Search NASA⌕ Search

SEARCH · Search NASA

Results for “WATER VAPOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Seasonal to Decadal Variations of Water Vapor in the Tropical Lower Stratosphere Observed with Balloon-Borne Cryogenic Frost Point Hygrometers

We investigated water vapor variations in the tropical lower stratosphere on seasonal, quasi-biennial oscillation (QBO), and decadal time scales using balloon-borne cryogenic frost point hygrometer data taken between 1993 and 2009 during various campaigns including the Central Equatorial Pacific Experiment (March 1993), campaigns once or twice annually during the Soundings of Ozone and Water in the Equatorial Region (SOWER) project in the eastern Pacific (1998-2003) and in the western Pacific and Southeast Asia (2001-2009), and the Ticosonde campaigns and regular sounding at Costa Rica (2005-2009). Quasi-regular sounding data taken at Costa Rica clearly show the tape recorder signal. The observed ascent rates agree well with the ones from the Halogen Occultation Experiment (HALOE) satellite sensor. Average profiles from the recent five SOWER campaigns in the equatorial western, Pacific in northern winter and from the three Ticosonde campaigns at Costa Rica (10degN) in northern summer clearly show two effects of the QBO. One is the vertical displacement of water vapor profiles associated with the QBO meridional circulation anomalies, and the other is the concentration variations associated with the QBO tropopause temperature variations. Time series of cryogenic frost point hygrometer data averaged in a lower stratospheric layer together with HALOE and Aura Microwave Limb Sounder data show the existence of decadal variations: The mixing ratios were higher and increasing in the 1990s, lower in the early 2000s, and probably slightly higher again or recovering after 2004. Thus linear trend analysis is not appropriate to investigate the behavior of the tropical lower stratospheric water vapor.

Fujiwara, M.↗

Remote sensing of seasonal distribution of precipitable water vapor over the oceans and inference of boundary layer structure

Over the ocean satellite infrared spectral measurements in the 18 micrometer water vapor band and the 11 micrometer window region were used to derive precipitable water vapor, w, in the atmosphere and the sea surface temperature, SST. Seasonal maps of w on the oceans derived from these data reveal the dynamical influence of the large scale atmospheric circulation. With the help of a model for the vertical distribution of water vapor, the configuration of the atmospheric boundary layer over the oceans can be inferred from w when the information of SST is combined. The gross seasonal mean structure of the boundary layer inferred in this fashion reveals the broad areas of the trade wind inversion and the convectively active areas such as the intertropical convergence zones.

Prabhakara, C.↗

Spaceborne observation of columnar water vapor - SSMI observations and algorithm

An analysis of the transfer of radiation with a frequency between 10 and 40 GHz through a cloud-free atmosphere is given, and the limitations of employing observations at 22.235 GHz for sensing the columnar water vapor (CWV) in the moist atmosphere (CWV above 40 kg/sq m) are shown. It is because of this limitation that a new method for the retrieval of columnar water vapor is described. This method uses both the horizontally and vertically polarized brightness temperatures measured at 19.35 GHz by the special sensor microwave imager (SSMI) which was launched as part of the Defense Military Satellite Program. The water vapor derived from the SSMI observations is validated against radiosonde observations that are near coincident in time and space with an rms error of 6 kg/sq m. This large rms is in part due to sensitivity of the retrieval method to the surface emission. Distributions of CWV over the oceans were obtained for a 3-month period starting September, 1987. These results are compared to other water vapor retrievals for the same period using the same microwave radiance data; they show close agreement except over the warmest water in the equatorial tropics.

Tjemkes, Stephen A.↗

Water vapor radiometry research and development phase

This report describes the research and development phase for eight dual-channel water vapor radiometers constructed for the Crustal Dynamics Project at the Goddard Space Flight Center, Greenbelt, Maryland, and for the NASA Deep Space Network. These instruments were developed to demonstrate that the variable path delay imposed on microwave radio transmissions by atmospheric water vapor can be calibrated, particularly as this phenomenon affects very long baseline interferometry measurement systems. Water vapor radiometry technology can also be used in systems that involve moist air meteorology and propagation studies.

Resch, G. M.↗

Advances in Raman Lidar Measurements of Water Vapor, Cirrus Clouds and Carbon Dioxide

Narrow-band interference filters with improved transmission in the ultraviolet have been developed under NASA-funded research and used in the Raman Airborne Spectroscopic Lidar (RASL) in ground- based, upward-looking tests. RASL is an airborne Raman Lidar system designed to measure water vapor mixing ratio, and aerosol backscatter/extinction/depolarization. It also possesses the capability to make experimental measurements of cloud liquid water and carbon dioxide. It is being prepared for first flight tests during the summer of 2006. With the newly developed filters installed in RASL, measurements were made of atmospheric water vapor, cirrus cloud optical properties and carbon dioxide that improve upon any previously demonstrated using Raman lidar. Daytime boundary layer profiling of water vapor mixing ratio is performed with less than 5% random error using temporal and spatial resolution of 2-minutes and 60 - 210, respectively. Daytime cirrus cloud optical depth and extinction- to-backscatter ratio measurements are made using 1-minute average. Sufficient signal strength is demonstrated to permit the simultaneous profiling of carbon dioxide and water vapor mixing ratio into the free troposphere during the nighttime. Downward-looking from an airborne RASL should possess the same measurement statistics with approximately a factor of 5 - 10 decrease in averaging time. A description of the technology improvements are provided followed by examples of the improved Raman lidar measurements.

Whiteman, David N.↗

Three-dimensional evolution of water vapor distributions in the Northern Hemisphere stratosphere as observed by the MLS

The three-dimensional evolution of stratospheric water vapor distributions observed by the Microwave Limb Sounder (MLS) during the period October 1991 - July 1992 is documented. The transport features inferred from the MLS water vapor distributions are corroborated using other dynamical fields, namely, nitrous oxide from the Cryogenic Limb Array Etalon Spectrometer instrument, analyzed winds from the U.K. Meteorological Office (UKMO), UKMO-derived potential vorticity, and the diabatic heating field. By taking a vortex-centered view and an along-track view, the authors observe in great detail the vertical and horizontal structure of the northern winter stratosphere. It is demonstrated that the water vapor distributions show clear signatures of the effects of diabatic descent through isentropic surfaces and quasi-horizontal transport along isentropic surfaces, and that the large-scale winter flow is organized by the interaction between the westerly polar vortex and the Aleutian high.

Lahoz, W. A.↗

On the Accuracy of In Situ Water Vapor Measurements in the Troposphere and Lower Stratosphere with the Harvard Lyman-Alpha Hygrometer

In an effort to better constrain atmospheric water vapor mixing ratios and to understand the discrepancies between different measurements of water vapor in the stratosphere and troposphere, we have carefully examined data from the Harvard Lyman-alpha photofragment fluorescence hygrometer, which has flown on the NASA ER-2 aircraft from 1992 through 1998. The instrument is calibrated in the laboratory before and after each deployment, and the calibration is checked by direct absorption measurements in the troposphere. On certain flights, the ER-2 flew level tracks during which water vapor varied by up to 80 ppmv, under nearly constant atmospheric conditions. These flights provide a stringent test of our calibration via direct absorption and indicate agreement to within 3%. During the 1997 Photochemistry of Ozone Loss in the Arctic Region In Summer (POLARIS) mission, our Lyman-alpha instrument was compared with a new diode laser hygrometer from the Jet Propulsion Laboratory. Overall agreement was 5% during the June/July deployment and 1% for potential temperatures of 490 to 540 K. The accuracy of our instrument is shown to be +/-5 %, with an additional offset of at most 0.1 ppmv. Data from this instrument, combined with simultaneous measurements of CH4, and H2, are therefore ideal for studies of the hydrogen budget of the lower stratosphere.

Hintsa, Eric J.↗

Measurements of water vapor in Mars' antarctic

A complete Mars year of measurements of atmospheric water vapor in the south arctic have been obtained from the Viking Orbiters. Analysis of the observations indicates that, except for the south remnant cap, the southern hemisphere of Mars is devoid of any substantial reservoirs of water in contact with the atmosphere, and that, in the summer time, the top layer of soil is desiccated. Small amounts of water ice are incorporated into the annual CO2 cap; this water is released at the cap margin when it retreats in the spring. The first global dust storm resulted in heating of the south arctic atmosphere and a transport of water in from the equatorial region. The second global dust storm had a negligible effect on atmospheric water vapor; the dust contained little water.

Davies, D. W.↗

Theoretical Calculation and Validation of the Water Vapor Continuum Absorption

The primary objective of this investigation is the development of an improved parameterization of the water vapor continuum absorption through the refinement and validation of our existing theoretical formalism. The chief advantage of our approach is the self-consistent, first principles, basis of the formalism which allows us to predict the frequency, temperature and pressure dependence of the continuum absorption as well as provide insights into the physical mechanisms responsible for the continuum absorption. Moreover, our approach is such that the calculated continuum absorption can be easily incorporated into satellite retrieval algorithms and climate models. Accurate determination of the water vapor continuum is essential for the next generation of retrieval algorithms which propose to use the combined constraints of multispectral measurements such as those under development for EOS data analysis (e.g., retrieval algorithms based on MODIS and AIRS measurements); current Pathfinder activities which seek to use the combined constraints of infrared and microwave (e.g., HIRS and MSU) measurements to improve temperature and water profile retrievals, and field campaigns which seek to reconcile spectrally-resolved and broad-band measurements such as those obtained as part of FIRE. Current widely used continuum treatments have been shown to produce spectrally dependent errors, with the magnitude of the error dependent on temperature and abundance which produces errors with a seasonal and latitude dependence. Translated into flux, current water vapor continuum parameterizations produce flux errors of order 10 W/sq m, which compared to the 4 W/sq m magnitude of the greenhouse gas forcing and the 1-2 W/sq m estimated aerosol forcing is certainly climatologically significant and unacceptably large. While it is possible to tune the empirical formalisms, the paucity of laboratory measurements, especially at temperatures of interest for atmospheric applications, preclude tuning, the empirical continuum models over the full spectral range of interest for remote sensing and climate applications. Thus, we propose to further develop and refine our existing, far-wing formalism to provide an improved treatment applicable from the near-infrared through the microwave. Based on the results of this investigation, we will provide to the remote sensing/climate modeling community a practical and accurate tabulation of the continuum absorption covering the near-infrared through the microwave region of the spectrum for the range of temperatures and pressures of interest for atmospheric applications.

Ma, Qiancheng↗

Theoretical Calculation and Validation of the Water Vapor Continuum Absorption

The primary objective of this investigation is the development of an improved parameterization of the water vapor continuum absorption through the refinement and validation of our existing theoretical formalism. The chief advantage of our approach is the self-consistent, first principles, basis of the formalism which allows us to predict the frequency, temperature and pressure dependence of the continuum absorption as well as provide insights into the physical mechanisms responsible for the continuum absorption. Moreover, our approach is such that the calculated continuum absorption can be easily incorporated into satellite retrieval algorithms and climate models. Accurate determination of the water vapor continuum is essential for the next generation of retrieval algorithms which propose to use the combined constraints of multi-spectral measurements such as those under development for EOS data analysis (e.g., retrieval algorithms based on MODIS and AIRS measurements); current Pathfinder activities which seek to use the combined constraints of infrared and microwave (e.g., HIRS and MSU) measurements to improve temperature and water profile retrievals, and field campaigns which seek to reconcile spectrally-resolved and broad-band measurements such as those obtained as part of FIRE. Current widely used continuum treatments have been shown to produce spectrally dependent errors, with the magnitude of the error dependent on temperature and abundance which produces errors with a seasonal and latitude dependence. Translated into flux, current water vapor continuum parameterizations produce flux errors of order 10 W/ml, which compared to the 4 W/m' magnitude of the greenhouse gas forcing and the 1-2 W/m' estimated aerosol forcing is certainly climatologically significant and unacceptably large. While it is possible to tune the empirical formalisms, the paucity of laboratory measurements, especially at temperatures of interest for atmospheric applications, preclude tuning the empirical continuum models over the full spectral range of interest for remote sensing and climate applications. Thus, we propose to further develop and refine our existing far-wing formalism to provide an improved treatment applicable from the near-infrared through the microwave. Based on the results of this investigation, we will provide to the remote sensing/climate modeling community a practical and accurate tabulation of the continuum absorption covering the near-infrared through the microwave region of the spectrum for the range of temperatures and pressures of interest for atmospheric applications.

Ma, Qiancheng↗

Global analyses of water vapor, cloud and precipitation derived from a diagnostic assimilation of SSM/I geophysical retrievals

An analytical approach is described for diagnostically assimilating moisture data from Special Sensor Microwave Imager (SSM/I) into a global analysis of water vapor, cloud content, and precipitation. In this method, 3D fields of wind and temperature values taken from ECMWF gridded analysis are used to drive moisture conservation equations with parameterized microphysical treatment of vapor, liquid, and ice; the evolving field of water vapor is periodically updated or constrained by SSM/I retrievals of precipitable water. Initial results indicate that this diagnostic model can produce realistic large-scale fields of cloud and precipitation. The resulting water vapor analyses agree well with SSM/I and have an additional advantage of being synoptic.

Robertson, Franklin R.↗

Estimating Sampling Biases and Measurement Uncertainties of AIRS-AMSU-A Temperature and Water Vapor Observations Using MERRA Reanalysis

We use MERRA (Modern Era Retrospective-Analysis for Research Applications) temperature and water vapor data to estimate the sampling biases of climatologies derived from the AIRS/AMSU-A (Atmospheric Infrared Sounder/Advanced Microwave Sounding Unit-A) suite of instruments. We separate the total sampling bias into temporal and instrumental components. The temporal component is caused by the AIRS/AMSU-A orbit and swath that are not able to sample all of time and space. The instrumental component is caused by scenes that prevent successful retrievals. The temporal sampling biases are generally smaller than the instrumental sampling biases except in regions with large diurnal variations, such as the boundary layer, where the temporal sampling biases of temperature can be +/- 2 K and water vapor can be 10% wet. The instrumental sampling biases are the main contributor to the total sampling biases and are mainly caused by clouds. They are up to 2 K cold and greater than 30% dry over mid-latitude storm tracks and tropical deep convective cloudy regions and up to 20% wet over stratus regions. However, other factors such as surface emissivity and temperature can also influence the instrumental sampling bias over deserts where the biases can be up to 1 K cold and 10% wet. Some instrumental sampling biases can vary seasonally and/or diurnally. We also estimate the combined measurement uncertainties of temperature and water vapor from AIRS/AMSU-A and MERRA by comparing similarly sampled climatologies from both data sets. The measurement differences are often larger than the sampling biases and have longitudinal variations.

MERRA↗

Temperature sensitivity of differential absorption lidar measurements of water vapor in the 720-nm region

Recently measured properties of water vapor (H2O) absorption lines have been used in calculations to evalute the temperature sensitivity of differential absorption lidar (Dial) H2O measurements. This paper estimates the temperature sensitivity of H2O lines in the 717-733-nm region for both H2O mixing ratio and number density measurements, and discusses the influence of the H2O line ground state energies E-double-prime, the H2O absorption linewidths, the linewidth temperature dependence parameter, and the atmospheric temperature and pressure variations with altitude and location on the temperature sensitivity calculations. Line parameters and temperature sensitivity calculations for 67 H2O lines in the 720-nm band are given which can be directly used in field experiments. Water vapor lines with E-double-prime values in the 100-300/cm range were found to be optimum for Dial measurements of H2O number densities, while E-double-prime values in the 250-500/cm range were found to be optimum for H2O mixing ratio measurements.

Browell, Edward V.↗

Influence of Deep Convection on Cirrus and Water Vapor Concentration in the Upper Troposphere and Lower Stratosphere

It is well known that stratospheric humidity is primarily controlled by freeze drying (ice crystal growth and sedimentation) of air ascending across the cold tropical tropopause. However, the suggestion of an important source of water vapor from deep convection that extends above the tropical tropopause has persisted. There exists much anecdotal evidence of direct convective hydration of the lower stratosphere based on measurements from high altitude aircraft campaigns, but quantifying the impact of deep convection on the overall budget of stratospheric water vapor has proven challenging. The role of convection on the humidity of the upper troposphere and lower stratosphere (UTLS) is investigated in simulations of cirrus clouds along trajectories launched from given potential temperature level surfaces. The one-dimensional (vertical) cloud model tracks individual ice crystals through their life cycles, beginning with nucleation or detrainment from convection, followed by deposition growth, sedimentation and sublimation. Convective influence of the parcels is diagnosed by tracing the trajectories through time-dependent fields of convective cloud-top height adjusted to match the CloudSAT and CALIPSO statistics. Model simulations of UTLS water vapor and cloud fields are evaluated and constrained by comparison with MLS and CALIPSO measurements. The simulation results indicate that the overall impact of convection on water vapor near the tropical tropopause is 10-15%, while the impact on lower stratospheric humidity is no more than a few percent. Ice crystals detrained from deep convection have relatively small effect. The general implications for the importance of deep convection on UTLS humidity and cirrus cloud fraction will be discussed.

Ueyama, Rei↗

Mars: Water Vapor Observations from the Viking Orbiters

The global distribution of the water vapor has been mapped at low resolution throughout the period from the northern summer solstice to the following equinox. During this seasonal period the water vapor underwent a gradual redistribution, the latitude of maximum column abundance moving from the northern polar area to the equatorial latitudes. The total global vapor content remained approximately constant at the equivalent of about 1.3 cu km of ice. The various data obtained indicate that the residual polar caps are composed of water ice.

Farmer, C. B.↗

Alumina Volatility in Water Vapor at Elevated Temperatures

The volatility of alumina in high temperature water vapor was determined by a weight loss technique. Sapphire coupons were exposed at temperatures between 1250 and 1500 C, water partial pressures between 0.15 and 0.68 atm in oxygen, total pressure of 1 atm, and flowing gas velocities of 4.4 cm/s. The pressure dependence of sapphire volatility was consistent with AI(OH)3(g) formation. The enthalpy of reaction to form Al(OH)3(g) from sapphire and water vapor was determined to be 210 +/- 20 kJ/mol, comparing favorably to other studies. Microstructural examination of tested sapphire coupons revealed surface etching features consistent with a volatilization process.

Opila, Elizabeth J.↗

In Situ Water Vapor Measurements Using Coupled UV Fragment Fluorescence/Absorption Spectroscopy in Support of CRYSTAL-FACE

Understanding the coupling of dynamics, chemistry, and radiation within the context of the NASA Earth Science Enterprise (ESE) and the national Climate Change Science Program (CCSP) requires, as a first-order priority, high spatial resolution, high-accuracy observations of water in its various phases. Given the powerful diagnostic importance of the condensed phases of water for dynamics and the impact of phase changes in water on the radiation field, the accurate, in situ observation of water vapor is of central importance to CRYSTAL FACE (CF). This is clear both from the defined scientific objectives of the NRA and from developments in the coupled fields of stratosphere/troposphere exchange, cirrus cloud formation/removal and mechanisms for the distribution of water vapor in the middle/upper troposphere. Accordingly, we were funded under NASA Grant NAG5-11548 to perform the following tasks for the CF mission: 1. Prepare the water vapor instrument for integration into the WB57F and test flights scheduled for Spring 2002. 2. Calibrate and prepare the water vapor instrument for the Summer 2002 CF science flights based in Jacksonville, Florida. 3. Provide both science and engineering support for the above-mentioned efforts. 4. Analyze and interpret the CF data in collaboration with other mission scientists. 5. Attend the science workshop in Spring 2003. 6. Publish the data and analysis in peer-reviewed journals.

Anderson, James G.↗