The Pioneer 10/11 meteoroid detection equipment (MDE) pressure cells were tested at liquid nitrogen (LN2) and liquid helium (LHe) temperatures with the excitation voltage controlled as a parameter. The cells failed by firing because of pressurizing gas condensation as the temperature was lowered from LN2 to LHe temperature and when raised from LHe temperature. A study was conducted to determine cell pressure as a function of temperature, and cell failure was estimated as a function of temperature and excitation voltage. The electronic system was also studied, and a profile of primary spacecraft voltage (nominally 28 Vdc) and temperature corresponding to electronic system failure was determined experimentally.
A preliminary, two-dimensional, mixed compression air induction system is designed for the Beta II Two-Stage-to-Orbit booster vehicle to minimize installation losses and efficiently deliver the required airflow. Design concepts, such as an external isentropic compression ramp and a bypass system, are developed and evaluated for performance benefits. The design is optimized by maximizing installed propulsion/vehicle system performance, and the resulting system design operating characteristics and performance are presented. The air induction system design has significantly lower transonic drag than similar designs, and only requires approximately 1/3 of the bleed extraction. In addition, the design efficiently provides the integrated system required airflow, while maintaining adequate levels of total pressure recovery. The excellent performance of this highly integrated air induction system is essential for the successful completion of the Beta II booster vehicle mission.
A preliminary, two-dimensional, mixed compression air induction system is designed for the Beta II Two Stage to Orbit booster vehicle to minimize installation losses and efficiently deliver the required airflow. Design concepts, such as an external isentropic compression ramp and a bypass system were developed and evaluated for performance benefits. The design was optimized by maximizing installed propulsion/vehicle system performance. The resulting system design operating characteristics and performance are presented. The air induction system design has significantly lower transonic drag than similar designs and only requires about 1/3 of the bleed extraction. In addition, the design efficiently provides the integrated system required airflow, while maintaining adequate levels of total pressure recovery. The excellent performance of this highly integrated air induction system is essential for the successful completion of the Beta II booster vehicle mission.
A simple control volume model has been developed to calculate the discharge coefficient through a mass flow plug (MFP) and validated with a calibration experiment. The maximum error of the model in the operating region of the MFP is 0.54%. The model uses the MFP geometry and operating pressure and temperature to couple continuity, momentum, energy, an equation of state, and wall shear. Effects of boundary layer growth and the reduction in cross-sectional flow area are calculated using an in- integral method. A CFD calibration is shown to be of lower accuracy with a maximum error of 1.35%, and slower by a factor of 100. Effects of total pressure distortion are taken into account in the experiment. Distortion creates a loss in flow rate and can be characterized by two different distortion descriptors.
Test Objectives Summary: a) Verify operation of the core simulator, the instrumentation & control system, and the ground support gas and vacuum test equipment. b) Examine cooling & heat regeneration performance of the cold trap purification. c) Test the ALIP pump at voltages beyond 120V to see if the targeted mass flow rate of 1.75 kg/s can be obtained in the RxSim. Testing Highlights: a) Gas and vacuum ground support test equipment performed effectively for operations (NaK fill, loop pressurization, and NaK drain). b) Instrumentation & Control system effectively controlled loop temperature and flow rates or pump voltage to targeted settings and ramped within prescribed constraints. It effectively interacted with reactor simulator control model and defaulted back to temperature control mode if the transient fluctuations didn't dampen. c) Cold trap design was able to obtain the targeted cold temperature of 480 K. An outlet temperature of 636 K was obtained which was lower than the predicted 750 K but 156 K higher than the minimum temperature indicating the design provided some heat regeneration. d) ALIP produce a maximum flow rate of 1.53 kg/s at 800 K when operated at 150 V and 53 Hz.
Abstract Geothermal energy plays a vital role in decarbonizing electricity and heat supply. Effective utilization of geothermal resources hinges on identifying or generating permeable reservoir zones and understanding how effective pressure variations affect fluid circulation and reservoir properties by poroelastic deformation. Hydrothermal alteration can modify the petrophysical properties of geothermal reservoir rocks, which may increase or decrease its productivity. Understanding these alteration effects is essential to predict and optimize long‐term sustainable geothermal operations. Here, we investigate the impact of hydrothermal alteration on poroelastic and hydraulic properties of diverse lithologies in a series of deformation tests performed at several confining (0–80 MPa) and pore pressure (10–30 MPa) levels. Experimental results of hydrothermally altered dikes and phyllites obtained from the Blue Mountain geothermal field (Nevada, USA) are compared to thermally cracked La Peyratte granite (France) and correlated with petrophysical properties, mineral composition, and microstructures. Argillic alteration of dikes increases porosity and storage capacity but lowers thermal conductivity and increases pore compressibility. Conversely, silicate precipitation in phyllites increases stiffness and thermal conductivity but also reduces porosity and permeability. Experimentally determined effective pressure coefficients range from 0.1 to 0.9, differ for permeability and volumetric strain and decrease with increasing effective pressure. The presence of compliant microcracks and crack‐like pores significantly increases the stress sensitivity of La Peyratte granite and silicified phyllites. This study demonstrates how thermal and chemical alteration impacts poromechanical and petrophysical characteristics of geothermal targets, which ultimately govern reservoir stability and subsidence, induced seismicity as well as fluid and heat extraction efficiency during geothermal operations.
Efficient thermal energy storage is pivotal to lowering the levelized cost of electricity (LCOE) for Concentrating Solar Power (CSP) plants. In solid-particle systems, however, prolonged high-temperature service degrades particle solar absorptivity, eroding overall efficiency. This project demonstrates a hydrogen-assisted recovery process that reliably restores absorptivity to >90 %, offering a practical route to sustain long-term CSP performance. Bench-scale investigations mapped the reduction kinetics of optically faded particles across hydrogen concentrations, temperatures, and residence times. Coupling mass-spectrometric monitoring with machine-learning optimization minimized energy demand while maximizing absorptivity gain. The resulting process window—moderate hydrogen partial pressures, 15–30 min dwell times, and temperatures well below initial calcination levels—cuts energy consumption well below that of incumbent re-blackening methods. A prototype recovery reactor processed multiple 2 kg batches with repeatable outcomes, confirming scalability and operational robustness. Integrated techno-economic analysis indicates material and operating cost reductions exceeding 15 % relative to conventional particle replacement or chemical re-coating, translating directly into lower LCOE for next-generation CSP facilities. By uniting fundamental reaction-kinetics insight with pragmatic engineering, this work advances the solid-particle pathway, delivering a cost-effective, field-deployable solution to one of CSP’s key durability challenges and strengthening the commercial outlook for high-temperature renewable power.
The opposed-piston two-stroke (OP2S) engine is a promising alternative powertrain technology that can offer thermal and brake efficiency improvements over conventional four-stroke engines. In recent years, many of the technical barriers of the OP2S engine architecture have been overcome. However, there is still a need for fundamental studies to provide insight into the scavenging and combustion processes of the OP2S engine to help design and operate the most efficient combustion systems using this engine architecture. This work aims to provide such insights by analyzing experimental data collected on a 3-cylinder, 4.9 L OP2S engine. Specifically, a scavenging efficiency sweep, an engine speed sweep with a constant scavenging efficiency, and an engine speed with a constant pressure differential across the engine were studied in detail. It was found that in diesel combustion, as the scavenging efficiency decreased, the increase in temperature of the hot, internal residuals resulted in a significant increase in heat transfer. Despite lowering pumping losses, this resulted in an overall decrease in brake efficiency. When the bulk thermodynamic conditions of two different scavenging efficiency cases (67% and 72%) were matched at port closing, the lower scavenging efficiency case still displayed a 0.7 percentage point penalty in net thermal efficiency and an increase in engine-out indicated specific emissions of NOx of 18% due to residual stratification in the cylinder. The results presented in this work show that the optimal breathing strategy in diesel combustion on an OP2S engine architecture is one that results in a slightly under-scavenged environment at port closing. However, the results did show potential system-level efficiency benefits of decreasing scavenging efficiency, meaning that alternative fuels and combustion strategies without the constraints of diesel combustion could achieve system-level efficiency gains by running significantly under-scavenged.
As a promising scenario for fusion reactors, the high poloidal-beta (β P ) scenario is characterized by a strong large radius internal transport barrier (ITB), which significantly enhances the overall confinement quality and the bootstrap current fraction for fully non-inductive operation. It is frequently observed that in the presence of a strong ITB, the pedestal height is lower and is accompanied by small edge localized modes (ELMs), which further improves the compatibility of a high performance core with an edge solution. A mechanism for the formation of the low pedestal is proposed in this paper. It is found that the strong ITB creates an off-axis bootstrap current to clamp the local safety factor q, and thus the magnetic shear in the outer core/pedestal region is increased. Gyrokinetic simulations with the CGYRO code show that the higher magnetic shear brings the experimental profiles into the range where the growth rate of drift-wave instabilities and thus transport is higher, and therefore a lower pedestal gradient is expected. Here, the combination of low pedestal and high magnetic shear further enhances the turbulent transport across the whole pedestal, consistent with power balance analysis. Such a positive feedback mechanism ultimately results in a lower pressure pedestal as observed in experiments. Under such a low pedestal, linear simulations with BOUT++ predict the growth rates of peeling–ballooning modes to be lower across the whole toroidal mode number spectra, and the nonlinear BOUT++ simulation exhibits lower saturated fluctuation intensity as well, consistent with the experimentally observed lower ELM size.
The new DOE-NE Center of Excellence for Thermal-fluids applications in Nuclear Energy inaugurated in April 2018 considers and researches novel new solution strategies for historically challenging flow issues that still plague the current fleet of deployed Light Water nuclear Reactors (LWRs) as well as predicting various fluid flow and fluid related issues with advanced reactor technologies. Our advanced thermal-fluids research and development approach synergistically combines three natural, though overlapping, length and time scales in a hierarchal multi-scale approach to avoid the temptation and pitfalls of attempting to develop a single solve-all algorithm for physical fluid flow problems that will span nine orders of magnitude in spatial and temporal scales. To demonstrate the multi-scale philosophy of the center we focus on Fluoride Cooled High Temperature Reactors (FHRs), and in particular on the Berkley’s PB-FHR Mark-I design. The Fluoride salt cooled High temperature Reactor (FHR) is a class of advanced nuclear reactors that combine the robust coated particle fuel form from high temperature gas cooled reactors, direct reactor auxiliary cooling system (DRACS) passive decay removal of liquid metal fast reactors, and the transparent, high volumetric heat capacitance liquid Fluoride salt working fluids - such as Flibe - from molten salt reactors. This combination of fuel and coolant enables FHRs to operate in a high-temperature low-pressure design space that has beneficial safety and economic implications. The PB-FHR reactor relies on a pebble bed approach and pebble bed reactors are in a sense the poster child for multi-scale analysis. The lower length-scale simulator for pebble reactor cores comprises three physics: neutronics (OpenMC), thermal-fluids (Nek5000/NekRS) and fuel performance (BISON). As part of Center of Excellence ongoing research efforts we have developed Cardinal, a new tool platform for lower length-scale simulation. Cardinal tightly couples all three physics and leverages advances in MOOSE such as the MultiApp system and the concept of MOOSE-wrapped Apps. The present report provides an update on the development of Cardinal with an extension of Cardinal to GPUs. We also perform a first-of-a-kind demonstration simulation on Summit representing a 10x capability increase in terms of pebble count for Cardinal.
Currently, the 8-Foot High Temperature Tunnel (8-Ft. HTT) combustor produces a good profile at only one point (2000 psia and 3650 R with oxygen enrichment). Air is enriched with oxygen (liquid) so that the combustor product gas will contain the volumetric amount of oxygen normally found in air. The oxygen enriched air has a large fraction that is not reacted and flows through the outer periphery of the fuel injector. This ring of cold air in addition to the relatively cold walls of the combustor set up buoyancy forces that produce a segregation of relatively cool gases at the bottom of the combustor exit. The basic problem is to produce a test gas that has uniform properties at all combustor conditions. The combustor temperature may be as high as 3700 R or as low as 2000 R. Combustor pressures can be as high as 3500 psia (no oxygen enrichment) and as low as 600 psia. The segregation is most severe with oxygen enriched air, since its temperature is lower and its density is high. The combustor is lined with nickel 201 and can be operated at about 1600 R maximum. A global mixing process is desired that produces an acceptable profile of temperature, species, and velocity at the exit of the combustor. The ultimate goal is a temperature profile with about 100 R variance and about 2 percent variance in oxygen. The exit total temperature must not be lowered significantly by the mixing apparatus or mechanisms employed. If immersed bodies are used, they must also be kept very hot. All combustor wall modifications must be able to survive the heat and structural conditions of the varied operating conditions. Our approach to resolving this issue is being conducted in three stages: (1) Consider mixing exclusively, (2) Resolve the heat transfer concerns resulting from the chosen mixing strategy, and (3) Solve the material and structural problems resulting from stages (1) and (2). Since the 8-Ft. HTT is unavailable for experimentation, the study is conducted exclusively with computational fluid dynamic (CPD) codes (Fluent/Uns and Rampant 3.1) using unstructured grid through body fitted coordinates. Both CFD codes are general purpose Navier-Stokes solution packages that can solve integral conservation equations for conservation of mass, momentum and energy. The governing equations are discretized using a control-volume finite-element method on unstructured triangular 2-D grids. In the interest of time, a 3-D tetrahedral grid was used to check the 2-D results on one mixing strategy and the 2-D results were confirmed. Preliminary results indicate that excellent mixing can be achieved with a body placed in the center of the flowing hot fluid with a minor modification to the combustor wall similar to a model positioned in the test section of a wind tunnel. The concept here, is to create longitudinal vortices strong enough to bring both fluids into intimate contact with each other near the wall where the cold fluid resides. However, there may be a trade-off in the choice of mixing strategy, heat transfer and structural requirements. Currently, we are examining the more promising geometries for heat transfer concerns and developing strategies for the material of construction of the center body.
Historical data on Antarctic sea ice extent and concentration have traditionally been derived from visible and near-infrared images acquired by the polar-orbiting National Oceanic and Atmospheric Agency's (NOAA) meteorological satellites, using the Advanced Very High Resolution Radiometer (AVHRR), and more recently by the Defense Meteorological Satellite Program's Operational Linescan System (OLS). The limitation of these systems is that the majority of energy imparted to the Antarctic sea-ice system is transferred during b6y fast-moving low pressure systems. Since the Southern Ocean sea-ice cover is completely bounded at its lower latitude limit by open ocean, these "polar lows" transport large amounts of moisture (contained in warm air masses) over the outer ice cover. The result is that most, if not all, noteworthy periods of wind- and temperature-driven dynamic changes in the ice cover are accompanied by periods where the region is blanketed by cloud, and when the atmosphere is inherently more electromagnetically opaque. During storms, the probability with which the area is cloud covered is extremely high, thereby ruling out use of visible or near-infrared images as a practical method of monitoring the associated changes in ice conditions. Instead, Nimbus-7 Scanning Multichannel Microwave Radiometer (SMMR) and DMSP Special Sensor Microwave/imager (SSM/I) have been the primary workhorses to build up a microwave record of Antarctic sea-ice characteristics. Similar problems, however, occur in passive microwave retrievals of sea-ice concentration, and the algorithms are called into question during these periods of change. The influence of water vapor in the atmosphere alone can modify the ice concentration retrievals by fractions exceeding 105, and that retrievals of ice concentration must compensate for the atmospheric water vapor and liquid water contents.
The possibility of North Atlantic Deep Water (NADW) changes in both past and future climates has raised the issue of how the Southern Ocean would respond. Recent experiments with the GISS coupled atmosphere-ocean model have shown that a "bipolar see-saw" between NADW production and Antarctic Bottom Water (AABW) production in the Weddell Sea can occur in conjunction with freshening of the North Atlantic. However, this effect operates not through a slow ocean response but via a rapid atmospheric mechanism. As NADW reduces, colder temperatures in the North Atlantic, and Northern Hemisphere in general, are associated with higher surface pressure (increased atmospheric mass). Reduced mass in the Southern Hemisphere occurs in response, with lower pressure over the South Pole (an EOF #1 effect, the "high phase" of the Antarctic Oscillation).The lower pressure is associated with stronger west winds that generate an intensified Antarctic Circumpolar Current (ACC), which leads to longitudinal heat divergence in the South Atlantic (and heat convergence in the Southern Indian Ocean). Colder temperatures in the Weddell Sea region lead to sea ice growth, increased salinity and surface water density, and greater Weddell Sea Bottom Water production. Increased poleward transport of heat occurs in the South Atlantic in conjunction with increased bottom water production, but its convergence at high latitudes is not sufficient to offset the longitudinal heat divergence due to the intensified ACC. The colder temperatures at high latitudes in the South Atlantic increase the latitudinal temperature gradient, baroclinic instability, eddy energy and eddy poleward transport of momentum, helping to maintain the lower pressure over the pole in an interactive manner. The heat flux convergence in the Indian Ocean provides a warming tendency in that region, and overall global production of AABW remains unchanged. These results have implications for the interpretation of the ice core records of the last deglaciation, but may also be relevant for changes during the Holocene and perhaps even in response to increased CO2 forcing,
This paper describes the heat load sharing function among multiple parallel evaporators in a capillary pumped loop (CPL). In the normal mode of operation, the evaporators cool the instruments by absorbing the waste heat. When an instruments is turned off, the attached evaporator can keep it warm by receiving heat from other evaporators serving the operating instruments. This is referred to as heat load sharing. A theoretical basis of heat load sharing is given first. The fact that the wicks in the powered evaporators will develop capillary pressure to force the generated vapor to flow to cold locations where the pressure is lower leads to the conclusion that heat load sharing is an inherent function of a CPL with multiple evaporators. Heat load sharing has been verified with many CPLs in ground tests. Experimental results of the Capillary Pumped Loop 3 (CAPL 3) Flight Experiment are presented in this paper. Factors that affect the amount of heat being shared are discussed. Some constraints of heat load sharing are also addressed.
Next generation of fuel cells, electrolyzers, and batteries requires higher power, faster kinetics, and larger energy density, which necessitate the use of compositionally complex oxides to achieve multifunctionalities and activity. These compositionally complex oxides may change their phases and structures during an electrochemical process – a so-called “electrochemically driven phase transformation”. The origin for such a phase change has remained obscure. More importantly, there is a need to develop high performance solid oxide fuel cells with an enhanced stability. In this work, the La 0.6 Sr 0.4 Co 0.2 Fe 0.8 O 3 (LSCF) cathode surface is modified by infiltration of Pr 6 O 11 and the power density at 0.8V and 750 °C is improved by 21%. In addition, by replacing the traditional barrier layer Gd 0.2 Ce 0.8 O 1.9 with mixed conducting Pr 0.1 Gd 0.1 Ce 0.8 O 1.9 , the power density increases by 38%. The different mechanism of promotions was investigated by electrochemical impedance spectroscopy. The ohmic resistance is dramatically reduced by applying the PGCO interlayer, and the distribution of relaxation time was used to analyze the mechanism for which the polarization resistance was decreased attributing to the mixed conduction nature in PrO x . An increase of power density at 0.8 V of 0.358 W/cm 2 (71%) is achieved with the implementation of both surface modification and buffer layer engineering. An experimental study and a theoretical analysis were then carried out on phase evolution in praseodymium nickelates. Nickelate-based electrodes show up to 60× greater phase transformation during operation when compared to thermally annealed ones. Theoretical analysis suggests that the presence of a reduced oxygen partial pressure at the interface between the oxygen electrode and the electrolyte is the origin for the phase change in an oxygen electrode. Guided by the theory, an addition of the electronic conduction in the interface layer leads to the significant suppression of phase change, while improving cell performance and performance stability. When an oxygen electrode is under polarization, the oxygen partial pressure at the interface between the oxygen electrode and the electrolyte is lower than that of incoming oxidant. Under a high polarization, the environment at the aforementioned interface may lead to phase transformation of the oxygen electrode. The local oxygen partial pressure is determined by the transport properties at the interfaces. An addition of the electronic conduction in the interface layer, for instance using (Pr,Gd)-doped ceria to replace Gd-doped ceria, results in improved cell performance and performance stability, while the phase transformation is significantly suppressed. This work provides a fundamental understanding of the origin for phase transformation in oxygen electrodes during operation and use this knowledge to develop a high-performance electrode that exhibits improved performance stability.
This study implements the proprietary machine learning-based model (model) developed under the 2022 study titled “Evaluating the Impact of Proprietary Oil & Gas Data on Machine Learning Model Performance Using a Quasi-Experimental Analytical Approach” for forecasting unconventional oil and gas production using well data from the Permian Basin. The model, developed using an exclusive dataset that includes time series production data from an operator in the Permian Basin, is designed to jointly predict daily oil, gas, and water production for horizontal wells as a function of bottomhole pressure drawdown, spatial placement across the study domain, and well-completion attributes. In this study, the model was explicitly applied to explore its utility to evaluate the impact of varying drawdown strategies on the production forecast of a well in the Permian Basin dataset. Managing pressure drawdown has been identified as a way to improve estimated ultimate recovery (EUR) from unconventional shale wells due to the stress-dependent nature of fractures in shale reservoirs. Research has shown that applying a lower pressure drawdown helps to maintain the reservoir conductivity, resulting in higher productivity over the life of a well. Historic bottomhole pressure data from the well over time was used as a benchmark from which to set more and less aggressive pressure decline rates as bounding modeling cases. All pressure decline rates/strategies were forecasted over 5 years, and the model was used to generate oil, water, and gas prediction over the same timeframe. This report presents the results from the production forecast and discusses potential operational and economic implications, with contrasting perspectives between well productivity and profitability given typical oil and gas economics and the volatility in the oil and gas market.
Cycle studies have shown the benefits of increasing engine pressure ratios and cycle temperatures to decrease engine weight and improve performance in next generation turbine engines. Advanced seals have been identified as critical in meeting engine goals for specific fuel consumption, thrust-to-weight, emissions, durability and operating costs. NASA and the industry are identifying and developing engine and sealing technologies that will result in dramatic improvements and address the goals for engines entering service in the 2005-2007 time frame. This paper provides an overview of advanced seal technology requirements and highlights the results of a preliminary design effort to implement advanced seals into a regional aircraft turbine engine. This study examines in great detail the benefits of applying advanced seals in the high pressure turbine region of the engine. Low leakage film-riding seals can cut in half the estimated 4% cycle air currently used to purge the high pressure turbine cavities. These savings can be applied in one of several ways. Holding rotor inlet temperature (RIT) constant the engine specific fuel consumption can be reduced 0.9%, or thrust could be increased 2.5%, or mission fuel burn could be reduced 1.3%. Alternatively, RIT could be lowered 20 'F resulting in a 50% increase in turbine blade life reducing overall regional aircraft maintenance and fuel bum direct operating costs by nearly 1%. Thermal, structural, secondary-air systems, safety (seal failure and effect), and emissions analyses have shown the proposed design is feasible.