Search NASA⌕ Search

SEARCH · Search NASA

Results for “Voltage Acceleration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Flight Readiness of Mochii S: Portable Spectroscopic Scanning Electron Microscope Facility on the International Space Station (ISS)

The ISS (International Space Station) currently lacks the capability to image and chemically analyze nano-to-micron scale particles from numerous engineering systems. To identify these particles, we must wait for a re-entry vehicle to return them from low earth orbit for ground-based SEM (Scanning Electron Microscope) / EDS (Energy Dispersive X-Ray Spectroscopy) analysis. This may take months, potentially delaying the affected system. Having an EDS-equipped SEM (Mochii S) aboard the ISS will accelerate response time thereby enhancing crew and vehicle safety by rapid and accurate identification of microscopic threats, especially in time-critical situations.The Mochii S payload will be stationed in the Japanese Experiment Module (JEM) powered by 120 VAC (Volts Alternating Current) inverter and connected to station Ethernet and WiFi (Fig. 1). To date the Mochii S payload has undergone testing for command and data handling, power quality, flight vibration, and radiation testing at Johnson Space Center (JSC). Mochii's high-RPM (Revolutions Per Minute) rotating vacuum pumps and high voltage systems have been reviewed to meet safety standards by JSC (Johnson Space Center) Engineering. Topology of the system in the JEM module has been baselined by ISS Safety and JAXA (Japan Space Exploration Agency). Digital controls to and from ISS over Joint Station LAN (Local Area Network) uplink have been simulated and the latencies and data rates have been found to be sufficient for successful operation of the payload from ground.Transporting sensitive electron optical instruments aboard a rocket that sustains 7G acceleration for 8 minutes and then operating it the unique microgravity (micro-g) environment is no trivial matter. To meet strict safety requirements and increase robustness for mission success, over 500 unique verifications must be completed before the payload is certified for spaceflight. Two of which will be discussed in detail are: vibroacoustic testing and magnetic susceptibility shielding and validation.

Mochii↗

Cathodes Delivered for Space Station Plasma Contactor System

The International Space Station's (ISS) power system is designed with high-voltage solar arrays that typically operate at output voltages of 140 to 160 volts (V). The ISS grounding scheme electrically ties the habitat modules, structure, and radiators to the negative tap of the solar arrays. Without some active charge control method, this electrical configuration and the plasma current balance would cause the habitat modules, structure, and radiators to float to voltages as large as -120 V with respect to the ambient space plasma. With such large negative floating potentials, the ISS could have deleterious interactions with the space plasma. These interactions could include arcing through insulating surfaces and sputtering of conductive surfaces as ions are accelerated by the spacecraft plasma sheath. A plasma contactor system was baselined on the ISS to prevent arcing and sputtering. The sole requirement for the system is contained within a single directive (SSP 30000, paragraph 3.1.3.2.1.8): "The Space Station structure floating potential at all points on the Space Station shall be controlled to within 40 V of the ionospheric plasma potential using a plasma contactor." NASA is developing this plasma contactor as part of the ISS electrical power system. For ISS, efficient and rapid emission of high electron currents is required from the plasma contactor system under conditions of variable and uncertain current demand. A hollow cathode plasma source is well suited for this application and was, therefore, selected as the design approach for the station plasma contactor system. In addition to the plasma source, which is referred to as a hollow cathode assembly, or HCA, the plasma contactor system includes two other subsystems. These are the power electronics unit and the xenon gas feed system. The Rocketdyne Division of Boeing North American is responsible for the design, fabrication, assembly, test, and integration of the plasma contactor system. Because of technical and schedule considerations, the NASA Lewis Research Center was asked to manufacture and deliver the engineering model, the qualification model, and the flight HCA units for the plasma contactor system as government furnished equipment. To date, multiple units have been built. One cathode has demonstrated approximately 28 000-hr lifetime, two development HCA units have demonstrated over 15 000-hr lifetime, and one HCA unit has demonstrated more than 38 000 ignitions. All eight flight HCA's have been manufactured, acceptance tested, and are ready for delivery to the flight contractor.

Patterson, Michael J.↗

Investigating Premature Ignition of Thruster Pressure Cartridges by Vibration-Induced Electrostatic Discharge

Pyrotechnic thruster pressure cartridges (TPCs) are used for aeroshell separation on a new NASA crew launch vehicle. Nondestructive evaluation (NDE) during TPC acceptance testing indicated that internal assemblies moved during shock and vibration testing due to an internal bond anomaly. This caused concerns that the launch environment might produce the same movement and release propellant grains that might be prematurely ignited through impact or through electrostatic discharge (ESD) as grains vibrated against internal surfaces. Since a new lot could not be fabricated in time, a determination had to be made as to whether the lot was acceptable to fly. This paper discusses the ESD evaluation and a separate paper addresses the impact problem. A challenge to straight forward assessment existed due to the unavailability of triboelectric data characterizing the static charging characteristics of the propellants within the TPC. The approach examined the physical limitations for charge buildup within the TPC system geometry and evaluated it for discharge under simulated vibrations used to qualify components for launch. A facsimile TPC was fabricated using SS 301 for the case and surrogate worst case materials for the propellants based on triboelectric data. System discharge behavior was evaluated by applying high voltage to the point of discharge in air and by placing worst case charge accumulations within the facsimile TPC and forcing discharge. The facsimile TPC contained simulated propellant grains and lycopodium, a well characterized indicator for static discharge in dust explosions, and was subjected to accelerations equivalent to the maximum accelerations possible during launch. The magnitude of charge generated within the facsimile TPC system was demonstrated to lie in a range of 100 to 10,000 times smaller than the spark energies measured to ignite propellant grains in industry standard discharge tests. The test apparatus, methodology, and results are described in this paper.

Woods, Stephen S.↗

Electric Sail Propulsion for Exploring Nearby Interstellar Space

An Electric Sail is a revolutionary propellant-less propulsion system that is ideal for deep space missions to the outer planets, the Heliopause, and beyond. It is revolutionary in that it uses momentum exchange with the hypersonic solar wind to propel a spacecraft within the heliosphere. The momentum exchange is affected by the deflection of charged solar wind particles by an array of electrically biased wires that extend outward up to 30 km from a slowly rotating spacecraft. A high-voltage, positive bias on the wires, which are oriented normal to the solar wind flow, deflects the streaming protons, resulting in a reaction force on the wires that is also directed radially away from the sun. Over a period of months, this small force can accelerate the spacecraft to enormous speeds-on the order of 100-150 km/s (approximately 20 to 30 AU/yr). Unlike solar sails, Electric Sails do not rely on a fixed area to produce thrust. In fact, as they move away from the Sun and solar wind pressure decreases, the area for solar proton momentum transfer becomes larger, increasing system efficiency. As a result, thrust decreases at ≈1/r**(7/6) instead of the ≈1/r**2 rate typical for solar sails. The net effect is that an increased radial range of operation, together with increased thrust, both contribute to higher velocities and shorter total trip times to distant destinations. The MSFC Advanced Concepts Office (ACO) was awarded a Phase II NASA Innovative Advanced Concepts (NIAC) study to mature the technology for possible future demonstration and implementation. Preliminary results indicate that the physics of the system is viable and that a spacecraft propelled by an Electric Sail could reach the Heliopause in less than 15 years - and could be developed within a decade.

Johnson, Les↗

NEXT Propellant Management System Integration With Multiple Ion Thrusters

As a critical part of the NEXT test validation process, a multiple-string integration test was performed on the NEXT propellant management system and ion thrusters. The objectives of this test were to verify that the PMS is capable of providing stable flow control to multiple thrusters operating over the NEXT system throttling range and to demonstrate to potential users that the NEXT PMS is ready for transition to flight. A test plan was developed for the sub-system integration test for verification of PMS and thruster system performance and functionality requirements. Propellant management system calibrations were checked during the single and multi-thruster testing. The low pressure assembly total flow rates to the thruster(s) were within 1.4 percent of the calibrated support equipment flow rates. The inlet pressures to the main, cathode, and neutralizer ports of Thruster PM1R were measured as the PMS operated in 1-thruster, 2-thruster, and 3-thruster configurations. It was found that the inlet pressures to Thruster PM1R for 2-thruster and 3-thruster operation as well as single thruster operation with the PMS compare very favorably indicating that flow rates to Thruster PM1R were similar in all cases. Characterizations of discharge losses, accelerator grid current, and neutralizer performance were performed as more operating thrusters were added to the PMS. There were no variations in these parameters as thrusters were throttled and single and multiple thruster operations were conducted. The propellant management system power consumption was at a fixed voltage to the DCIU and a fixed thermal throttle temperature of 75 C. The total power consumed by the PMS was 10.0, 17.9, and 25.2 W, respectively, for single, 2-thruster, and 3-thruster operation with the PMS. These sub-system integration tests of the PMS, the DCIU Simulator, and multiple thrusters addressed, in part, the NEXT PMS and propulsion system performance and functionality requirements.

Sovey, James S.↗

In-Flight Verification and Validation of Colloid Microthruster Performance

Colloid Micronewton Thrusters (CMNTs) use an electrospray to provide precision spacecraft position and pointing control. They were demonstrated in space for the first time as part of NASA’s Space Technology 7 (ST7) payload hosted by the European Space Agency’s (ESA’s) LISA Pathfinder (LPF) technology demonstration mission in January, 2016. CMNTs were the actuator in the disturbance reduction system (DRS) that provided drag-free operation of the LPF spacecraft, which will be necessary for future gravity wave observatories such as ESA’s Laser Interferometer Space Antenna (LISA) mission, currently in Phase A and scheduled for launch in 2034. The CMNT technology met performance requirements operating at 5-30 µN of thrust with 0.1 µN resolution and ≤0.1 µN/ÖHz thrust noise to deliver the required nanometer-level precision spacecraft control measured by the gravitational reference sensor (GRS) in the ESA LISA Technology Package (LTP). The performance of seven of the eight CMNTs in flight was consistent with ground test results, and as a system, all eight thrusters met mission-level performance requirements. The colloid microthruster performance model of thrust and thrust noise as a function of operational parameters (i.e. beam current, voltage, temperature, etc.) was validated in flight over a wide range of conditions. A model and simulation of the thruster control algorithm was developed and validated with flight data to predict thrust noise. This capability is important for future missions because it relates directly to the acceleration noise on the test masses, which provide the gravity wave measurements. The CMNT thruster model data and validation with LISA Pathfinder/ST7-DRS flight experiments are presented in this paper.

"O'Donnell, James"↗

The 5200 cycle test of an 8-cm diameter Hg ion thruster

An accelerated cycle test was conducted in which an 8-cm Engineering Model Thruster (EMT) prototype successfully completed 5200 on-off cycles and a total of more than 1300hours of thruster operation at a 4.5 mN thrust level. Cathode tip heater powers required for starting and keeper voltages remained well within acceptable limits. The discharge chamber utilization and electrical efficiency were nearly constant over the duration of the test. It was concluded that on-off cyclic operation by itself does not appreciably degrade starting capability or performance of the 8-cm EMT.

Mantenieks, M. A.↗

Comparison Between MAD-IPA Thrust Stand Measurements and Performance Modeling

The high specific impulse values associated with electric propulsion (EP) that allow for higher payload fractions than conventional, chemical propulsion are achieved by the acceleration of ionized propellant (plasma) by electromagnetic body forces. The lifetime of many EP devices is limited by electrode erosion caused by direct plasma-electrode interaction, while the efficiency is often limited by, among other thruster-specific factors, the available power in space. The efficiency can be increased during higher power operation since the amount of power required to ionize the propellant is fixed and decreases as a percentage of the increased input power. Pulsed inductive plasma accelerators [1-3] are a potentially elegant solution to the problems of high power demands and electrode erosion. The former is addressed in the pulsed nature of these devices, which allows for instantaneous operation on the order of megawatts while requiring a continuous supply on the order of only kilowatts, while the latter is addressed by inductive coupling of the thruster to ionized propellant. These devices operate by rapidly (on the order of microseconds) discharging stored energy at a given pulse repetition rate through a coil creating time-varying magnetic and electric fields that cause ionization, current formation and acceleration of propellant away from the coil. While the inductive (contact-less) nature of the energy transfer from the thruster to the propellant alleviates the problem of erosion and enables the use of in-situ and storable propellants incompatible with metallic electrodes, it places high voltage demands (on the order of tens of kilovolts) on the energy storage system to achieve propellant ionization.

Hallock, Ashley K.↗

Computational Investigation of the Near-Field Plasma Plume in Ion-Ion Propulsion

A two-fluid numerical model of plasma flows was developed to investigate the plume of an ion-ion propulsion system. The densities of positive and negative ions, and the associated values of net charge, electric field, and electric potential were calculated as a function of time throughout the domain. The computational domain was chosen to be large enough (25 thruster diameters downstream of the exit plane) to allow for examining the neutralization of the plume. The resulting plasma electric potential and charge neutrality at the downstream end of the domain are shown and they indicate that it is possible to alternatively accelerate oppositely charged ions without the need for an electron-emitting neutralizer and without facing any electric potential hills that could cause stagnation. However, compared to existing literature on ion-ion plasma thrusters, the results from this simulation predict a longer length-scale for voltage decay.

Sankaran, K.↗

5200 cycle of an 8-cm diameter Hg ion thruster

An accelerated cycle test was conducted in which an 8-cm Engineering Model Thruster (EMT) prototype successfully completed 5200 on-off cycles and a total of more than 1300 hours of thruster operation at a 4.5 mN thrust level. Cathode tip heater powers required for starting and keeper voltages remained well within acceptable limits. The discharge chamber utilization and electrical efficiency were nearly constant over the duration of the test. It is concluded that on-off cyclic operation by itself does not appreciably degrade starting capability or performance of the 8-cm EMT.

Mantenieks, M. A.↗

Cycle life test of secondary spacecraft cells

The results of the life cycling program on rechargeable calls are reported. Information on required data, the use of which the data will be put, application details, including orbital description, charge control methods, load rquirements, etc., are given. Cycle tests were performed on 660 sealed, nickel cadmium cells. The cells consisted of seven sample classifications ranging form 3.0 to 20 amp. hours. Nickel cadmium, silver cadmium, and silver zinc sealed cells, excluding synchronous orbit and accelerated test packs were added. The capacities of the nickel cadmium cells, the silver cadmium and the silver zinc cells differed in range of amp hrs. The cells were cylced under different load, charge control, and temperature conditions. All cell packs are recharged by use of a pack voltage limit. All charging is constant current until the voltage limit is reached.

Harkness, J. D.↗

Design and development of a small structurally integrated ion thruster system

A 5 cm structurally integrated ion thruster has been developed for attitude control and stationkeeping of synchronous satellites. With 2-D vectorable grids, thrust is 0.56 mlb at a beam voltage of 1200 V, total mass efficiency is 64%, and electrical efficiency is 46.8%. Nonvectoring thrust of 0.41 is demonstrated at very low specific impulse with dielectric coated grids. Structural integrity is demonstrated with dielectric coated grids for shock (30 G), sinusoidal (9 G), and random (19 G squared/Hz) accelerations. System envelope is 31.6 cm long by 14 cm flange B.C. with a mass of 8.5 kg including 6.2 Kg mercury propellant.

Hyman, J., Jr.↗

Evaluation of Case Size 0603 BME Ceramic Capacitors

High volumetric efficiency of commercial base metal electrode (BME) ceramic capacitors allows for a substantial reduction of weight and sizes of the parts compared to currently used military grade precious metal electrode (PME) capacitors. Insertion of BME capacitors in space applications requires a thorough analysis of their performance and reliability. In this work, six types of cases size 0603 BME capacitors from three vendors have been evaluated. Three types of multilayer ceramic capacitors (MLCCs) were designed for automotive industry and three types for general purposes. Leakage currents in the capacitors have been measured in a wide range of voltages and temperatures, and measurements of breakdown voltages (VBR) have been used to assess the proportion and severity of defects in the parts. The effect of soldering-related thermal shock stresses was evaluated by analysis of distributions of VBR for parts in 'as is' condition and after terminal solder dip testing at 350 C. Highly Accelerated Life Testing (HALT) at different temperatures was used to assess the activation energy of degradation of leakage currents and predict behavior of the parts at life test and normal operating conditions. To address issues related to rework and manual soldering, capacitors were soldered onto different substrates at different soldering conditions. The results show that contrary to a common assumption that large-size capacitors are mostly vulnerable to soldering stresses, cracking in small size capacitors does happen unless special measures are taken during assembly processes.

testing↗

Procedure for developing experimental designs for accelerated tests for service-life prediction

Recommended design procedures to reduce the complete factorial design by retaining information on anticipated important interaction effects, and by generally giving up information on unconditional main effects are discussed. A hypothetical photovoltaic module used in the test design is presented. Judgments were made of the relative importance of various environmental stresses such as UV radiation, abrasion, chemical attack, temperature, mechanical stress, relative humidity and voltage. Consideration is given to a complete factorial design and its graphical representation, elimination of selected test conditions, examination and improvement of an engineering design, and parametric study. The resulting design consists of a mix of conditional main effects and conditional interactions and represents a compromise between engineering and statistical requirements.

Thomas, R. E.↗

Magnetic Characterization of Micro Shutters for James Web Space Telescope (JWST)

Summary of Research that was part of the grant: NASA NAG5 - 13405: Magnetic Characterization of Micro Shutters for James Web Space Telescope (JWST) Period: May 1 2003-October 31 2005 The above funding resulted in following major achievements related to microshutter system for JWST. 1. The original rectangular pattern of magnetic material was changed into magnetic striped pattern to prevent unnecessary twisting during the actuation. The Original geometry favored magnetic remanence vector being oriented along the longer side of the shutter and thus resulting torque caused out of plane twist. Stripe pattern minimizes the out of plane motion and thus prolongs the life-time of microshutter device. 2. We built a new magnetic system (magnetic rotisserie) allowing an accelerated life test of microshutters at various temperatures. This system identified that shutter are capable to withstand as many as several millions of actuating cycles. Our system also identified fabrication related features, like bowing with temperature, collisions with the frame due to misalignment, delaminating of the light shields due to uncontrolled voltage release and poorly fabricated light shields.

Wasilewski, P.↗

Reliability Evaluation of Base-Metal-Electrode (BME) Multilayer Ceramic Capacitors for Space Applications

This paper reports reliability evaluation of BME ceramic capacitors for possible high reliability space-level applications. The study is focused on the construction and microstructure of BME capacitors and their impacts on the capacitor life reliability. First, the examinations of the construction and microstructure of commercial-off-the-shelf (COTS) BME capacitors show great variance in dielectric layer thickness, even among BME capacitors with the same rated voltage. Compared to PME (precious-metal-electrode) capacitors, BME capacitors exhibit a denser and more uniform microstructure, with an average grain size between 0.3 and approximately 0.5 micrometers, which is much less than that of most PME capacitors. The primary reasons that a BME capacitor can be fabricated with more internal electrode layers and less dielectric layer thickness is that it has a fine-grained microstructure and does not shrink much during ceramic sintering. This results in the BME capacitors a very high volumetric efficiency. The reliability of BME and PME capacitors was investigated using highly accelerated life testing (HALT) and regular life testing as per MIL-PRF-123. Most BME capacitors were found to fail· with an early dielectric wearout, followed by a rapid wearout failure mode during the HALT test. When most of the early wearout failures were removed, BME capacitors exhibited a minimum mean time-to-failure of more than 10(exp 5) years. Dielectric thickness was found to be a critical parameter for the reliability of BME capacitors. The number of stacked grains in a dielectric layer appears to play a significant role in determining BME capacitor reliability. Although dielectric layer thickness varies for a given rated voltage in BME capacitors, the number of stacked grains is relatively consistent, typically between 10 and 20. This may suggest that the number of grains per dielectric layer is more critical than the thickness itself for determining the rated voltage and the life expectancy of the BME capacitor. Since BME capacitors have a much smaller grain size than PME capacitors, it is reasonable to predict that BME capacitors with thinner dielectric layers may have an equivalent life expectancy to that of PME capacitors with thicker dielectric layers.

Liu, David (Donghang)↗

Inner Front Pole Cover Erosion in the 12.5 kW HERMeS Hall Thruster Over a Range of Operating Conditions

Erosion characteristics on the cover of the inner front pole in a 12.5 kW Hall thruster were measured over a wide range of operating conditions in tests of 6 to 14 hours duration using an accelerated test method and a very sensitive radioactive tracer-based erosion diagnostic. The operating points included the nominal 300 - 600 V conditions on a constant 20.8 A throttle curve, but included additional conditions at other currents spanning the throttling envelope and measurements at varying magnetic eld strength, facility pressure, and discharge voltage oscillation amplitude. The results show that the 300 V condition produces the highest wear rates on the 20.8 A throttle curve, but that rates actually increase with decreasing current. The wear rate was insensitive to discharge voltage ripple, but increased monotonically with magnetic eld strength, particularly near the inner radius of the pole cover. The inner region was also sensitive to facility pressure, showing lower rates at a higher pressure level. Separate experiments in which the energy distributions of ions generated by the hollow cathode were measured suggest that the cathode plume may be a source of energetic ions responsible for some of the erosion trends, in addition to ions originating in the thruster plume. The Hall thruster simulation code Hall2De is able to reproduce the erosion characteristics observed at 600 V, 20.8 A, but cannot currently match the rates measured at lower voltages and currents.

Lopez Ortega, Alejandro↗

A high voltage power converter for space astronomy applications

A dc-dc low-power, high-voltage converter for use in space is described which furnishes a commandable, low-noise dc output in the range of 0 to -7500 V. The converter is suitable for biasing of detectors commonly employed in space astronomy, microchannel plates, photomultipliers, and gas discharge detectors. The converter's reliability has been demonstrated by accelerated life testing under thermal vacuum. The electrical and mechanical design, packaging, layout and fabrication techniques, and tests employed are described.

Ray, David C.↗