Search NASA⌕ Search

SEARCH · Search NASA

Results for “VAPORIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Advanced Detector and Waveform Digitizer for Water Vapor DIAL Systems

Measurement of atmospheric water vapor has become a major requirement for understanding moist-air processes. Differential absorption lidar (DIAL) is a technique best suited for the measurement of atmospheric water vapor. NASA Langley Research Center is continually developing improved DIAL systems. One aspect of current development is focused on the enhancement of a DIAL receiver by applying state-of-the-art technology in building a new compact detection system that will be placed directly on the DIAL receiver telescope. The newly developed detection system has the capability of being digitally interfaced with a simple personal computer, using a discrete input/output interface. This has the potential of transmitting digital data over relatively long distances instead of analog signals, which greatly reduces measurement noise. In this paper, we discuss some results from the new compact water vapor DIAL detection system which includes a silicon based avalanche photodiode (APD) detector, a 14-bit, 10-MHz waveform digitizer, a microcontroller and other auxiliary electronics. All of which are contained on a small printed-circuit-board. This will significantly reduce the weight and volume over the current CAMAC system and eventually will be used in a water vapor DIAL system on an unpiloted atmospheric vehicle (UAV) aircraft, or alternatively on an orbiting spacecraft.

Refaat, Tamer F.↗

Bulk Growth of Wide Band Gap II-VI Compound Semiconductors by Physical Vapor Transport

The mechanism of physical vapor transport of II-VI semiconducting compounds was studied both theoretically, using a one-dimensional diffusion model, as well as experimentally. It was found that the vapor phase stoichiometry is critical in determining the vapor transport rate. The experimental heat treatment methods to control the vapor composition over the starting materials were investigated and the effectiveness of the heat treatments was confirmed by partial pressure measurements using an optical absorption technique. The effect of residual (foreign) gas on the transport rate was also studies theoretically by the diffusion model and confirmed experimentally by the measurements of total pressure and compositions of the residual gas. An in-situ dynamic technique for the transport rate measurements and a further extension of the technique that simultaneously measured the partial pressures and transport rates were performed and, for the first time, the experimentally determined mass fluxes were compared with those calculated, without any adjustable parameters, from the diffusion model. Using the information obtained from the experimental transport rate measurements as guideline high quality bulk crystal of wide band gap II-VI semiconductor were grown from the source materials which undergone the same heat treatment methods. The grown crystals were then extensively characterized with emphasis on the analysis of the crystalline structural defects.

Su, Ching-Hua↗

Kinetic Requirements for the Measurement of Mesospheric Water Vapor at 6.8 (microns) under Non-LTE Conditions

We present accuracy requirements for specific kinetic parameters used to calculate the populations and vibrational temperatures of the H2O(010) and H2O(020) states in the terrestrial mesosphere. The requirements are based on rigorous simulations of the retrieval of mesospheric water vapor profiles from measurements of water vapor infrared emission made by limb scanning instruments on orbiting satellites. Major improvements in the rate constants that describe vibration-to- vibration exchange between the H2O(010) and 02(1) states are required in addition to improved specification of the rate of quenching Of O2(1) by atomic oxygen (0). It is also necessary to more accurately determine the yield of vibrationally excited O2(l) resulting from ozone photolysis. A contemporary measurement of the rate of quenching of H2O(010) by N2 and O2 is also desirable. These rates are either highly uncertain or have never before been measured at atmospheric temperatures. The suggested improvements are necessary for the interpretation of water vapor emission measurements at 6.8 microns to be made from a new spaceflight experiment in less than 2 years. The approach to retrieving water vapor under non-LTE conditions is also presented.

Zhou, Daniel K.↗

Numerical Modeling of Physical Vapor Transport in Contactless Crystal Growth Geometry

Growth from the vapor under conditions of limited contact with the walls of the growth ampoule is beneficial for the quality of the growing crystal due to reduced stress and contamination which may be caused by interactions with the growth container. The technique may be of a particular interest for studies on crystal growth under microgravity conditions: elimination of some factors affecting the crystal quality may make interpretation of space-conducted processes more conclusive and meaningful. For that reason, and as a part of our continuing studies on 'contactless' growth technique, we have developed a computational model of crystal growth process in such system. The theoretical model was built, and simulations were performed using the commercial computational fluid dynamics code, (CFD) ACE. The code uses an implicit finite volume formulation with a gray discrete ordinate method radiation model which accounts for the diffuse absorption and reflection of radiation throughout the furnace. The three-dimensional model computes the heat transfer through the crystal, quartz, and gas both inside and outside the ampoule, and mass transport from the source to the crystal and the sink. The heat transport mechanisms by conduction, natural convection, and radiation, and mass transport by diffusion and convection are modeled simultaneously and include the heat of the phase transition at the solid-vapor interfaces. As the thermal boundary condition, temperature profile along the walls of the furnace is used. For different thermal profiles and furnace and ampoule dimensions, the crystal growth rate and development of the crystal-vapor and source-vapor interfaces (change of the interface shape and location with time) are obtained. Super/under-saturation in the ampoule is determined and critical factors determining the 'contactless' growth conditions are identified and discussed. The relative importance of the ampoule dimensions and geometry, the furnace dimensions and its temperature, and the properties of the grown material are analyzed. The results of the simulations are compared with related experimental results on growth of CdTe, CdZnTe, ZnTe, PbTe, and PbSnTe crystals by this technique.

Palosz, W.↗

Crystal Growth of ZnSe by Physical Vapor Transport: A Modeling Study

Crystal growth from the vapor phase has various advantages over melt growth. The main advantage is from a lower processing temperature which makes the process more amenable in instances where the melting temperature of the crystal is high. Other benefits stem from the inherent purification mechanism in the process due to differences in the vapor pressures of the native elements and impurities, and the enhanced interfacial morphological stability during the growth process. Further, the implementation of Physical Vapor Transport (PVT) growth in closed ampoules affords experimental simplicity with minimal needs for complex process control which makes it an ideal candidate for space investigations in systems where gravity tends to have undesirable effects on the growth process. Bulk growth of wide band gap II-VI semiconductors by physical vapor transport has been developed and refined over the past several years at NASA MSFC. Results from a modeling study of PVT crystal growth of ZnSe arc reported in this paper. The PVI process is numerically investigated using both two-dimensional and fully three-dimensional formulation of the governing equations and associated boundary conditions. Both the incompressible Boussinesq approximation and the compressible model are tested to determine the influence of gravity on the process and to discern the differences between the two approaches. The influence of a residual gas is included in the models. The preliminary results show that both the incompressible and compressible approximations provide comparable results and the presence of a residual gas tends to measurably reduce the mass flux in the system. Detailed flow, thermal and concentration profiles will be provided in the final manuscript along with computed heat and mass transfer rates. Comparisons with the 1-D model will also be provided.

Ramachandran, Narayanan↗

Performance Modeling of an Airborne Raman Water Vapor Lidar

A sophisticated Raman lidar numerical model had been developed. The model has been used to simulate the performance of two ground-based Raman water vapor lidar systems. After tuning the model using these ground-based measurements, the model is used to simulate the water vapor measurement capability of an airborne Raman lidar under both day-and night-time conditions for a wide range of water vapor conditions. The results indicate that, under many circumstances, the daytime measurements possess comparable resolution to an existing airborne differential absorption water vapor lidar while the nighttime measurement have higher resolution. In addition, a Raman lidar is capable of measurements not possible using a differential absorption system.

Whiteman, D. N.↗

MIR Measurements of Atmospheric Water Vapor Profiles

Three subjects related to atmospheric water vapor profiling using the 183.3 GHz absorption line are discussed in this paper. First, data acquired by an airborne millimeter-wave imaging radiometer (MIR) over ocean surface in the western Pacific are used to estimate three-dimensional (3-D) distribution of atmospheric water vapor. The instrument's radiometric measurements with mixed vertical and horizontal polarizations require modifications to the retrieval algorithm used in the past. It is demonstrated that, after the modifications, the new algorithm can provide adequate retrieval of water vapor profiles, even though the measured data are of mixed polarizations. Next, the retrieved profiles, in terms of water vapor mixing ratio rho (g/kg), are compared with those measured in near concurrence by dropsondes from a research aircraft in the western Pacific and by a ground-based Raman lidar at Wallops Island, Virginia. The ratio of the standard deviation to the mean rho is found to be 0.12 at 0.25 km altitude and gradually degraded to 0.67 at the highest altitude of the retrieval of 10.25 km. Finally, the effect of the "initial guess" relative humidity profile on the final retrieved product is analyzed with respect to the condition for the convergent retrieval. It is found that the effect is minimal if the initial profile is not unrealistically different from the true one. If the initial profile is very different from the true one, the final retrieved product could be subject to a substantial error. Tightening of the convergent condition in the retrieval helped reduce magnitude of the error, but not remove it totally. It is concluded that an initial profile based on climatology is likely to provide most reliable retrieval results.

Wang, J. R.↗

Water Vapor Feedbacks to Climate Change

The response of water vapor to climate change is investigated through a series of model studies with varying latitudinal temperature gradients, mean temperatures, and ultimately, actual climate change configurations. Questions to be addressed include: what role does varying convection have in water vapor feedback; do Hadley Circulation differences result in differences in water vapor in the upper troposphere; and, does increased eddy energy result in greater eddy vertical transport of water vapor in varying climate regimes?

Rind, David↗

Evaluation of Terms in the Water Vapor Budget Using Airborne Dial and In Situ Measurements from the Southern Great Plans 1997 Experiment

The Southern Great Plains (SGP97) field experiment was conducted in Oklahoma during June and July 1997 primarily to validate soil moisture retrieval algorithms using microwave radiometer measurements from aircraft as well as in situ surface measurements. One important objective of the SGP97 experiment plan was to examine the effect of soil moisture on the evolution of the atmospheric boundary layer (ABL) and clouds over the Southern Great Plains during the warm season. To support boundary layer studies during SGP97. the NASA Langley Research Center's Lidar Atmospheric Sensing Experiment (LASE) was flown on a NASA-P3 aircraft in conjunction with the Electronically Scanned Thinned Array Radiometer (ESTAR). The LASE instrument is an airborne, downward-looking differential absorption lidar (DIAL) system capable of measuring water vapor concentration as well as aerosol backscatter with high horizontal and vertical resolution in the ABL. Here, we will demonstrate how the LASE data can be used to determine water vapor statistics and most of the water vapor budget terms in the ABL. This information can then be related to spatial variations in soil moisture and the surface energy budget. The extensive surface and aircraft in situ measurements conducted during SGP97 provide information on the ABL that cannot be retrieved from the LASE data alone and also offer an excellent opportunity to validate the remote water vapor budget measurements with LASE.

Senff, Christoph J.↗

Retrieval Assimilation and Modeling of Atmospheric Water Vapor from Ground- and Space-Based GPS Networks: Investigation of the Global and Regional Hydrological Cycles

Uncertainty over the response of the atmospheric hydrological cycle (particularly the distribution of water vapor and cloudiness) to anthropogenic forcing is a primary source of doubt in current estimates of global climate sensitivity, which raises severe difficulties in evaluating its likely societal impact. Fortunately, a variety of advanced techniques and sensors are beginning to shed new light on the atmospheric hydrological cycle. One of the most promising makes use of the sensitivity of the Global Positioning System (GPS) to the thermodynamic state, and in particular the water vapor content, of the atmosphere through which the radio signals propagate. Our strategy to derive the maximum benefit for hydrological studies from the rapidly increasing GPS data stream will proceed in three stages: (1) systematically analyze and archive quality-controlled retrievals using state-of-the-art techniques; (2) employ both currently available and innovative assimilation procedures to incorporate these determinations into advanced regional and global atmospheric models and assess their effects; and (3) apply the results to investigate selected scientific issues of relevance to regional and global hydrological studies. An archive of GPS-based estimation of total zenith delay (TZD) data and water vapor where applicable has been established with expanded automated quality control. The accuracy of the GPS estimates is being monitored; the investigation of systematic errors is ongoing using comparisons with water vapor radiometers. Meteorological packages have been implemented. The accuracy and utilization of the TZD estimates has been improved by implementing a troposphere gradient model. GPS-based gradients have been validated as real atmospheric moisture gradients, establishing a link between the estimated gradients and the passage of weather fronts. We have developed a generalized ray tracing inversion scheme that can be used to analyze occultation data acquired from space- or land-based receivers. The National Center for Atmospheric Research mesoscale model (version MM5) has been adapted for Southern California, and assimilation studies are underway. Additional information is contained in the original.

Dickey, Jean O.↗

Growth of Carbon Nanostructure Materials Using Laser Vaporization

Since the potential applications of carbon nanotubes (CNT) was discovered in many fields, such as non-structure electronics, lightweight composite structure, and drug delivery, CNT has been grown by many techniques in which high yield single wall CNT has been produced by physical processes including arc vaporization and laser vaporization. In this presentation, the growth mechanism of the carbon nanostructure materials by laser vaporization is to be discussed. Carbon nanoparticles and nanotubes have been synthesized using pulsed laser vaporization on Si substrates in various temperatures and pressures. Two kinds of targets were used to grow the nanostructure materials. One was a pure graphite target and the other one contained Ni and Co catalysts. The growth temperatures were 600-1000 C and the pressures varied from several torr to 500 torr. Carbon nanoparticles were observed when a graphite target was used, although catalysts were deposited on substrates before growing carbon films. When the target contains catalysts, carbon nanotubes (CNT) are obtained. The CNT were characterized by scanning electron microscopy, x-ray diffraction, optical absorption and transmission, and Raman spectroscopy. The temperature-and pressure-dependencies of carbon nanotubes' growth rate and size were investigated.

Zhu, Shen↗

Characterization of Advanced Avalanche Photodiodes for Water Vapor Lidar Receivers

Development of advanced differential absorption lidar (DIAL) receivers is very important to increase the accuracy of atmospheric water vapor measurements. A major component of such receivers is the optical detector. In the near-infrared wavelength range avalanche photodiodes (APD's) are the best choice for higher signal-to-noise ratio, where there are many water vapor absorption lines. In this study, characterization experiments were performed to evaluate a group of silicon-based APD's. The APD's have different structures representative of different manufacturers. The experiments include setups to calibrate these devices, as well as characterization of the effects of voltage bias and temperature on the responsivity, surface scans, noise measurements, and frequency response measurements. For each experiment, the setup, procedure, data analysis, and results are given and discussed. This research was done to choose a suitable APD detector for the development of an advanced atmospheric water vapor differential absorption lidar detection system operating either at 720, 820, or 940 nm. The results point out the benefits of using the super low ionization ratio (SLIK) structure APD for its lower noise-equivalent power, which was found to be on the order of 2 to 4 fW/Hz(sup (1/2)), with an appropriate optical system and electronics. The water vapor detection systems signal-to-noise ratio will increase by a factor of 10.

Refaat, Tamer F.↗

Comparison of Columnar Water Vapor Measurements During The Fall 1997 ARM Intensive Observation Period: Optical Methods

In the fall of 1997 the Atmospheric Radiation Measurement (ARM program conducted an intensive Observation Period (IOP) to study water vapor at its Southern Great Plains (SGP) site. Among the large number of instruments, four sun-tracking radiometers were present to measure the columnar water vapor (CWV). All four solar radiometers retrieve CWV by measuring solar transmittance in the 0.94-micrometer water vapor absorption band. As one of the steps in the CWV retrievals the aerosol component is subtracted from the total transmittance, in the 0.94-micrometer band. The aerosol optical depth comparisons among the same four radiometers are presented elsewhere. We have used three different methods to retrieve CWV. Without attempting to standardize on the same radiative transfer model and its underlying water vapor spectroscopy we found the CWV to agree within 0.13 cm (rms) for CWV values ranging from 1 to 5 cm. Preliminary results obtained when using the same updated radiative transfer model with updated spectroscopy for all instruments will also be shown. Comparisons to the microwave radiometer results will be included in the comparisons.

Schmid, Beat↗

Development and Validation of Water Vapor Tracers as Diagnostics for the Atmospheric Hydrologic Cycle

Understanding of the local and remote sources of water vapor can be a valuable diagnostic in understanding the regional atmospheric hydrologic cycle. In the present study, we have implemented passive tracers as prognostic variables to follow water vapor evaporated in predetermined regions until the water tracer precipitates. The formulation of the sources and sinks of tracer water is generally proportional to the prognostic water vapor variable. Because all water has been accounted for in tracers, the water vapor variable provides the validation of the tracer water and the formulation of the sources and sinks. The tracers have been implemented in a GEOS General Circulation Model (GCM) simulation consisting of several summer periods to determine the source regions of precipitation for the United States and India. The recycling of water and interannual variability of the sources of water will be examined. Potential uses in GCM sensitivity studies, predictability studies and data assimilation will be discussed.

Bosilovich, Michael G.↗

Visualization of Atmospheric Water Vapor Data for SAGE

The goal of this project was to develop visualization tools to study the water vapor dynamics using the Stratospheric Aerosol and Gas Experiment 11 (SAGE 11) water vapor data. During the past years, we completed the development of a visualization tool called EZSAGE, and various Gridded Water Vapor plots, tools deployed on the web to provide users with new insight into the water vapor dynamics. Results and experiences from this project, including papers, tutorials and reviews were published on the main Web page. Additional publishing effort has been initiated to package EZSAGE software for CD production and distribution. There have been some major personnel changes since Fall, 1998. Dr. Mou-Liang Kung, a Professor of Computer Science assumed the PI position vacated by Dr. Waldo Rodriguez who was on leave. However, former PI, Dr. Rodriguez continued to serve as a research adviser to this project to assure smooth transition and project completion. Typically in each semester, five student research assistants were hired and trained. Weekly group meetings were held to discuss problems, progress, new research direction, and activity planning. Other small group meetings were also held regularly for different objectives of this project. All student research assistants were required to submit reports for conference submission.

Kung, Mou-Liang↗

Vapor Growth of Binary and Ternary Chalcogenides in Preparation for Microgravity Experiments

In the bulk crystal growth of some technologically important semiconducting chalcopyrites, such as ZnTe, CdS, ZnSe and ZnS, vapor growth techniques have significant advantages over melt growth techniques due to the high melting points of these materials. The realization of routine production of high-quality single crystals of these semiconductors requires a fundamental, systematic and in-depth study on the PVT growth process and crystal growth by vapor transport in low gravity offers a set of unique conditions for this study. Previously, two reasons have been put forward to account for this. The first is weight-related reductions in crystal strain and defects. These are thought to be caused by the weight of the crystals during processing at elevated temperatures and retained on cooling, particularly for materials with a low yield strength. The second, and more general, reason is related to the reduction in density-gradient driven convection. The PVT crystal growth process consists of essentially three processes: sublimation of the source material, transport of the vapor species and condensation of the vapor species to form the crystal. The latter two processes can be affected by the convection caused by gravitational accelerations on Earth. Reductions in such convection in low gravity is expected to yield a nearly diffusion-limited growth condition which results in more uniform growth rates (on the microscopic scale) and hence greater crystalline perfection and compositional homogeneity. The reduction of convective contamination by performing flight experiments in a reduced gravity environment will help to understand the relation between fluid phase processes (growth parameters) and defect and impurity incorporation in grown crystals.

Su, C.↗

Crystal Growth of ZnSe and Related Ternary Compound Semiconductors by Vapor Transport

Crystal growth by vapor transport has several distinct advantages over melt growth techniques. Among various potential benefits from material processing in reduced gravity the followings two are considered to be related to crystal growth by vapor transport: (1) elimination of the crystal weight and its influence on the defect formation and (2) reduction of natural buoyancy-driven convective flows arising from thermally and/ or solutally induced density gradient in fluids. The previous results on vapor crystal growth of semiconductors showed the improvements in surface morphology, crystalline quality, electrical properties and dopant distribution of the crystals grown in reduced gravity as compared to the crystals grown on Earth. But the mechanisms, which are responsible for the improvements and cause the gravitational effects on the complicated and coupled processes of vapor mass transport and growth kinetics, are not well understood.

Su, Ching-Hua↗

Comparison of Columnar Water Vapor Measurements During The Fall 1997 ARM Intensive Observation Period: Solar Transmittance Methods

In the fall of 1997, during an Intensive Observation Period (IOP), the Atmospheric Radiation Measurement (ARM) program conducted a study of water vapor abundance measurement at its Southern Great Plains (SGP) site. Among a large number of instruments, four sun-tracking radiometers were present to measure the columnar water vapor (CWV). All four solar radiometers retrieve CWV by measuring total solar transmittance in the 0.94-gm water vapor absorption band and subtracting contributions due to Rayleigh, ozone and aerosol transmittances. The aerosol optical depth comparisons among the same four radiometers has been presented elsewhere (Geophys. Res. Lett., 26, 17, 2725-2728, 1999). We have used three different methods to retrieve CWV. In a first round of comparison no attempt was made to standardize on the same radiative transfer model and its underlying water vapor spectroscopy. In the second round of comparison we used the same line-by-line code (which includes recently corrected H2O spectroscopy) to retrieve CAN from all four suntracking radiometers. This decreased the mean CWV by 8% or 13%. The spread of 8% in the solar radiometer results found when using the same model is an indication of the other-than-model uncertainties involved in determining CWV from solar transmittance measurements with current instrumentation.

Schmid, B.↗