Search NASA⌕ Search

SEARCH · Search NASA

Results for “adaptive sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Adaptive antenna arrays for satellite communication

The feasibility of using adaptive antenna arrays to provide interference protection in satellite communications was studied. The feedback loops as well as the sample matric inversion (SMI) algorithm for weight control were studied. Appropriate modifications in the two were made to achieve the required interference suppression. An experimental system was built to test the modified feedback loops and the modified SMI algorithm. The performance of the experimental system was evaluated using bench generated signals and signals received from TVRO geosynchronous satellites. A summary of results is given. Some suggestions for future work are also presented.

Gupta, Inder J.↗

Development of Turbulence-Measuring Equipment

Hot wire turbulence-measuring equipment has been developed to meet the more stringent requirements involved in the measurement of fluctuations in flow parameters at supersonic velocities. The higher mean speed necessitates the resolution of higher frequency components than at low speed, and the relatively low turbulence level present at supersonic speed makes necessary an improved noise level for the equipment. The equipment covers the frequency range from 2 to about 70,000 cycles per second. Constant-current operation is employed. Compensation for hot-wire lag is adjusted manually using square-wave testing to indicate proper setting. These and other features make the equipment adaptable to all-purpose turbulence work with improved utility and accuracy over that of older types of equipment. Sample measurements are given to demonstrate the performance.

Kovasznay, Leslie S G↗

An efficient implementation of Forward-Backward Least-Mean-Square Adaptive Line Enhancers

An efficient implementation of the forward-backward least-mean-square (FBLMS) adaptive line enhancer is presented in this article. Without changing the characteristics of the FBLMS adaptive line enhancer, the proposed implementation technique reduces multiplications by 25% and additions by 12.5% in two successive time samples in comparison with those operations of direct implementation in both prediction and weight control. The proposed FBLMS architecture and algorithm can be applied to digital receivers for enhancing signal-to-noise ratio to allow fast carrier acquisition and tracking in both stationary and nonstationary environments.

Yeh, H.-G.↗

NASA Johnson Space Center Biomedical Research Resources

Johnson Space Center (JSC) medical sciences laboratories constitute a national resource for support of medical operations and life sciences research enabling a human presence in space. They play a critical role in evaluating, defining, and mitigation the untoward effect of human adaption to space flight. Over the years they have developed the unique facilities and expertise required to perform: biomedical sample analysis and physiological performance tests supporting medical evaluations of space flight crew members and scientific investigations of the operationally relevant medical, physiological, cellular, and biochemical issues associated with human space flight. A general overview of these laboratories is presented in viewgraph form.

Paloski, W. H.↗

Principles, Techniques, and Applications of Tissue Microfluidics

The principle of tissue microfluidics and its resultant techniques has been applied to cell analysis. Building microfluidics to suit a particular tissue sample would allow the rapid, reliable, inexpensive, highly parallelized, selective extraction of chosen regions of tissue for purposes of further biochemical analysis. Furthermore, the applicability of the techniques ranges beyond the described pathology application. For example, they would also allow the posing and successful answering of new sets of questions in many areas of fundamental research. The proposed integration of microfluidic techniques and tissue slice samples is called "tissue microfluidics" because it molds the microfluidic architectures in accordance with each particular structure of each specific tissue sample. Thus, microfluidics can be built around the tissues, following the tissue structure, or alternatively, the microfluidics can be adapted to the specific geometry of particular tissues. By contrast, the traditional approach is that microfluidic devices are structured in accordance with engineering considerations, while the biological components in applied devices are forced to comply with these engineering presets.

Wade, Lawrence A.↗

Coupled Elastic-Thermal Dynamics of Deployable Mesh Reflectors

This paper presents a coupled elastic-thermal dynamic model and a quasi-static strategy on the analysis of the reflector dynamics in the space mission. The linearized model, its natural frequencies and mode shapes are then derived upon the nonlinear static equilibrium of the structure. The numerical example is provided to fully adapt the strategy and investigate the dynamic behaviors of the structure. Finally the proposed method is applied on the sample of the deployable mesh reflector and the simulation results are presented. The research work delivered in the paper will be used to design the feedback surface in future.

fixed boundaries↗

The Affect of the Space Environment on the Survival of Halorubrum Chaoviator and Synechococcus (Nageli): Data from the Space Experiment OSMO on EXPOSE-R

We have shown using ESA's Biopan facility flown in Earth orbit that when exposed to the space environment for 2 weeks the survival rate of Synechococcus (Nageli), a halophilic cyanobacterium isolated from the evaporitic gypsum-halite crusts that form along the marine intertidal, and Halorubrum chaoviator a member of the Halobacteriaceae isolated from an evaporitic NaCl crystal obtained from a salt evaporation pond, were higher than all other test organisms except Bacillus spores. These results led to the EXPOSE-R mission to extend and refine these experiments as part of the experimental package for the external platform space exposure facility on the ISS. The experiment was flown in February 2009 and the organisms were exposed to low-Earth orbit for nearly 2 years. Samples were either exposed to solar ultraviolet (UV)-radiation (lambda is greater than 110 nm or lambda is greater than 200 nm, cosmic radiation (dosage range 225-320 mGy), or kept in darkness shielded from solar UV-radiation. Half of each of the UV-radiation exposed samples and dark samples were exposed to space vacuum and half kept at 105 pascals in argon. Duplicate samples were kept in the laboratory to serve as unexposed controls. Ground simulation control experiments were also performed. After retrieval, organism viability was tested using Molecular Probes Live-Dead Bac-Lite stain and by their reproduction capability. Samples kept in the dark, but exposed to space vacuum had a 90 +/- 5% survival rate compared to the ground controls. Samples exposed to full UV-radiation for over a year were bleached and although results from Molecular Probes Live-Dead stain suggested approximately 10% survival, the data indicate that no survival was detected using cell growth and division using the most probable number method. Those samples exposed to attenuated UV-radiation exhibited limited survival. Results from of this study are relevant to understanding adaptation and evolution of life, the future of life beyond earth, the potential for interplanetary transfer of viable microbes via meteorites and dust particles as well as spacecraft, and the physiology of halophiles.

space flight↗

Visualization and Quantification of Rotor Tip Vortices in Helicopter Flows

Helicopter aeromechanics encompasses a highly vortical flow field. The vortices generated at each blade tip contain unsteady, complex, three-dimensional structures, which interact with each other, other blades, the fuselage and various components of the helicopter. It is crucial to understand vortex kinematics and their subsequent dynamic evolution. Much research has been devoted to the understanding of helicopter vortex dynamics, including a number of experimental studies.1-6 In May 2010 Particle Image Velocimetry (PIV) measurements of a full-scale UH-60A rotor were acquired in the National Full-Scale Aerodynamics Complex (NFAC) 40- by 80-Foot Wind Tunnel.1 These measurements were taken at a plane just downstream of the advancing blade in the vicinity of the blade tip—the so-called PIV plane. The resulting PIV data were then processed using an ensemble-average approach to create graphical representations of the vortical wake velocity and vorticity fields, which, in turn, have enhanced the understanding of rotorcraft vortical wake flow field physics and have provided a more detailed validation of vortical wake computer simulations.7 A common approach used to analyze flow field features is to compute and plot color contour maps of various scalar quantities such as pressure, velocity magnitude and vorticity magnitude. For example, the color map of the vorticity magnitude is typically used to determine vortical flow structure. With this approach the vortex core may appear larger or smaller, depending on the contour levels that are selected. Thus, the resulting visualization is sensitive to user-specified contour levels. For vortex core radius measurements, it is more accurate to calculate the vortex core radius using the cross-flow velocity profile across the vortex core. The task of extracting the cross-flow velocity profile can be time consuming with existing tools since the user needs to manually select the core center then specify sampling points along the profile axis. The task becomes even more challenging when the associated grid system uses AMR (Adaptive Mesh Refinement) where the profile axis could span multiple grid blocks. There are a number of existing techniques for profiling of vortex core attributes;8-9 however, these techniques are not fully automatic in that the user still needs to select the vortex core center to compute the cross-flow velocity profile. The present study introduces a new color map scheme that is based on the vortex core radius, which is fully automatic and does not require user intervention. Analysis and visualization of blade tip vortices on the PIV plane using the proposed new color map scheme are described in Section II. The new approach is evaluated using two case studies, which are described in Section III. The paper ends with a summary in Section IV.

Quantification↗

Dermatitis during Spaceflight Associated with HSV-1 Reactivation

Human alpha herpesviruses herpes simplex virus (HSV-1) and varicella zoster virus (VZV) establish latency in various cranial nerve ganglia and often reactivate in response to stress-associated immune system dysregulation. Reactivation of Epstein Barr virus (EBV), VZV, HSV-1, and cytomegalovirus (CMV) is typically asymptomatic during spaceflight, though live/infectious virus has been recovered and the shedding rate increases with mission duration. The risk of clinical disease, therefore, may increase for astronauts assigned to extended missions (>180 days). Here, we report, for the first time, a case of HSV-1 skin rash (dermatitis) occurring during long-duration spaceflight. The astronaut reported persistent dermatitis during flight, which was treated onboard with oral antihistamines and topical/oral steroids. No HSV-1 DNA was detected in 6-month pre-mission saliva samples, but on flight day 82, a saliva and rash swab both yielded 4.8 copies/ng DNA and 5.3 × 104 copies/ng DNA, respectively. Post-mission saliva samples continued to have a high infectious HSV-1 load (1.67 × 107 copies/ng DNA). HSV-1 from both rash and saliva samples had 99.9% genotype homology. Additional physiological monitoring, including stress biomarkers (cortisol, dehydroepiandrosterone (DHEA), and salivary amylase), immune markers (adaptive regulatory and inflammatory plasma cytokines), and biochemical profile markers, including vitamin/mineral status and bone metabolism, are also presented for this case. These data highlight an atypical presentation of HSV-1 during spaceflight and underscore the importance of viral screening during clinical evaluations of in-flight dermatitis to determine viral etiology and guide treatment.

Satish K. Mehta↗

Dermatitis During Spaceflight Associated With HSV-1 Reactivation- A Case Study

Human alpha herpesviruses herpes simplex virus (HSV-1 or -2) and varicella zoster virus (VZV) establish latency in various cranial nerve ganglia, and often reactivate in response to stress-associated immune system dysregulation. Reactivation of Epstein Barr Virus (EBV), VZV, HSV-1 and Cytomegalovirus (CMV) is typically asymptomatic during spaceflight, though live/infectious virus has been recovered and the shedding rate increases with mission duration. The risk of clinical disease, therefore, may increase for astronauts assigned to extended missions (>180 days). Here, we report for the first time, a case of HSV-1 skin rash (dermatitis) occurring during a long duration spaceflight. The astronaut reported persistent dermatitis during flight, which was treated onboard with oral antihistamines and topical/oral steroids. No HSV-1 DNA was detected in 6-month pre-mission saliva samples, but on flight day 82, a saliva and rash swab both yielded 4.8 copies/ng DNA and 5.3×104 copies/ng DNA, respectively. Post-mission saliva samples continued to have high infectious HSV-1 load (1.67×107 copies/ng DNA). HSV-1 from both rash and saliva samples had 99.4% genotype homology. Additional physiological monitoring, including stress biomarkers (cortisol, dehydroepiandrosterone (DHEA), and salivary amylase), immune markers (adaptive regulatory and inflammatory plasma cytokines) and biochemical profile markers including vitamin/mineral status and bone metabolism are also presented for this case. These data highlight an atypical presentation of HSV-1 during spaceflight and underscore the importance of viral screening during clinical evaluations of in-flight dermatitis, to determine viral etiology and guide treatment.

Herpes, Viral Reactivation, Spaceflight, Dermatiti↗

Adaptive variable-length coding for efficient compression of spacecraft television data.

An adaptive variable length coding system is presented. Although developed primarily for the proposed Grand Tour missions, many features of this system clearly indicate a much wider applicability. Using sample to sample prediction, the coding system produces output rates within 0.25 bit/picture element (pixel) of the one-dimensional difference entropy for entropy values ranging from 0 to 8 bit/pixel. This is accomplished without the necessity of storing any code words. Performance improvements of 0.5 bit/pixel can be simply achieved by utilizing previous line correlation. A Basic Compressor, using concatenated codes, adapts to rapid changes in source statistics by automatically selecting one of three codes to use for each block of 21 pixels. The system adapts to less frequent, but more dramatic, changes in source statistics by adjusting the mode in which the Basic Compressor operates on a line-to-line basis. Furthermore, the compression system is independent of the quantization requirements of the pulse-code modulation system.

Rice, R. F.↗

Brine organisms and the question of habitat-specific adaptation

The question of adaptivity to extremely saline water environments is discussed, with attention given to the evolutionary performance of four common organisms including Cladonia skottsbergii, Penicillium notatum, Nostoc, and Dunaliella salina. Samples of each organism were collected and subjected to experimental conditions similar to extreme marine and limnetic environments in the Dead Sea and Don Juan Pond in the upper Wright valley of Antarctica. Measurements were made of isotope uptake and carbon dioxide production, and photoautotrophs were taken. It is found that all of the organisms responded quickly to the need to adapt to the extreme environments. It is concluded that a degree of uncertainty exists in the perception that the abundance of bulk water on the earth is in itself essential for life.

Siegel, B. Z.↗

Development of an advanced spacecraft tandem mass spectrometer

The purpose of this research was to apply current advanced technology in electronics and materials to the development of a miniaturized Tandem Mass Spectrometer that would have the potential for future development into a package suitable for spacecraft use. The mass spectrometer to be used as a basis for the tandem instrument would be a magnetic sector instrument, of Nier-Johnson configuration, as used on the Viking Mars Lander mission. This instrument configuration would then be matched with a suitable second stage MS to provide the benefits of tandem MS operation for rapid identification of unknown organic compounds. This tandem instrument is configured with a newly designed GC system to aid in separation of complex mixtures prior to MS analysis. A number of important results were achieved in the course of this project. Among them were the development of a miniaturized GC subsystem, with a unique desorber-injector, fully temperature feedback controlled oven with powered cooling for rapid reset to ambient conditions, a unique combination inlet system to the MS that provides for both membrane sampling and direct capillary column sample transfer, a compact and ruggedized alignment configuration for the MS, an improved ion source design for increased sensitivity, and a simple, rugged tandem MS configuration that is particularly adaptable to spacecraft use because of its low power and low vacuum pumping requirements. The potential applications of this research include use in manned spacecraft like the space station as a real-time detection and warning device for the presence of potentially harmful trace contaminants of the spacecraft atmosphere, use as an analytical device for evaluating samples collected on the Moon or a planetary surface, or even use in connection with monitoring potentially hazardous conditions that may exist in terrestrial locations such as launch pads, environmental test chambers or other sensitive areas. Commercial development of the technology could lead to a new family of environmental test instruments that would be small and portable, yet would give quick analyses of complex samples.

Drew, Russell C.↗

Integrated fluorescence light microscopy-guided cryo-focused ion beam-milling for in situ montage cryo-ET

Cryogenic-electron tomography (cryo-ET) permits the in situ visualization of biological macromolecules at the molecular level. Owing to the variable thickness of cells, tissues and organisms, frozen specimens may need to be thinned by cryo-focused ion beam (FIB) milling to produce thin (<500 nm) cryo-lamellae suitable for cryo-ET. Locating regions of interest remains a challenge because untargeted milling can lead to inadvertent ablation and removal of regions of interest. Correlative light and electron microscopy, combined with cryo-FIB milling, can guide the identification of labeled targets in the cellular milieu. Multiple transfers between cryo-imaging instruments, cumbersome correlation algorithms, limited accuracy and low throughput have hindered the routine adoption of cryo-FIB milling within a multimodal correlative workflow for in situ structural biology. Here, in this study, we present a workflow for 3D correlative cryo-fluorescence light microscopy-FIB-ET that streamlines fluorescence light microscopy-guided FIB milling, improving throughput while preserving both structural and contextual information. The complete integration of hardware and software described here minimizes sample contamination from cross-platform exchanges and greatly enhances the efficiency of 3D targeting in cryo-milling. We then describe procedures for implementing montage parallel array cryo-ET (MPACT), which can be easily adapted to any modern life-science transmission electron microscope. MPACT supports high-throughput cryo-ET acquisitions (10 tilt series in 1.5 h) for structure determination and comprehensive contextual understanding of macromolecules within their native surroundings. A complete session from sample preparation to MPACT data processing takes 5−7 d for an individual experienced in both cryo-EM and cryo-FIB milling.

Yang, Jie E. [Univ. of Wisconsin, Madison, WI (Uni↗

Classical and quantum simulations of 1+1-dimensional ${\mathbb{Z}}_{2}$ gauge theory at finite temperature and density

Simulating strongly coupled gauge theories at finite temperature and density is a longstanding challenge in nuclear and high-energy physics with fundamental implications for condensed matter physics. Here, we simulate such systems using minimally entangled typical thermal state (METTS) approaches, which combine classical random sampling with imaginary-time evolution, implementable on either classical or quantum computers, to estimate thermal averages of observables. We study 1+1-dimensional ${\mathbb{Z}}_{2}$ gauge theory coupled to spinless fermionic matter, which maps onto a local quantum spin chain. We benchmark both a classical matrix-product-state implementation of METTS and a recently proposed adaptive variational approach for near-term quantum devices, focusing on the equation of state and measures of fermion confinement. Of particular importance is the choice of basis for METTS sampling, which impacts both the sampling overhead and quantum circuit complexity. Our work sets the stage for future studies of strongly coupled gauge theories using classical and quantum hardware.

Chen, I-Chi [Iowa State Univ., Ames, IA (United St↗

Exploring Ion Mobility Mass Spectrometry Data File Conversions to Leverage Existing Tools and Enable New Workflows

Ion mobility (IM) is often combined with LC-MS experiments to provide an additional dimension of separation for complex sample analysis. While highly complex samples are better characterized by the full dimensionality of LC-IM-MS experiments to uncover new information, downstream data analysis workflows are often not equipped to properly mine the additional IM dimension. For many samples the data acquisition benefits of including IM separations are all that is necessary to uncover sample information and the full dimensionality of the data is not required for data analysis. Post-acquisition reduction and adaptation of the dimensions of LC-IM-MS and IM-MS experiments into an LC-MS format opens the possibility to use a plethora of existing software tools. In this work, we developed data file conversion tools to reduce the complexity of IM data analysis. Three data file transformations are introduced in the PNNL PreProcessor software: 1) mapping the IM axis to the LC axis for IM-MS data, 2) converting the drift time vs. m/z space to CCS/z vs m/z space, and 3) transforming All Ions IM/MS mobility aligned fragmentation data to a standard LC-MS DDA data file format. Finally, these new data file conversions are demonstrated with corresponding lipidomics and proteomics workflows that leverage existing LC-MS data analysis software to highlight the benefits of the data transformations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Research and development of a luminol-carbon monoxide flow system

Adaption of the luminol-carbon monoxide injection system to a flowing type system is reported. Analysis of actual wastewater samples was carried out and revealed that bacteria can be associated with particles greater than 10 microns in size in samples such as mixed liquor. Research into the luminol reactive oxidation state indicates that oxidized iron porphyrins, cytochrome-c in particular, produce more luminol chemiluminescence than the reduced form. Correlation exists between the extent of porphyrin oxidation and relative chemiluminescence. In addition, the porphyrin nucleus is apparently destroyed under the current chemiluminescent reaction conditions.

Thomas, R. R.↗

Ground-Based Measurements of Stratospheric Composition from Mt. Barcroft, California

The MkIV is an FTIR spectrometer designed and built at JPL in the 1980's for remote sensing the composition of the Earth's atmosphere by solar absorption spectrometry. Optically, MkIV is very similar to the JPL ATMOS instrument, which flew three times on the Space Shuttle. Both use double-passed configurations with a KBr beamsplitter and compensator, in order to cover the mid-infrared. The main advantage of the MkIV is that it uses two detectors in parallel, a HgCdTe photoconductor for the long wavelengths and an InSb photodiode for the short wavelengths, allowing the entire 650 to 5650/cm region to be measured simultaneously. At a 10 kHz sampling rate, each 130 cm OPD interferogram takes 3 minutes to acquire. This paper describes how the MkIV instrument was adapted for remote operation from the Barcroft site, where the harsh winter conditions make access difficult. Some of the main technical challenges will be discussed including, (i) operation from solar panels and batteries, (ii) cooling the detectors with LN2, (iii) instrument control and monitoring over a cellular phone, and (iv) data storage, processing and analysis. Finally, MkIV spectra measured from Barcroft are compared with those measured from JPL to highlight the advantages of the higher altitude site.

Toon, G. C.↗