Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transmission Electron Microscopy (TEM)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Tritium Aging Effects on Fracture Toughness of Stainless Steel Weldments

The long-term embrittlement effects of tritium and decay helium on the structural properties of stainless steels have been studied for years at Savannah River to provide required data for establishing safe operating conditions and lifetimes of pressure vessels used to contain tritium gas. In this study, the fracture toughness properties of the longest-aged tritium-precharged stainless-steel base metals and weldments tested at Savannah River were measured and compared to earlier results. The fracture toughness values were the lowest recorded here for tritium-exposed stainless steel. As-forged and as-welded specimens were thermally precharging with tritium gas at 34.5 MPa and 623 K, then aged for up to 17 years to buildin decay helium prior to testing. ASTM J-Integral fracture mechanics analyses, transmission electron microscopy (TEM), and small angle neutron scattering (SANS) examinations were conducted to characterize the effects of tritium and its radioactive decay product, helium-3. Results show that the fracture toughness values were reduced to less than 2-4% of the as-forged values for specimens with more than 1300 appm helium from tritium decay. The trend of decreasing fracture toughness values with increasing helium content was consistent with earlier observations, and the data show that Type 304L stainless steel is more resistant to tritium-induced cracking than Type 21-6-9 stainless at similar decay helium levels. The fracture toughness properties of long-aged weldments were also affected, but the reductions were not as severe over time because weldments did not retain as much tritium as did the base metals. TEM observations were used to characterize the effects of decay helium bubbles on the deformation substructures, but nanometer-sized helium bubbles were not easily resolved because of high dislocation densities within the forged microstructures. SANS results are presented that suggest the technique can provide information on decay helium bubble size, spacing, and distribution in these steels.

36 MATERIALS SCIENCE↗

Asymmetric nanoparticle oxidation observed in-situ by the evolution of diffraction contrast

Abstract The use of transmission electron microscopy (TEM) to observe real-time structural and compositional changes has proven to be a valuable tool for understanding the dynamic behavior of nanomaterials. However, identifying the nanoparticles of interest typically require an obvious change in position, size, or structure, as compositional changes may not be noticeable during the experiment. Oxidation or reduction can often result in subtle volume changes only, so elucidating mechanisms in real-time requires atomic-scale resolution or in-situ electron energy loss spectroscopy, which may not be widely accessible. Here, by monitoring the evolution of diffraction contrast, we can observe both structural and compositional changes in iron oxide nanoparticles, specifically the oxidation from a wüstite-magnetite (FeO@Fe 3 O 4 ) core – shell nanoparticle to single crystalline magnetite, Fe 3 O 4 nanoparticle. The in-situ TEM images reveal a distinctive light and dark contrast known as the ‘Ashby-Brown contrast’, which is a result of coherent strain across the core – shell interface. As the nanoparticles fully oxidize to Fe 3 O 4 , the diffraction contrast evolves and then disappears completely, which is then confirmed by modeling and simulation of TEM images. This represents a new, simplified approach to tracking the oxidation or reduction mechanisms of nanoparticles using in-situ TEM experiments.

36 MATERIALS SCIENCE↗

In-situ heating-and-electron tomography for materials research: from 3D ( In-situ 2D) to 4D ( In-situ 3D)

In-situ observation has expanded the application of transmission electron microscopy (TEM) and has made a significant contribution to materials research and development for energy, biomedical, quantum, etc. Recent technological developments related to in-situ TEM have empowered the incorporation of three-dimensional observation, which was previously considered incompatible. In this review article, we take up heating as the most commonly used external stimulus for in-situ TEM observation and overview recent in-situ TEM studies. Then, we focus on the electron tomography (ET) and in-situ heating combined observation by introducing the authors’ recent research as an example. Assuming that in-situ heating observation is expanded from two dimensions to three dimensions using a conventional TEM apparatus and a commercially available in-situ heating specimen holder, the following in-situ heating-and-ET observation procedure is proposed: (i) use a rapid heating-and-cooling function of a micro-electro-mechanical system holder; (ii) heat and cool the specimen intermittently and (iii) acquire a tilt-series dataset when the specimen heating is stopped. This procedure is not too technically challenging and can have a wide range of applications. Essential technical points for a successful 4D (space and time) observation will be discussed through reviewing the authors’ example application.

36 MATERIALS SCIENCE↗

Towards Autonomous Experiments by Connecting High Performance Microscopy with High Performance Computing

The digitization of controls, data, and analysis in microscopy is bringing the idea of autonomous microscopes closer to reality than ever before. Automated transmission electron microscopy (TEM) is already fairly routine for some experiments the only require simple repetitive tasks such as imaging biological macromolecules for single particle cryoEM [1], tilt series for electron tomography [2], and movies for crystallography [3]. The vast majority of TEM experiments are conducted completely by human operators who choose the regions of interest, optimize experimental parameters, and make decisions about data quality visually during an experiment. The field is still a long way from having completely autonomous TEMs that can adapt to sample difficulties and tune experimental parameters based on data quality and desired experimental outcomes. Part of the issue is the lack of capability for feeding information learned from on-line, live data analysis back into the on-going experiment [4]. Furthermore, this presentation will discuss current capabilities for large scale data reduction and analysis using high performance computing (i.e. supercomputing) and progress towards developing a true feed-back loop that places data analysis and theory in the experimental loop.

97 MATHEMATICS AND COMPUTING↗

Random Forest Prediction of Crystal Structure from Electron Diffraction Patterns

Transmission electron microscopy (TEM) diffraction patterns are regularly used to determine the structure of crystalline materials. Electron diffraction is the most common method to solve for unknown or partially known crystal structures, as it provides direct and interpretable feedback on the orientation of crystal grains under the beam [1]. However, it remains a challenge to determine the crystal structure of a new material or even a new phase of an existing material. Analysis of such materials commonly requires manual exploration and comparison with simulated diffraction patterns. This is often a time consuming process with no obvious start point when many similar structures are possible, and this method cannot be used to determine crystal structure or orientation from structures not included in the diffraction libraries. Therefore, we have developed a machine learning model to determine the crystal structure of a material from its electron diffraction pattern.

36 MATERIALS SCIENCE↗

Application of Weak-Beam Dark-Field STEM for Dislocation Loop Analysis

Nanoscale dislocation loops formed by irradiation can significantly contribute to both irradiation hardening and embrittlement of materials when subjected to extreme nuclear reactor environments. Here, this study explores the application of weak-beam dark-field (WBDF) scanning transmission electron microscopy (STEM) methods for quantitative irradiation-induced defect analysis in crystalline materials, with a specific focus on dislocation loop imaging and analysis. A high-purity Fe-5 wt% Cr model alloy was irradiated with 8 MeV Fe 2+ ions at 450°C to a fluence of 8.8 × 10 19 m -2 , inducing dislocation loops for analysis. While transmission electron microscopy (TEM) has traditionally been the primary tool for dislocation imaging, recent advancements in STEM technology have reignited interest in using STEM for defect imaging. This study introduces and compares three WBDF STEM methods, demonstrating their effectiveness in suppressing background contrasts, isolating defect information for dislocation loop type classification, providing finer dislocation line images for small loop analysis, and presenting inside–outside contrast for identifying loop nature. Experimental findings indicate that WBDF STEM methods surpass traditional TEM approaches, yielding clearer and more detailed images of dislocation loops. The study concludes by discussing the potential applications of WBDF STEM techniques in defect analysis, emphasizing their adaptability across various material systems beyond nuclear materials.

36 MATERIALS SCIENCE↗

Novel Focused Ion Beam Liftouts for Spatial Characterization of Spherical Biominerals With Transmission Electron Microscopy

Abstract Focused ion beam (FIB) is frequently used to prepare electron- and X-ray-beam-transparent thin sections of samples, called lamellae. Typically, lamellae are prepared from only a subregion of a sample. In this paper, we present a novel approach for FIB lamella preparation of microscopic samples, wherein the entire cross-section of the whole sample can be investigated. The approach was demonstrated using spherical, porous, and often hollow microprecipitates of biologically precipitated calcium carbonate. The microprecipitate morphology made these biogenic samples more fragile and challenging than materials commonly investigated using FIB lamellae. Our method enables the appropriate orientation of the lamellae required for further electron/X-ray analyses after attachment to the transmission electron microscopy (TEM) grid post and facilitates more secure adhesion onto the grid post. We present evidence of autofluorescence in bacterially precipitated vaterite using this lamella preparation method coupled with TEM selected area diffraction. This innovative approach allows studying biomineralization at the micro to nano scales, which can provide novel insights into bacterial responses to microenvironmental conditions.

47 OTHER INSTRUMENTATION↗

A Comparison of Solidification Structures and Submicroscale Cellular Segregation in Rapidly Solidified Stainless Steels Produced via Two-Piston Splat Quenching and Laser Powder Bed Fusion

Fusion-based additive manufacturing techniques leverage rapid solidification (RS) conditions to create parts with complex geometries, unique microscale/nanoscale morphological features, and elemental segregation. Three custom composition stainless steel alloys with varying chromium equivalence to nickel equivalence ratio (Cr eq /Ni eq ) between 1.53 and 1.95 were processed using laser powder bed fusion (LPBF) and/or two-piston splat quenching (SQ) to produce solidification rates estimated between 0.4 and 0.8 m/s. Both scanning electron microscopy (SEM) and transmission electron microscopy (TEM) were utilized to collect high-resolution images, electron backscatter diffraction (EBSD) phase identification, and measure cellular segregation. Similar features were observed in both LPBF and SQ samples including phase and microstructure, nanoscale oxide particles, cell size, and segregation behavior. However, dislocation pileup was observed along the cell boundaries only in the LPBF austenite solidified microstructure. Targeted adjustment of the SQ feedstock Cr and Ni concentrations, within the ASTM A240 specification for 316L resulted in no observable impact on the cell size, oxide particle size, or magnitude of segregation. Also, the amount of Ni segregation in the ferrite solidified microstructures did not significantly differ, regardless of Cr/Ni eq or processing technique. Here, SQ is demonstrated as capable of simulating RS rates and microstructures similar to LPBF for use as an alternative screening tool for new RS alloy compositions.

42 ENGINEERING↗

In-Situ Transmission Electron Microscopy Study of the Evolution of Extended Defects in Oxide Nuclear Fuels

In-situ transmission electron microscopy (TEM) with simulated extreme environments is an effective tool for understanding and tracking microstructural changes down to the atomic scale. The objective of this research is to study the effect of temperature on the evolution of extended defects in ThO2 and UO2. Here, we present in-situ TEM isochronal thermal annealing experiments using a micro-electro-mechanical-system (MEMS)-based heating holder. ThO2 and UO2 single crystal specimens were grown inside an inert silver ampoule using hydrothermal synthesis. Both samples were irradiated using 2 MeV protons at 600oC up to 0.1 dpa at Texas A&M University’s Accelerator Laboratory. Fig. 1a shows a weak-beam dark field TEM image of ThO2 after irradiation, indicating the presence of faulted 1/3 <111> type dislocation loops. This presentation will discuss the effect of annealing temperature (600oC, 800oC, 1000oC, 1100oC, etc.) on dislocation loop density, size and distribution, loop nature (interstitial/vacancies) and Burgers vector, as well as the formation of voids in both ThO2 and UO2. This work will also discuss the interaction between defects during annealing. The in-situ TEM annealing cycle is shown in Fig 1b. This research significantly improves the understanding of defect behavior in oxide nuclear fuels with temperature and will aid computational modeling efforts. This work was supported as part of the Center for Thermal Energy Transport under Irradiation (TETI) Energy Frontier Research Center, funded by the U.S. Department of Energy Office of Science.

36 MATERIALS SCIENCE↗

Three-Dimensional Ultrastructure of Arabidopsis Cotyledons Infected with Colletotrichum higginsianum

We used serial block-face scanning electron microscopy (SBF-SEM) to study the host–pathogen interface between Arabidopsis cotyledons and the hemibiotrophic fungus Colletotrichum higginsianum. By combining high-pressure freezing and freeze-substitution with SBF-SEM, followed by segmentation and reconstruction of the imaging volume using the freely accessible software IMOD, we created 3D models of the series of cytological events that occur during the Colletotrichum–Arabidopsis susceptible interaction. We found that the host cell membranes underwent massive expansion to accommodate the rapidly growing intracellular hypha. As the fungal infection proceeded from the biotrophic to the necrotrophic stage, the host cell membranes went through increasing levels of disintegration culminating in host cell death. Intriguingly, we documented autophagosomes in proximity to biotrophic hyphae using transmission electron microscopy (TEM) and a concurrent increase in autophagic flux between early to mid/late biotrophic phase of the infection process. Occasionally, we observed osmiophilic bodies in the vicinity of biotrophic hyphae using TEM only and near necrotrophic hyphae under both TEM and SBF-SEM. Overall, we established a method for obtaining serial SBF-SEM images, each with a lateral ( x-y) pixel resolution of 10 nm and an axial ( z) resolution of 40 nm, that can be reconstructed into interactive 3D models using the IMOD. Application of this method to the Colletotrichum–Arabidopsis pathosystem allowed us to more fully understand the spatial arrangement and morphological architecture of the fungal hyphae after they penetrate epidermal cells of Arabidopsis cotyledons and the cytological changes the host cell undergoes as the infection progresses toward necrotrophy. [Formula: see text] Copyright © 2024 The Author(s). This is an open access article distributed under the CC BY 4.0 International license .

Biochemistry & Molecular Biology↗

Characterization of Microwave Loss Using Multimode Superconducting Resonators

Measuring the losses arising from different materials and interfaces is crucial to improving the coherence of superconducting quantum circuits. Although this has been of interest for a long time, current studies can either only provide bounds to those losses, or require several devices for a complete characterization. In this work, we introduce a method to measure the microwave losses of materials and interfaces with a single multi-mode superconducting resonator. We demonstrate a formalism for analyzing the loss sensitivity of multi-mode systems and discuss the design strategies of multi-mode resonators for material loss studies. We present two types of multi-mode superconducting resonators for the study of bulk superconductors: the forky whispering-gallery-mode resonator (FWGMR) and the ellipsoidal cavity. We use these resonators to measure the surface dielectric, conductor, and seam losses of high-purity (5N5) aluminum and aluminum alloy (6061), as well as how they are affected by chemical etching, diamond turning, and thin-film coating. Here, we find that chemical etching and diamond turning reduce both the surface dielectric and conductive losses of high-purity aluminum, but provide no appreciable improvement to the seam. Coating the surfaces of diamond-turned aluminum alloys with e-beam evaporated or sputtered aluminum thinfilms significantly reduces all three losses under study. In addition, we study the effect of chemical etching on the surface of high-purity aluminum using transmission electron microscopy (TEM) and find that the chemical etching process creates a thinner and more uniform oxide layer, consistent with the observed improvement in the surface dielectric loss.

25 ENERGY STORAGE↗

Deformation behavior of crystalline/amorphous Al-Si nanocomposites with nanolaminate or nanofibrous microstructures

Deformation mechanisms in sputter-deposited crystalline Al/amorphous Si nanocomposites with nanolaminate or nanofibrous morphology are characterized by nanoindentation, micropillar compression testing and transmission electron microscopy (TEM). The nanofibrous composite having crystalline Al nanofibers with ~40–50 nm in length and 15–20 nm in diameter embedded in amorphous Si exhibits strain hardening to a maximum flow stress of 2.9 GPa and no shear band (SB) formation in compression up to plastic strain exceeding 24%. On the other hand, nanolaminate composite that is composed of 80 nm crystalline Al layers and 20 nm amorphous Si layers exhibits catastrophic SBs starting at plastic strains in the range of 5–10%. Cross-sectional TEM of the deformed samples reveals a high density of stacking faults and twin boundaries in Al nanofibers and no microshear bands in the nanofibrous composite, suggesting plastic deformation in amorphous Si phase and crystalline Al nanofibers. Further, molecular dynamics simulations revealed that the plastic deformation in amorphous Si phase in the cosputtered films could be favored by the decrease in flow strength of amorphous Si with increasing Al solute concentration trapped in Si.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stress-induced structural changes in superconducting Nb thin films

Here we report on the analysis of stress-induced structural changes and the formation of an omega (ω) phase in polycrystalline Nb thin films deposited on Si by high-power impulse magnetron sputtering (HiPIMS) for superconducting qubits using x-ray diffraction (XRD), transmission electron microscopy (TEM), and density-functional theory (DFT). XRD analysis indicates that internal stresses in the Nb thin films lead to the formation of {112}$\langle$111$\rangle$ deformation twins and TEM analysis shows that ω phases nucleate at some of the twin boundaries in the Nb thin films. The size of ω phases ranges from 10 to 100 nm, which is comparable to the coherence length of Nb (≈40 nm), and ≈1% volume fraction of Nb grains exhibit this ω phase. The details of the formation mechanism and superconducting properties of the ω phases are investigated by DFT and potential roles of the ω phase in Nb as a source of decoherence in superconducting qubits are also discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Competing magnetic phases in Cr 3+𝛿 ⁢Te 4 are spatially segregated

Cr 1+𝑥⁢ Te 2 is a self-intercalated van der Waals system that is of current interest for its room-temperature room-temperature ferromagnetic (FM) phases and tunable topological properties. In bulk samples, the strain from the interstitial Cr ions leads to distinct structural phases for different ranges of 𝑥. Early neutron powder diffraction (NPD) measurements on the monoclinic phase Cr 3 ⁢Te 4 (𝑥=0.5) presented evidence for competing FM and antiferromagnetic (AFM) phases. Here we apply neutron diffraction to a single crystal of Cr 3+𝛿 ⁢Te 4 with 𝛿=−0.10 and discover that it consists of two distinct monoclinic phases, one with FM order below 𝑇 C ≈321 K and another that develops AFM order below 𝑇 N ≈86 K. In contrast, we find that a crystal with 𝛿=−0.26 exhibits only FM order below 𝑇 C ≈285 K. The single-crystal analysis is complemented by results obtained with NPD, x-ray powder diffraction, and transmission electron microscopy (TEM) measurements on the 𝛿=−0.10 composition. From observations of spontaneous magnetostriction of opposite sign at 𝑇 C and 𝑇 N , along with the TEM evidence for both monoclinic phases in a single thin ( ≈100 nm) grain, we conclude that the two phases must have a fine-grained ( ≲100 nm) intergrowth character, as might occur from high-temperature spinodal decomposition during the growth process. Calculations of the relaxed lattice structures for the FM and AFM phases with density functional theory provide a rationalization of the observed spontaneous magnetostrictions. Correlations between the magnitude and orientation of the magnetic moments with lattice parameter variation demonstrate that the magnetic orders are sensitive to strain, thus explaining why magnetic ordering temperatures and anisotropies can be different between bulk and thin-film samples, when the latter are subject to epitaxial strain. Our results point to the need to investigate the supposed coexistence FM and AFM phases reported elsewhere in the Cr 1+𝑥 ⁢Te 2 system, such as in the Cr 5 ⁢Te 8 phase (𝑥=0.25).

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Local and long-range atomic/magnetic structure of non-stoichiometric spinel iron oxide nanocrystallites

Spinel iron oxide nanoparticles of different mean sizes in the range 10–25 nm have been prepared by surfactant-free up-scalable near- and super-critical hydrothermal synthesis pathways and characterized using a wide range of advanced structural characterization methods to provide a highly detailed structural description. The atomic structure is examined by combined Rietveld analysis of synchrotron powder X-ray diffraction (PXRD) data and time-of-flight neutron powder-diffraction (NPD) data. The local atomic ordering is further analysed by pair distribution function (PDF) analysis of both X-ray and neutron total-scattering data. It is observed that a non-stoichiometric structural model based on a tetragonal γ-Fe 2 O 3 phase with vacancy ordering in the structure (space group P 4 3 2 1 2) yields the best fit to the PXRD and total-scattering data. Detailed peak-profile analysis reveals a shorter coherence length for the superstructure, which may be attributed to the vacancy-ordered domains being smaller than the size of the crystallites and/or the presence of anti-phase boundaries, faulting or other disorder effects. The intermediate stoichiometry between that of γ-Fe 2 O 3 and Fe 3 O 4 is confirmed by refinement of the Fe/O stoichiometry in the scattering data and quantitative analysis of Mössbauer spectra. The structural characterization is complemented by nano/micro-structural analysis using transmission electron microscopy (TEM), elemental mapping using scanning TEM, energy-dispersive X-ray spectroscopy and the measurement of macroscopic magnetic properties using vibrating sample magnetometry. Notably, no evidence is found of a Fe 3 O 4 /γ-Fe 2 O 3 core-shell nanostructure being present, which had previously been suggested for non-stoichiometric spinel iron oxide nanoparticles. Finally, the study is concluded using the magnetic PDF (mPDF) method to model the neutron total-scattering data and determine the local magnetic ordering and magnetic domain sizes in the iron oxide nanoparticles. The mPDF data analysis reveals ferrimagnetic collinear ordering of the spins in the structure and the magnetic domain sizes to be ∼60–70% of the total nanoparticle sizes. The present study is the first in which mPDF analysis has been applied to magnetic nanoparticles, establishing a successful precedent for future studies of magnetic nanoparticles using this technique.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Towards time-resolved MicroED grid preparation using mix-and-inject gas dynamic virtual nozzles

Recent progress in gas dynamic virtual nozzle (GDVN) technologies in combination with high-brilliance synchrotron and X-ray free-electron lasers (XFELs) has allowed the visualization of protein dynamics in crystallo by mixing macromolecular protein crystals with a substrate using tunable mixing times on the order of milliseconds to seconds prior to serial X-ray diffraction data collection. This has become the method of choice for high-resolution structure determination of intermediate states. However, such experiments require large counts of crystals of proper sizes for high-resolution data collection, and premium beam times for screening efforts. Cryogenic microcrystal electron diffraction (MicroED) represents a complementary technique that may be a more accessible avenue for time-resolved nanocrystallography compared with serial X-ray diffraction experiments. MicroED can produce full diffraction datasets from just a few submicrometre-thick crystals, and the approach is more readily accessible, requiring standard cryogenic transmission electron microscopy (TEM) equipment available at many universities and institutes. Cryogenic MicroED, like other forms of cryo-EM, begins with rapidly freezing biological material on electron microscopy grids. In the case of MicroED, micro- to nano-crystals (<500 nm thick) are deposited onto electron microscopy grids and plunge-frozen for subsequent electron diffraction data collection. Here, we have incorporated GDVN technology developed originally for XFEL experiments into the freezing process as a first step towards time-resolved studies. We describe the limited deposition efficiency of the model MicroED protein proteinase K on TEM grids using GDVNs, preceding sample vitrification and successful MicroED data collection. We discuss both the initial results from such experiments and the methodological challenges in developing this approach into a reliable workflow for millisecond-to-second time-resolved structural studies of macromolecules. Our results promise a strategy to deposit crystals on grids using GDVNs and determine high-resolution structures by MicroED, constituting a first step towards development of time-resolved MicroED experiments.

MicroED↗

In Situ Transmission Electron Microscopy: Signal processing challenges and examples

Transmission electron microscopy (TEM) is a powerful tool for imaging material structure and characterizing material chemistry. Recent advances in data collection technology for TEM have enabled high-volume and high-resolution data collection at a microsecond frame rate. Here, taking advantage of these advances in data collection rates requires the development and application of data processing tools, including image analysis, feature extraction, and streaming data processing techniques. In this article, we highlight a few areas in materials science that have benefited from combining signal processing and statistical analysis with data collection capabilities in TEM and present a future outlook on opportunities of integrating signal processing with automated TEM data analysis.

36 MATERIALS SCIENCE↗

Effects of microstructure on the oxidation behavior of A3 matrix‐grade graphite

Abstract The oxidation behavior of matrix‐grade graphite in air‐ or steam‐ingress accident scenarios is of great interest for high‐temperature gas reactors (HTGRs). In this study, the microstructures of two variants of matrix‐grade graphite based on the German A3‐3 and A3‐27 formulations were characterized with scanning electron microscopy (SEM), transmission electron microscopy (TEM), and Raman spectroscopy, and correlated to oxidation behavior observed through thermogravimetric analysis (TGA) and differential scanning calorimetry (DSC). Through TEM imaging and selected area electron diffraction (SAED), a higher volume fraction of partially graphitized carbon was identified in the A3‐3 type graphite than in the A3‐27 type. This structure is believed to have contributed to the accelerated oxidation exhibited by A3‐3 in the chemical reaction‐controlled oxidation regime.

Bratten, Adam↗