Search NASA⌕ Search

SEARCH · Search NASA

Results for “ablators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Feasibility Study on MR-Guided High-Intensity Focused Ultrasound Ablation of Sciatic Nerve in a Swine Model: Preliminary Results

IntroductionSpastic patients often seek neurolysis, the permanent destruction of the sciatic nerve, for better pain management. MRI-guided high-intensity focused ultrasound (MRgHIFU) may serve as a noninvasive alternative to the prevailing, more intrusive techniques. This in vivo acute study is aimed at performing sciatic nerve neurolysis using a clinical MRgHIFU system.MethodsThe HIFU ablation of sciatic nerves was performed in swine (n = 5) using a HIFU system integrated with a 3 T MRI scanner. Acute lesions were confirmed using T1-weighted contrast-enhanced (CE) MRI and histopathology using hematoxylin and eosin staining. The animals were euthanized immediately following post-ablation imaging.ResultsReddening and mild thickening of the nerve and pallor of the adjacent muscle were seen in all animals. The HIFU-treated sections of the nerves displayed nuclear pyknosis of Schwann cells, vascular hyperemia, perineural edema, hyalinization of the collagenous stroma of the nerve, myelin sheet swelling, and loss of axons. Ablations were visible on CE MRI. Non-perfused volume of the lesions (5.8–64.6 cc) linearly correlated with estimated lethal thermal dose volume (4.7–34.2 cc). Skin burn adjacent to the largest ablated zone was observed in the first animal. Bilateral treatment time ranged from 55 to 138 min, and preparation time required 2 h on average.ConclusionThe acute pilot study in swine demonstrated the feasibility of a noninvasive neurolysis of the sciatic nerve using a clinical MRgHIFU system. Results revealed that acute HIFU nerve lesions were detectable on CE MRI, gross pathology, and histology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Biopsy and Radiofrequency Ablation of Osteoid Osteoma with Excess Reactive New Bone Formation and Cortical Thickening Using a Battery-Powered Drill for Access: A Technical Note

PurposeTo report our experience with the use of a battery-powered drill in biopsy and radiofrequency ablation of osteoid osteoma with excess reactive new bone formation. The battery-powered drill enables obtaining the sample while drilling.Materials and MethodsDuring the last 18 months, 14 patients suffering from painful osteoid osteoma with excess reactive new bone formation underwent CT-guided biopsy and radiofrequency ablation. In order to assess and sample the nidus of the osteoid osteoma, a battery-powered drill was used. Biopsy was performed in all cases. Then, coaxially, a radiofrequency electrode was inserted and ablation was performed with osteoid osteoma protocol. Procedure time (i.e., drilling including local anesthesia), amount of scans, technical and clinical success, and the results of biopsy are reported.ResultsAccess to the nidus through the excess reactive new bone formation was feasible in all cases. Median procedure time was 50.5 min. Histologic verification of osteoid osteoma was performed in all cases. Radiofrequency electrode was coaxially inserted within the nidus and ablation was successfully performed in all lesions. Median amount CT scans, performed to control correct positioning of the drill and precise electrode placement within the nidus was 11. There were no complications or material failure reported in our study.ConclusionsThe use of battery-powered drill facilitates access to the osteoid osteoma nidus in cases where excess reactive new bone formation is present. Biopsy needle can be used for channel creation during the access offering at the same time the possibility to extract bone samples.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Propofol Compared to Midazolam Sedation and to General Anesthesia for Percutaneous Microwave Ablation in Patients with Hepatic Malignancies: A Single-Center Comparative Analysis of Three Historical Cohorts

Purpose: In percutaneous ablation procedures, periprocedural pain, unrest and respiratory concerns can be detrimental to achieve a safe and efficacious ablation and impair treatment outcome. This study aimed to compare the association between anesthetic technique and local disease control in patients undergoing percutaneous microwave ablation (MWA) of colorectal liver metastases (CRLM) and hepatocellular carcinoma (HCC). Materials and Methods: This IRB-exempted single-center comparative, retrospective analysis of three cohorts analyzed 90 patients treated for hepatic malignancies from January 2013 until September 2018. The local tumor progression-free survival (LTPFS), safety and periprocedural pain perception were assessed using univariate and multivariate Cox proportional hazard regression analyses to correct for potential confounders. Results: In 114 procedures (22 general anesthesia; 32 midazolam; 60 propofol), 171 liver tumors (136 CRLM; 35 HCC) were treated with percutaneous MWA. Propofol and general anesthesia were superior to midazolam/fentanyl sedation regarding LTPFS (4/94 [4.3%] vs. 19/42 [45.2%] vs. 2/35 [5.7%]; P < 0.001, respectively). Local tumor progression rate was 14.6% (25/171). Eighteen tumors (72.0%) were retreated by ablation. Of them, 14 (78%) were previously treated with midazolam. Propofol versus midazolam (P < 0.001), general anesthesia versus midazolam (P = 0.016), direct postprocedural visual analog pain score above 5 (P = 0.050) and more than one tumor per procedure (P = 0.045) were predictors for LTPFS. Multivariate analysis revealed that propofol versus midazolam (HR 7.94 [95% CI 0.04–0.39; P < 0.001]) and general anesthesia versus midazolam (HR 6.33 [95% CI 0.04–0.69; P = 0.014]) were associated with LTPFS. Pain during and directly after treatment was significantly worse in patients who received midazolam sedation (P < 0.001). Conclusions: Compared to propofol and general anesthesia, midazolam/fentanyl sedation was associated with an increased periprocedural perception of pain and lower local tumor progression-free survival. To reduce the number of repeat procedures required to eradicate hepatic malignancies, general anesthesia and propofol sedation should be favored over midazolam.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Laser Ablation of Alumina in Water

Bulk {alpha}-alumina immersed in distilled water was ablated by pulsed UV laser radiation. The resulting colloidal solution contained micron and submicron size particles. X-ray diffraction and Raman spectra of the ablated and original material are similar. Hence, most of the ablated material is {alpha}-alumina. From transmission electron microscope images, most of the submicron and all of the micron-sized particles have sharp edges and do not have spherical shapes, indicating that the dominant ablation mechanism is due to crack propagation. Some spherical particles of diameter less than 100 nm are observed, indicating that they were formed from the liquid state.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Enhanced Pu emission with solution-loaded laser ablation modified sources (SLLAMS) for thermal ionization mass spectrometry

This study presents a new approach to filament modification by laser ablation for analysis of femtograms of plutonium (Pu) by thermal ionization mass spectrometry (TIMS). This method simplifies the often rigorous and labor-intensive sample loading necessary for low-level analyses by TIMS with solution-loaded laser ablation modified sources (SLLAMS). By applying a para-film coating to the surface of the filament and then ablating through the film to reveal metal beneath, a point source is created. A solution containing ppt-levels of Pu can then be applied over the ablated region, dried slowly into the crater, and then carburized. All analyses were made by multiple ion counting system of a Nu Instruments TIMS. Furthermore, we report errors of 10% 2σ for 240 Pu/ 239 Pu of CRM-137 samples totaling 5 – 7 femtograms (fg; 1E-15 g) with an average sample utilization efficiency of 1.3%. Results from SLLAMS demonstrate an improvement in precision, accuracy and ease of use over resin bead loads.

47 OTHER INSTRUMENTATION↗

Optical properties of petal-like aggregated nanocrystalline zinc oxide synthesized by laser ablation

Highlights: Black-Right-Pointing-Pointer Petal like ZnO nanocrystals are synthesized by high frequency laser ablation in water. Black-Right-Pointing-Pointer Optical band gap of ZnO nanocrystals was tunable by changing the laser pulse energy. Black-Right-Pointing-Pointer Nonlinear optical properties and limiting threshold were obtained by Z-scan technique. -- Abstract: The results of the investigations carried out on the third-order nonlinearity in zinc oxide (ZnO) nanocrystals (NCs) by Z-scan technique are included in this paper. ZnO NCs show negative nonlinearity and good nonlinear absorption behavior at 532 nm. The third-order optical susceptibility {chi}(3) increases with enlargement of NCs due to the size dependent enhancement of exciton oscillator strength. The synthesis of ZnO NCs was performed by laser ablation from a high-purity metallic target of Zn in distilled water medium. For the ablation process, a high frequency pulsed Nd:YAG laser was employed operating at 532 nm with 100 ns pulse duration. UV-vis absorption spectroscopy illustrated the enhancement of the size of ZnO NCs upon increasing the laser pulse energy applied in ablation process. Accordingly the corresponding optical band gap (E{sub g}) decrease by increasing the size of NCs. X-ray diffraction (XRD) associated with transmission electron microscopy (TEM) was utilized to characterize the crystalline phase and also for determining the ZnO NCs morphology.

36 MATERIALS SCIENCE↗

Ablation of (GeS{sub 2}){sub 0.3}(Sb{sub 2}S{sub 3}){sub 0.7} glass with an ultra-violet nano-second laser

Highlights: • The interaction of (GeS{sub 2}){sub 0.3}(Sb{sub 2}S{sub 3}){sub 0.7} bulk glass and film with UV nanosecond laser. • Ablation process, topography of crater and structure of the material were studied. • Ablation threshold fluencies changed with the spot diameter and number of pulses. • The photo-thermal expansion of the material occurred for low laser fluency. • Laser direct writing process applicable for fabrication of passive optical elements. - Abstract: The results of an experimental study of the laser ablation of bulk and thin films of a GeSbS chalcogenide glass using UV nanosecond pulses are reported. The response of the samples to illumination conditions was studied through the use of atomic force spectroscopy, digital holographic microscopy, Raman scattering and scanning electron microscopy. The multi-pulse ablation thresholds were determined for both the bulk and thin film samples for varying number of pulses and illuminated spot diameter. The possible application of direct laser writing into the bulk and thin films of this material is presented.

36 MATERIALS SCIENCE↗

Laser Ablation Sampling of Materials Directly into the Formed Liquid Microjunction of a Continuous Flow Surface Sampling Probe/Electrospray Ionization Emitter for Mass Spectral Analysis and Imaging

Transmission geometry laser ablation directly into a formed liquid microjunction of a continuous flow liquid microjunction surface sampling probe/electrospray ionization emitter was utilized for molecular and elemental detection and mass spectrometry imaging. The ability to efficiently capture and ionize ablated material was demonstrated by the detection of various small soluble n-mers of polyaniline and silver ion solvent clusters formed from laser ablation of electropolymerized polyaniline and silver thin films, respectively. In addition, analysis of surfaces that contain soluble components was accomplished by coating or laminating the sample with an insoluble film to enable liquid junction formation without directly extracting material from the surface. The ability to perform mass spectrometry imaging at a spatial resolution of about 50 m was illustrated by using laminated inked patterns on a microscope slide. In general, these data demonstrate at least an order of magnitude signal enhancement compared to the non-contact, laser ablation droplet capture-based surface sampling/ionization approaches that have been previously presented.

electrospray ionization (ESI)↗

Characterization and Application of a Hybrid Optical Microscopy/Laser Ablation Liquid Vortex Capture/Electrospray Ionization System for Mass Spectrometry Imaging with Sub-micrometer Spatial Resolution

Herein, a commercial optical microscope, laser microdissection instrument was coupled with an electrospray ionization mass spectrometer via a low profile liquid vortex capture probe to yield a hybrid optical microscopy/mass spectrometry imaging system. The instrument has bright-field and fluorescence microscopy capabilities in addition to a highly focused UV laser beam that is utilized for laser ablation of samples. With this system, material laser ablated from a sample using the microscope was caught by a liquid vortex capture probe and transported in solution for analysis by electrospray ionization mass spectrometry. Both lane scanning and spot sampling mass spectral imaging modes were used. The smallest area the system was able to ablate was ~0.544 μm × ~0.544 μm, achieved by oversampling of the smallest laser ablation spot size that could be obtained (~1.9 μm). With use of a model photoresist surface, known features as small as ~1.5 μm were resolved. The capabilities of the system with real world samples were demonstrated first with a blended polymer thin film containing poly(2-vinylpyridine) and poly(N-vinylcarbazole). Using spot sampling imaging, sub-micrometer sized features (0.62, 0.86, and 0.98 μm) visible by optical microscopy were clearly distinguished in the mass spectral images. A second real world example showed the imaging of trace amounts of cocaine in mouse brain thin tissue sections. Lastly, with use of a lane scanning mode with ~6 μm × ~6 μm data pixels, features in the tissue as small as 15 μm in size could be distinguished in both the mass spectral and optical images.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

On the correlation between the photoexcitation pathways and the critical energies required for ablation of poly(methyl methacrylate): A molecular dynamics study

The energetics initiating ablation in poly(methyl methacrylate) (PMMA) are studied using molecular dynamics (MD) simulation. The critical energy to initiate ablation in PMMA following the absorption of photons is investigated for two penetration depths along a range of fluences using a coarse-grained, hybrid Monte Carlo-MD scheme. Both heating and direct bond scission are simulated separately after photon absorption with additional transformation of material occurring via chemical reactions following the photochemical bond cleavage. For a given type of absorption and reaction channel, a critical energy can well describe the amount of energy required to initiate ablation. The simulations show a decrease in the critical energy when a greater amount of photochemistry is introduced in the system. The simulations complement experimental studies and elucidate how enhanced photochemistry lowers ablation thresholds in polymer substrates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absence of amorphous phase in high power femtosecond laser-ablated silicon

As femtosecond lasers emerge as viable tools for advanced microscale materials processing, it becomes increasingly important to understand the characteristics of materials resulting from femtosecond laser microablation or micromachining. We conducted transmission electron microscopy experiments to investigate crater structures in silicon produced by repetitive high power femtosecond laser ablation. Comparable experiments of nanosecond laser ablation of silicon were also performed. We found that an amorphous silicon layer that is typically produced in nanosecond laser ablation is absent when the material is irradiated by high power femtosecond laser pulses. Instead, only a defective single crystalline layer was observed in the high power femtosecond laser-ablated silicon crater. Possible mechanisms underlying the formation of the defective single crystalline phase are discussed.

36 MATERIALS SCIENCE↗

Effect of Current Rise-time on the Formation of Precursor Structures and Mass Ablation Rate in Cylindrical Wire Array Z-Pinches

We present the first study to directly compare the mass ablation rates of cylindrical wire arrays as a function of the current rise-rate. Formation of the precursor column is investigated on both the MAPGIE (1 MA, 250 ns) and COBRA (1 MA, 100 ns) generators, and results are used to infer the change in the mass ablation rate induced by the rise-rate of the drive current. Laser shadowography, gated XUV imaging and x-ray diodes are used to compare the dynamical behavior both generators, and x-pinch radiography and XUV spectroscopy and provide density evolution and temperature measurements respectively. Results are compared to predictions from an analytical scaling model based on a fixed ablation rate, and the close correlation achieved suggests that the effective ablation velocity is not a strong function of the current rise rate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Application of the Wire Ablation Dynamics Model to the Design and Optimization of Wire Array Loads of Complex Geometry

The implosion dynamics of wire array loads of complex geometry, such as nested cylindrical and planar wire arrays, is significantly affected by the uneven current distribution between the array wires, which was considered previously in the Wire Dynamics Model (WDM) simulations. The novel Wire Ablation Dynamics Model (WADM) extends the formalism of the original WDM by including the dynamics of wire ablation. The WADM simulations demonstrate that the implosions of the arrays with higher masses are more ablation dominated. The WADM simulations of the implosions dynamics of nested wire arrays have been performed for the short pulse (100 ns) and long pulse (220 ns) regimes at COBRA generator. Another factor that affects the result of the trade between the ablation and implosion time scales is the form of the current pulse, which can be very different from the classical sine-square shape. The predictions of the array implosion times by the WADM are in very good agreement with the recent experiments at the COBRA and Zebra facilities.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-threshold ablation of dielectrics irradiated by picosecond soft x-ray laser pulses

Ablation of LiF crystal by soft x-ray laser (XRL) pulses with wavelength {lambda}=13.9 nm and duration T{sub L}=7 ps is studied experimentally and theoretically. It is found that a crater appears on a surface of LiF for XRL fluence, exceeding the ablation threshold F{sub a}{approx}10.2 mJ/cm{sup 2} in one shot, or 5 mJ/cm{sup 2} in each of the three XRL shots. This is substantially below the ablation thresholds obtained with other lasers having longer pulse duration and/or longer wavelength. A mechanism of thermomechanical ablation in large bandgap dielectrics is proposed. The theory explains the low F{sub a} via small attenuation depth, absence of light reflection, and electron heat conductivity.

36 MATERIALS SCIENCE↗

The role of magnetic field in the transition to streaming ablation in wire arrays

In wire array Z-pinches, the magnetic field configuration and the global field penetration of individual wires play a key role in the ablation plasma dynamics. Knowledge of the magnetic field configuration is necessary to understand the ablation plasma acceleration process near the wires. Two-dimensional resistive magnetohydrodynamics simulations show that a change in the global magnetic field configuration is critical to initiating inward flow of the ablation plasma. Analysis of these simulations show that the initially compressive JxB force around a wire in its vacuum field configuration undergoes a transition to a configuration in which the Lorentz force can accelerate plasma toward the array axis. This transition is achieved through a low magnetic Reynolds number diffusive flow in which the plasma and the magnetic field are decoupled. The plasma current follows the expanding plasma toward the array axis and, after traveling a critical distance scaling with the array radius divided by the wire number, the global magnetic field threads the wire core, thereby allowing JxB coronal acceleration into ablation streams.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Survey Of CO{sub 2} Laser Ablation Propulsion With Polyoxymethylene Propellant

Polyoxymethylene (POM) has been widely studied as a laser propulsion propellant paired to CO{sub 2} laser radiation. POM is a good test case for studying ablation properties of polymer materials, and within limits, for study of general trends in laser ablation-induced impulse. Despite many studies, there is no general understanding of POM ablation that takes into account the ambient pressure, spot area, fluence, and effects from confinement and combustion. This paper reviews and synthesizes CO{sub 2} laser ablation propulsion research using POM targets. Necessary directions for future study are indicated to address incomplete regions of the various parameter spaces. Literature data is compared in terms of propulsion parameters such as momentum coupling coefficient and specific impulse, within a range of fluences from about 1-500 J/cm{sup 2}, ambient pressures from about 10{sup -2}-10{sup 5} Pa, and laser spot areas from about 0.01-10 cm{sup 2}.

42 ENGINEERING↗

CO{sub 2} Laser Ablation Propulsion Tractor Beams

Manipulation of objects at a distance has already been achieved with no small measure of success in the realm of microscopic objects on the scale size of nanometers to micrometers in applications including laser trapping and laser tweezers. However, there has been relatively little effort to apply such remote control to macroscopic systems. A space tractor beam could be applied to a wide range of applications, including removal of orbital debris, facilitation of spacecraft docking, adjustment of satellite attitude or orbital position, etc. In this paper, an ablative laser propulsion tractor beam is demonstrated based on radiation from a CO{sub 2} laser. Cooperative, layered polymer targets were used for remote impulse generation using a CO{sub 2} laser. The use of a structured ablatant enabling switching between thrust directional parity (i.e., forward or reverse) and imparting torque to a remote target. Fluence-dependent results are presented in the context of polymer ablation modeling work and with consideration of confined ablation effects.

42 ENGINEERING↗

A Review of Laser Ablation Propulsion

Laser Ablation Propulsion is a broad field with a wide range of applications. We review the 30-year history of laser ablation propulsion from the transition from earlier pure photon propulsion concepts of Oberth and Saenger through Kantrowitz's original laser ablation propulsion idea to the development of air-breathing 'Lightcraft' and advanced spacecraft propulsion engines. The polymers POM and GAP have played an important role in experiments and liquid ablation fuels show great promise. Some applications use a laser system which is distant from the propelled object, for example, on another spacecraft, the Earth or a planet. Others use a laser that is part of the spacecraft propulsion system on the spacecraft. Propulsion is produced when an intense laser beam strikes a condensed matter surface and produces a vapor or plasma jet. The advantages of this idea are that exhaust velocity of the propulsion engine covers a broader range than is available from chemistry, that it can be varied to meet the instantaneous demands of the particular mission, and that practical realizations give lower mass and greater simplicity for a payload delivery system. We review the underlying theory, buttressed by extensive experimental data. The primary problem in laser space propulsion theory has been the absence of a way to predict thrust and specific impulse over the transition from the vapor to the plasma regimes. We briefly discuss a method for combining two new vapor regime treatments with plasma regime theory, giving a smooth transition from one regime to the other. We conclude with a section on future directions.

79 ASTRONOMY AND ASTROPHYSICS↗