

Chan, George C. -Y.↗

The next-generation particle x-ray temporal diagnostic for simultaneous time-resolved measurements of nuclear-burn and x-ray emission histories in support of basic-science and inertial confinement fusion experiments at OMEGA

The next-generation Particle X-ray Temporal Diagnostic (PXTD) has been implemented for simultaneous measurements of x-ray, charged particle, and neutron emission histories from a wide range of inertial confinement fusion and high energy density plasma experiments, demonstrating excellent timing accuracy and greatly improved experimental flexibility. The key changes to the previously fielded system are a redesigned set of thin foil filters in front of the scintillators and individual neutral density filters for each region of the detector. The fully implemented PXTD system can provide unique information about the evolution of ion and electron temperatures in multi-ion and kinetic-physics experiments, proton radiography experiments, and DT experiments executed at the OMEGA facility. The system has 35 ps time resolution and negligible relative timing uncertainty between measured emission history signals. The first use of the upgraded four-channel PXTD system during a set of D 3 He-filled silica-glass implosions on OMEGA captured electron temperatures with a minimum uncertainty of 0.5 keV and resolved both the relative timings and widths of neutron, proton, and x-ray peaks within a single recorded image.

Evans, T. E. [Massachusetts Inst. of Technology (M↗

Visualization of Secondary Flow Development in High Aspect Ratio Channels with Curvature

The results of an experimental project to visually examine the secondary flow structure that develops in curved, high aspect-ratio rectangular channels are presented. The results provide insight into the fluid dynamics within high aspect ratio channels. A water flow test rig constructed out of plexiglass, with an adjustable aspect ratio, was used for these experiments. Results were obtained for a channel geometry with a hydraulic diameter of 10.6 mm (0.417 in.), an aspect ratio of 5.0, and a hydraulic radius to curvature radius ratio of 0.0417. Flow conditions were varied to achieve Reynolds numbers up to 5,100. A new particle imaging velocimetry technique was developed which could resolve velocity information from particles entering and leaving the field of view. Time averaged secondary flow velocity vectors, obtained using this velocimetry technique, are presented for 30 degrees, 60 degrees, and 90 degrees into a 180 degrees bend and at a Reynolds number of 5,100. The secondary flow results suggest the coexistence of both the classical curvature induced vortex pair flow structure and the eddies seen in straight turbulent channel flow.

Meyer, Michael L.↗

Preliminary Design of a Lightning Optical Camera and ThundEr (LOCATE) Sensor

The preliminary design of an optical/acoustical instrument is described for making highly accurate real-time determinations of the location of cloud-to-ground (CG) lightning. The instrument, named the Lightning Optical Camera And ThundEr (LOCATE) sensor, will also image the clear and cloud-obscured lightning channel produced from CGs and cloud flashes, and will record the transient optical waveforms produced from these discharges. The LOCATE sensor will consist of a full (360 degrees) field-of-view optical camera for obtaining CG channel image and azimuth, a sensitive thunder microphone for obtaining CG range, and a fast photodiode system for time-resolving the lightning optical waveform. The optical waveform data will be used to discriminate CGs from cloud flashes. Together, the optical azimuth and thunder range is used to locate CGs and it is anticipated that a network of LOCATE sensors would determine CG source location to well within 100 meters. All of this would be accomplished for a relatively inexpensive cost compared to present RF lightning location technologies, but of course the range detection is limited and will be quantified in the future. The LOCATE sensor technology would have practical applications for electric power utility companies, government (e.g. NASA Kennedy Space Center lightning safety and warning), golf resort lightning safety, telecommunications, and other industries.

Phanord, Dieudonne D.↗

Suzaku Reveals He-burning Products in the X-ray Emitting Planetary Nebula BD +30deg 3639

BD +30deg 3639, the brightest planetary nebula at X-ray energies, was observed with Suzaku, an X-ray observatory launched on 2005 July 10. Using the X-ray Imaging Spectrometer, the K-lines from C VI, O VII, and O VIII were resolved for the first time, and C/O, N/O, and Ne/O abundance ratios determined. The C/O abundance ratio exceeds the solar value by nearly two orders of magnitude, and that of Ne/O by at least a factor of 5. These results indicate that the X-rays are emitted mainly by helium shell-burning products.

Murashima, M.↗

Selective Dynamical Imaging of Interferometric Data

Recent developments in very long baseline interferometry (VLBI) have made it possible for the Event Horizon Telescope (EHT) to resolve the innermost accretion flows of the largest supermassive black holes on the sky. The sparse nature of the EHT’s (u, v)-coverage presents a challenge when attempting to resolve highly time-variable sources. We demonstrate that the changing (u, v)-coverage of the EHT can contain regions of time over the course of a single observation that facilitate dynamical imaging. These optimal time regions typically have projected baseline distributions that are approximately angularly isotropic and radially homogeneous. We derive a metric of coverage quality based on baseline isotropy and density that is capable of ranking array configurations by their ability to produce accurate dynamical reconstructions. We compare this metric to existing metrics in the literature and investigate their utility by performing dynamical reconstructions on synthetic data from simulated EHT observations of sources with simple orbital variability. We then use these results to make recommendations for imaging the 2017 EHT Sgr A* data set.

79 ASTRONOMY AND ASTROPHYSICS↗

High-resolution analogue of time-domain phonon spectroscopy in the transmission electron microscope

Femtosecond photoexcitation of semiconducting materials leads to the generation of coherent acoustic phonons (CAPs), the behaviours of which are linked to intrinsic and engineered electronic, optical and structural properties. While often studied with pump-probe spectroscopic techniques, the influence of nanoscale structure and morphology on CAP dynamics can be challenging to resolve with these all-optical methods. Here, we used ultrafast electron microscopy (UEM) to resolve variations in CAP dynamics caused by differences in the degree of crystallinity in as-prepared and annealed GaAs lamellae. Following in situ femtosecond photoexcitation, we directly imaged the generation and propagation dynamics of hypersonic CAPs in a mostly amorphous and, following an in situ photothermal anneal, a mostly crystalline lamella. Subtle differences in both the initial hypersonic velocities and the asymptotic relaxation behaviours were resolved via construction of space-time contour plots from phonon wavefronts. Comparison to bulk sound velocities in crystalline and amorphous GaAs reveals the influence of the mixed amorphous-crystalline morphology on CAP dispersion behaviours. Further, an increase in the asymptotic velocity following annealing establishes the sensitivity of quantitative UEM imaging to both structural and compositional variations through differences in bonding and elasticity. Lastly, implications of extending the methods and results reported here to elucidating correlated electronic, optical and structural behaviours in semiconducting materials are discussed.

42 ENGINEERING↗

Optical imaging spectroscopy

During the recent solar maximum the combination of imaging and spectroscopy in the visible part of the spectrum became a powerful tool for observational study of flares primarily because of the development of two-dimensional charge-coupled-device (CCD) arrays. In combination with appropriate new operational methods, this has led to the ability to observe, for the first time, the preflare and impulsive-phase physical processes associated with spatially resolved features of flare loops. As a result of concurrent theoretical developments, modeling progressed from an empirical to a physical level. This made it possible to interpret imaging spectra in terms of coronal pressure and heat flux, particle beam heating, chromospheric evaporation, and explosive chromospheric dynamics at the footpoints of flare loops. There is clear potential for further advances in the near future, taking advantage of improvements in digital recording speed (approx. 10-fold), number of photosensitive elements per array (approx. 10-fold), real-time data pre-reduction (potentially 10- to 100-fold), and using multiple CCD arrays. By the time of the next solar maximum imaging spectroscopy is expected to achieve spatial resolution or approx. arc 1 arc s, temporal resolution or approx. 5 s, and simultaneous critically-sampled spectroscopy of several lines and continua. As a result, continued increase in our understanding of the physical processes and configurations of solar flares in the chromosphere, temperature minimum region, and photosphere can be anticipated. Even greater progress toward a more global understanding of flares will obviously come about when simultaneous optical, X-ray, and gamma-ray imaging spectroscopy are possible.

Canfield, R. C.↗

Exploring Cosmic X-ray Source Polarization

Cosmic X-ray sources are expected to be polarized, either because of their asymmetry and the role of scattering in their emission or the role of magnetic fields. Polarization at other wavelengths has been useful. X-ray polarization will provide a new handle on black hole parameters, in particular the spin, on accretion flows and outflows, on neutron star spin orientations and emission mechanisms, on the quantum mechanical effects of super-strong magnetic fields of magnetars, and on the structure of supernovae shocks. The proposed Gravity and Extreme Magnetism SMEX (GEMS) will use high efficiency polarimeters behind thin foil mirrors. The statistical sensitivity and control of systematics will allow measurement of polarization fractions as small as 1% from many galactic and extragalactic sources. Targets which should be polarized at the level that GEMS can easily measure include stellar black holes, Seyfert galaxies and quasars, blazars, rotation-powered and accretion-powered pulsars, magnetars, shell supernova remnants and pulsar wind nebulae. The polarimeters are Time Projection Chambers that allow reconstruction of images of photoelectron tracks for 2-10 keV Xrays. They can be deep without sacrificing modulation. These polarimeters do not image the sky, but the telescope point spread function and detector collimation allow structure to be resolved at the 10 arcmin level. Rotation of the spacecraft is not needed for the signal measurement in the Time Projection Chambers, but provides for measurement and correction of systematic errors. It also allows a small Bragg reflection soft X-ray experiment to be included that can be used for isolated neutron stars and blazars.

Swank, Jean Hebb↗