Search NASA⌕ Search

SEARCH · Search NASA

Results for “VIBRATION MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Effects of experimentally measured pressure oscillations on the vibration of a solid rocket motor

Results are presented of firing a Nike rocket against a backstop for the purpose of obtaining pressure fluctuations in the rocket case and determining their relationship to structural vibrations of the case. Special care was required to obtain these pressure fluctuations because of the much higher static pressure generated in the rocket. Very small pressure fluctuations within the rocket case can cause significant vibration levels. A previously observed high frequency was shown to decrease with time before completely disappearing at about 1 second of burning time. The vibration of the case itself is probably related to the longitudinal structural modes at frequencies below 500 Hz and is dependent on local structural conditions at frequencies above this value.

Schoenster, J. A.↗

Microwave spectrum of cis-glyoxal.

The rotational spectrum of glyoxal has been investigated in the region from 18.0 to 40.0 GHz. Only B-type transitions were observed. Both Q-branch and R-branch assignments have been made for the ground state, and the Q-branch assignment has been made for the first excited state of the internal rotational mode. From relative intensity measurements of vibrational excited states, the torsional vibration is found to have a frequency of 114 plus or minus 8 per cm. From a consideration of the rotational constants, it is concluded that the isomer giving rise to the microwave spectrum is the planar cis form and not the gauche isomer. The dipole moment was determined to be 4.8 plus or minus 0.2 D.

Durig, J. R.↗

Experimental evaluation of multiplane-multispeed rotor balancing through multiple critical speeds

The experimentally proven range of application of the influence-coefficient balancing method, especially the least-squares procedure, is extended to include the case of multiple bending critical speeds within the operating range of a test rotor. Tests were conducted on a laboratory quality machine capable of speeds up to 18,000 rpm in order to investigate several distinct practical aspects of flexible-rotor balancing. These include: (1) balancing for operation through four bending critical speeds, (2) balancing of rotors mounted in both rigid and flexible bearing supports, (3) balancing of rotors with various amounts of measured vibration-response data and different numbers of correction planes, and (4) balancing of rotors with different arbitrary initial-unbalance configurations. The results show that a lightly damped, flexible rotor can be balanced systematically and efficiently through four bending critical speeds. It is concluded that the influence-coefficient method should be equally applicable to rotors or shafts having more than four bending critical speeds in their operating-speed ranges.

Tessarzik, J. M.↗

Excursion of vibrating microelectrodes in tissue

The paper deals with a vibrating microelectrode holder consisting of a support rod attached to the cone of a miniature loudspeaker. This holder facilitates a microelectrode penetration into arterial wall tissue, eliminates surface dimpling, and relieves polarographic artifacts believed to be due to tissue compression. The paper presents construction and performance details of the electrode holder, and evaluates the extent of possible damage incurred during such vibration by measuring electrode motion relative to surrounding tissue in an excised segment of femoral artery in the rabbit. It is concluded that under proper vibratory conditions microelectrodes can be easily inserted into the arterial wall with minimum tissue disturbance.

Kanabus, E. W.↗

Testing of UH-60A helicopter transmission in NASA Lewis 2240-kW (3000-hp) facility

The U.S. Army's UH-60A Black Hawk 2240-kW (3000-hp) class, twin-engine helicopter transmission was tested at the NASA Lewis Research Center. The vibration and efficiency test results will be used to enhance the data base for similar-class helicopters. Most of the data were obtained for a matrix of test conditions of 50 to 100 percent of rated rotor speed and 20 to 100 percent of rated input power. The transmission's mechanical efficiency at 100 percent of rated power was 97.3 and 97.5 percent with its inlet oil maintained at 355 and 372 K (180 and 210 F), respectively. The highest vibration reading was 72 g's rms at the upper housing side wall. Other vibration levels measured near the gear meshes are reported.

Mitchell, A. M.↗

N2O vibration-rotation parameters derived from measurements in the 900-1090- and 1580-2380/cm regions

Fourier-transform spectrometric measurements of the N2O IR spectrum in the 900-1090 and 1580-2380/cm regions were obtained at a 0.005/cm resolution, and line frequencies of eight species for several ground state bands and hot bands are analyzed to obtain values of band centers and upper-state effective rotational constants. Several bands are reported for the first time. Least-squares fits for the 0400-0000, 0420(e)-0000, and 0510-0110 bands of the (N-14)2O-16 species suggest perturbation of the high-J levels of the upper states. Resonance interactions were noted in transitions including the 1001-1000 bands of (N-14)2O-16 and N-15N-14O-16.

Toth, Robert A.↗

The analysis of nonstationary vibration data

The general methodology for the analysis of arbitrary nonstationary random data is reviewed. A specific parametric model, called the product model, that has applications to space vehicle launch vibration data analysis is discussed. Illustrations are given using the nonstationary launch vibration data measured on the Space Shuttle orbiter vehicle.

Piersol, Allan G.↗

Flight Motor Set 360L003 (STS-29R)

The redesigned solid rocket motor (RSRM) flight set 360L003 was launched on March 13, 1989 as part of NASA space shuttle mission STS-29R. As was the case with flight sets 360L001 and 360L002 (STS-26R and STS-27R), both motors (360L003A and 360L003B) performed in an excellent manner. Evaluation of the ground environment instrumentation measurements verified thermal model analysis data and showed agreement with predicted environmental effects. The right-hand aft field joint primary heater failed during the countdown; the secondary heater was activated and performed as designed. All other field joint heaters and aft skirt thermal conditioning systems had no anomalies. Shuttle thermal imager infrared readings compared favorably with measured ground environment instrumentation data. No thermal launch commit criteria violations occurred at any time. Evaluation of the development flight instrumentation showed exceptional propulsion performance. All ballistic parameters closely matched the predicted values and were well within the required specification levels. Girth and biaxial strain gage measurements compared closely with corresponding gages on previous flight motors, static tests, and with preflight predictions. Adequate safety factors were verified. (Some ignition transient spiking was noted in a few girth gages; the spiking was determined not to be representative of actual case behavior, but an instrumentation phenomena.) The accelerometers again measured high vibration amplitude levels during the ignition transient and the reentry Max Q phases. Postflight inspection showed that all combustion gas was contained by the insulation in the field and case-to-nozzle joints. No anomalous insulation erosion patterns were found, and the seals that did directly contain motor pressure showed no heat effects, erosion, or blowby. All anomalies identified were a result of splashdown damage, with the exception of fretting in the case field joint interference (nonsealing) surfaces and a prelaunch field joint heater failure. The disposition of all anomalies and the complete results are reported.

Riehr, Glen A.↗

Effect of heat treatment on stiffness and damping of Sic/Ti-15-3

The effect of heat treatment on material properties of Sic/Ti-15-3 was measured by vibration tests. Heat treatment changes the microstructure, which stiffens the matrix and reduces its damping capacity. Test results illustrate how the changes in matrix material affect the stiffness and damping properties of the composite. Damping was found to be more sensitive than stiffness to microstructural changes in the matrix. Effects of heat treatment temperature and exposure time are presented.

Grady, Joseph E.↗

Electron beam fluorescence measurements in the Boeing hypersonic shock tunnel

The Calspan electron beam fluorescence (EBF) measurement system is described along with the results of measurements made in hypersonic flow. Numerous self-emitting metallic species were identified, many of which may be associated with an aging/erosion process within the B30HST. Because there were only 16 tunnel runs, it was only possible to obtain spectral measurements over a limited range of wavelengths and time sampling periods. Many spectral features of the flow remain uninvestigated. Because flow self-emission is important to all optical diagnostic techniques, it is recommended that additional spectral studies by performed. The three electron beam-excited species that were identified are nitrogen, helium, and nitric oxide. The high metallic radiation background interfered with attempts to obtain the time-wise variation of N2 density and He radiation with the optical fiber/PMT channels. In the case of the N2 density measurements the result of interference was increased uncertainty. Unfortunately, the interference caused the time-wise He measurements to fail completely. It is recommended that the electron beam be modulated to provide discrimination against the background radiation in future N2 density measurements. Careful data reduction produced useful measurements of N2 vibrational temperature, even though the high background from metallic species significantly increased measurement uncertainty. Perhaps the recommended additional spectral studies would reveal N2(+) First Negative System band-pair regions having less background. Detection of the He arrival was easily accomplished with the spectrometer/array detector system. Because of this, it is recommended that this means of detecting He arrival be used in the future. With proper calibrations of the system an He number density could be obtained. Although the flow conditions were out of limits for the run in which the NO spectrum was recorded, the usefulness of the NO spectrum for determination of free-stream rotational temperature was demonstrated and should be exploited in future experiments. Indeed, based on the strong NO signals, it is recommended that lower resolution NO spectra be obtained to provide a measure of NO vibrational temperature in the same manner that the N2 temperature was obtained.

Price, Linwood L.↗

Gravity referenced elevation encoder development

Recent progress in the development of a gravity-sensor-based instrument for determining the elevation angle of DSN antennas is described. The benefits of such a system include the capability to locate the Gravity Referenced Elevation Encoder (GREE) directly on the primary reflector (thus bypassing structural flexure and deformation error sources), anticipated lower maintenance costs compared to the present gimbal encoders, direct replaceability, or supplementation of the present gimbal encoders and the utilization of off-the-shelf components to construct the GREE. This article includes a description of the nominal GREE design. Test results on a laboratory breadboard model are given. Rigid-body dynamics of the GREE are derived and the simulated performance in response to measured antenna vibrations is given.

Goddard, R. E.↗

Research activity at the shock tube facility at NASA Ames

The general design and operating conditions of NASA Ames's electric arc drive shock tube facility are described, and the measurements conducted at the facility to support the development of a theoretical model of the effects of chemical nonequilibrium over a hypersonic vehicle are summarized. In particular, attention is given to the results of measurements at a shock velocity of 6.20 km/s in 1 Torr nitrogen and measurements at a shock velocity of 10.2 km/s in 0.1 Torr air. The discussion covers reaction rate measurement, the use of holographic interferometry, and measurements of vibrational populations using Raman scattering.

Sharma, Surendra P.↗

The Application of High-temperature Strain Gauges to the Measurements of Vibratory Stresses in Gas-turbine Buckets

The feasibility of measuring the vibration in the buckets of a gas turbine under service conditions of speed and temperature was determined by use of a high temperature wire strain gauge cemented to a modified supercharger turbine bucket. A high-temperature wire strain gauge and the auxiliary mechanical and electrical equipment developed for the investigation are described.

Kemp, R H↗

Effect of Interstage Bleed on Rotating Stall and Blade Vibration in a 13-stage Axial-flow Compressor in a Turbojet Engine

The compressor case of a 13-stage axial-flow compressor was modified to incorporate air-bleed systems over the fifth and tenth rotor stages. Rotating stall-exited rotor-blade vibrations were measured in the first and second stages at 60 and 68 percent of rated speed, respectively. Either the fifth- or the tenth-stage bleeds satisfactorily eliminated the peak vibratory stresses.

Calvert, Howard F↗

Noncontact Electromagnetic Vibration Source

Metal aircraft skins scanned rapidly in vibration tests. Relatively simple combination of permanent magnets and electromagnet serves as noncontact vibration source for nondestructive testing of metal aircraft skins. In test, source excites vibrations, and vibration waveforms measured, then analyzed for changes in resonances signifying cracks and other flaws.

Namkung, Min↗

Dual-Element Tunneling Accelerometer

Improved micromachined tunneling accelerometer contains two deflecting transducer elements: One an elastically supported proof mass having relatively low resonant frequency; other cantilever tunneling transducer that tracks displacement of proof mass and has relatively high resonant frequency ({sup a} 10 kHz). Deflection voltage generated by circuit like described in "Wideband Feedback Circuit for Tunneling Sensor" (NPO-18866). Accelerometers of this type suited for underwater acoustic measurements, detecting vibrations associated with malfunctions in vehicles, detecting seismic signals, monitoring and controlling vibrations in structures, and other applications.

Kaiser, William J.↗