Search NASA⌕ Search

SEARCH · Search NASA

Results for “VELOCITY MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Velocity surface measurements for ZnO films over /001/-cut GaAs

A potential application for a piezoelectic film deposited on a GaAs substrate is the monolithic integration of surface acoustic wave (SAW) devices with GaAs electronics. Knowledge of the SAW properties of the filmed structure is critical for the optimum design of such devices. In this article, the measurements of the velocity surface, which directly affects the SAW diffraction, on the bare and metallized ZnO/SiO2 or Si3N4/GaAs /001/-cut samples are reported using two different techniques: (1) knife-edge laser probe, (2) line-focus-beam scanning acoustic microscope. Comparisons, such as measurement accuracy and tradeoffs, between the former (dry) and the latter (wet) method are given. It is found that near the group of zone axes (110) propagation direction the autocollimating SAW property of the bare GaAs changes into a noncollimating one for the layered structure, but a reversed phenomenon exists near the group of zone axes (100) direction. The passivation layer of SiO2 or Si3N4 (less than 0.2 micrometer thick) and the metallization layer change the relative velocity but do not significantly affect the velocity surface. On the other hand, the passivation layer reduces the propagation loss by 0.5-1.3 dB/microseconds at 240 MHz depending upon the ZnO film thickness. Our SAW propagation measurements agree well with theorectical calculations. We have also obtained the anisotropy factors for samples with ZnO films of 1.6, 2.8, and 4.0 micrometer thickness. Comparisons concerning the piezoelectric coupling and acoustic loss between dc triode and rf magnetron sputtered ZnO films are provided.

Kim, Yoonkee↗

Development of a laser-Doppler system for measurement of velocity fields in PVT crystal growth systems

A laser-Doppler velocimetry (LDV) system capable of measuring velocities as low as 10 exp -5 m/s is presented, and a calibration system for determining the accuracy of the LDV system at these velocities is described. The results obtained in mercurous chloride crystal grown in cylindrical ampoules at 300 C, using physical vapor transport (PVT) methods, are presented. It is concluded that the overall flow pattern observed is a unicellular, asymmetric pattern between Rayleigh number of 125 and 250.

Jones, O. C.↗

Spatially and Temporally Resolved Measurements of Velocity in a H2-air Combustion-Heated Supersonic Jet

This paper presents simultaneous measurements at multiple points of two orthogonal components of flow velocity using a single-shot interferometric Rayleigh scattering (IRS) technique. The measurements are performed on a large-scale Mach 1.6 (Mach 5.5 enthalpy) H2-air combustion jet during the 2007 test campaign in the Direct Connect Supersonic Combustion Test facility at NASA Langley Research Center. The measurements are performed simultaneously with CARS (Coherent Anti-stokes Raman Spectroscopy) using a combined CARS-IRS instrument with a common path 9-nanosecond pulsed, injection-seeded, 532-nm Nd:YAG laser probe pulse. The paper summarizes the measurements of velocities along the core of the vitiated air flow as well as two radial profiles. The average velocity measurement near the centerline at the closest point from the nozzle exit compares favorably with the CFD calculations using the VULCAN code. Further downstream, the measured axial velocity shows overall higher values than predicted with a trend of convergence at further distances. Larger discrepancies are shown in the radial profiles.

Bivolaru, Daniel↗

A device for measuring sonic velocity and compressor Mach number

A device has been developed which measures the velocity of sound in fluids at stagnation and is especially adaptable to turbine and compressor testing for which the constituency of the working fluid may be in doubt. By utilizing the shaft frequency of a rotary compressor, the instrument can also be used to provide a direct measurement of the compressor Mach number (ratio of blade-tip velocity to inlet velocity of sound at stagnation). A Helmholtz resonator is employed in the measurement of the sound velocity. Viscous effects in the orifice of the Helmholtz resonator are shown to be important and can be taken into account with the help of a parameter obtained from Stokes solution of the flow near an oscillating wall. This parameter includes the kinematic viscosity of the fluid and the frequency of sound in the resonator. When these effects are recognized, the resonator can be calibrated to measure velocity of sound or compressor Mach number to an accuracy of better than 0.5 percent.

Huber, Paul W↗

Nitric oxide molecular tagging velocimetry of a free-flight model in a reflected shock tunnel

Nitric oxide molecular tagging velocimetry (NO MTV) is used to characterize the wake behind a free-flight spherical model in the test section of a free-piston reflected shock tunnel using a burst-mode laser operated at 100 kHz. A novel (to our knowledge) multi-delay timing scheme was implemented to measure velocity in a varying collisional environment in the wake of the free-flight model. Four simultaneous velocity profiles were measured in the wake of the model from -600 to 3600 m/s for flow enthalpies of 10.3 and 12.0 MJ/kg. Finally, the measured velocity distributions show good agreement when compared to computational fluid dynamics (CFD) modeling.

47 OTHER INSTRUMENTATION↗

Vibration-Free Raman Doppler Velocimeter

New method under development to measure flow velocity of molecules directly by nonintrusive laser techniques. This method, combined with vibration-free design, makes flow-velocity measurements practical in severe vibrational environments. Raman scattering and retroreflection combine to yield useful technique for wind-tunnel gas-flow mapping. Nonintrusive measurements of gas velocity, temperature, and pressure possible in highly vibrational environment.

Exton, R. J.↗

Two-frequency laser-induced fluorescence technique for rapid velocity-field measurements in gas flows

A technique is presented for measurements of two-dimensional velocity fields in gas flows. The single-mode frequency of an argon-ion laser is fixed in the wing of an absorption line of iodine molecules that are seeded at low level in the flow of interest. The emitted fluorescence is detected with an image-intensified 100 x 100 photodiode-array camera. two pairs of counterpropagating laser sheets sequentially probe the flow to determine two velocity components. The frequency in one pair is shifted with respect to the other by an acousto-optic modulator. This two-frequency scheme eliminates the need to determine the slope of the line externally and offers the potential for combined pressure and velocity-field measurements.

Hiller, B.↗

The delta Doppler technique for LDV measurements at long distances

A technique for measuring velocity, referred to as a Delta Doppler technique, was presented. This technique determines scattering source velocities by measuring the difference in Doppler shifts of two different frequencies. By transmitting the two frequencies along the same path, a moving fringe pattern is established such that a nonmoving scatterer at the sensing volume would see an intensity variation exactly equal to the difference in the transmitted frequencies. If the particle has a velocity component along an axis which bisects the angle formed by the transmitter and receiver axes, a Doppler shift in the difference frequency can be measured and the velocity component computed. The frequency measured would correspond to the difference in Doppler frequencies that two laser Doppler velocimeters using separate frequencies (the same frequencies as used previously) would have measured, thus the term Delta Doppler.

Cliff, W. C.↗

Quantitative Velocity Field Measurements in Reduced-Gravity Combustion Science and Fluid Physics Experiments

Systems have been developed and demonstrated for performing quantitative velocity measurements in reduced gravity combustion science and fluid physics investigations. The unique constraints and operational environments inherent to reduced-gravity experimental facilities pose special challenges to the development of hardware and software systems. Both point and planar velocimetric capabilities are described, with particular attention being given to the development of systems to support the International Space Station laboratory. Emphasis has been placed on optical methods, primarily arising from the sensitivity of the phenomena of interest to intrusive probes. Limitations on available power, volume, data storage, and attendant expertise have motivated the use of solid-state sources and detectors, as well as efficient analysis capabilities emphasizing interactive data display and parameter control.

Greenberg, Paul S.↗

Multiple Velocity Profile Measurements in Hypersonic Flows using Sequentially-Imaged Fluorescence Tagging

Nitric-oxide planar laser-induced fluorescence (NO PLIF) was used to perform velocity measurements in hypersonic flows by generating multiple tagged lines which fluoresce as they convect downstream. For each laser pulse, a single interline, progressive scan intensified CCD camera was used to obtain separate images of the initial undelayed and delayed NO molecules that had been tagged by the laser. The CCD configuration allowed for sub-microsecond acquisition of both images, resulting in sub-microsecond temporal resolution as well as sub-mm spatial resolution (0.5-mm x 0.7-mm). Determination of axial velocity was made by application of a cross-correlation analysis of the horizontal shift of individual tagged lines. Quantification of systematic errors, the contribution of gating/exposure duration errors, and influence of collision rate on fluorescence to temporal uncertainty were made. Quantification of the spatial uncertainty depended upon the analysis technique and signal-to-noise of the acquired profiles. This investigation focused on two hypersonic flow experiments: (1) a reaction control system (RCS) jet on an Orion Crew Exploration Vehicle (CEV) wind tunnel model and (2) a 10-degree half-angle wedge containing a 2-mm tall, 4-mm wide cylindrical boundary layer trip. The experiments were performed at the NASA Langley Research Center's 31-inch Mach 10 wind tunnel.

Bathel, Brett F.↗

On-axis velocity component measurement with laser velocimeters

The application of Doppler shifted laser light to the measurement of the two velocity components normal to the optical axis of the system is relatively simple as compared to the measurement of the on-axis velocity component. The present paper deals with the reference-beam (local oscillator) technique and the dual-beam (fringe mode) technique, which have been developed for measuring the on-axis component. Some results obtained for the on-axis component are examined.

Neti, S.↗

Rayleigh Scattering Diagnostic for Dynamic Measurement of Velocity Fluctuations in High Speed Jets

A flow diagnostic technique based on the molecular Rayleigh scattering of laser light is used to obtain dynamic density and velocity data in a high speed flow. The technique is based on analyzing the Rayleigh scattered light with a Fabry-Perot interferometer used in the static, imaging mode. An analysis is presented that established a lower bound for measurement uncertainty of about 20 m/sec for individual velocity measurements obtained in a 100 microsecond time interval. Software and hardware interfaces were developed to allow computer control of all aspects of the experiment and data acquisition. The signals from three photomultiplier tubes were simultaneously recorded using photon counting at a 10 kHz sampling rate and 10 second recording periods. Density and velocity data, including distribution functions and power spectra, taken in a Mach 0.8 free jet, are presented.

Seasholtz, Richard G.↗

Demonstration of the shock-timing technique for ignition targets on the National Ignition Facility

A high-performance inertial confinement fusion capsule is compressed by multiple shock waves before it implodes. To minimize the entropy acquired by the fuel, the strength and timing of those shock waves must be accurately controlled. Ignition experiments at the National Ignition Facility (NIF) will employ surrogate targets designed to mimic ignition targets while making it possible to measure the shock velocities inside the capsule. A series of experiments on the OMEGA laser facility [Boehly et al., Opt. Commun. 133, 495 (1997)] validated those targets and the diagnostic techniques proposed. Quartz was selected for the diagnostic window and shock-velocity measurements were demonstrated in Hohlraum targets heated to 180 eV. Cryogenic experiments using targets filled with liquid deuterium further demonstrated the entire timing technique in a Hohlraum environment. Direct-drive cryogenic targets with multiple spherical shocks were used to further validate this technique, including convergence effects at relevant pressures (velocities) and sizes. These results provide confidence that shock velocity and timing can be measured in NIF ignition targets, allowing these critical parameters to be optimized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatially and Temporally Resolved Velocimetry for Hypersonic Flows

The development of new hypersonic flight vehicles is limited by the physical understanding that may be obtained from ground test facilities. This has motivated the present development of a temporally and spatially resolved velocimetry measurement for Sandia National Laboratories (SNL) Hypersonic Wind Tunnel (HWT) using Femtosecond Laser Electronic Excitation Tagging (FLEET). First, a multi-line FLEET technique has been created for the first time and tested in a supersonic jet, allowing simultaneous measurements of velocities along multiple profiles in a flow. Secondly, two different approaches have been demonstrated for generating dotted FLEET lines. One employs a slit mask pattern focused into points to yield a dotted line, allowing for two- or three-component velocity measurements free of contamination between components. The other dotted-line approach is based upon an optical wedge array and yields a grid of points rather than a dotted line. Two successful FLEET measurement campaigns have been conducted in SNL’s HWT. The first effort established optimal diagnostic configurations in the hypersonic environment based on earlier benchtop reproductions, including validation of the use of a 267 nm beam to boost the measurement signal-to-noise ratio (SNR) with minimal risk of perturbing the flow and greater simplicity than a comparable resonant technique at 202 nm. The same FLEET system subsequently was reconstituted to demonstrate the ability to make velocimetry measurements of hypersonic turbulence in a realistic flow field. Mean velocity profiles and turbulence intensity profiles of the shear layer in the wake of a hypersonic cone model were measured at several different downstream stations, proving the viability of FLEET as a hypersonic diagnostic.

33 ADVANCED PROPULSION SYSTEMS↗

Supersonic Mass Flux Measurements via Tunable Diode Laser Absorption and Non-Uniform Flow Modeling

Measurements of mass flux are obtained in a vitiated supersonic ground test facility using a sensor based on line-of-sight (LOS) diode laser absorption of water vapor. Mass flux is determined from the product of measured velocity and density. The relative Doppler shift of an absorption transition for beams directed upstream and downstream in the flow is used to measure velocity. Temperature is determined from the ratio of absorption signals of two transitions (lambda(sub 1)=1349 nm and lambda(sub 2)=1341.5 nm) and is coupled with a facility pressure measurement to obtain density. The sensor exploits wavelength-modulation spectroscopy with second-harmonic detection (WMS-2f) for large signal-to-noise ratios and normalization with the 1f signal for rejection of non-absorption related transmission fluctuations. The sensor line-of-sight is translated both vertically and horizontally across the test section for spatially-resolved measurements. Time-resolved measurements of mass flux are used to assess the stability of flow conditions produced by the facility. Measurements of mass flux are within 1.5% of the value obtained using a facility predictive code. The distortion of the WMS lineshape caused by boundary layers along the laser line-of-sight is examined and the subsequent effect on the measured velocity is discussed. A method for correcting measured velocities for flow non-uniformities is introduced and application of this correction brings measured velocities within 4 m/s of the predicted value in a 1630 m/s flow.

Chang, Leyen S.↗

Particle-Image Velocimetry in Microgravity Laminar Jet Diffusion Flames

This paper discusses planned velocity measurements in microgravity laminar jet diffusion flames. These measurements will be conducted using Particle-Image Velocimetry (PIV) in the NASA Glenn 2.2-second drop tower. The observations are of fundamental interest and may ultimately lead to improved efficiency and decreased emissions from practical combustors. The velocity measurements will support the evaluation of analytical and numerical combustion models. There is strong motivation for the proposed microgravity flame configuration. Laminar jet flames are fundamental to combustion and their study has contributed to myriad advances in combustion science, including the development of theoretical, computational and diagnostic combustion tools. Nonbuoyant laminar jet flames are pertinent to the turbulent flames of more practical interest via the laminar flamelet concept. The influence of gravity on these flames is deleterious: it complicates theoretical and numerical modeling, introduces hydrodynamic instabilities, decreases length scales and spatial resolution, and limits the variability of residence time. Whereas many normal-gravity laminar jet diffusion flames have been thoroughly examined (including measurements of velocities, temperatures, compositions, sooting behavior and emissive and absorptive properties), measurements in microgravity gas-jet flames have been less complete and, notably, have included only cursory velocity measurements. It is envisioned that our velocity measurements will fill an important gap in the understanding of nonbuoyant laminar jet flames.

Sunderland, P. B.↗

Data compression of measurements of peculiar velocities of supernovae type Ia

We study the compression of information present in the correlated perturbations to the luminosity distance in the low-redshift (z<0.1) supernovae Ia due to peculiar velocities of these supernovae. We demonstrate that the naieve compression into angular velocity power spectrum does not work efficiently, due to thickness of the spherical shell over which the supernovae are measured. Instead, we show that measurements can be compressed into measurements of f{sup 2}P(k), where f is the logarithmic rate of growth of linear perturbations and P(k) is their power spectrum. We develop an optimal quadratic estimator and show that it recovers all information for {Lambda}CDM models for surveys of N{approx}10,000 or more supernovae. We explicitly demonstrate robustness with respect to the assumed fiducial model and the number of power spectrum bins. Using mock catalogues of supernovae Ia we estimate that future low-redshift surveys will be able to probe {sigma}{sub 8} to 6% accuracy with 10 000 supernovae Ia.

79 ASTRONOMY AND ASTROPHYSICS↗