Search NASA⌕ Search

SEARCH · Search NASA

Results for “analytical process”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Earthdata Cloud Analytics Project

This presentation describes a nascent project in NASA to develop a framework to support end-user analytics of NASA's Earth science data in the cloud. The chief benefit of migrating EOSDIS (Earth Observation System Data and Information Systems) data to the cloud is to position the data next to enormous computing capacity to allow end users to process data at scale. The Earthdata Cloud Analytics project will user a service-based approach to facilitate the infusion of evolving analytics technology and the integration with non-NASA analytics or other complementary functionality at other agencies and in other nations.

data services↗

Mars Hand Lens Imager (MAHLI) efforts and observations at the “Rocknest” Eolian sand shadow in Curiosity’s Gale Crater field site

The Mars Science Laboratory (MSL) mission is focused on assessing the past or present habitability of Mars, through interrogation of environment and environmental records at the Curiosity rover field site in Gale crater. The MSL team has two methods available to collect, process and deliver samples to onboard analytical laboratories, the Chemistry and Mineralogy instrument (CheMin) and the Sample Analysis at Mars (SAM) instrument suite. One approach obtains samples by drilling into a rock, the other uses a scoop to collect loose regolith fines.

Edgett, K. S.↗

Trace Elemental Abundances in Calcium-Aluminum-Rich Inclusions in CV Chondrites

Introduction: Calcium-aluminum-rich inclusions (CAIs), are the first formed solids that define the age of the Solar System [1,2]. CAIs are thought to have condensed from nebular gas [3,4] within the first <1 Ma of Solar System formation [5,6]. CAIs have experienced numerous early Solar System processes including condensation, evaporation, melting, recrystallization, and aqueous alteration [e.g., 7]. The chemical, mineralogical, and textural diversity among CAIs results from a range of chemical and physical processes recorded during nebular and parent body epoch. This study aims to explore the mineralogical, textural, and chemical compositions of CAIs including the trace elemental abundances in CAI phases to determine the early Solar System processes recorded in them. Samples and Analytical Methods: We analyzed one CAI each from CV3 chondrites Northwest Africa (NWA) 5508 designated as ‘Saguaro’, and Northwest Africa (NWA) 12772 designated as ‘Hoopoe’. Back-scatter electron (BSE) images were collected using a Phenom XL scanning electron microscope (SEM) at the Lunar and Planetary Institute (LPI) and the JEOL JXA-8530F electron probe microanalyzer (EPMA) at Johnson Space Center (JSC)-NASA. Additionally, energy dispersive X-ray spectrometry (EDS) elemental maps of select areas for these samples were collected using a 15.0kV beam energy and a 40µA emission current. Using the EPMA, wavelength-dispersive X-ray spectroscopy (WDS) quantitative data were collected. In-situ trace element measurements for both CAIs were determined at JSC-NASA using a Photon Machines 193nm laser ablation system and a Thermo-Scientific Element-XR inductively coupled plasma mass spectrometer (ICP-MS). Analyses consisted of 30s ablations at 10Hz, spot sizes of 20-25µm, and a fluence of 6.0 J/cm2 for anorthite and melilite, and a 3.5 J/cm2 fluence for all other phases. NIST612 was used to correct for instrument drift, while BHVO-2g was used as a primary calibration standard. BCR-2g and in-house mineral standards were regularly measured as unknowns to ensure accuracy. Results: Saguaro is a coarse-grained CAI, ~11 x 6 mm in dimensions. Saguaro contains spinel, Al-rich pyroxene, anorthite, Mg-rich melilite, and minor perovskite in its interior and is therefore classified as a Type B CAI. Individual melilite grains shows normal compositional zoning with an Ak content ranging from ~24 to 54 with no apparent trend from the core to the edge of the CAI. The spinel appears euhedral and occurs both as clusters and as spinel palisades [8]. Two rim sequences surround most of the sample: the inner rim being a Wark-Lovering (WL) rim (~10-35 µm) containing pyroxene, spinel, and melilite (or anorthite), and the outer rim is a finer-grained, thicker (~100 µm), accretionary rim (Fig. 1). The mineral phases in Saguaro record an overall flat REE pattern with an average negative Eu anomaly in pyroxene, and an average positive Eu anomaly in anorthite and melilite respectively. Anorthite, melilite, and pyroxene have a minor depletion in Tm (Fig. 2). The Hoopoe CAI is a compact, coarse-grained ~6 × 4 mm in size. The major mineralogy includes hibonite, spinel, melilite, anorthite, and perovskite. Therefore, it is classified as a compact transitional type A and B. (?)zoning was observed in some hibonites. Individual melilite grains show both reverse and normal zoning, where the Ak content ranges from ~6- to 28. Melilite shows two distinct textures. One texture consisted of smooth melilite that appeared homogenous, while the second appeared to consist of many fine fractures. The spinel also often appears clustered. The WL-rim sequence surrounding Hoopoe is ~25 µm thick and composed of spinel, perovskite, hibonite, and melilite/anorthite. It is then partially surrounded by an outer accretionary rim (~75µm). Like before, refractory metal nuggets appeared concentrated near the WL rims. Other metal assemblages rich in Fe and Ni were also observed. All major mineral phases in Hoopoe display relatively flat REE patterns, except for varying Eu and Tm between phases (Fig. 2). There is a prominent negative Eu anomaly in perovskite and an average positive Eu anomaly in spinel, anorthite, and hibonite respectively (Fig. 2, 3). The mixed phases along the rim of the CAI also display a negative Eu anomaly, and all phases the CAI were depleted in Pb. Discussion: The CV3 CAIs analyzed in this study were classified based on their mineralogy and textures into Type A versus Type B CAIs [10]. Hibonite appears to be pseudomorphically replacing the spinel, (i.e., is hibonite in composition, but appears in the shape of spinel). Spinel palisades. The presence of spinel palisades present in Saguaro are consistent with the melting and recrystallization experienced by this CAI. Trace elemental analyses. Saguaro and Hoopoe display similar trace element patterns to each other, with both appearing generally flat, with anomalies in Eu, and Tm. Melilite and anorthite display positive Eu anomalies in both CAIs, in addition to the hibonite in Hoopoe (Fig. 2). The phases that are depleted in Eu are pyroxene and perovskite in both Saguaro and Hoopoe, respectively (Fig. 3). Given that Eu is volatile in reducing environments [11], this could possibly indicate reducing conditions at the time anorthite and melilite crystallized, with the gas they formed from containing Eu. As these CAIs continued to form, this gas as a result would become depleted in Eu. This also could be supported by the propensity of anorthite and melilite to take up Eu from its surroundings and incorporate it into their structure [12]. In addition, analyzing the assemblage of the phases in the Saguaro, melilite and anorthite (Eu enriched) often surround the pyroxene (Eu depleted) as they are crystallized. This intergrowth of phases and the proximity of the phases would support that the Eu is being incorporated into some phases, preventing it from incorporating into other. Trace elemental analyses of the CAI rims will be evaluated in more detail, as they are complicated by the transient signal being composed of a mixture of mineral phases. Broadly, however, the patterns in the rims of both CAIs are comparable to each other, and for Hoopoe, to the mixed phase patterns in the core (Fig. 3). Other studies have found that CAI rims can be depleted in Ce and Yb [13], however we did not observe these anomalies in the two CAIs discussed here. Given their similarity, the trace elemental analyses of the mixed interior (i.e. core) and rim phases could be interpreted as forming from similar, if not the same, reservoirs. The REE abundance between the rim and core of Hoopoe are also similar, indicating they may have formed from a gas of the same or similar composition. Acknowledgments: We thank the ASU Center for Meteorite Studies for loaning the samples used in this work and Tabb Prissel for his assistance with the analysis. Mouti Al-Hashimi thanks Sam Crossley and Cyrena Goodrich for their help with the LPI SEM training. This work was supported by the LPI Summer Intern Program in Planetary Science and the LPI Cooperative Agreement. References: [1] Connelly J.N. (2012) Science, 338, 651-655. [2] MacPherson G. J. (2014) Treatise on Geochem., 2, 139-179. [3] Grossman L. (1972) GCA, 36, 597-619. [4] Ebel, D.S. (2006) Meteorites and the Early Solar System II (D. S. Lauretta & H. Y. McSween, Eds.) 253-277. [5] MacPherson G. J. (2012) Earth Planet. Sci. Lett., 331-332, 43-54. [6] MacPherson G.J. (2017) GCA, 201, 65-82. [7] Krot A.N. (1995) Meteoritics & Planet. Sci., 30, 748-775. [8] Wark and Lovering (1982) GCA, 46, 2595-2607. [9] Palme H. and Jones A. (2003) Treatise on Geochemistry (H. D. Holland and K. K. Turekian Eds.), 1, 41-61. [10] Grossman L. (1980) Ann. Rev. Earth Planet. Sci., 8, 559-608. [11] Floss C. et al. (1996) GCA, 60, 1975-1997. [12] Mason B. and Martin P. M. (1974) Earth Planet. Sci. Lett., 22, 141-144. [13] Wark B. and Boynton W. V. (2001) Meteoritics & Planet. Sci., 36, 1135-1166.

X Mouti↗

Development of Processing Techniques for Advanced Thermal Protection Materials

Thermal Protection Materials Branch (TPMB) has been involved in various research programs to improve the properties and structural integrity of the existing aerospace high temperature materials. Specimens from various research programs were brought into the analytical laboratory for the purpose of obtaining and refining the material characterization. The analytical laboratory in TPMB has many different instruments which were utilized to determine the physical and chemical characteristics of materials. Some of the instruments that were utilized by the SJSU students are: Scanning Electron Microscopy (SEM), Energy Dispersive X-ray analysis (EDX), X-ray Diffraction Spectrometer (XRD), Fourier Transform-Infrared Spectroscopy (FTIR), Ultra Violet Spectroscopy/Visible Spectroscopy (UV/VIS), Particle Size Analyzer (PSA), and Inductively Coupled Plasma Atomic Emission Spectrometer (ICP-AES). The above mentioned analytical instruments were utilized in the material characterization process of the specimens from research programs such as: aerogel ceramics (I) and (II), X-33 Blankets, ARC-Jet specimens, QUICFIX specimens and gas permeability of lightweight ceramic ablators. In addition to analytical instruments in the analytical laboratory at TPMB, there are several on-going experiments. One particular experiment allows the measurement of permeability of ceramic ablators. From these measurements, physical characteristics of the ceramic ablators can be derived.

Selvaduray, Guna↗

Analysis of gas absorption to a thin liquid film in the presence of a zero-order chemical reaction

The paper presents a detailed theoretical analysis of the process of gas absorption to a thin liquid film adjacent to a horizontal rotating disk. The film is formed by the impingement of a controlled liquid jet at the center of the disk and subsequent radial spreading of liquid along the disk. The chemical reaction between the gas and the liquid film can be expressed as a zero-order homogeneous reaction. The process was modeled by establishing equations for the conservation of mass, momentum, and species concentration and solving them analytically. A scaling analysis was used to determine dominant transport processes. Appropriate boundary conditions were used to solve these equations to develop expressions for the local concentration of gas across the thickness of the film and distributions of film height, bulk concentration, and Sherwood number along the radius of the disk. The partial differential equation for species concentration was solved using the separation of variables technique along with the Duhamel's theorem and the final analytical solution was expressed using confluent hypergeometric functions. Tables for eigenvalues and eigenfunctions are presented for a number of reaction rate constants. A parametric study was performed using Reynolds number, Ekman number, and dimensionless reaction rate as parameters. At all radial locations, Sherwood number increased with Reynolds number (flow rate) as well as Ekman number (rate of rotation). The enhancement of mass transfer due to chemical reaction was found to be small when compared to the case of no reaction (pure absorption), but the enhancement factor was very significant when compared to pure absorption in a stagnant liquid film. The zero-order reaction processes considered in the present investigation included the absorption of oxygen in aqueous alkaline solutions of sodiumdithionite and rhodium complex catalyzed carbonylation of methanol. Present analytical results were compared to previous theoretical results for limiting conditions, and were found to have very good agreement.

Rajagopalan, S.↗

The role of process history, phase morphology and interface strength upon the mechanical properties of dispersion strengthened alloys

An analytical rationale for the sensitivity-insensitivity of dispersion-strengthened systems to process history is provided. In particular, the research was focussed upon the influence of the particle-matrix interface bond in TD-Nickel and TD-Nichrome, and the manner in which the differences in both elastic constants and thermal expansion coefficients between these phases stress this interface when these alloys are subjected to mechanical and thermal loads upon the mechanical properties of these alloys.

Ansell, G. S.↗

Analytical methodology for determination of helicopter IFR precision approach requirements

A systematic analytical approach to the determination of helicopter IFR precision approach requirements is formulated. The approach is based upon the hypothesis that pilot acceptance level or opinion rating of a given system is inversely related to the degree of pilot involvement in the control task. A nonlinear simulation of the helicopter approach to landing task incorporating appropriate models for UH-1H aircraft, the environmental disturbances and the human pilot was developed as a tool for evaluating the pilot acceptance hypothesis. The simulated pilot model is generic in nature and includes analytical representation of the human information acquisition, processing, and control strategies. Simulation analyses in the flight director mode indicate that the pilot model used is reasonable. Results of the simulation are used to identify candidate pilot workload metrics and to test the well known performance-work-load relationship. A pilot acceptance analytical methodology is formulated as a basis for further investigation, development and validation.

Phatak, A. V.↗

Sample Acquisition and Analytical Chemistry Challenges to Verifying Compliance to Aviators Breathing Oxygen (ABO) Purity Specification

NASA has been developing and testing two different types of oxygen separation systems. One type of oxygen separation system uses pressure swing technology, the other type uses a solid electrolyte electrochemical oxygen separation cell. Both development systems have been subjected to long term testing, and performance testing under a variety of environmental and operational conditions. Testing these two systems revealed that measuring the product purity of oxygen, and determining if an oxygen separation device meets Aviator's Breathing Oxygen (ABO) specifications is a subtle and sometimes difficult analytical chemistry job. Verifying product purity of cryogenically produced oxygen presents a different set of analytical chemistry challenges. This presentation will describe some of the sample acquisition and analytical chemistry challenges presented by verifying oxygen produced by an oxygen separator - and verifying oxygen produced by cryogenic separation processes. The primary contaminant that causes gas samples to fail to meet ABO requirements is water. The maximum amount of water vapor allowed is 7 ppmv. The principal challenge of verifying oxygen produced by an oxygen separator is that it is produced relatively slowly, and at comparatively low temperatures. A short term failure that occurs for just a few minutes in the course of a 1 week run could cause an entire tank to be rejected. Continuous monitoring of oxygen purity and water vapor could identify problems as soon as they occur. Long term oxygen separator tests were instrumented with an oxygen analyzer and with an hygrometer: a GE Moisture Monitor Series 35. This hygrometer uses an aluminum oxide sensor. The user's manual does not report this, but long term exposure to pure oxygen causes the aluminum oxide sensor head to bias dry. Oxygen product that exceeded the 7 ppm specification was improperly accepted, because the sensor had biased. The bias is permanent - exposure to air does not cause the sensor to return to its original response - but the bias can be accounted for by recalibrating the sensor. After this issue was found, continuous measurements of water vapor in the oxygen product were made using an FTIR. The FTIR cell is relatively large, so response time is slow - but moisture measurements were repeatable and accurate. Verifying ABO compliance for oxygen produced by commercial cryogenic processes has a different set of sample acquisition and analytical chemistry challenges. Customers want analytical chemists to conserve as much as possible. Hygrometers are not exposed to hours of continuous flow of oxygen, so they don't bias, but small amounts of contamination in valves can cause a "fail". K bottles are periodically cleaned and recertified - after cleaning residual moisture can cause a "fail". Operators let bottle pressure drop to room pressure, introduce outside air into the bottle, and the subsequent fill will "fail". Outside storage of K‐bottles has allowed enough in‐leakage, so contents will "fail".

Graf, John↗

Structural Verification of the Redesigned Space Shuttle Bipod Foam Closeout

This document outlines the structural verification approach for the Space Shuttle External Tank Forward Bipod Foam Closeout. Due to the Space Shuttle Columbia accident, debris has become a major concern. The intent of the structural verification is to ensure that any debris shed from the bipod is within acceptable limits. Since cohesive failure due to internal defects was identified as the most likely cause of the STS-107 bipod ramp foam failure, verification for this failure mode receives particular emphasis. However, all failure modes for TPS are considered and appropriate verification rationale is developed for each failure mode. Figure 1 depicts the structural verification of a production design where analysis and test are the primary methods of verification. It can be seen that the successful completion of structural verification is dependent on three main areas: 1. Production process control and quality assurance must ensure that test articles and/or analytical models are representative of (or conservatively envelope) production hardware in terms of geometry, materials and processing. Variability and defects must be considered. 2. Flight environments must be sufficiently characterized to bound driving environments for all failure modes. Applied environments, either test or analytical, must be representative of flight environments and have a load factor that satisfies design requirements. 3. Structural verification must include all failure modes. A comprehensive list of failure modes and the underlying failure mechanisms has been generated based on flight and test experience. Verification tests and / or analyses must address each failure mode. ET TPS Verification is accomplished by a combination of analysis, test, and similarity.

Poole, Eric L.↗

Stable Chlorine Isotope Study: Application to Early Solar System Materials

A significantly large mass fractionation between two stable chlorine isotopes is expected during planetary processes In addition, in view of the isotopic heterogeneity of other light elements, the chlorine isotopes can potentially be used as a tracer for the origins and evolutionary processes of early solar system materials. Due to analytical difficulties, however, current chlorine isotope studies on planetary materials are quite controversial among IRMS (gas source mass spectrometry) and/or TIMS (Thermal Ionization Mass Spectrometry) groups [i.e. 1-3]. Although a cross-calibration of IRMS and TIMS indicates that both techniques are sufficiently consistent with each other [4], some authors have claimed that the Cl-37/Cl-35 ratio of geological samples obtained by TIMS technique are, in general, misleadingly too high and variable compared to those of IRMS [3]. For example, almost no differences of Cl isotope composition were observed among mantle materials and carbonaceous meteorites by [3]. On the other hand, according to more recent IRMS work [2], significant Cl isotope variations are confirmed for mantle materials. Therefore, additional careful investigation of Cl isotope analyses are now required to confirm real chlorine isotope variations for planetary materials including carbonaceous chondrites [5]. A significantly large mass fractionation between two stable chlorine isotopes is expected during planetary processes In addition, in view of the isotopic heterogeneity of other light elements, the chlorine isotopes can potentially be used as a tracer for the origins and evolutionary processes of early solar system materials. Due to analytical difficulties, however, current chlorine isotope studies on planetary materials are quite controversial among IRMS (gas source mass spectrometry) and/or TIMS (Thermal Ionization Mass Spectrometry) groups [i.e. 1-3]. Although a cross-calibration of IRMS and TIMS indicates that both techniques are sufficiently consistent with each other [4], some authors have claimed that the 37Cl/35Cl ratio of geological samples obtained by TIMS technique are, in general, misleadingly too high and variable compared to those of IRMS [3]. For eample, almost no differences of Cl isotope composition were observed among mantle materials and carbonaceous meteorites by [3]. On the other hand, according to more recent IRMS work [2], significant Cl isotope variations are confirmed for mantle materials. Therefore, additional careful investigation of Cl isotope analyses are now required to confirm real chlorine isotope variations for planetary materials including carbonaceous chondrites [5]. In order to clarify the stable chlorine isotope features of early solar system materials, we have initiated development of the TIMS technique at NASA JSC applicable to analysis of small amounts of meteoritic and planetary materials. We report here the current status of chlorine isotope analysis at NASA JSC.

Mala,ira. M/↗

Portable Electron Microscopy for ISS and Beyond

Advances in space exploration have evolved in lockstep with key technology advances in diverse fields such as materials science, biological science, and engineering risk management. Research in these areas, where structure and physical processes come together, can proceed rapidly in part due to sophisticated ground-based analytical tools that help re-searchers develop technologies and engineering processes that push frontiers of human space exploration. Electron microscopes (EM) are an example of such a workhorse tool, lending a unique blend of strong optical scattering, high native resolution, large depth of focus, and spectroscopy via characteristic X-ray emission, providing exquisite high-magnification structural imaging and chemical analysis. Ground-based EM’s have been essential in NASA research for many years. In particular, in mineralogy and petrology, EM is used to understand the origin and evolution of the solar system, particularly rocky bodies. In microbiology, EM has helped visualize the architecture of tissues and cells. In engineering/materials science, EM has been used to characterize particulate debris in air and water samples, determine pore sizes in ceramics/catalysts, understand the nature of fibers, determine composition and morphology of new and existing materials, and characterize micro-textures of vapor deposited films. EM is highly effective at investigating a wide variety of nanoscale materials/biomaterials at the core of many of NASA’s inquiries. Despite exquisite optical performance and versatility, EM’s are traditionally large, heavy, and have high power consumption. They are also expensive so they tend to be housed at universities and large research institutions, or at major industrial laboratory sites with support staff, supplies, and skilled operators. Since most organizations cannot support their own EM, samples are often sent to these large institutions and service centers to be imaged, at great expense and of-ten with delay of weeks to months for complex analyses. Complexity, high cost, and maintenance associated with collecting EM image data has until now severely limited fields in which EM is used. Making EM accessible outside constrained terrestrial laboratory environments will bring EM’s performance and versatility to a much broader range of scientific and engineering endeavors, including in space.

Own, C. S.↗

Automated Desalting Apparatus

Because salt and metals can mask the signature of a variety of organic molecules (like amino acids) in any given sample, an automated system to purify complex field samples has been created for the analytical techniques of electrospray ionization/ mass spectroscopy (ESI/MS), capillary electrophoresis (CE), and biological assays where unique identification requires at least some processing of complex samples. This development allows for automated sample preparation in the laboratory and analysis of complex samples in the field with multiple types of analytical instruments. Rather than using tedious, exacting protocols for desalting samples by hand, this innovation, called the Automated Sample Processing System (ASPS), takes analytes that have been extracted through high-temperature solvent extraction and introduces them into the desalting column. After 20 minutes, the eluent is produced. This clear liquid can then be directly analyzed by the techniques listed above. The current apparatus including the computer and power supplies is sturdy, has an approximate mass of 10 kg, and a volume of about 20 20 20 cm, and is undergoing further miniaturization. This system currently targets amino acids. For these molecules, a slurry of 1 g cation exchange resin in deionized water is packed into a column of the apparatus. Initial generation of the resin is done by flowing sequentially 2.3 bed volumes of 2N NaOH and 2N HCl (1 mL each) to rinse the resin, followed by .5 mL of deionized water. This makes the pH of the resin near neutral, and eliminates cross sample contamination. Afterward, 2.3 mL of extracted sample is then loaded into the column onto the top of the resin bed. Because the column is packed tightly, the sample can be applied without disturbing the resin bed. This is a vital step needed to ensure that the analytes adhere to the resin. After the sample is drained, oxalic acid (1 mL, pH 1.6-1.8, adjusted with NH4OH) is pumped into the column. Oxalic acid works as a chelating reagent to bring out metal ions, such as calcium and iron, which would otherwise interfere with amino acid analysis. After oxalic acid, 1 mL 0.01 N HCl and 1 mL deionized water is used to sequentially rinse the resin. Finally, the amino acids attached to the resin, and the analytes are eluted using 2.5 M NH4OH (1 mL), and the NH4OH eluent is collected in a vial for analysis.

Spencer, Maegan K.↗

Marshall Space Flight Center's Virtual Reality Applications Program 1993

A Virtual Reality (VR) applications program has been under development at the Marshall Space Flight Center (MSFC) since 1989. Other NASA Centers, most notably Ames Research Center (ARC), have contributed to the development of the VR enabling technologies and VR systems. This VR technology development has now reached a level of maturity where specific applications of VR as a tool can be considered. The objectives of the MSFC VR Applications Program are to develop, validate, and utilize VR as a Human Factors design and operations analysis tool and to assess and evaluate VR as a tool in other applications (e.g., training, operations development, mission support, teleoperations planning, etc.). The long-term goals of this technology program is to enable specialized Human Factors analyses earlier in the hardware and operations development process and develop more effective training and mission support systems. The capability to perform specialized Human Factors analyses earlier in the hardware and operations development process is required to better refine and validate requirements during the requirements definition phase. This leads to a more efficient design process where perturbations caused by late-occurring requirements changes are minimized. A validated set of VR analytical tools must be developed to enable a more efficient process for the design and development of space systems and operations. Similarly, training and mission support systems must exploit state-of-the-art computer-based technologies to maximize training effectiveness and enhance mission support. The approach of the VR Applications Program is to develop and validate appropriate virtual environments and associated object kinematic and behavior attributes for specific classes of applications. These application-specific environments and associated simulations will be validated, where possible, through empirical comparisons with existing, accepted tools and methodologies. These validated VR analytical tools will then be available for use in the design and development of space systems and operations and in training and mission support systems.

Hale, Joseph P., II↗

Application of High Speed Digital Image Correlation in Rocket Engine Hot Fire Testing

Hot fire testing of rocket engine components and rocket engine systems is a critical aspect of the development process to understand performance, reliability and system interactions. Ground testing provides the opportunity for highly instrumented development testing to validate analytical model predictions and determine necessary design changes and process improvements. To properly obtain discrete measurements for model validation, instrumentation must survive in the highly dynamic and extreme temperature application of hot fire testing. Digital Image Correlation has been investigated and being evaluated as a technique to augment traditional instrumentation during component and engine testing providing further data for additional performance improvements and cost savings. The feasibility of digital image correlation techniques were demonstrated in subscale and full scale hotfire testing. This incorporated a pair of high speed cameras to measure three-dimensional, real-time displacements and strains installed and operated under the extreme environments present on the test stand. The development process, setup and calibrations, data collection, hotfire test data collection and post-test analysis and results are presented in this paper.

Gradl, Paul R.↗

Integration of Design, Thermal, Structural, and Optical Analysis, Including Thermal Animation

In many industries there has recently been a concerted movement toward 'quality management' and the issue of how to accomplish work more efficiently. Part of this effort is focused on concurrent engineering; the idea of integrating the design and analysis processes so that they are not separate, sequential processes (often involving design rework due to analytical findings) but instead form an integrated system with smooth transfers of information. Presented herein are several specific examples of concurrent engineering methods being carried out at Langley Research Center (LaRC): integration of thermal, structural and optical analyses to predict changes in optical performance based on thermal and structural effects; integration of the CAD design process with thermal and structural analyses; and integration of analysis and presentation by animating the thermal response of a system as an active color map -- a highly effective visual indication of heat flow.

Amundsen, Ruth M.↗

Small gas turbine combustor primary zone development

Designers of small gas turbine engines prefer a close-coupled compressor to turbine shafting arrangement, which in some designs necessitates the use of a small reverse-flow annular combustor. A design methodology for obtaining the maximum performance potential of these combustors is necessary. This paper describes an approach to optimize the design process and gain insight into primary zone performance through interactive theoretical analyses and experimental tests. Three candidate combustor designs are described which address the performance limiting problem areas associated with small annular combustors. Design methodology centers around understanding and controlling primary zone aerodynamics and the interaction of the distributed fuel with internal airflow patterns. Complete three-dimensional flow field analytical performance prediction procedures are presented and results compared with performance and emission measurements described by probes located at the exit of the primary zone. The effective use of analytical performance prediction methods in the design process is demonstrated.

Sullivan, R. E.↗

Analytics of crystal growth in space

Two crystal growth processes considered for spacelab experiments were studied to anticipate and understand phenomena not ordinarily encountered on earth. Computer calculations were performed on transport processes in floating zone melting and on growth of a crystal from solution in a spacecraft environment. Experiments intended to simulate solution growth at micro accelerations were performed.

Wilcox, W. R.↗

Functional Fault Model Development Process to Support Design Analysis and Operational Assessment

A functional fault model (FFM) is an abstract representation of the failure space of a given system. As such, it simulates the propagation of failure effects along paths between the origin of the system failure modes and points within the system capable of observing the failure effects. As a result, FFMs may be used to diagnose the presence of failures in the modeled system. FFMs necessarily contain a significant amount of information about the design, operations, and failure modes and effects. One of the important benefits of FFMs is that they may be qualitative, rather than quantitative and, as a result, may be implemented early in the design process when there is more potential to positively impact the system design. FFMs may therefore be developed and matured throughout the monitored system's design process and may subsequently be used to provide real-time diagnostic assessments that support system operations. This paper provides an overview of a generalized NASA process that is being used to develop and apply FFMs. FFM technology has been evolving for more than 25 years. The FFM development process presented in this paper was refined during NASA's Ares I, Space Launch System, and Ground Systems Development and Operations programs (i.e., from about 2007 to the present). Process refinement took place as new modeling, analysis, and verification tools were created to enhance FFM capabilities. In this paper, standard elements of a model development process (i.e., knowledge acquisition, conceptual design, implementation & verification, and application) are described within the context of FFMs. Further, newer tools and analytical capabilities that may benefit the broader systems engineering process are identified and briefly described. The discussion is intended as a high-level guide for future FFM modelers.

Verification↗