At least 379 records · Page 21

A Station Tethered Express Payload System (STEPS)

Most capsules designed to return payloads from earth orbit use rockets for deorbit. They have modest payload mass & volume fractions. Active attitude control raises costs, and the deorbit rocket imposes risks which increase development and operational costs. This note describes an alternative concept now being developed under NASA funding. It uses a tether to both deorbit and orient the capsule. This allows simultaneous reduction of capsule complexity, cost, loads, hazards, and reentry errors. The flight of SEDS-1 in 1993 proved out the basic concepts. A 20 km tether slung a 26 kg payload back to earth from a 74O x 19O km orbit, accurately enough for a pre-positioned observer to videotape the reentry. As air drag built up just before reentry, the tether was blown back and became a kite-tail, with tension increasing as predicted before flight. The tether was still attached at approx. 110 km, when telemetry was lost.

Carroll, Joseph A.↗

Electrophoretic Deposition for Fabricating Microbatteries

An improved method of fabrication of cathodes of microbatteries is based on electrophoretic deposition. Heretofore, sputtering (for deposition) and the use of photoresist and liftoff (for patterning) have been the primary methods of fabricating components of microbatteries. The volume of active electrode material that can be deposited by sputtering is limited, and the discharge capacities of prior microbatteries have been limited accordingly. In addition, sputter deposition is slow. In contrast, electrophoretic deposition is much faster and has shown promise for increasing discharge capacities by a factor of 10, relative to those of microbatteries fabricated by prior methods.

West, William↗

Freeze Casting of LAGP for 3D Textured Solid-State Structural Electrolytes

In this study, all-solid-state structural lithium-ion batteries, a type of load bearing electrochemical energy storage that provides systems-level weight savings is being pursued for the realization of inherently safe next generation hybrid-electric and all-electric green aerospace propulsion systems. Currently investigated all-solid-state batteries do not meet the requirements for specific power and mechanical stability. To address these issues, freeze casting of lithium aluminum germanium phosphate (LAGP) electrolyte material has been explored for the creation of a textured 3D electrolyte scaffold with large interfacial surface area for high power discharge and hierarchical porosity for accommodation of active material volume changes during electrochemical cycling. We report the effects of freeze casting processing parameters on the microstructural development and mechanical performance of the scaffolds, characterized through scanning electron microscopy and ring-on-ring mechanical testing. Slurry composition and casting parameters such as solids loading, casting speed, tape angle, and temperature gradients have been modified to determine the impact on density, lamellar morphology, and final load-bearing performance.

ceramics↗

TN{sup R} MW- Multi Waste Package 'All In One Solution' For Conditioning - Transport - Storage - Up To Final Disposal - 17196

For the management of radioactive waste, either during nuclear facility operation or decommissioning, one must consider a diverse array of nuclear waste forms of various types, volumes and activities. Examples are: activated metallic waste; legacy waste; sludge; resins; and orphan waste. Customers are frequently faced with the obligation of undertaking multiple, costly waste management operations. These operations activities include handling, reconditioning or material transfers between packages, as in the case when moving material from on-site storage to transportation, and then from transportation to final disposal. To address this issue, a new - highly flexible up to reversible - cask system, the TN{sup R} MW, is being developed as an 'All in One Solution'. TN{sup R} MW has a total weight of 10 metric tons and is compliant with the 2012 International Atomic Energy Agency (IAEA) regulations. It was developed to provide flexibility and designed with the capability to be adaptable to the various needs of the nuclear industry. From IP-2 and Type A containers to Type B(U) and B(U)F casks, this cask offers different options to sufficiently address the requirements of each step of the waste stream from on-site and international transport to long-term interim storage and final disposal. Licensing and manufacturing of a number of packagings in this TN{sup R} MW family are underway. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

EPRI Software for Estimating Decommissioning Waste Volumes - 16046

EPRI has adapted computer software that can estimate the volume and activity content of waste resulting from the dismantlement of nuclear facilities. This software, designated as Automatic Estimation of the Radiological Inventory or AERI, was originally developed by Iberdrola for use by ENRESA in Spain. The software estimates the radiological inventory for all the components and civil structures of the plant or other facility that are included in the physical inventory. The radiological inventory shows the internal and external surface contamination, as well as the volumetric contamination. The processes of the software are able to estimate both the specific activity levels (in Bq/g or pCi/g) for each radionuclide and the surface activity (Bq/cm{sup 2} or dpm/100 cm{sup 2}) for components and civil structures located in the radiological areas. AERI allows the user to extrapolate, through a statistical approach, the contamination levels obtained by sampling data in specific components and civil structures to the entire facility. The main benefits and values obtained with AERI are the following: - The radiological inventory of the plant can be obtained from a limited set of radiological sampling data. Using the mathematical models allows for the optimization of the number of sampling and analysis that needs to be done. The uncertainties of the calculations are reduced with more data. The user must balance the level of uncertainty of the calculations and the number of sample data they will use. - The automatic management of radiological data in short computing times allows for the execution of several scenarios in a reasonable time. Therefore, different radioactive waste and decommissioning hypotheses can be tested. For example, inventory and data can be split into two different set. One of them can be used for obtaining radiological inventory for early dismantling (3 years, as example) and the second one for deferred dismantling (25 years.) - The software supports the planning and implementation of decommissioning strategies for nuclear plants. For instance, several decontamination factors can be evaluated, assuming different level for decontamination of materials, and results for materials from several streams and use of different container types may be included in each evaluation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The New TN{sup R} MW Cask System Focused on Facilities End-of-Life Waste Management - 16627

When preparing for the decommissioning of a nuclear facility, during its 'end of life' management and while performing the actual dismantling operations, one has to consider a large diversity of nuclear waste in term of types, volumes and activities. Customers are frequently faced with the obligation to undertake multiple and costly waste management operations including handling, reconditioning or re-transferring from one package to another, for example when moving from on-site storage to transportation. To address this issue, a new - highly flexible - cask system named TN{sup R} MW is being developed. This cask has a total weight of 10 T and is compliant with the 2012 IAEA regulations. It is developed on a flexible concept basis, adaptable to the various nuclear needs, including: from IP2 to B(U) / B(U)F; onsite/ international transportation; long term interim storage. Licensing and manufacturing of number of items of this TN{sup R} MW family is underway. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Shuttle active thermal control system development testing. Volume 1: Overall summary

A summary is given of a series of thermal vacuum tests designed to support the development of the orbiter active thermal control system (ATCS) and included testing of a wide heat load range modular radiator system (MRS) configured to the March 1973 orbiter baseline system, a candidate weight reducing radiator/water cooling system, and a smaller radiator system with a high performance radiator coating. The tests verified the performance of the baseline system and obtained detailed design information for application of a wide heat load range modular radiator system to the orbiter. The two candidate ATCS weight reducing designs have undergone extensive concept verification testing and their system operating characteristics have been determined in sufficient detail for application to the orbiter. Design information has been obtained for an integrated radiator/water cooling system that provides for vehicle heat rejection as well as water management of the excess fuel cell water. Processing techniques have been developed and verified for the application of a high performance thermal control coating to large radiator areas subjected to a temperature range of -280 F to +160 F.

Howell, H. R.↗

Changes in blood volume and response to vaso-active drugs in horizontally casted primates

Experiments were performed on horizontally casted primates (male rhesus monkeys) in order to note changes in blood volume caused by horizontal restraint, to compare orthostatic tolerance before and after casting using the responses to upright tilting, to begin to uncover the cardiovascular and neural mechanisms involved in deconditioning, and to compare the data with that obtained from bed-rested human subjects and from humans exposed to weightlessness. Bolus injections of norepinephrine of 2.0 microgram/kg, phenylephrine of 4.0 microgram/kg, and nitroprusside of 2.0 microgram/kg were administered; and aortic pressure and heart rate were recorded during the injections. The results indicate that the horizontally casted primate is a valid animal model for studying the effects of simulated zero-G on the human cardiovascular system.

Dickey, D. T.↗

Data processing and display of laser Doppler experimental results, volume 1

Contract activities performed in developing a laser Doppler system for detecting, tracking, and measuring aircraft wake vortices are summarized. The computer program for processing and displaying the Dust Devil experimental data is presented. Program listings are included in the appendix.

Ashmore, B. R.↗

Mod-1 wind turbine generator analysis and design report, volume 1

The activities leading to the completion of detail design of the MOD-1 wind turbine generator are described. Emphasis is placed on the description of the design as it finally evolved. However, the steps through which the design progressed are also traced in order to understand the major design decisions.

Source record↗

Semi-solid electrodes having high rate capability

Embodiments described herein relate generally to electrochemical cells having high rate capability, and more particularly to devices, systems and methods of producing high capacity and high rate capability batteries having relatively thick semi-solid electrodes. In some embodiments, an electrochemical cell includes an anode and a semi-solid cathode. The semi-solid cathode includes a suspension of an active material of about 35% to about 75% by volume of an active material and about 0.5% to about 8% by volume of a conductive material in a non-aqueous liquid electrolyte. An ion-permeable membrane is disposed between the anode and the semi-solid cathode. The semi-solid cathode has a thickness of about 250 .mu.m to about 2,000 .mu.m, and the electrochemical cell has an area specific capacity of at least about 7 mAh/cm.sup.2 at a C-rate of C/4. In some embodiments, the semi-solid cathode slurry has a mixing index of at least about 0.9.

25 ENERGY STORAGE↗

Semi-solid electrodes having high rate capability

Embodiments described herein relate generally to electrochemical cells having high rate capability, and more particularly to devices, systems and methods of producing high capacity and high rate capability batteries having relatively thick semi-solid electrodes. In some embodiments, an electrochemical cell includes an anode and a semi-solid cathode. The semi-solid cathode includes a suspension of an active material of about 35% to about 75% by volume of an active material and about 0.5% to about 8% by volume of a conductive material in a non-aqueous liquid electrolyte. An ion-permeable membrane is disposed between the anode and the semi-solid cathode. The semi-solid cathode has a thickness of about 250 .mu.m to about 2,000 .mu.m, and the electrochemical cell has an area specific capacity of at least about 7 mAh/cm.sup.2 at a C-rate of C/4. In some embodiments, the semi-solid cathode slurry has a mixing index of at least about 0.9.

36 MATERIALS SCIENCE↗

Semi-solid electrodes having high rate capability

Embodiments described herein relate generally to electrochemical cells having high rate capability, and more particularly to devices, systems and methods of producing high capacity and high rate capability batteries having relatively thick semi-solid electrodes. In some embodiments, an electrochemical cell includes an anode and a semi-solid cathode. The semi-solid cathode includes a suspension of an active material of about 35% to about 75% by volume of an active material and about 0.5% to about 8% by volume of a conductive material in a non-aqueous liquid electrolyte. An ion-permeable membrane is disposed between the anode and the semi-solid cathode. The semi-solid cathode has a thickness of about 250 μm to about 2,000 μm, and the electrochemical cell has an area specific capacity of at least about 7 mAh/cm2 at a C-rate of C/4. In some embodiments, the semi-solid cathode slurry has a mixing index of at least about 0.9.

25 ENERGY STORAGE↗

Semi-solid electrodes having high rate capability

Embodiments described herein relate generally to electrochemical cells having high rate capability, and more particularly to devices, systems and methods of producing high capacity and high rate capability batteries having relatively thick semi-solid electrodes. In some embodiments, an electrochemical cell includes an anode and a semi-solid cathode. The semi-solid cathode includes a suspension of an active material of about 35% to about 75% by volume of an active material and about 0.5% to about 8% by volume of a conductive material in a non-aqueous liquid electrolyte. An ion-permeable membrane is disposed between the anode and the semi-solid cathode. The semi-solid cathode has a thickness of about 250 μm to about 2,000 μm, and the electrochemical cell has an area specific capacity of at least about 7 mAh/cm2 at a C-rate of C/4. In some embodiments, the semi-solid cathode slurry has a mixing index of at least about 0.9.

Chiang, Yet-Ming↗

Semi-solid electrodes having high rate capability

Embodiments described herein relate generally to electrochemical cells having high rate capability, and more particularly to devices, systems and methods of producing high capacity and high rate capability batteries having relatively thick semi-solid electrodes. In some embodiments, an electrochemical cells includes an anode and a semi-solid cathode. The semi-solid cathode includes a suspension of an active material of about 35% to about 75% by volume of an active material and about 0.5% to about 8% by volume of a conductive material in a non-aqueous liquid electrolyte. An ion-permeable membrane is disposed between the anode and the semi-solid cathode. The semi-solid cathode has a thickness of about 250 μm to about 2,000 μm, and the electrochemical cell has an area specific capacity of at least about 7 mAh/cm 2 at a C-rate of C/4. In some embodiments, the semi-solid cathode slurry has a mixing index of at least about 0.9.

Chiang, Yet-Ming↗

Accelerated development and flight evaluation of active controls concepts for subsonic transport aircraft. Volume 2: AFT C.G. simulation and analysis

Relaxed static stability and stability augmentation with active controls were investigated for subsonic transport aircraft. Analytical and simulator evaluations were done using a contemporary wide body transport as a baseline. Criteria for augmentation system performance and unaugmented flying qualities were evaluated. Augmentation control laws were defined based on selected frequency response and time history criteria. Flying qualities evaluations were conducted by pilots using a moving base simulator with a transport cab. Static margin and air turbulence intensity were varied in test with and without augmentation. Suitability of a simple pitch control law was verified at neutral static margin in cruise and landing flight tasks. Neutral stability was found to be marginally acceptable in heavy turbulence in both cruise and landing conditions.

Urie, D. M.↗

Semi-solid electrodes with gel polymer additive

Embodiments described herein relate generally to electrochemical cells having semi-solid electrodes that include a gel polymer additive such that the electrodes demonstrate longer cycle life while significantly retaining the electronic performance of the electrodes and the electrochemical cells formed therefrom. In some embodiments, a semi-solid electrode can include about 20% to about 75% by volume of an active material, about 0.5% to about 25% by volume of a conductive material, and about 20% to about 70% by volume of an electrolyte. The electrolyte further includes about 0.01% to about 1.5% by weight of a polymer additive. In some embodiments, the electrolyte can include about 0.1% to about 0.7% of the polymer additive.

25 ENERGY STORAGE↗