Response control for fatigue testing of non-linear systems
A signal conditioner which ensures that peak and low values during vibration testing are not lost during nonlinear or asymmetric vibration testing on small structures is described. The trapped signals may be for acceleration, velocity, or displacement. The test signal is sent through an analog circuit to a multiplexer, which resets to zero each time a zero-line is crossed by another incoming signal. Peak positive and negative amplitude and frequency are retained and nonsymmetric responses are thus detected, rather than averaged out.