Search NASA⌕ Search

SEARCH · Search NASA

Results for “Vibration Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Rattlesnake Vibration Controller v.2.0

SAND2021-7300 O The Rattlesnake Vibration Controller is a combined-environments, multiple input/multiple output control system for dynamic excitation of structures under test. It provides capabilities to control multiple responses on the part using multiple exciters and control strategies. Rattlesnake is written in the Python programming language to facilitate multiple input/multiple output vibration research by allowing users to prescribe custom control laws to the controller. Rattlesnake can target multiple hardware devices, or even perform synthetic control to simulate a test virtually. Rattlesnake has been used to execute control problems with up to 200 response channels and 12 drives. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Rohe, Daniel↗

Quench conditioning device. Vibrational quench conditioning

Recently a new type of device, capacitor-based, aiming to eliminate or reduce superconducting magnet training was developed and tested at FNAL. I’ll review its main characteristics and principles of operation, make relevant comparisons and conclusions. Separately, I’ll discuss somewhat similar concepts based on induced vibrations in magnets, but I’ll extend this topic to cover both training reduction and quench protection. Those will be discussed at conceptual level, arguing about feasibility of such an approach and the need for more focused research on the topic, including simulations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Welding for testability: An approach aimed at improving the ultrasonic testing of thick-walled austenitic and dissimilar metal welds

Austenitic and dissimilar welds in thick walled components show a coarse grained, dendritic microstructure. Therefore, ultrasonic testing has to deal with beam refraction, scattering and mode conversion effects. As a result, the testing techniques typically applied for isotropic materials yield dissatisfying results. Most approaches for improvement of ultrasonic testing have been based on modeling and improved knowledge of the complex wave propagation phenomena. In this paper, we discuss an alternative approach: is it possible to use a modified welding technology which eliminates the cause of the UT complications, i.e. the large-grained structure of the weld seams? Various modification parameters were tested, including: TIG current pulsing, additional DC and AC magnetic fields, and also additional external vibrations during welding. For all welds produced under different conditions, the grain structure of the weld seam was characterized by optical and GIUM microstructure visualizations on cross sections, wave field propagation measurements, and ultrasonic tests of correct detectability of flaws. The mechanical properties of the welds were also tested.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Efficient anharmonic vibrational spectroscopy for large molecules using local-mode coordinates

This article presents a general computational approach for efficient simulations of anharmonic vibrational spectra in chemical systems. An automated local-mode vibrational approach is presented, which borrows techniques from localized molecular orbitals in electronic structure theory. This approach generates spatially localized vibrational modes, in contrast to the delocalization exhibited by canonical normal modes. The method is rigorously tested across a series of chemical systems, ranging from small molecules to large water clusters and a protonated dipeptide. It is interfaced with exact, grid-based approaches, as well as vibrational self-consistent field methods. Most significantly, this new set of reference coordinates exhibits a well-behaved spatial decay of mode couplings, which allows for a systematic, a priori truncation of mode couplings and increased computational efficiency. Convergence can typically be reached by including modes within only about 4 Å. The local nature of this truncation suggests particular promise for the ab initio simulation of anharmonic vibrational motion in large systems, where connection to experimental spectra is currently most challenging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ab initio wavenumber accurate spectroscopy : {sup 1}CH{sub 2} and HCN vibrational levels on automatically generated IMLS potential energy surfaces.

We report here calculated J = 0 vibrational frequencies for {sup 1}CH{sub 2} and HCN with root-mean-square error relative to available measurements of 2.0 cm{sup -1} and 3.2 cm{sup -1}, respectively. These results are obtained with DVR calculations with a dense grid on ab initio potential energy surfaces (PESs). The ab initio electronic structure calculations employed are Davidson-corrected MRCI calculations with double-, triple-, and quadruple-{zeta} basis sets extrapolated to the complete basis set (CBS) limit. In the {sup 1}CH{sub 2} case, Full CI tests of the Davidson correction at small basis set levels lead to a scaling of the correction with the bend angle that can be profitably applied at the CBS limit. Core-valence corrections are added derived from CCSD(T) calculations with and without frozen cores. Relativistic and non-Born-Oppenheimer corrections are available for HCN and were applied. CBS limit CCSD(T) and CASPT2 calculations with the same basis sets were also tried for HCN. The CCSD(T) results are noticeably less accurate than the MRCI results while the CASPT2 results are much poorer. The PESs were generated automatically using the local interpolative moving least-squares method (L-IMLS). A general triatomic code is described where the L-IMLS method is interfaced with several common electronic structure packages. All PESs were computed with this code running in parallel on eight processors. The L-IMLS method provides global and local fitting error measures important in automatically growing the PES from initial ab initio seed points. The reliability of this approach was tested for {sup 1}CH{sub 2} by comparing DVR-calculated vibrational levels on an L-IMLS ab initio surface with levels generated by an explicit ab initio calculation at each DVR grid point. For all levels ({approx}200) below 20000 cm{sup -1}, the mean unsigned difference between the levels of these two calculations was 0.1 cm{sup -1}, consistent with the L-IMLS estimated mean unsigned fitting error of 0.3 cm{sup -1}. All L-IMLS PESs used in this work have comparable mean unsigned fitting errors, implying that fitting errors have a negligible role in the final errors of the computed vibrational levels with experiment. Less than 500 ab initio calculations of the energy and gradients are required to achieve this level of accuracy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

CALiPER Report 20.3: Robustness of LED PAR38 Lamps

Three samples of 40 of the Series 20 PAR38 lamps underwent multi-stress testing, whereby samples were subjected to increasing levels of simultaneous thermal, humidity, electrical, and vibrational stress. The results do not explicitly predict expected lifetime or reliability, but they can be compared with one another, as well as with benchmark conventional products, to assess the relative robustness of the product designs. On average, the 32 LED lamp models tested were substantially more robust than the conventional benchmark lamps. As with other performance attributes, however, there was great variability in the robustness and design maturity of the LED lamps. Several LED lamp samples failed within the first one or two levels of the ten-level stress plan, while all three samples of some lamp models completed all ten levels. One potential area of improvement is design maturity, given that more than 25% of the lamp models demonstrated a difference in failure level for the three samples that was greater than or equal to the maximum for the benchmarks. At the same time, the fact that nearly 75% of the lamp models exhibited better design maturity than the benchmarks is noteworthy, given the relative stage of development for the technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bridge Testing With Ground-Based Interferometric Radar: Experimental Results

The research of innovative non-contact techniques aimed at the vibration measurement of civil engineering structures (also for damage detection and structural health monitoring) is continuously directed to the optimization of measures and methods. Ground-Based Radar Interferometry (GBRI) represents the more recent technique available for static and dynamic control of structures and ground movements.Dynamic testing of bridges and buildings in operational conditions are currently performed: (a) to assess the conformity of the structure to the project design at the end of construction; (b) to identify the modal parameters (i.e. natural frequencies, mode shapes and damping ratios) and to check the variation of any modal parameters over the years; (c) to evaluate the amplitude of the structural response to special load conditions (i.e. strong winds, earthquakes, heavy railway or roadway loads). If such tests are carried out by using a non-contact technique (like GBRI), the classical issues of contact sensors (like accelerometers) are easily overtaken.This paper presents and discusses the results of various tests carried out on full-scale bridges by using a Stepped Frequency-Continuous Wave radar system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Designing the Neutron Detector for the NEXUS Test Facility

The SuperCDMS dark matter experiment is commissioning a new test facility at Fermilab, NEXUS, capable of testing a new suite of detectors that promise to push to lower dark matter masses than has previously been achieved. These detectors use silicon and germanium, cooled to tens of mK, to measure small vibrations in the crystal lattice caused by very tiny energy deposits. A core capability of NEXUS test facility is to use a commercial neutron generator, coupled to an array of detectors behind the test facility, to calibrate the nuclear recoil energy scale of these detectors through neutron scattering. The response of silicon and germanium to nuclear recoils below 1 keV energy transfer is largely unknown. For dark matter models which are primarily interacting with the nucleus, calibration of this response will completely determine the dark matter sensitivity of the experiment. In this context, the proper design of the neutron tagging detector to be used in the test facility needs to be found. This work will include simulation of the detector behavior and work towards an optimization of the detector geometry based on measurement resolution and detection rate. In addition, prototype scintillators and photodetectors will be studied as candidate detector elements.

47 OTHER INSTRUMENTATION↗

Development, Testing, and Validation of Fabry-Pérot Cavity Acoustic Sensors for Microreactor Applications

Nuclear microreactors are a unique reactor design which may allow for the nuclear energy industry to tap into unconventional markets, and their modularity presents some advantages over larger, conventional reactor designs. For nuclear microreactors to be economically viable, on-line structural health monitoring may be necessary to reduce operation and maintenance costs with lower power production. Optical fiber sensors, and specifically optical Fabry-Pérot cavities (FPCs), may present the opportunity to monitor vibrational frequencies of microreactor components during operation, enabling identification of the location and severity of potential damage. In this work, FPCs were designed and fabricated with materials which may be able to survive in the extremely harsh environment of nuclear microreactors. The FPCs were bonded to metal test specimens to monitor their vibrational frequencies, along with a reference piezoelectric accelerometer. Euler-Bernoulli theory was used to calculate the fundamental modes and mode-shapes to compare with experimentally measured frequency spectra. The peak frequencies detected with the FPC and piezoelectric accelerometer, and theoretical modes, all agreed well for the first four fundamental modes (within 5%). Furthermore, when the FPC and accelerometer were co-located on the test specimen, their peak frequencies all agreed within 1%.

Birri, Tony↗

Development and experimental evaluation of an acoustic flow meter prototype for measuring air flow

Here, this study outlines the development and testing of a flow meter prototype specifically designed for use in nuclear reactor environments. The meter uses flow-induced vibration to measure flow rates and is designed for remote monitoring in harsh environments where radiation can damage electronics. The device generates a vibration signal produced by a feedback system when fluid flows out of an orifice and interacts with a downstream wedge. The frequency of the vibration signal corresponds directly to flow rate and velocity. The study investigates geometric parameters intrinsic to the prototype, such as orifice height, width, edge distance, and chamber length. Different configurations were also tested, including a bypass loop with variable cross-sections around the device. The investigation results reveal the impact of these geometric parameters on the vibration signal output, providing valuable insights for future design improvements and enhancing the effectiveness of flow metering systems used in nuclear reactor applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Organic Enrichment at Aqueous Interfaces: Cooperative Adsorption of Glucuronic Acid to DPPC Monolayers Studied with Vibrational Sum Frequency Generation

Surface tension, surface-specific vibrational spectroscopy and differential scanning calorimetry measurements were all used to test cooperative adsorption of glucuronic acid (GU) to DPPC monolayers adsorbed to the aqueous/vapor interface. Experiments were performed using GU solutions prepared in Millipore water and in carbonate/bicarbonate solutions buffered to a pH of 9.0. The effects of GU on DPPC monolayer structure and organization were carried out with tightly packed monolayers (40 Å2/DPPC) and monolayers in their liquid condensed phase (55 Å2/molecule). Surface tension data show that GU concentrations of 50 mM lead to expanded DPPC monolayers with diminished surface tensions (or higher surface pressures) at a given DPPC coverage relative to monolayers on pure water. With unbuffered solutions, GU induces significant ordering within liquid condensed monolayers although the effects of GU on tightly packed DPPC monolayers are less pronounced. GU also induces a second, higher melting temperature in DPPC vesicles implying that GU (at sufficiently high concentrations) strengthens lipid-lipid cohesion, possibly by replacing water solvating the DPPC headgroups. Together, these observations all support a cooperative adsorption mechanism. In buffer solutions, the effects of dissolved GU on DPPC structure and organization are muted. Only at sufficiently high GU concentrations (when the solution’s buffering capacity has been exceeded) do the data again show evidence of cooperative adsorption. These findings place limits on cooperative adsorption’s ability to enrich interfacial organic content in alkaline environmental systems such as oceans.

Link, Katie A.↗

An all fiber-optic multi-parameter structure health monitoring system

In this article, we present an all fiber-optics based multi-parameter structure health monitoring system, which is able to monitor strain, temperature, crack and thickness of metal structures. This system is composed of two optical fibers, one for laser-acoustic excitation and the other for acoustic detection. A nano-second 1064 nm pulse laser was used for acoustic excitation and a 2 mm fiber Bragg grating was used to detect the acoustic vibration. The feasibility of this system was demonstrated on an aluminum test piece by the monitoring of the temperature, strain and thickness changes, as well as the appearance of an artificial crack. The multiplexing capability of this system was also preliminarily demonstrated.

36 MATERIALS SCIENCE↗

Quasi-static displacement calibration system for a “Violin-Mode” shadow-sensor intended for Gravitational Wave detector suspensions

This paper describes the design of, and results from, a calibration system for optical linear displacement (shadow) sensors. The shadow sensors were designed to detect “Violin-Mode” (VM) resonances in the 0.4 mm diameter silica fibre suspensions of the test masses/mirrors of Advanced Laser Interferometer Gravitational Wave Observatory gravitational wave interferometers. Each sensor illuminated the fibre under test, so as to cast its narrow shadow onto a “synthesized split photodiode” detector, the shadow falling over adjacent edges of the paired photodiodes. The apparatus described here translated a vertically orientated silica test fibre horizontally through a collimated Near InfraRed illuminating beam, whilst simultaneously capturing the separate DC “shadow notch” outputs from each of the paired split photodiode detectors. As the ratio of AC to DC photocurrent sensitivities to displacement was known, a calibration of the DC response to quasi-static shadow displacement allowed the required AC sensitivity to vibrational displacement to be found. Special techniques are described for generating the required constant scan rate for the test fibre using a DC motor-driven stage, for removing “jitter” at such low translation rates from a linear magnetic encoder, and so for capturing the two shadow-notch signals at each micrometre of the test fibre's travel. Calibration, across the four detectors of this work, gave a vibrational responsivity in voltage terms of (9.45 ± 1.20) MV (rms)/m, yielding a VM displacement sensitivity of (69 ± 13) pm (rms)/√Hz, at 500 Hz, over the required measuring span of ±0.1 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

LCLS-II CRYOMODULE TRANSPORT SYSTEM TESTING

The Cryomodules (CM) for the Linear Coherent Light Source II (LCLS-II) will be shipped to SLAC (Menlo Park, California) from JLab (Newport News, Virginia) and FNAL (Batavia, Illinois). A transportation system has been designed and built to safely transport the CMs over the road. It uses an array of helical isolator springs to attenuate shocks on the CM to below 1.5g in all directions. The system rides on trailers equipped with Air-Ride suspension, which attenuates vibration loads. The prototype LCLS-II CM (pCM) was driven 750 miles to test the transport system; shock loggers recorded the shock attenuation on the pCM and vacuum gauges were used to detect any compromises in beamline vacuum. Alignment measurements were taken before and after the trip to check whether cavity positions had shifted beyond the ± 0.2mm spec. Passband frequencies and cavity gradients were measured at 2K at the Cryomodule Test Facility (CMTF) at JLab to identify any degradation of CM performance after transportation. The transport system was found to have safely carried the CM and is cleared to begin shipments from JLab and FNAL to SLAC.

Huque, Naeem↗

Railcar Dynamics Model of the ENSA/DOE Multimodal Transportation Campaign Rail Conveyance System

Railcar dynamics models can be applied to calculate loads transmitted to used nuclear fuel (UNF) during normal conditions of transportation (NCT). This work details the development of a railcar dynamics model for the Equipos Nucleares of Spain-U.S. Department of Energy (ENSA/DOE) multimodal transportation campaign. The model was developed using NUCARS and represents the Kasgro 12-axle railcar and the ENSA ENUN-32P cask and cradle used during the campaign. The dynamics of the cask and cradle are captured by modeling them as a single degree-of-freedom (SDOF) system with optimized stiffness and damping parameters. The model was tuned using a statistical design method and manual parameter adjustment, and validated by comparing the predicted response to data collected from captive track tests. The SDOF cask and cradle model simplifies downstream analyses used to predict loads on UNF. Previous methods fed the railcar deck motion into computationally expensive finite element models of the cask and cradle; capturing the dynamics of the cask and cradle in the railcar model bypasses this step. The model provides information useful for understanding the shock and vibration environment of UNF during rail transportation, and the agreement achieved between model and test provides confidence that the methods used in this work could be used for other vehicle configurations such as the ATLAS railcar.

Kadooka, Kevin↗

TRIPWIRE – Deployment and Field-Testing Report

TRIPWIRE is a multi-modal system for containment verification in inaccessible radiological and nuclear waste repositories. The sensing modes are focused on radiation, electromagnetic and vibration. The radiation detection component has been developed over the last three years at Idaho National Laboratory (INL). This development has focused on the fabrication, characterization, and testing of long-length (greater than 10-m) plastic scintillating fibers. This fiscal year, the focus of TRIPWIRE has been on field testing and demonstration of the radiation sensing component in a relevant environment. After reviewing the static storage facilities at INL, the Radioactive Scrap Waste Facility (RSWF) south storage area outside the Materials and Fuels Complex (MFC) was selected due to its periodic changes in configuration and inventory. This report summarizes the research outcomes for the work performed in fiscal year (FY) 2023.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Vibrational spectroscopy of HNS degradation.

Hexanitrostilbene (HNS) is a widely used explosive, due in part to its high thermal stability. Degradation of HNS is known to occur through UV, chemical exposure, and heat exposure, which can lead to reduced performance of the material. Common methods of testing for HNS degradation include wet chemical and surface area testing of the material itself, and performance testing of devices that use HNS. The commonly used chemical tests, such as volatility, conductivity and contaminant trapping provide information on contaminants rather than the chemical stability of the HNS itself. Additionally, these tests are destructive in nature. As an alternative to these methods, we have been exploring the use of vibrational spectroscopy as a means of monitoring HNS degradation non-destructively. In particular, infrared (IR) spectroscopy lends itself well to non-destructive analysis. Molecular variations in the material can be identified and compared to pure samples. The utility of IR spectroscopy was evaluated using pressed pellets of HNS exposed to DETA (diethylaminetriamine). Amines are known to degrade HNS, with the proposed product being a {sigma}-adduct. We have followed these changes as a function of time using various IR sampling techniques including photoacoustic and attenuated total reflectance (ATR).

99 GENERAL AND MISCELLANEOUS↗