At least 379 records · Page 21

Virtual Metering for Monitoring Building Energy Consumption

The United States Department of Energy (DOE) has standard metering requirements of commercial buildings for optimizing energy performance. The guiding principles are to continuously track and optimize energy performance and install building-level meters for electricity, natural gas, and steam. Some buildings at Los Alamos National Laboratory (LANL) have physical submeters monitoring their energy consumption, but these meters have proven to be unreliable. And, in most cases, replacing them has proven to be a slow process. Installing new submeters also requires a temporary lockout of the circuit on which they are being installed. Many buildings at LANL contain laboratories with ongoing experiments or data centers, which makes an equipment power outage nearly impossible to plan. This inability to plan power outages results in long-term submeter failures. Although most submeters are eventually replaced, failures lead to missing consumption data for some unpredictable, extended time. A building automation system (BAS) is a system that provides control and monitoring on a building to maintain the operational performance of the building and occupancy comfort. Many buildings at LANL currently have a BAS, and all new renovations and installs will include installing a BAS if one does not already exist. The intended purpose for a BAS is primarily to monitor the health and efficiency of a building; however, it is also possible to calculate equipment power and energy consumption using BAS information. This project aims to use virtual meters to monitor building energy consumption as a cost-effective and minimally labor-intensive alternative to installing physical submeters. The fault detection and diagnostics tool, SkySpark, provides a centralized database for all the data from the various BAS that are active at LANL. This data includes the information that is needed to create virtual meters for heating, ventilating, and air conditioning (HVAC) systems in most buildings, including heating and cooling loads. 9 This report begins with a detailed summary of the project, including the reasoning, procedure, and results. The specific processes of creating the various virtual meters are then identified. Then the limitations are discussed. And, lastly, the results and future potential are presented.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Biochar-compost-based controlled-release nitrogen fertilizer intended for an active microbial community

Nitrogen (N) fertilizers in agriculture suffer losses by volatilization of N to the air, surface runoff and leaching into the soil, resulting in low N use efficiency (NUE) (< 50%) and raising severe environmental pollutions. Controlled- release nitrogen fertilizers (CRNFs) can control the release of N nutrients to NUE in crop production. Different methods were used to develop new CRNFs. However, different CRNF technologies are still underdeveloped due to inadequate controlling on N releasing time and/or unsustainable diffusion. The study on the influences of CRNF processing parameters on microbial conditions are lacking when the CRNFs composed of various bio-ingredients such as biochar, composts, and biowaste. The complexity of processing methods, material biodegradability, and other physical properties make current CRNFs of questionable value in agricultural production. This research aims to develop a novel biochar-compost-based controlled-release urea fertilizer (BCRUF) to preserve microbial properties carried by the compost. The BCRUF was synthesized by pelletizing the 50:50 (dry, wt/wt) mixture of biochar and compost. BCRUF was loaded with urea and then spray-coated with polylactic acid (PLA). The releasing time of two types of BCRUFs, coated and uncoated with PLA, for 80% of N release in water was up to 6 h at three different temperatures (4, 23, and 40 °C), compared to conventional urea fertilizer and commercial environmentally smart N (ESN) fertilizer. The releasing time of coated BCRUF for 80% N release in soil was up to 192 h (8 days). Fourier-transform infrared spectroscopy (FTIR) analysis revealed that no new functional groups were found in the release solution, indicating no new chemical hazards generated. The differential scanning calorimetry (DSC) tests also verified that its thermal stability could be up to 160 °C. The microbe populations in the BCRUF pellets were reduced after the pelleting and drying processes in BCRUF fabrication, but a few bacteria can endure in the air-drying process. BCRUF pellets soaked in water for 4 days retained some bacteria. The BCRUF showed very promising characteristics to improve NUE and sustainability in agricultural production.

58 GEOSCIENCES↗

In situ monitoring of dislocation, twinning, and detwinning modes in an extruded magnesium alloy under cyclic loading conditions

This work investigates the microscopic deformation mechanisms of an extruded, precipitation-strengthened AZ80 magnesium (Mg) alloy subjected to strain-controlled low-cycle fatigue using in situ neutron diffraction measurements. Results demonstrate that the plastic deformation during cyclic loading is dominated by the alternating {10.2} extension twinning and detwinning mechanisms. The observed deformation mode is strongly texture and precipitate dependent. For the initial texture, the tested material has two major texture components which result in the occurrence of extension twinning during both compression and reverse tension in the first two cycles. The prolonged detwinning process in the following cycles is proposed to relieve the shear stress field of {00.2} grains, leading to the disappearance of twinning. The precipitation strengthening results in an increase of the critical resolved shear stress (CRSS) by similar to 33 MPa for the extension twinning in this AZ80 alloy. Here, the synergistic effects of the initial texture, precipitation strengthening, and load sharing of various grain families and phases contribute to the complicated evolution of dominant deformation mechanisms, among which elevated dislocation activities are believed to be responsible for the relatively poor low-cycle-fatigue lifetime when compared to other Mg alloys.

36 MATERIALS SCIENCE↗

Characterizing Plug Load Energy Use and Savings Potential in Army Buildings

The Assistant Secretary of the Army (Installations, Energy and Environment) tasked the Pacific Northwest National Laboratory to examine plug loads in typical Army buildings. Plug loads (also known as miscellaneous electric loads (MELs)) represent the electricity used by appliances and devices that are plugged in or hardwired and serve functions outside of a building’s core end uses. Common plug loads include computers, printers, copiers, networking devices, refrigerators, and vending machines. They also include personal electronic devices such as televisions, smart phones, tablets, and gaming systems. Examples of hardwired MELs include elevators, air compressors, and fire and security systems. The findings from this study confirm that significant energy is consumed within Army buildings by plug load devices and hardwired MEL equipment. A number of opportunities are identified for reducing unnecessary energy use that could save the Army over $5 million per year when broadly applied. Army regulations clearly spell out expectations for the purchase and operation of information technology equipment (computers, laptops, monitors, printers, and multi-function devices). However, the policies regarding the shutdown or activation of sleep and other lower power modes after 30 minutes of inactivity (15 minutes for monitors) do not appear to be consistently followed. There are many effective approaches and pathways for impacting change as it relates to improving awareness, implementing measures, and adjusting behaviors to identify and reduce plug load energy use. The Army should prioritize and consider deploying all of these to better understand and manage plug load equipment to save energy and enhance resilience across their facilities. Engaging the building occupants who use these devices daily via outreach and education should be a strong component of the strategy. The focus should be on reducing waste without sacrificing productivity or the benefits that many of these devices provide. Continued evaluation of plug loads beyond that performed here is important to gather lessons from additional building and equipment types, and to stay aware of evolving device technology and management options. This will highlight additional needs for policies, best practices, control technologies, and education of personnel to achieve real reductions in energy waste from plug load equipment. It is recommended that this study may serve as the foundation for a broader and sustained focus on plug loads and MELs, towards simultaneously enhancing the productivity, readiness, and resilience of the Army while reducing energy use and demand, and freeing up resources to better support the mission.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Tuning acidity in silica-overcoated oxides for hydroalkoxylation

Mixed oxides are ubiquitious solid acid catalysts for a number of transformations. Here, the chemistry of mixed oxide interfaces was experimentally probed by constructing model SiO 2 on MO x interfaces using a liquid-phase, stoichiometrically-controlled deposition of tetraethyl orthosilicate (TEOS). Catalytically active Brønsted sites were generated in four series of overcoated SiO 2 on metal oxide materials prepared by depositing TEOS onto Al 2 O 3 , anatase TiO 2 , Nb 2 O 5 , and ZrO 2 . Pyridine DRIFTS studies indicate that the acidity of deposited silanol groups was enhanced by interaction with the metal oxide surface, suggesting that pseudo-bridging silanol type structures were formed. Trimethylphosphine oxide (TMPO) 31 P NMR experiments showed that Brønsted acid strength varied in the overcoated materials, with increasing strength in the following order: SiO 2 /ZrO 2 < SiO 2 /TiO 2 < SiO 2 /Nb 2 O 5 < SiO 2 /Al 2 O 3 . This order correlated with the Lewis acidity and chemical hardness of the underlying metal oxides. The catalytic performance of the materials was evaluated in the liquid-phase hydroalkoxylation of dihydropyran with n-octanol, revealing that activity was highly dependent on SiO 2 loading, which impacted the density of acid sites, and scaled exponentially with Brønsted acid strength, determined by the core metal oxide identity. Brønsted acid strength appears to be the key driver of the materials’ activity, with the highest areal rate of 2.2 mmol / m 2 – h being measured over SiO 2 /Al 2 O 3 . Furthermore, this study shows that SiO 2 -overcoated materials are a systematically tunable class of catalysts that can be applied to acid catalyzed reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Membrane‐electrode assembly design parameters for optimal CO 2 reduction

Commercial-scale generation of carbon-containing chemicals and fuels by means of electrochemical CO 2 reduction (CO 2 R) requires electrolyzers operating at high current densities and product selectivities. Membrane-electrode assemblies (MEAs) have been shown to be suitable for this purpose. In such devices, the cathode catalyst layer controls both the rate of CO 2 R and the distribution of products. In this study, we investigate how the ionomer-to-catalyst ratio (I:Cat), catalyst loading, and catalyst-layer thickness influence the performance of a cathode catalyst layer containing Ag nanoparticles supported on carbon. In this paper, we explore how these parameters affect the cell performance and establish the role of the exchange solution (water vs. CsHCO 3 ) behind the anode catalyst layer in cell performance. We show that a high total current density is best achieved using an I:Cat ratio of 3 at a Ag loading of 0.01–0.1 mg Ag /cm 2 and with a 1.0 M solution of CsHCO 3 circulated behind the anode catalyst layer. For these conditions, the optimal CO partial current density depends on the voltage applied to the MEA. The work also reveals that the performance of the cathode catalyst layer is limited by a combination of the electrochemically active surface area and the degree to which mass transfer of CO 2 to the surface of the Ag nanoparticles and the transport of OH – anions away from it limit the overall catalyst activity. Hydration of the ionomer in the cathode catalyst layer is found not to be an issue when using an exchange solution. The insights gained allowed for a Ag CO 2 R MEA that operates between 200 mA/cm 2 and 1 A/cm 2 with CO faradaic efficiencies of 78–91%, and the findings and understanding gained herein should be applicable to a broad range of CO 2 R MEA-based devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a water source heat pump hardware-in-the-loop (HIL) testing facility for smart building applications

Over the last decade, the global fight against climate change through electrification has led to an increase in research on building heating, ventilation, and air conditioning (HVAC) systems that utilize intelligent control algorithms to provide demand-side grid service while maintaining the thermal comfort of building occupants. As the pivotalpoint between building electricity consumption and indoor thermal comfort, high-efficiency electrical heatpumps are at the center of these emerging studies, and various grid-interactive and occupant-comfort control algorithms have been developed for them. The impact of these algorithms on the heatpump operation andperformance under different weather, building load, and grid requests calls for investigation and verification via experimental tests with actual heat pumps integrated with real-time building and grid responses. This study presents a Water-Source Heat Pump Hardware-in-The-Loop (HIL) Test Facility developed with the capability to perform such tests. The hardware configuration for this testfacility introduces a hydronic system that emulates the conditions for the heat pump water-side, and a duct system that emulates conditions for the heat pump airside. Both data acquisition and emulator control are implemented through the National Instruments (NI) LabVIEW software running on an NI PXIplatform. The HIL mechanism based on the hardware-software integration that allows the testbed to communicate with a generic simulation environment is also discussed. Currently, the test facility setup includes a single heatpump and virtual building model in EnergyPlus coupled with an occupant behavioral model in MATLAB. Preliminary test results of the current setup demonstrate the building load emulator's ability to track the simulated gone temperature with a Root Mean Square Deviation (RSME) below 0.12°C (0.216°F). An uncertainty analysis based on sensor accuracies shows that the heat pump coefficient of performance (COP) can be measured with a relative uncertainty of 10.4% in cooling and 3.7% in heating. Apartfrom the current testing on a single heat pump, the test facility also provides the flexibility to include additional heat pumps to form a heat pump cluster, as well as coupling the heat pump with active thermal storage to provide enhanced demandflexibility.

Calfa, Caleb↗

A hybrid architecture for volt-var control in active distribution grids

Modern active distribution grids are characterized by the increasing penetration of distributed energy resources (DERs). The proper coordination and scheduling of a large numbers of these small-scale and spatially distributed DERs is necessary, and warrants the use of novel distributed approaches. In this paper, we propose a hybrid volt-var control architecture for the distribution grid, which leverages existing centralized and local approaches to planning, decision making, and control, and augments it with distributed optimization and distributed control for DER management. First, we propose a convex model to describe the power physics of distribution grids of meshed topology and unbalanced structure, based on current injection and McCormick Envelopes. Second, we employ the distributed proximal atomic coordination (PAC) algorithm to coordinate DERs to provide voltage support. We implement volt-var optimization by optimally coordinating DERs including PV smart inverters and demand response. We present results using the IEEE-34 bus network, using real data from a distribution feeder in Hawaii, to model load and PV generation. Different levels of DER penetration and objective functions are simulated. Finally, our results show the need for the coordination of DERs to improve voltage profiles, even in networks with existing voltage control devices. Further, we show the need for flexible reactive power capabilities to achieve desired grid performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Reaction chemistry of ethanol oligomerization to distillate-range molecules using low loading Cu/Mg x AlO y catalysts

We study ethanol oligomerization to higher alcohols and other oxygenates with a 0.3 wt. %Cu/Mg 2.9 AlO catalyst. This reaction involves more than 130 products in a complicated reaction network. The selectivity towards diesel fuel precursor compounds (hereafter ‘DFPC’) increased with conversion until reaching a plateau at an ethanol conversion of ~70 %. Alcohol selectivity was found to follow Schultz-Flory distribution at all studied conversions. Larger sized alcohols then are formed mostly by chain-growth mechanisms via surface reactions of adsorbed oligomers with ethanol-based monomers. Higher esters are formed from alcohols and aldehydes in a series reaction mechanism. Moreover, C 6+ ester and C 4+ ketones selectivities increase as conversion increases. We also found that C 4+ alcohols most likely undergo Guerbet coupling with the studied catalyst to form even higher alcohols once, and that the oxygen of these alcohols is active as a nucleophile, resulting in the selective formation of esters if the starting alcohol is branched. Finally, we performed several cofeed studies varying ethanol-to-H 2 inlet partial pressures, and adding acetaldehyde and ethyl acetate as cofeeds to ethanol at different concentrations. Here, we conclude from these experiments that acetaldehyde concentration controls reaction chemistry, with conditions favoring larger concentrations of the molecule promoting both alcohol coupling and ester formation, and conditions leading to lower concentrations of acetaldehyde resulting in higher alcohol selectivity at the expense of esters and higher aldehydes.

10 SYNTHETIC FUELS↗

Mechanism-Informed Breakdown: Understanding Degradation by Controlling Voltage-Hold Patterns in Proton Exchange Membrane Water Electrolyzers

Low catalyst loadings pose challenges to performance stability in proton exchange membrane (PEM) water electrolysis over extended operation. To study the impact of degradation mechanisms and voltage loss rates, different stress tests are applied to membrane electrode assemblies. Potential cycling conditions were observed to induce higher degrees of iridium (Ir) oxide crystallization, ionomer degradation, and catalyst layer (CL) thinning, which likely contributed to higher kinetic loss rates. On the other hand, while Ir migrating into the PEM (Ir band) generally impairs performance, the interconnected and more uniform Ir band formed under a constant 2 V hold may allow for Ir at the catalyst/membrane interface to remain electronically connected and kinetically accessible, as well as indicate greater Ir site access during the applied stressor. The 2 V hold also demonstrates improved kinetic durability through a lower Tafel slope, faster polarization kinetics, and reduced charge transfer resistance. In contrast, potential cycling caused the migration of disconnected Ir agglomerates into the membrane bulk and created a steady increase in charge transfer resistance, a more dramatic decrease in capacitance (46.7% loss), and significant damage to the surrounding ionomer, indicating a decline in both the quality and quantity of active sites in the anode CL. This work underscores the distinct degradation pathways associated with load holds versus cycling, highlighting the role of catalyst-ionomer interactions in kinetic performance and long-term stability. These insights can inform operational strategies for PEM electrolyzers powered by intermittent energy sources, aiming to minimize efficiency losses over extended operation.

36 MATERIALS SCIENCE↗

Safe and Private Forward-trading Platform for Transactive Microgrids

Power grids are evolving at an unprecedented pace due to the rapid growth of distributed energy resources (DER) in communities. These resources are very different from traditional power sources, as they are located closer to loads and thus can significantly reduce transmission losses and carbon emissions. However, their intermittent and variable nature often results in spikes in the overall demand on distribution system operators (DSO). To manage these challenges, there has been a surge of interest in building decentralized control schemes, where a pool of DERs combined with energy storage devices can exchange energy locally to smooth fluctuations in net demand. Building a decentralized market for transactive microgrids is challenging, because even though a decentralized system provides resilience, it also must satisfy requirements such as privacy, efficiency, safety, and security, which are often in conflict with each other. As such, existing implementations of decentralized markets often focus on resilience and safety but compromise on privacy. In this article, we describe our platform, called TRANSAX, which enables participants to trade in an energy futures market, which improves efficiency by finding feasible matches for energy trades, enabling DSOs to plan their energy needs better. TRANSAX provides privacy to participants by anonymizing their trading activity using a distributed mixing service, while also enforcing constraints that limit trading activity based on safety requirements, such as keeping planned energy flow below line capacity. We show that TRANSAX can satisfy the seemingly conflicting requirements of efficiency, safety, and privacy. We also provide an analysis of how much trading efficiency is lost. Trading efficiency is improved through the problem formulation, which accounts for temporal flexibility, and system efficiency is improved using a hybrid-solver architecture. Lastly, we describe a testbed to run experiments and demonstrate its performance using simulation results.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

MHD-induced SOL filaments and divertor heat flux striations in NSTX

Magnetohydrodynamic (MHD) activity in NSTX has been found to induce striated heat flux patterns at the divertor. These striated heat fluxes were previously interpreted as strike-point splitting caused by stochastic magnetic lobes near the X-point. Recent analysis indicates that MHD can directly generate filaments in the scrape-off layer (SOL), and the MHD-related filaments are consistent with the rotation and the frequency of the MHD. Magnetic field line tracing from the mid-plane of the MHD-related filaments to the divertor is consistent with the location of striated heat fluxes on the divertor. Additionally, gas puff imaging (GPI) diagnostic data shows the generation of regular blobs following each edge harmonic oscillation (EHO) toroidal mode number n = 1 perturbation, which indicates that the MHD perturbation directly drives the blobs. These blobs are responsible for the divertor heat flux striations. Here, this finding provides a new framework for understanding MHD-induced edge transport and has important implications for heat-load control in NSTX-U and future spherical tokamaks.

MHD↗

High-Fidelity Multiphysics Modeling of a Heat Pipe Microreactor Using BlueCrab

Researchers who are actively developing nuclear microreactors are planning to employ innovative designs and features using traditional commercial modeling tools that may be inadequate for their design and licensing activities. The codes developed under the U.S. Department of Energy Office of Nuclear Energy Advanced Modeling and Simulation (NEAMS) program provide flexibility in terms of geometry modeling and multiphysics coupling and are particularly well suited for modeling novel microreactor concepts. To test the maturity of these codes, this paper introduces a conceptual heat pipe microreactor (HP-MR) designed to gather various technologies of interest to microreactor developers such as control drums, heat pipes, and hydride moderators. Here, the objective of this effort is to demonstrate NEAMS tools capability to perform high-fidelity multiphysics simulations, using coupled neutronics (via the Griffin code), heat conduction (via the BISON code), heat pipe modeling (via the Sockeye code), and hydrogen redistribution in hydride metal moderator (via the SWIFT code). Codes are coupled in-memory through the Multiphysics Object-Oriented Simulation Environment (MOOSE) framework, which permits flexible multiphysics data transfer schemes. The analysis confirmed two key aspects of the HP-MR concept: (1) its ability to follow the power load requested from the heat pipe and (2) its ability to avoid heat pipe cascading failure unless designed with high power close to operating failure limits of its heat pipes. The developed computational model was distributed publicly on the Virtual Test Bed for training purposes to accelerate adoption by industry and to provide a high-fidelity multiphysics solution for benchmarking against other tools. Additional multiphysics analyses including other transients and coupled physics were identified as necessary future work, together with a focus on validating multiphysics behavior against experiments.

Microreactor↗

Collaboration to Enable Higher Penetrations of Solar Power Generation Using the Natural Gas Pipeline System for Energy Storage (CRADA CRD-14-00567)

This unique project explored one possible solution for photovoltaic (PV) generation to become a reliable and dispatchable energy resource similar to conventional baseload fossil fuel electricity generation. Solar power generation is a renewable resource that varies naturally from day-to-day as well as seasonally. To use solar power as a baseload generation asset requires a flexible storage system that can recover power on both a daily and seasonal basis. Converting solar power to natural gas (i.e., first to hydrogen and then to methane) and having access to utility-scale storage in the natural gas network has the potential to make solar power generation a baseload asset. This will: 1) Increase the net energy yield from solar resources by increasing the effective capacity factor and maximize the energy produced during the assets’ lifetimes. 2) Improve the economics of energy storage for solar project developers, thereby accelerating the deployment of new solar generation. 3) Reduce the impact of increasing solar penetration on congestion of the electrical transmission system by shifting power delivery in time using the gas pipeline network for long-duration storage. 4) Reduce the impact of increasing solar generation on electrical distribution system control. 5) Offer alternative revenue sources for solar power generation beyond electricity including: hydrogen (H 2 ) production for stationary fuel cells and fuel cell electric vehicles, conversion of carbon dioxide (CO 2 ) to methane (CH 4 ) as a direct drop-in replacement for fossil natural gas use, and transmission as high volumetrically-dense CH 4 for use in transportation, heating, power generation, chemical production or conversion back to H2 at the point of use. Additional work was added to this CRADA in modification 4 having a primary objective to characterize the performance of the electrolyzer, Southern California Gas (SoCalGas) bioreactor and balance of plant to demonstrate production of renewable natural gas (RNG) from renewable H 2 and CO 2 using single-cell, self-replicating organisms. The additional scope of work allowed researchers to ramp up gas flowrates and pressure of the system over the designed range to grow the cells and begin to show the load-following capabilities of this anaerobic gas fermentation process. These activities enabled the research team to predict system performance at much greater scales; namely 10’s of mega-watts (MWs) of electrolyzer nameplate capacity.

14 SOLAR ENERGY↗

Flashlamp drive system for a high-energy 10–100 kHz pulse-burst Nd:YAG laser

We present the design of the flashlamp drive system for the NG100 laser, a 1 J/pulse, 10–100 kHz, pulse-burst Nd:YAG laser system being developed for application in a Thomson scattering plasma diagnostic. This flashlamp drive system is under active development, with a prototype now being constructed. The flashlamp drive system is modular, with each module capable of driving a series pair of linear flashlamps. Each drive module contains and is controlled by a dedicated Analog Regulator Controller. Thus each module is independently operable and controllable. This modular approach imposes no intrinsic limit to the number of modules that may be applied to drive the flashlamp pairs in a laser system. Each flashlamp drive module has a switch-regulated topology. An 1800 V main capacitor bank provides 25 kJ of energy storage, while a lower voltage output capacitor bank provides filtering and the initial energy delivered to the flashlamps at the start of the drive pulse. The main bank is recharged after each flashlamp drive pulse. As energy is drawn from the output bank by the flashlamps, an IGBT switching regulator feeds current from the main bank through an inductor to replenish the output capacitor bank. The rate of replenishment is feedback-controlled to maintain a regulated supply of power to the flashlamp load, with a setpoint range of 0.07 to 1.65 MW. An Analog Regulator Controller produces two-state variable pulse width feedback switching of the regulator IGBT. The switching frequency is ≤ 20 kHz, dynamically adjusted to limit ripple of the flashlamp power to ±3% statistical standard deviation of mean. For development or troubleshooting, each module is operable independent of the laser digital control system (microcontroller and FPGA).

Plasma diagnostics - interferometry↗

Probabilistic Voltage Sensitivity based Preemptive Voltage Monitoring in Unbalanced Distribution Networks

With increasing penetration of renewable energy and active consumers, control and management of power distribution networks has become challenging. Renewable energy sources can cause random voltage fluctuations as their output power depends on weather conditions. Conventional voltage control schemes such as tap changers and capacitor banks lack the foresight required to quickly alleviate voltage violations. Thus, there is an urgent need for effective approaches for predicting and mitigating voltage violations as a result of random fluctuations in power injections. This work proposes a novel voltage monitoring approach based on low-complexity, data-driven probabilistic voltage sensitivity analysis. The usefulness of this work is not only in predicting voltage violations in unbalanced distribution grids, but also in opening up the door for optimal voltage control. Using system data and forecasts, the proposed approach predicts the distribution of system node voltages which is then used to to identify nodes that may violate the nominal operational limits with high probability. The method is tested on the IEEE 37 node distribution system considering integrated distributed solar energy sources. The method is validated against the classic load flow based method and offers over 95% accuracy in predicting voltage violations.

Abujubbeh, Mohammad↗

The role of the Pt-group dehydrogenation catalyst in alkane metathesis for polyolefin deconstruction

Recent proposed approaches in the depolymerization of waste plastics employ an olefin intermediate to produce alkanes or alkenes using olefin metathesis in tandem chemistry. Here, in this study, we investigated the role of the dehydrogenation catalyst on reaction rate, kinetics, and product distribution in heterogeneous tandem dehydrogenation and olefin metathesis (alkane metathesis) of three different alkane reactants, including polyethylene. We found that many properties to which alkane dehydrogenation rates were sensitive-including metal composition, nanoparticle size, and surface doping of Re species also controlled activity in Tandem D/OM. When comparing Pd, Pt, and Pt 3 Sn 1 , supported Pd in tandem with a Re 2 O 7 olefin metathesis catalyst showed four-fold higher activity (surface area basis) compared to Pt or Pt 3 Sn 1 catalysts on the same support, mainly due to differences in the rate of hydrogenation. Catalyst preparation resulted in metal nanoparticles partially covered by ReO x , as seen from elemental mapping. Co-location of Re 2 O 7 and Pd correlated with increased rates of hydrogenation (i.e., an increase in the rate of alkane formation and simultaneous lowering of the rate of alkene formation), with a reaction order in catalyst study that further supported this conclusion. The Pd and Re 2 O 7 system displayed marked improvement compared to Pt or Pt 3 Sn 1 with Re 2 O 7 , and previous work, in the depolymerization rate of a linear polyethylene feedstock, with over 94 % reduction in polymer molecular weight in 15 h at 190 °C using less catalyst and increased reactant loadings, while keeping solvent to polymer consumption below 2.5.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Application of pH-dependent environmental protection agency test method 1313 to low-activity nuclear waste glass

Here, in this study, we present results of a room temperature, pH-dependent leach test established by United States Environmental Protection Agency (EPA) Leaching Environmental Assessment Framework (LEAF) (EPA Method 1313 and further abbreviated EPA 1313) to study the alteration behavior of low-activity nuclear waste (LAW) glasses. Implementation of EPA 1313, which is closer to LAW disposal temperatures, could allow for more flexibility in the formulation of Hanford LAW glasses, specifically in terms of increased waste loading. A set of 48 LAW glasses were selected to test with EPA 1313. Briefly, the test method consists of adding glass to a number of solutions at different initial pH values and at a fixed mass-to-solution-volume ratio. The glass is then allowed to corrode for two days and the final solution pH and concentration of different glass elements in solution is measured. The test was modified from the published procedure to constrain particle size to provide more reproducible results, reduce the studied pH range to a more applicable range, and to reduce solution volume to reduce costs associated with material preparation. Compositional modeling was used to predict the measured elemental releases at various pH. The model predictions improved in tests where there was a relatively small difference between initial and final solution pH indicating that pH controls would result in better predictive models.

Accelerated aging↗