Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerated qualification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Proposed Junction-Box Stress Test (Using an Added Weight) for Use During the Module Qualification (Presentation)

Engineering robust adhesion of the junction-box (j-box) is a hurdle typically encountered by photovoltaic (PV) module manufacturers during product development. Furthermore, there are historical incidences of adverse effects (e.g., fires) caused when the j-box/adhesive/module system has failed in the field. The addition of a weight to the j-box during the 'damp heat' IEC qualification test isproposed to verify the basic robustness of the j-box adhesion system. The details of the proposed test are described, in addition to the preliminary results conducted using representative materials and components.

14 SOLAR ENERGY↗

International PV QA Task Force's Proposed Comparative Rating System for PV Modules: Preprint

The International PV Quality Assurance Task Force is developing a rating system that provides comparative information about the relative durability of PV modules. Development of accelerated stress tests that can provide such comparative information is seen as a major step toward being able to predict PV module service life. This paper will provide details of the ongoing effort to determine the format of such an overall module rating system. The latest proposal is based on using three distinct climate zones as defined in IEC 60721-2-1 for two different mounting systems. Specific stresses beyond those used in the qualification tests are being developed for each of the selected climate zones.

14 SOLAR ENERGY↗

Space qualification of optical instruments using the NASA Long-Duration Exposure Facility

The NASA Long-Duration Exposure Facility (LDEF), designed for the in situ testing of optical instrumentation in the space environment is described. The LDEF is basically a reusable structure which is three-axis gravity-gradient stabilized when flying free in space. The structure weighs about 8,000 lbs. and accommodates experiment trays weighing about 10,000 lbs. A vacuum exposure control canister is being designed for controlled exposure experiments. The LDEF will have an experiment power and data system and a shuttle bay environmental measurements system is being designed for measuring parameters such as acoustics, vibration, acceleration. The induced environment contamination monitor will evaluate the contamination levels of shuttle payloads. Experiments currently under development include the evaluation of active optical components and the study of fiber optic data transmission.

Clark, L. G.↗

Development and Testing of Molecular Adsorber Coatings

The effect of on-orbit molecular contamination has the potential to degrade the performance of spaceflight hardware and diminish the lifetime of the spacecraft. For example, sensitive surfaces, such as optical surfaces, electronics, detectors, and thermal control surfaces, are vulnerable to the damaging effects of contamination from outgassed materials. The current solution to protect these surfaces is through the use of zeolite coated ceramic adsorber pucks. However, these pucks and its additional complex mounting hardware requirements result in several disadvantages, such as size, weight, and cost related concerns, that impact the spacecraft design and the integration and test schedule. As a result, a new innovative molecular adsorber coating was developed as a sprayable alternative to mitigate the risk of on-orbit molecular contamination. In this study, the formulation for molecular adsorber coatings was optimized using various binders, pigment treatment methods, binder to pigment ratios, thicknesses, and spray application techniques. The formulations that passed coating adhesion and vacuum thermal cycling tests were further tested for its adsorptive capacity. Accelerated molecular capacitance tests were performed in an innovatively designed multi-unit system containing idealized contaminant sources. This novel system significantly increased the productivity of the testing phase for the various formulations that were developed. Work performed during the development and testing phases has demonstrated successful application of molecular adsorber coatings onto metallic substrates, as well as, very promising results for the adhesion performance and the molecular capacitance of the coating. Continued testing will assist in the qualification of molecular adsorber coatings for use on future contamination sensitive spaceflight missions.

Abraham, Nithin↗

Vibration and Acoustic Testing for Mars Micromission Spacecraft

The objective of the Mars Micromission program being managed by the Jet Propulsion Laboratory (JPL) for NASA is to develop a common spacecraft that can carry telecommunications equipment and a variety of science payloads for exploration of Mars. The spacecraft will be capable of carrying robot landers and rovers, cameras, probes, balloons, gliders or aircraft, and telecommunications equipment to Mars at much lower cost than recent NASA Mars missions. The lightweight spacecraft (about 220 Kg mass) will be launched in a cooperative venture with CNES as a TWIN auxiliary payload on the Ariane 5 launch vehicle. Two or more Mars Micromission launches are planned for each Mars launch opportunity, which occur every 26 months. The Mars launch window for the first mission is November 1, 2002 through April 2003, which is planned to be a Mars airplane technology demonstration mission to coincide with the 100 year anniversary of the Kittyhawk flight. Several subsequent launches will create a telecommunications network orbiting Mars, which will provide for continuous communication with lenders and rovers on the Martian surface. Dedicated science payload flights to Mars are slated to start in 2005. This new cheaper and faster approach to Mars exploration calls for innovative approaches to the qualification of the Mars Micromission spacecraft for the Ariane 5 launch vibration and acoustic environments. JPL has in recent years implemented new approaches to spacecraft testing that may be effectively applied to the Mars Micromission. These include 1) force limited vibration testing, 2) combined loads, vibration and modal testing, and 3) direct acoustic testing. JPL has performed nearly 200 force limited vibration tests in the past 9 years; several of the tests were on spacecraft and large instruments, including the Cassini and Deep Space One spacecraft. Force limiting, which measures and limits the spacecraft base reaction force using triaxial force gages sandwiched between the spacecraft and the test fixture, alleviates the severe overtest at spacecraft resonances inherent in rigid fixture vibration tests. It has the distinct advantage over response limiting that the method is not dependent on the accuracy of a detailed dynamic model of the spacecraft. Combined loads, vibration, and modal testing were recently performed on the QuikSCAT spacecraft. The combined tests were performed in a single test setup per axis on a vibration shaker, reducing test time by a factor of two or three. Force gages were employed to measure the true c.g. acceleration of the spacecraft for structural loads verification using a sine burst test, to automatically notch random vibration test input accelerations at spacecraft resonances based on predetermined force limits, and to directly measure modal masses in a base drive modal test. In addition to these combined tests on the shaker, the QuikSCAT spacecraft was subjected to a direct field acoustic test by surrounding the spacecraft, still on the vibration shaker, with rock concert type acoustic speakers. Since the spacecraft contractor does not have a reverberant field acoustic test facility, performing a direct field acoustic test -saved the program nearly two weeks schedule time that would have been required for packing / unpacking and shipping of the spacecraft. This paper discusses the rationale behind and advantages of the above test approaches and provides examples of their actual implementation and comparisons to flight data. The applicability of the test approaches to Mars Micromission spacecraft qualification is discussed.

Kern, Dennis L.↗

Separate effects irradiation testing of miniature fuel specimens

We report that qualification of new nuclear fuels is necessary for their deployment and requires a thorough understanding of fuel behavior under irradiation. Traditionally, nuclear fuels have been qualified by performing exhaustive integral tests under a limited range of prototypic conditions designed for their specific reactor application. While some integral fuel testing is essential, basic data on behavior and property evolution under irradiation can be obtained from separate effects tests. These irradiations could offer reduced cost, reduced complexity, and in the case of accelerated testing, reduced time to achieve a given burnup. Furthermore, it may be desirable to design test irradiations capable of deconvoluting the myriad effects of burnup, temperature gradients, and other factors inherent to integral irradiation tests. Oak Ridge National Laboratory has developed an experimental capability to perform separate effects irradiation testing of miniature fuel specimens in the High Flux Isotope Reactor (HFIR): the “MiniFuel” irradiation vehicle. The small size (<4 mm 3 ) of the fuel specimens simplifies the design, analysis, and post-irradiation examination. By reducing the fuel mass, the total heat generated inside the experiment vehicle can be dominated by gamma heating in the structural materials instead of fission heating in the fuel. This essentially decouples the fuel temperature from the fission rate, allowing for highly accelerated testing (3X-18X the burnup rate of a typical light water reactor for 235 U enrichments varying from 0.22 wt% to 8 wt%) and an extremely flexible experiment design that can accommodate a wide range of fuel temperatures (~100 °C to >1200 °C), compositions, enrichments, and even geometries without requiring detailed analyses for each fuel variant. In conclusion, this paper summarizes the experiment design concept, evaluates potential applications for specific fuel forms, and briefly describes the first set of experiments on uranium nitride kernels that have been assembled and are currently being irradiated in the HFIR.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Additive Manufacturing Moment Measure (AM3) Approach to Predictions of Solid Cooling Rate and Time Above Melt

Qualification of a laser powder bed fusion additive manufacturing (LPBF-AM) process requires knowledge of the multi-scale material physics during the process, per part. As the LPBF-AM build occurs, each moment is influenced by the process history. Knowledge of the build sequence can be used to generate a discretized time-space-condition point field that when coupled with a nearest neighbors’ calculation results in a generalized and fully parallel process model computation. This GPU accelerated approach was developed for part-scale analysis of build files along with in-situ process monitoring sensor data and is termed the “Additive Manufacturing Moment Measure” (AM3). The AM3 approach will be presented and then used to evaluate an AM Bench relevant geometry with synchronized in-situ process data, ex-situ nondestructive evaluation, and optical microscopy observations. These comparisons permit a better understanding of how the process actions can affect the LPBF-AM build quality and the signals generated during in-situ process monitoring.

Additive Manufacturing↗

First Results from two Nb3Sn Cavities Assembled in a CEBAF Quarter Cryomodule

Two 1.5 GHz CEBAF C75-shape 5-cell accelerator cavities were coated with Nb3Sn film using the vapor diffusion technique at Fermilab and Jefferson Labcoating facilities. Both cavities were measured at 4 K and 2 K in the vertical cavity test facility (VCTF) in each lab, then assembled into a CEBAF quartercryomodule at Jefferson Lab. The cryomodule was tested at 4 K and 2 K in the CryoModule Test Facility (CMTF) at Jefferson Lab. RF test results for bothcavities in the cryomodule are similar to those in the qualification test in VTS, with one cavity reaching Eacc =7.9 MV/m and the other - 13.3 MV/m at 4 K

Eremeev, G.↗

LIF Density Measurement Calibration Using a Reference Cell

Flight qualification of ion thrusters typically requires testing on the order of 10,000 hours. Extensive knowledge of wear mechanisms and rates is necessary to establish design confidence prior to long duration tests. Consequently, real-time erosion rate measurements offer the potential both to reduce development costs and to enhance knowledge of the dependency of component wear on operating conditions. Several previous studies have used laser induced fluorescence (LIF) to measure real-time, in situ erosion rates of ion thruster accelerator grids. Those studies provided only relative measurements of the erosion rate. In the present investigation, a molybdenum tube was resistively heated such that the evaporation rate yielded densities within the tube on the order of those expected from accelerator grid erosion. A pulsed UV laser was used to pump the ground state molybdenum at 345.64nm, and the non-resonant fluorescence at 550-nm was collected using a bandpass filter and a photomultiplier tube or intensified CCD array. The sensitivity of the fluorescence was evaluated to determine the limitations of the calibration technique. The suitability of the diagnostic calibration technique was assessed for application to ion engine erosion rate measurements.

Domonkos, Matthew T.↗

Qualification Testing Versus Quantitative Reliability Testing of PV - Gaining Confidence in a Rapidly Changing Technology: Preprint

Continued growth of PV system deployment would be enhanced by quantitative, low-uncertainty predictions of the degradation and failure rates of PV modules and systems. The intended product lifetime (decades) far exceeds the product development cycle (months), limiting our ability to reduce the uncertainty of the predictions for this rapidly changing technology. Yet, business decisions (setting insurance rates, analyzing return on investment, etc.) require quantitative risk assessment. Moving toward more quantitative assessments requires consideration of many factors, including the intended application, consequence of a possible failure, variability in the manufacturing, installation, and operation, as well as uncertainty in the measured acceleration factors, which provide the basis for predictions based on accelerated tests. As the industry matures, it is useful to periodically assess the overall strategy for standards development and prioritization of research to provide a technical basis both for the standards and the analysis related to the application of those. To this end, this paper suggests a tiered approach to creating risk assessments. Recent and planned potential improvements in international standards are also summarized.

14 SOLAR ENERGY↗

Absolute Density Calibration Cell for Laser Induced Fluorescence Erosion Rate Measurements

Flight qualification of ion thrusters typically requires testing on the order of 10,000 hours. Extensive knowledge of wear mechanisms and rates is necessary to establish design confidence prior to long duration tests. Consequently, real-time erosion rate measurements offer the potential both to reduce development costs and to enhance knowledge of the dependency of component wear on operating conditions. Several previous studies have used laser-induced fluorescence (LIF) to measure real-time, in situ erosion rates of ion thruster accelerator grids. Those studies provided only relative measurements of the erosion rate. In the present investigation, a molybdenum tube was resistively heated such that the evaporation rate yielded densities within the tube on the order of those expected from accelerator grid erosion. This work examines the suitability of the density cell as an absolute calibration source for LIF measurements, and the intrinsic error was evaluated.

Domonkos, Matthew T.↗

PEM-INST-001: Instructions for Plastic Encapsulated Microcircuit (PEM) Selection, Screening, and Qualification

Potential users of plastic encapsulated microcircuits (PEMs) need to be reminded that unlike the military system of producing robust high-reliability microcircuits that are designed to perform acceptably in a variety of harsh environments, PEMs are primarily designed for use in benign environments where equipment is easily accessed for repair or replacement. The methods of analysis applied to military products to demonstrate high reliability cannot always be applied to PEMs. This makes it difficult for users to characterize PEMs for two reasons: 1. Due to the major differences in design and construction, the standard test practices used to ensure that military devices are robust and have high reliability often cannot be applied to PEMs that have a smaller operating temperature range and are typically more frail and susceptible to moisture absorption. In contrast, high-reliability military microcircuits usually utilize large, robust, high-temperature packages that are hermetically sealed. 2. Unlike the military high-reliability system, users of PEMs have little visibility into commercial manufacturers proprietary design, materials, die traceability, and production processes and procedures. There is no central authority that monitors PEM commercial product for quality, and there are no controls in place that can be imposed across all commercial manufacturers to provide confidence to high-reliability users that a common acceptable level of quality exists for all PEMs manufacturers. Consequently, there is no guaranteed control over the type of reliability that is built into commercial product, and there is no guarantee that different lots from the same manufacturer are equally acceptable. And regarding application, there is no guarantee that commercial products intended for use in benign environments will provide acceptable performance and reliability in harsh space environments. The qualification and screening processes contained in this document are intended to detect poor-quality lots and screen out early random failures from use in space flight hardware. However, since it cannot be guaranteed that quality was designed and built into PEMs that are appropriate for space applications, users cannot screen in quality that may not exist. It must be understood that due to the variety of materials, processes, and technologies used to design and produce PEMs, this test process may not accelerate and detect all failure mechanisms. While the tests herein will increase user confidence that PEMs with otherwise unknown reliability can be used in space environments, such testing may not guarantee the same level of reliability offered by military microcircuits. PEMs should only be used where due to performance needs there are no alternatives in the military high-reliability market, and projects are willing to accept higher risk.

Teverovsky, Alexander↗

LCLS-II-HE Vertical Acceptance Testing Plans

LCLS-II-HE has performance requirements similar to but generally more demanding than those of LCLS-II, with an operating gradient of 21 MV/m (up from 16 MV/m in LCLS-II) and tighter restrictions on field emission and multipacting. In this paper, we outline the requirements for the 1.3 GHz cavities and the plans for qualification of these cavities by vertical test. We discuss lessons learned from LCLS-II and highlight the changes implemented in the vertical test procedure for the new project.

43 PARTICLE ACCELERATORS↗

First Results from Two Nb3Sn Cavities Assembled in a CEBAF Quarter Cryomodule

Two 1.5 GHz CEBAF C75-shape 5-cell accelerator cavities were coated with Nb3Sn film using the vapor diffusion technique at Fermilab and Jefferson Lab coating facilities. Both cavities were measured at 4 K and 2 K in the vertical cavity test facility (VCTF) in each lab, then assembled into a CEBAF quarter cryomodule at Jefferson Lab. The cryomodule was tested at 4 K and 2 K in the CryoModule Test Facility (CMTF) at Jefferson Lab. RF test results for both cavities in the cryomodule are similar to those in the qualification test in VTS, with one cavity reaching Eacc = 7.9 MV/m and the other - 13.3 MV/m at 4 K.

Eremeev, G.↗

Considerations for a Standardized Test for Potential-Induced Degradation of Crystalline Silicon PV Modules (Presentation)

Over the past decade, there have been observations of module degradation and power loss because of the stress that system voltage bias exerts. This results in part from qualification tests and standards note adequately evaluating for the durability of modules to the long-term effects of high voltage bias that they experience in fielded arrays. This talk deals with factors for consideration,progress, and information still needed for a standardized test for degradation due to system voltage stress.

14 SOLAR ENERGY↗

A Revised Capsule Design for the Accelerated Testing of Advanced Reactor Fuels

Testing of fast reactor fuel is currently challenging because of the thermal neutron spectrum of the Advanced Test Reactor (ATR) and the fact that ATR coolant is substantially below typical temperatures found in liquid metal-cooled fast reactors. Despite these issues, since 2003 the Idaho National Laboratory (INL) has successfully tested a variety of metallic, oxide, and nitride fuels for fast reactor applications. There are, however, opportunities to improve the experiments so that the time required to reach a desired burnup can be reduced, and so the sensitivity of the experiments to fabrication tolerances can be minimized. A revised capsule design exploits the use of smaller diameter rodlets to increase power densities and correspondingly reduce the irradiation time required to reach high burnup. Thermal and nuclear analyses indicate that the time to reach 30at% burnup could be reduced from about 12 years to approximately 2-3 years if the fuel diameter is reduced by one-half and to around 1-2 years if the diameter is reduced by one-third. In addition, reducing fuel diameter improves the radial power distribution in the fuel without the use of cadmium shrouding. This observation opens up the possibility of testing advanced reactor fuel systems in Small I locations in the ATR where there is substantial unused capacity. Although not directly tied to a revised capsule design, post-irradiation furnace testing is proposed to provide time-to-failure data that will be helpful in the benchmarking of fuel performance models and in assessing the performance of new fuel designs relative to more standard fast reactor fuel systems. In this paradigm, ATR irradiation experiments will be viewed more as preparation for furnace testing than as experiments that exist in isolation. An added benefit to furnace testing is that uncertainties in temperatures will significantly be reduced relative to non-instrumented capsules in the ATR. The time and cost in developing this experimental capability is expected to be reduced considerably because of the availability of the blister anneal furnace used by the HPRR program. A key issue in the experiment approach is the potential for non-prototypical rodlet dimensions to influence the observed performance of a given fuel design. For example, a qualitative assessment indicates that the effects of fuel-cladding chemical interactions during furnace testing might be more pronounced in reduced diameter rodlets simply because thinner cladding would be more sensitive to a given depth of fission product penetration. In a traditional empirically-driven approach to fuel qualification, any change from prototypical behavior is undesirable because the resulting data cannot easily be assimilated into a statistical correlation. However, in the current approach, systematic variations in fuel diameter provide the opportunity to benchmark fuel performance models over a wider range of parameter space, which in turn is expected to improve understanding and result in better, more physically based models in the long term.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Challenge to Move from 'One Size Fits All' to PV Modules the Customer Needs: Preprint

Historically, PV companies requested a single qualification test for a single product. As the market has grown, there have been increasing opportunities for companies to differentiate their products while still maintaining high manufacturing volumes of each product. At the same time, as PV is deployed in an increasingly broad range of conditions, modules need to be able to withstand a wide rangeof stresses. In some cases, targeting a specific deployment condition may allow reduction of product cost. Realizing this opportunity will require the ability to confidently predict long-term performance based on accelerated tests and known weather conditions. By working together, the community can most quickly develop tests that identify which products perform well under which conditions. Thispaper discusses some of the challenges of predicting long-term PV performance, including the wide range of stresses that may be encountered, the variability of the stresses from moment to moment, the complexity of some degradation mechanisms, and the dependence of accelerated testing on module geometry. The paper also describes two international projects that deal with location-specificdurability evaluation and long-term module performance.

14 SOLAR ENERGY↗

Data-Driven Optimization of the Processing Window for 316H Components Fabricated Using Laser Powder Bed Fusion

The Advanced Materials and Manufacturing Technologies Program is focused on accelerating the development and deployment of advanced materials and components fabricated via additive manufacturing with a specific focus on laser powder bed fusion (LPBF). As an initial case study, the program has selected 316H stainless steel (SS) as an initial material around which to develop a code case development strategy. This strategy involves two parallel approaches: (1) an equivalency approach whereby round-robin testing across multiple collaborating laboratories demonstrates repeatability in processing and direct comparisons with conventional wrought 316H material and (2) a revolutionary approach to code qualification combining in situ data collection and high-fidelity modeling to capture, predict, and bound the performance of LPBF 316HSS components. As part of this campaign, this work package has initiated an extensive process optimization campaign across three laboratories, each printing variations of LPBF 316HSS using three different LPBF units (Concept Laser, EOS, and Renishaw). In FY23, ORNL has focused on unique experimental designs spanning wide ranges in energy inputs and turning knobs such as scan speed, laser power, hatch spacing, layer thickness, spot size, scan rotation, and more. On the Concept Laser M2, 72 different combinations of processing variables were investigated with duplicate samples and different powder compositions. In total, 252 samples were printed with combined in situ sensing data. A parallel design of experiments was conducted on the Renishaw AM400 with an additional 390 printed specimens for analysis. All 642 miniature specimens, each with unique features included in each print to capture geometry-related heterogeneity, were subjected to high-throughput x-ray computed tomography (XCT) analysis to enable the downselection of specific processing parameters of interest. Then, using electrical discharge machining (EDM), miniature tensile specimens were extracted for mechanical testing and microscopy investigations. From the analysis performed in FY23, it was found that powder composition drastically affects the resulting microstructure and mechanical performance of 316SS. Specifically, changing from 316L to 316HSS powder results in a wide range of grain sizes with varying degrees of preferred grain orientation, which increases as a function of energy density. It was also found that due to stored heat in thin fin–type features, large microstructural differences can be seen within one part printed with one set of processing parameters. These variations in microstructure features, including grain size, the nanoscale dislocation structure, and grain texture, will all affect the irradiation performance and high-temperature mechanical performance of LPBF 316HSS parts. Two sets of concept laser processing parameters, spanning both refined and columnar grain structures, were scaled to print larger 316H builds for campaign testing (high-temperature creep and irradiation). In addition, at least two optimized processing parameter sets were identified for the Renishaw AM400 for round-robin testing in FY24 with Argonne National Laboratory. Future work includes printing samples using identical parameters identified by partner institutions, providing material for corrosion and high-temperature mechanical testing, and continuing evaluations of heterogeneity in larger printed parts.

36 MATERIALS SCIENCE↗