Search NASA⌕ Search

SEARCH · Search NASA

Results for “adjust”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Checking nonflow assumptions and results via PHENIX published correlations in p+p, p+Au, d+Au, and 3 He+Au at √ s NN=200 GeV

Recently the PHENIX Collaboration has made available two-particle correlation Fourier coefficients for multiple detector combinations in minimum bias p+p and 0–5% central p+Au, d+Au, and 3 He+Au collisions at √ s NN = 200 GeV [Phys. Rev. C 105, 024901 (2022)]. Using these coefficients for three sets of two-particle correlations, azimuthal anisotropy coefficients v 2 and v 3 are extracted for midrapidity charged hadrons as a function of transverse momentum. In this paper, we use the available coefficients to explore various nonflow hypotheses as well as to compare the results with theoretical model calculations. The nonflow methods fail basic closure tests with ampt and pythia/angantyr, particularly when including correlations with particles in the low multiplicity light-projectile going direction. In data, the nonflow adjusted v 2 results are modestly lower in p+Au and the adjusted v 3 results are more significantly higher in p+Au and d+Au. However, the resulting higher values for the ratio v 3 /v 2 in p+Au at RHIC compared to p+Pb at the LHC is additional evidence for a significant overcorrection. Incorporating these additional checks, the conclusion that these flow coefficients are dominated by initial geometry coupled with final-state interactions (e.g., hydrodynamic expansion of quark-gluon plasma) remains true, and explanations based solely on initial-state glasma are ruled out. The detailed balance between intrinsic and fluctuation-driven geometry and the exact role of weakly versus strongly coupled prehydrodynamic evolution remains an open question for triangular flow, requiring further theoretical and experimental investigation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Density matrix renormalization group description of the island of inversion isotopes F 28 – 33

Recent experiments have confirmed that the neutron-rich isotopes 28,29 F belong to the so-called island of inversion (IOI), a region of the nuclear chart around Z = 10 and N = 20 where nuclear structure deviates from the standard shell model predictions due to deformation and continuum effects. However, while the general principles leading to the IOI are relatively well understood, the details of the low-lying structure of the exotic fluorine isotopes 28–33 F are basically unknown. In this study, we perform large-scale shell model calculations including continuum states to investigate the properties of the neutron-rich isotopes 25–33 F, from a core of 24 O and using an effective two-body interaction with a small number of adjustable parameters in the central and tensor channels. We develop two models adjusted on experimentally confirmed states in 25,26 O and 25–27 F based on different assumptions concerning the positions of the neutron 0d 3/2 and 1p 3/2 shells, and solve the many-body problem using the density matrix renormalization group (DMRG) method for open quantum systems in an sd–fp model space. We obtain the first detailed spectroscopy of 25–33F in the continuum and show how the interplay between continuum effects and deformation explains the recent data on 28,29 F. Several deformed one- and two-neutron halo states are predicted in 29,31 F, and we provide some information about the possible structure of the heaviest fluorine isotopes. We also suggest several experimental studies of interest to constraint models and test the present predictions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast event-based electron counting for small-molecule structure determination by MicroED

Electron counting helped realize the resolution revolution in single-particle cryoEM and is now accelerating the determination of MicroED structures. Its advantages are best demonstrated by new direct electron detectors capable of fast (kilohertz) event-based electron counting (EBEC). This strategy minimizes the inaccuracies introduced by coincidence loss (CL) and promises rapid determination of accurate structures. We used the Direct Electron Apollo camera to leverage EBEC technology for MicroED data collection. Given its ability to count single electrons, the Apollo collects high-quality MicroED data from organic small-molecule crystals illuminated with incident electron beam flux densities as low as 0.01–0.045 e − /Å 2 /s. Under even the lowest flux density (0.01 e − /Å 2 /s) condition, fast EBEC data produced ab initio structures of a salen ligand (268 Da) and biotin (244 Da). Each structure was determined from a 100° wedge of data collected from a single crystal in as few as 50 s, with a delivered fluence of only ∼0.5 e − /Å 2 . Fast EBEC data collected with a fluence of 2.25 or 3.33 e − /Å 2 also facilitated a 1.5 Å structure of thiostrepton (1665 Da). While refinement of these structures appeared unaffected by CL, a CL adjustment applied to EBEC data further improved the distribution of intensities measured from the salen ligand and biotin crystals. However, CL adjustment only marginally improved the refinement of their corresponding structures, signaling the already high counting accuracy of detectors with counting rates in the kilohertz range. Overall, by delivering low-dose structure-worthy data, fast EBEC collection strategies open new possibilities for high-throughput MicroED.

EBEC↗

Optimization-Based Dynamic Voltage Support of Microgrids Using Energy Storage Systems

A microgrid network is characterized by a high R/X ratio, making the voltage more sensitive to active power changes compared to bulk power systems, where the voltage is regulated primarily by reactive power. Due to its sensitivity, voltage control approaches for microgrids should also consider the active power input coupling, making it very different from conventional power systems. Additionally, as the energy costs associated with active and reactive powers are different and the operational conditions of microgrids connected to active distribution systems vary over time, the ideal controller to provide voltage support must be flexible enough to handle these technical and operational constraints. This paper proposes a model predictive control approach to provide dynamic voltage support using energy storage systems. This approach uses a simplified predictive model of the system to solve the model predictive control problem. By proper selection of model predictive control weighting parameters, the quality of service provided can be adjusted to achieve the desired performance. A simulation study in MATLAB/Simulink validates the proposed approach for the Cordova, Alaska microgrid. Results show that the performance of the voltage support can be adjusted depending on the choice of weight and constraints of the controller.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Indicator-directed Dynamic Power Management for Iterative Workloads on GPU-Accelerated Systems

Modern high-performance and warehouse computing centers show strong interest in minimizing system power consumption while satisfying customers’ quality of service (QoS). Dynamic voltage and frequency scaling (DVFS) is effective for achieving this goal. Nevertheless, automating the process online and making it transparent to users must address three major challenges: (1) Complexity — today’s hardware components (e.g., CPUs, GPUs, memory, network, etc.) can be configured in several or dozens of frequency/voltage states for satisfying divergent system demands. Given their combination and the emergence of heterogeneity, searching the optimal configuration in the design space online can be timing consuming. (2) QoS guarantee — user-defined objectives such as power constraint and performance target must be monitored, predicted and ensured at the best effort. (3) Adaptability — various known and unknown workloads run on systems. Workloads characteristics should be quickly determined and configurations dynamically adjusted in accord with workloads and QoS. In this work, we focus on applications exhibiting an interesting feature – iterative or periodic, which is common among conventional HPC and emerging machine learning workloads. We propose an online dynamic power-performance (ODPP) management framework to dynamically adjust GPU DVFS configurations to meet performance and power objectives and constraints, without any code annotation or intrusion. Particularly, ODPP extracts the performance and power indicators for applications from their resources utilization profiles in a short episode. It further automatically constructs an accurate model that infers from the indicators how the application's performance and power vary with GPU core and memory frequencies. Aided with the model, for both seen and unseen applications, ODPP can quickly determine the most appropriate DVFS configuration for their execution. We evaluate ODPP on an NVIDIA GPU using multiple exascale computing (ECP) and deep learning applications.

Zou, Pengfei↗

Analysis and Experimental Testing of a New Type of Variable Stiffness Magnetic Spring with a Linear Stroke Length

In this paper a new type of variable stiffness magnetic spring is proposed. The magnetic spring is composed of radially magnetized outer rotor magnets coupled with axially magnetized inner cylindrical magnets. It is shown that this magnet arrangement creates a highly linear stroke length. By rotating the inner magnetic rotor, the stiffness of the spring can be adjusted. The force as a function of stroke length and torque required to adjust the stiffness were computed using finite element analysis and then verified using an experimental test setup.

16 TIDAL AND WAVE POWER↗

A Multi-Stack Variable Stiffness Magnetic Torsion Spring for a Wave Energy Converter

This paper presents the design of a multi-stack high torque adjustable stiffness torsional magnetic spring for use in a wave energy converter. The torsional magnetic spring has a ±45 degrees linear stroke length with peak torque of 823 N⋅m. A 3-D magnetostatic finite element analysis parameter sizing sweeping analysis was performed and the peak energy density for the selected torsion spring was computed to be 12.6 J/kg. The required torque was increased by using a unique seven-stage multi-stacking design. The stiffness of magnetic torsion spring is adjusted through the axial translation of the inner rotor. The presented design is shown to be capable of providing both positive and negative stiffness with equal characteristics and has a very high degree of linearity. The experimental prototype assembly and test-setup used to verify the torsional spring performance is presented.

16 TIDAL AND WAVE POWER↗

Cost-Benefit Analysis of Grid-Supportive Loads for Fast Frequency Response

Flexibility in inverter-based loads could be used to support the converter-dominated power grid by offering a rapid, autonomous, and adjustable power reserve during system transients to help maintain system stability. Based on technical potential, ancillary service (AS) value, and implementation costs, this study illustrates the cost-benefit analysis of grid-supportive loads (GSLs) for the supply of fast frequency response (FFR). The net benefit for each GSL is demonstrated using a case study and relevant data sources. The findings suggest that implementation costs for enabling GSL features are low compared to the value that grid operators get from the acquisition of responsive reserve services. The authors believe that, given the rising popularity of renewable energy sources, GSLs can be a useful tool for grid stability in low-inertia systems.

cost-benefit analysis↗

An ICA-Based HVAC Load Disaggregation Method Using Smart Meter Data

This paper presents an independent component analysis (ICA) based unsupervised-learning method for heat, ventilation, and air-conditioning (HVAC) load disaggregation using row-resolution (i.e., 15 minutes) smart meter data. We first demonstrate that the electricity consumption profiles on mild-temperature days can be used to approximate the base load on hot days. A residual load profile can then be calculated by subtracting the mild-day load profile from the hot-day load profile. The residual load profiles are processed using ICA for HVAC load extraction. An optimization-based algorithm is proposed for post-adjustment of the ICA results, considering two bounding factors for enhancing the robustness of the ICA algorithm. First, we use the hourly HVAC energy bounds computed from the relationship between HVAC load and temperature to remove unrealistic HVAC load spikes. Second, we exploit the dependency between the daily nocturnal and diurnal loads extracted from historical meter data to smooth the base load profile. Pecan Street data with sub-metered HVAC data were used to test and verify the proposed methods. Simulation results demonstrated that the proposed method is computationally efficient and robust across multiple customers.

Kim, Hyeonjin↗

Real-Time Model-Adaptive Relaying Applied to Microgrid Protection

In microgrids, the short-circuit current magnitude is significantly limited by more than an order of magnitude due to the relatively small inverter-based resources. Commercially available protective devices for distribution cannot reliably protect a microgrid due to their dependence on the magnitude of the fault current. Moreover, overcurrent relays typically cannot function properly for a microgrid because they are incapable of detecting faults and/or performing the coordination between the relays in inverter-based microgrids operated in the islanded mode. This paper proposes a model-adaptive relay designed to adjust the relay curves based on the available generation and the network topology. The proposed method runs a real-time model of the microgrid, which gathers information from the network to calculate the available short-circuit current in the specified node. The fault current from the model is then used for the adaptive algorithm to calculate the relay settings, considering coordination with the downstream fuses and upstream reclosers. This work presents the validation of the proposed method in Hardware-in-the-Loop, in a hardware testbed as well as field deployed in a real microgrid in East-Tennessee.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Generalized and Mechanistic PV Module Performance Prediction From Computer Vision and Machine Learning on Electroluminescence Images

Electroluminescence (EL) imaging of photovoltiac (PV) modules offers high-speed, high-resolution information about device performance, affording opportunities for greater insight and efficiency in module characterization across manufacturing, research and development, and power plant operations and management. Predicting module electrical properties from EL image features is a critical step toward these applications. In this article, we demonstrate quantification of both generalized and performance mechanism-specific EL image features, using pixel intensity-based and machine learning classification algorithms. From EL image features, we build predictive models for PV module power and series resistance, using time-series current-voltage (I-V) and EL data obtained stepwise on five brands of modules spanning three Si cell types through two accelerated exposures: damp heat (DH) (85°C/85% RH) and thermal cycling (TC) (IEC 61215). Overall, 195 pairs of EL images and I-V characteristics were analyzed, yielding 11700 individual PV cell images. A convolutional neural network was built to classify cells by the severity of busbar corrosion with high accuracy (95%). Generalized power predictive models estimated the maximum power of PV modules from EL images with high confidence and an adjusted-R 2 of 0.88, across all module brands and cell types in extended DH and TC exposures. Mechanistic degradation prediction was demonstrated by quantification of busbar corrosion in EL images of three module brands in DH, and subsequent modeling of series resistance using these mechanism-specific EL image features. For modules exhibiting busbar corrosion, we demonstrated series resistance predictive models with adjusted-R 2 of up to 0.73.

14 SOLAR ENERGY↗

Battery Degradation Modeling in Hybrid Power Plants: An Island System Unit Commitment Study: Preprint

As hybrid power plants (HPPs), such as photovoltaic (PV) and battery combinations, become increasingly important in power systems with high renewable energy penetration to address PV variability and ensure grid stability. This paper focuses on the urgent need to model the coordination between PV and battery systems in HPPs while accounting for battery degradation. We present a generation scheduling model that explicitly incorporates PV-battery hybridization in the unit commitment problem. Moreover, the cost function of the HPP scheduling problem endogenously considers battery degradation with adjustable weights to strike a balance between minimizing production costs and prolonging battery life, particularly when providing energy arbitrage and ancillary services. Using a realistic island system simulation, we demonstrate that accounting for battery degradation in the scheduling problem can significantly extend battery life with only minor additional production costs.

battery degradation↗

Post-Disturbance Dynamic Distribution System Restoration with DGs and Mobile Resources

Distributed generations (DGs) can act as emergency power supplies when distribution systems suffer from outages. However, the generation capabilities of DGs are generally limited by a number of factors including weather conditions, fuel limitations, etc. In this context, mobile resources that are able to reallocate resources to desired locations are regarded as important complements to conventional fixed DGs in assisting distribution system restoration. In this paper, a distribution system restoration model with DGs and mobile resources is proposed. Firstly, the dispatch and allocation of mobile resources are modeled with respect to the characteristics of the traffic network. Then the developed mobile resource models are integrated into the distribution system restoration model to co-optimize the scheduling of DGs and mobile resources. Uncertainty factors are managed by a model predictive control approach so that system operators can dynamically adjust the restoration strategy with the up-to-date information. The effectiveness of the proposed method is validated through an IEEE 13-bus test system.

distributed generations (DGs)↗

Transient Stability Preventive Control via Tuning the Parameters of Virtual Synchronous Generators

This paper presents an optimal preventive control (OPC) method to improve the power system transient stability via tuning the transient parameter of virtual synchronous generators. The novelty of this work is that we formulate the preventive control as an optimization problem so that inverter parameters can be adjusted at the pre-contingency stage. A reinforcement learning (RL)-driven method is proposed to solve the OPC problem with the fault energy-based reward function. An ANDES-based RL environment is also developed. Versatile functions included in the proposed environment have been presented in this paper. The proposed OPC formulation, the RLdriven method, and the fault energy-based reward function are verified on several standard test systems.

Inverter-based resources, virtual synchronous gene↗

Measurements of Six-Junction Concentrator Solar Cells

Accurate measurements of six-junction inverted metamorphic concentrator solar cells under AM1.5 direct spectrum are obtained by adjusting the spectrum of a tunable high-intensity solar simulator with custom mirrors. Isotype reference cells and broadband InGaAs QE calibration cells were developed for accurate measurements. Modeling and varying the illumination show that an unavoidable 15% - 17% overillumination on the sixth junction does not result in significant error of these 6J IMM devices. Spectrally adjusted flash measurements are independently confirmed by NREL's Cell and Module Performance team. Concentration measurements of a 6J IMM solar cell resulted in 47.1 ± 3.2% (absolute) efficiency at 143 suns.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Electro-Optical Stability in Gallium Magnesium Zinc Oxide Layers for CdTe Solar Cells

In CdTe solar cells, the emitter electron density, bandgap, and band alignment can be tuned by adjusting alloy composition and stoichiometry in gallium magnesium zinc oxide (GMZO) layers, thereby allowing for critical front interface engineering. For example, computational modeling indicates efficiency can change from 7% to 25% by adjusting these buffer properties even with fixed CdSeTe and CdTe material properties. However, the GMZO as-deposited electro-optical properties can shift during subsequent CdTe deposition, CdCl 2 annealing, and solar cell operation. Here, we examine these changes by sputtering GMZO films on glass, and measuring the electron density before and after post-deposition treatments over a range of temperatures and different ambients. We then compare GMZO to SnO 2 and MZO. The addition of Ga to MgZnO is found to have profound effects on both the electron density and electro-optical stability that should be advantageous for CdTe solar cells.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Optimization of Source Material for in-situ Arsenic Doping via Vapor Transport Deposition of CdTe Films

In-situ doping of CdTe/CdSeTe films with arsenic is performed using pre-doped source material prepared by high pressure Bridgman (HPB) melt growth. Arsenic level in the source material is varied from 1018-1020 cm-3. Correspondingly, dopant incorporation in the films prepared using vapor transport deposition (VTD) varied from 3x1017 cm-3–1x1018cm-3. In this range, dopant activation is found to inversely correlate with the dopant incorporation, suggesting compensation. The results from this study indicate film properties can be adjusted by source material.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Explainable AI for a No-Teardown Vehicle Component Cost Estimation: A Top-Down Approach

The broader ambition of this article is to popularize an approach for the fair distribution of the quantity of a system's output to its subsystems while allowing for underlying complex subsystem level interactions. Particularly, we present the use of this framework on a very specific (but generalizable) application, interesting for a more general AI audience. Here, we detail a data-driven approach to vehicle price modeling and its component price estimation by leveraging a combination of concepts from machine learning and game theory. We show an alternative to common teardown methodologies and surveying approaches for component and vehicle price estimation at the manufacturer's suggested retail price (MSRP) level that has the advantage of bypassing uncertainties involved in gathering teardown data, the need to perform expensive and biased surveying, and the need to perform retail price equivalent or indirect cost multiplier adjustments to mark up direct manufacturing costs to MSRP. This novel exercise not only provides accurate pricing of the technologies at the customer level, but also shows the, a priori known, large gaps in pricing strategies between manufacturers, vehicle classes, market segments, etc. There is also clear interaction between the price of technologies and other specifications present in vehicles. Those results are indication that old methods of manufacturer-level component costing, aggregation, and application of flat and rigid adjustment factors should be carefully examined. The findings are based on a database developed by Argonne, which includes over 64,000 vehicles covering MY1990 to MY2020 with hundreds of vehicle specs.

97 MATHEMATICS AND COMPUTING↗