Search NASA⌕ Search

SEARCH · Search NASA

Results for “Virtualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Proof-of-principle demonstration of a virtual flow meter-based transducer for gaseous helium monitoring in particle accelerator cryogenics

A transducer based on a virtual flow meter is proposed for monitoring helium distribution and consumption in cryogenic systems for particle accelerators. The virtual flow meter allows technical and economical constraints, preventing installation of physical instruments in all the needed measurement points, to be overcome. Virtual flow meter performance for the alternative models of Samson [ http://www.samson.de (2015)] and Sereg-Schlumberger [ http://www.slb.com/ (2015)] is compared with the standard IEC 60534-2-1 [Industrial-process control valves—Part 2-1: Flow capacity—sizing equations for fluid flow under installed conditions (2011), https://webstore.iec.ch/publication/2461], for a large temperature range, for both gaseous and liquid helium phases, and for different pressure drops. Then, the calibration function of the transducer is derived. Finally, the experimental validation for the helium gaseous state on the test station for superconducting magnets in the laboratory SM18 [Pirotte et al., AIP Conf. Proc. 1573, 187 (2014)] at CERN is reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design of virtual SCADA simulation system for pressurized water reactor

The Virtual SCADA system is a software-based Human-Machine Interface that can visualize the process of a plant. This paper described the results of the virtual SCADA system design that aims to recognize the principle of the Nuclear Power Plant type Pressurized Water Reactor. This simulation uses technical data of the Nuclear Power Plant Unit Olkiluoto 3 in Finland. This device was developed using Wonderware Intouch, which is equipped with manual books for each component, animation links, alarm systems, real time and historical trending, and security system. The results showed that in general this device can demonstrate clearly the principles of energy flow and energy conversion processes in Pressurized Water Reactors. This virtual SCADA simulation system can be used as instructional media to recognize the principle of Pressurized Water Reactor.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

InGaP solar cell on Ge-on-Si virtual substrate for novel solar power conversion

InGaP single-junction solar cells are grown on lattice-matched Ge-on-Si virtual substrates using metal-organic chemical vapor deposition. Optoelectronic simulation results indicate that the optimal collection length for InGaP single-junction solar cells with a carrier lifetime range of 2–5 ns is wider than approximately 1 μ m. Electron beam-induced current measurements reveal that the threading dislocation density (TDD) of InGaP solar cells fabricated on Ge and Ge-on-Si substrates is in the range of 10 4 –3 × 10 7 cm -2 . We demonstrate that the open circuit voltage ( V oc ) of InGaP solar cells is not significantly influenced by TDDs less than 2 × 10 6 cm -2 . Fabricated InGaP solar cells grown on a Ge-on-Si virtual substrate and a Ge substrate exhibit V oc in the range of 0.96 to 1.43 V under an equivalent illumination in the range of ~0.5 Sun. Finally, the estimated efficiency of the InGaP solar cell fabricated on the Ge-on-Si virtual substrate (Ge substrate) at room temperature for the limited incident spectrum spanning the photon energy range of 1.9–2.4 eV varies from 16.6% to 34.3%.

14 SOLAR ENERGY↗

Study of virtual displays based on raster optical elements

The paper is devoted to the study of the ultimate resolution of virtual displays with raster systems. Raster systems in such displays are used for an essential reduction of their longitudinal overall dimensions. Three schemes are considered: in the first one each element of the raster system forms an image of one pixel only, in the second one each element of the raster system forms a small part of a virtual image, the third scheme is analogous to the first one, but is implemented in the form of a contact lens. For each scheme, we analyse the overall dimensions of the optical system and the characteristics of the virtual image, i.e., the ultimate resolution and the nonuniformity of its illumination. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Complexity of virtual 3-manifolds

Virtual 3-manifolds were introduced by Matveev in 2009 as natural generalizations of classical 3-manifolds. In this paper, we introduce a notion of complexity for a virtual 3-manifold. We investigate the values of the complexity for virtual 3-manifolds presented by special polyhedra with one or two 2-components. On the basis of these results, we establish the exact values of the complexity for a wide class of hyperbolic 3-manifolds with totally geodesic boundary. Bibliography: 24 titles. (paper)

97 MATHEMATICS AND COMPUTING↗

The 23rd National School on Neutron & X-Ray Scattering 2021—Virtual School with Remote Experiments

The National School on Neutron and X-ray Scattering (NXS) has been a yearly “institution” for North American graduate students interested in neutron and X-ray scattering since its inception 23 years ago. For the second year in a row, it was forced to go virtual. Nevertheless, the aim was to include user experiments and maximize interactions in this second virtual iteration rather than simply repeat the lecture series of the first virtual iteration. In this paper, we share our newly adopted methods and experiences.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Virtualization of the ATLAS software environment on a shared HPC system

The shared HPC cluster NEMO at the University of Freiburg has been made available to local ATLAS users through the provisioning of virtual machines incorporating the ATLAS software environment analogously to a WLCG center. This concept allows to run both data analysis and production on the HPC host system which is connected to the existing Tier2/Tier3 infrastructure. Schedulers of the two clusters were integrated in a dynamic, on-demand way. An automatically generated, fully functional virtual machine image provides access to the local user environment. The performance in the virtualized environment is evaluated for typical High-Energy Physics applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Deeply Virtual Exclusive Processes and Generalized Parton Distributions

The goal of the comprehensive program in Deeply Virtual Exclusive Scattering at Jefferson Laboratory is to create transverse spatial images of quarks and gluons as a function of their longitudinal momentum fraction in the proton, the neutron, and in nuclei. These functions are the Generalized Parton Distributions (GPDs) of the target nucleus. Cross section measurements of the Deeply Virtual Compton Scattering (DVCS) reaction ep {yields} ep{gamma} in Hall A support the QCD factorization of the scattering amplitude for Q^2 {>=} 2 GeV^2. Quasi-free neutron-DVCS measurements on the Deuteron indicate sensitivity to the quark angular momentum sum rule. Fully exclusive H(e, e'p{gamma} ) measurements have been made in a wide kinematic range in CLAS with polarized beam, and with both unpolarized and longitudinally polarized targets. Existing models are qualitatively consistent with the JLab data, but there is a clear need for less constrained models. Deeply virtual vector meson production is studied in CLAS. The 12 GeV upgrade will be essential for for these channels. The {rho} and {omega} channels reactions offer the prospect of flavor sensitivity to the quark GPDs, while the {phi}-production channel is dominated by the gluon distribution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Large Q{sup 2} electrodisintegration of the deuteron in the virtual nucleon approximation

The two-body breakup of the deuteron is studied at high-Q{sup 2} kinematics, with the main motivation to probe the deuteron at small internucleon distances. Such studies are associated with the probing of the high-momentum component of the deuteron wave function. For this, two main theoretical issues have been addressed: electromagnetic interaction of the virtual photon with the bound nucleon and the strong interaction of produced baryons in the final state of the breakup reaction. Within virtual nucleon approximation we developed a new prescription to account for the bound nucleon effects in electromagnetic interaction. The final-state interaction at high-Q{sup 2} kinematics is calculated within the generalized eikonal approximation (GEA). We studied the uncertainties involved in the calculation and performed comparisons with the first experimental data on deuteron electrodisintegration at large Q{sup 2}. We demonstrate that the experimental data confirm the GEA's early prediction that the rescattering is maximal at approx70 deg. of recoil nucleon production relative to the momentum of the virtual photon. Comparisons also show that the forward recoil nucleon angles are best suited for studies of the electromagnetic interaction of bound nucleons and the high-momentum structure of the deuteron. Backward recoil angle kinematics show sizable effects owing to the DELTA-isobar contribution. The latter indicates the importance of further development of the GEA to account for the inelastic transitions in the intermediate state of the electrodisintegration reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Local two-photon couplings and the J=0 fixed pole in real and virtual Compton scattering

The local coupling of two photons to the fundamental quark currents of a hadron gives an energy-independent contribution to the Compton amplitude proportional to the charge squared of the struck quark, a contribution which has no analog in hadron scattering reactions. We show that this local contribution has a real phase and is universal, giving the same contribution for real or virtual Compton scattering for any photon virtuality and skewness at fixed momentum transfer squared t. The t dependence of this J=0 fixed Regge pole is parameterized by a yet unmeasured even charge-conjugation form factor of the target nucleon. The t=0 limit gives an important constraint on the dependence of the nucleon mass on the quark mass through the Weisberger relation. We discuss how this 1/x form factor can be extracted from high-energy deeply virtual Compton scattering and examine predictions given by models of the H generalized parton distribution.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Doubly virtual ( π 0 , η , η ' ) → γ * γ * transition form factors in the light-front quark model

We report our investigation on the doubly virtual transition form factors (TFFs) F P γ * ( Q 1 2 , Q 2 2 ) for the P → γ * ( q 1 ) γ * ( q 2 ) ( P = π 0 , η , η ' ) transitions using the light-front quark model (LFQM). Performing a LF calculation in the exactly solvable manifestly covariant Bethe-Salpeter (BS) model as the first illustration, we use the q 1 + = 0 frame and find that both LF and manifestly covariant calculations produce exactly the same results for F P γ * ( Q 1 2 , Q 2 2 ) . This confirms the absence of the LF zero mode in the doubly virtual TFFs. We then map this covariant BS model to the standard LFQM using the more phenomenologically accessible Gaussian wave function provided by the LFQM analysis of meson mass spectra. For the numerical analyses of F P γ * ( Q 1 2 , Q 2 2 ) , we compare our LFQM results with the available experimental data and the perturbative QCD (pQCD) and vector meson dominance (VMD) model predictions. As ( Q 1 2 , Q 2 2 ) → ∞ , our LFQM result for doubly virtual TFF is consistent with the pQCD prediction, i.e., F P γ * ( Q 1 2 , Q 2 2 ) ~ 1 / ( Q 1 2 + Q 2 2 ) , while it differs greatly from the result of the VMD model, which behaves as F P γ * VMD ( Q 1 2 , Q 2 2 ) ~ 1 / ( Q 1 2 Q 2 2 ) . Our LFQM prediction for F η ' γ * ( Q 1 2 , Q 2 2 ) shows an agreement with the very recent experimental data obtained from the BABAR Collaboration for the ranges of 2 < ( Q 1 2 , Q 2 2 ) < 60 GeV 2 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Exploring the Structure of the Bound Proton with Deeply Virtual Compton Scattering

In the past two decades, deeply virtual Compton scattering of electrons has been successfully used to advance our knowledge of the partonic structure of the free proton and investigate correlations between the transverse position and the longitudinal momentum of quarks inside the nucleon. Meanwhile, the structure of bound nucleons in nuclei has been studied in inclusive deep-inelastic lepton scattering experiments off nuclear targets, showing a significant difference in longitudinal momentum distribution of quarks inside the bound nucleon, known as the EMC effect. In this work, we report the first beam spin asymmetry (BSA) measurement of exclusive deeply virtual Compton scattering (DVCS) off a proton bound in $^4$He. The data used here were accumulated using a $6$ GeV longitudinally polarized electron beam incident on a pressurized $^4$He gaseous target placed within the CLAS spectrometer in Hall-B at the Thomas Jefferson National Accelerator Facility. Here, the azimuthal angle ($\phi$) dependence of the BSA was studied in a wide range of virtual photon and scattered proton kinematics. The $Q^2$, $x_B$, and t dependencies of the BSA on the bound proton are compared with those on the free proton. In the whole kinematical region of our measurements, the BSA on the bound proton is smaller by 20\% to 40\%, indicating possible medium modification of its partonic structure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Virtual Neuron: A Neuromorphic Approach for Encoding Numbers

Neuromorphic computers perform computations by emulating the human brain and are expected to be indispensable for energy-efficient computing in the future. They are primarily used in spiking neural network-based machine learning applications. However, neuromorphic computers are unable to preprocess data for these applications. Currently, data is preprocessed on a CPU or a GPU-this incurs a significant cost of transferring data from the CPU/GPU to the neuromorphic processor and vice versa. This cost can be avoided if preprocessing is done on the neuromorphic processor. To efficiently preprocess data on a neuromorphic processor, we first need an efficient mechanism for encoding data that can lend itself to all general-purpose preprocessing operations. Current encoding approaches have limited applicability and may not be suitable for all preprocessing operations. In this paper, we present the virtual neuron as a mechanism for encoding integers and rational numbers on neuromorphic processors. We evaluate the performance of the virtual neuron on physical and simulated neuromorphic hardware and show that it can perform an addition operation using 23 nJ of energy on average using a mixed-signal, memristor-based neuromorphic processor. The virtual neuron encoding approach is the first step in preprocessing data on a neuromorphic processor.

Date, Prasanna↗

Optimizing the accuracy of a helical diode array dosimeter: A comprehensive calibration methodology coupled with a novel virtual inclinometer

Purpose: The goal of any dosimeter is to be as accurate as possible when measuring absolute dose to compare with calculated dose. This limits the uncertainties associated with the dosimeter itself and allows the task of dose QA to focus on detecting errors in the treatment planning (TPS) and/or delivery systems. This work introduces enhancements to the measurement accuracy of a 3D dosimeter comprised of a helical plane of diodes in a volumetric phantom. Methods: We describe the methods and derivations of new corrections that account for repetition rate dependence, intrinsic relative sensitivity per diode, field size dependence based on the dynamic field size determination, and positional correction. Required and described is an accurate ''virtual inclinometer'' algorithm. The system allows for calibrating the array directly against an ion chamber signal collected with high angular resolution. These enhancements are quantitatively validated using several strategies including ion chamber measurements taken using a ''blank'' plastic shell mimicking the actual phantom, and comparison to high resolution dose calculations for a variety of fields: static, simple arcs, and VMAT. A number of sophisticated treatment planning algorithms were benchmarked against ion chamber measurements for their ability to handle a large air cavity in the phantom. Results: Each calibration correction is quantified and presented vs its independent variable(s). The virtual inclinometer is validated by direct comparison to the gantry angle vs time data from machine log files. The effects of the calibration are quantified and improvements are seen in the dose agreement with the ion chamber reference measurements and with the TPS calculations. These improved agreements are a result of removing prior limitations and assumptions in the calibration methodology. Average gamma analysis passing rates for VMAT plans based on the AAPM TG-119 report are 98.4 and 93.3% for the 3%/3 mm and 2%/2 mm dose-error/distance to agreement threshold criteria, respectively, with the global dose-error normalization. With the local dose-error normalization, the average passing rates are reduced to 94.6 and 85.7% for the 3%/3 mm and 2%/2 mm criteria, respectively. Some algorithms in the convolution/superposition family are not sufficiently accurate in predicting the exit dose in the presence of a 15 cm diameter air cavity. Conclusions: Introduction of the improved calibration methodology, enabled by a robust virtual inclinometer algorithm, improves the accuracy of the dosimeter's absolute dose measurements. With our treatment planning and delivery chain, gamma analysis passing rates for the VMAT plans based on the AAPM TG-119 report are expected to be above 91% and average at about 95% level for {gamma}(3%/3 mm) with the local dose-error normalization. This stringent comparison methodology is more indicative of the true VMAT system commissioning accuracy compared to the often quoted dose-error normalization to a single high value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of the accuracy of 3DVH software estimates of dose to virtual ion chamber and film in composite IMRT QA

Purpose: A novel patient-specific intensity modulated radiation therapy (IMRT) QA system, 3DVH software and mapcheck 2, purports to be able to use diode array-measured beam doses and the patient's DICOM RT plan, structure set, and dose files to predict the delivered 3D dose distribution in the patient for comparison to the treatment planning system (TPS) calculated doses. In this study, the composite dose to an ion chamber and film in phantom predicted by the 3DVH and mapcheck 2 system is compared to the actual measured chamber and film doses. If validated in this context, then 3DVH can be used to perform an equivalent dose analysis as that obtained with film dosimetry and ion chamber-based composite IMRT QA. This is important for those losing their ability to perform film dosimetry for true composite IMRT QA and provides a measure of confidence in the accuracy of 3DVH 3D dose calculations which may replace phantom-based IMRT QA. Methods: The dosimetric results from 15 consecutive patient-specific IMRT QA tests performed by composite field irradiation of ion chamber and EDR2 film in a solid water phantom were compared to the predicted doses for those virtual detectors based on the calculated 3D dose by the 3DVH software using mapcheck 2 measured doses of each beam within each plan. For each of the 15 cases, immediately after performing the ion chamber plus film measurements, the mapcheck 2 was used to measure the dose for each beam of the plan. The dose to the volume of the virtual ion chamber and the dose distribution in the plane of the virtual film calculated by the 3DVH software was extracted. The ratio of the measured to 3DVH or eclipse-predicted ion chamber doses was calculated. The same plane in the phantom measured using film and calculated with eclipse was exported from 3DVH and the 2D gamma metric was used to compare the relationship between the film doses and the eclipse or 3DVH predicted planar doses. Also, the 3D gamma value was calculated in the 3DVH software which compares the eclipse dose to the 3DVH predicted dose distribution. For the 2D and 3D gamma metrics, 2% dose and 2 mm distance to agreement (DTA) were used. In addition, a simple dose difference was performed using either a 2% or 3% dose difference tolerance. Results: The mean ratio {+-} standard deviation of the measured vs 3DVH or vs eclipse-predicted dose to the ion chamber was 1.013 {+-} 0.015 and 1.003 {+-} 0.012, respectively. For 3DVH vs eclipse, the mean percentage of pixels failing the 3D gamma metric was 1.2% {+-} 1.4% while the failure rate for the 2D gamma metric was 1.1% {+-} 0.9%. When either 3DVH or eclipse was compared to EDR2 film, the gamma failure rate was 2.3% {+-} 2.0% and 1.6% {+-} 1.7%, respectively. Mean dose difference failures were 9%-27% {+-} 5%-15% for 2 or 3% dose difference tolerances, depending on the combination of systems tested. No statistically significant differences were found for any of the planar dosimetric comparisons. Conclusions: 3DVH + mapcheck 2 predicts the same absolute dose, the percent of pixels failing the gamma metric, and the percent of pixels failing 2% or 3% dose difference tolerance tests as one would have obtained had one made measurements in solid water phantom using an ion chamber and coronal film instead of a diode array. This is also a necessary although not sufficient condition for validation of the accuracy of 3DVH predictions of the 3D dose using beam-by-beam measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-J-167: Improvement of Time-Ordered Four Dimensional Cone-Beam CT; Image Mosaicing with Real and Virtual Projections

Purpose: In the previous study, we developed time-ordered fourdimensional (4D) cone-beam CT (CBCT) technique to visualize nonperiodic organ motion, such as peristaltic motion of gastrointestinal organs and adjacent area, using half-scan reconstruction method. One important obstacle was that truncation of projection was caused by asymmetric location of flat-panel detector (FPD) in order to cover whole abdomen or pelvis in one rotation. In this study, we propose image mosaicing to extend projection data to make possible to reconstruct full field-of-view (FOV) image using half-scan reconstruction. Methods: The projections of prostate cancer patients were acquired using the X-ray Volume Imaging system (XVI, version 4.5) on Synergy linear accelerator system (Elekta, UK). The XVI system has three options of FOV, S, M and L, and M FOV was chosen for pelvic CBCT acquisition, with a FPD panel 11.5 cm offset. The method to produce extended projections consists of three main steps: First, normal three-dimensional (3D) reconstruction which contains whole pelvis was implemented using real projections. Second, virtual projections were produced by reprojection process of the reconstructed 3D image. Third, real and virtual projections in each angle were combined into one extended mosaic projection. Then, 4D CBCT images were reconstructed using our inhouse reconstruction software based on Feldkamp, Davis and Kress algorithm. The angular range of each reconstruction phase in the 4D reconstruction was 180 degrees, and the range moved as time progressed. Results: Projection data were successfully extended without discontinuous boundary between real and virtual projections. Using mosaic projections, 4D CBCT image sets were reconstructed without artifacts caused by the truncation, and thus, whole pelvis was clearly visible. Conclusion: The present method provides extended projections which contain whole pelvis. The presented reconstruction method also enables time-ordered 4D CBCT reconstruction of organs with non-periodic motion with full FOV without projection-truncation artifacts. This work was partly supported by the JSPS Core-to-Core Program(No. 23003). This work was partly supported by JSPS KAKENHI 24234567.

60 APPLIED LIFE SCIENCES↗

WE-EF-BRA-07: High Performance Preclinical Irradiation Through Optimized Dual Focal Spot Dose Painting and Online Virtual Isocenter Radiation Field Targeting

Purpose: Advances in radiotherapy practice facilitated by collimation systems to shape radiation fields and image guidance to target these conformal beams have motivated proposals for more complex dose patterns to improve the therapeutic ratio. Recent progress in small animal radiotherapy platforms has provided the foundation to validate the efficacy of such interventions, but robustly delivering heterogeneous dose distributions at the scale and accuracy demanded by preclinical studies remains challenging. This work proposes a dual focal spot optimization method to paint spatially heterogeneous dose regions and an online virtual isocenter targeting method to accurately target the dose distributions. Methods: Two-dimensional dose kernels were empirically measured for the 1 mm diameter circular collimator with radiochromic film in a solid water phantom for the small and large x-ray focal spots on the X-RAD 225Cx microirradiator. These kernels were used in an optimization framework which determined a set of animal stage positions, beam-on times, and focal spot settings to optimally deliver a given desired dose distribution. An online method was developed which defined a virtual treatment isocenter based on a single image projection of the collimated radiation field. The method was demonstrated by optimization of a 6 mm circular 2 Gy target adjoining a 4 mm semicircular avoidance region. Results: The dual focal spot technique improved the optimized dose distribution with the proportion of avoidance region receiving more than 0.5 Gy reduced by 40% compared to the large focal spot technique. Targeting tests performed by irradiating ball bearing targets on radiochromic film pieced revealed the online targeting method improved the three-dimensional accuracy from 0.48 mm to 0.15 mm. Conclusion: The dual focal spot optimization and online virtual isocenter targeting framework is a robust option for delivering dose at the preclinical level and provides a new experimental option for unique radiobiological investigations This work is supported, in part, by the Natural Sciences and Engineering Research Council of Canada and a Mitacs-Accelerate fellowship. P.E. Lindsay, and D.A. Jaffray are listed as inventors of the system described herein. This system has been licensed to Precision X-Ray Inc. for commercial development.

60 APPLIED LIFE SCIENCES↗

A virtual simulator designed for collision prevention in proton therapy

Purpose: In proton therapy, collisions between the patient and nozzle potentially occur because of the large nozzle structure and efforts to minimize the air gap. Thus, software was developed to predict such collisions between the nozzle and patient using treatment virtual simulation. Methods: Three-dimensional (3D) modeling of a gantry inner-floor, nozzle, and robotic-couch was performed using SolidWorks based on the manufacturer’s machine data. To obtain patient body information, a 3D-scanner was utilized right before CT scanning. Using the acquired images, a 3D-image of the patient’s body contour was reconstructed. The accuracy of the image was confirmed against the CT image of a humanoid phantom. The machine components and the virtual patient were combined on the treatment-room coordinate system, resulting in a virtual simulator. The simulator simulated the motion of its components such as rotation and translation of the gantry, nozzle, and couch in real scale. A collision, if any, was examined both in static and dynamic modes. The static mode assessed collisions only at fixed positions of the machine’s components, while the dynamic mode operated any time a component was in motion. A collision was identified if any voxels of two components, e.g., the nozzle and the patient or couch, overlapped when calculating volume locations. The event and collision point were visualized, and collision volumes were reported. Results: All components were successfully assembled, and the motions were accurately controlled. The 3D-shape of the phantom agreed with CT images within a deviation of 2 mm. Collision situations were simulated within minutes, and the results were displayed and reported. Conclusions: The developed software will be useful in improving patient safety and clinical efficiency of proton therapy.

60 APPLIED LIFE SCIENCES↗