Search NASA⌕ Search

SEARCH · Search NASA

Results for “battery voltage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Impact of Charge Methodology Upon the Performance of Lithium Ion Cells

This viewgraph gives an overview on the impact of charge methodology upon the performance of lithium ion cells. Charge characteristics are given on the following: (1) lithium ion prototype cells, including charge rate characteristics at different temperatures, the effect of charge methodology upon cycle life performance, the effect of charge voltage upon cell performance; (2) three-electrode cells; and (3) lithium-ion eight-cell batteries.

Smart, M. C.↗

Impact of Charge Methodology upon the Performance of Lithium Ion Cells

This viewgraph gives an overview on the impact of charge methodology upon the performance of lithium ion cells. Charge characteristics are given on the following: (1) lithium ion prototype cells, including charge rate characteristics at different temperatures, the effect of charge methodology upon cycle life performance, the effect of charge voltage upon cell performance; (2) three-electrode cells; and (3) lithium-ion eight-cell batteries.

lithium ion cells↗

Microfluidic Devices for Chemical and Biochemical Analysis in Microgravity

One often touted benefit of "Lab-on-a-Chip" devices is their potential for use in remote environments. The ultimate remote environment is outer space, and NASA has multiple needs in the area of analytical sensing capability in such an environment. In particular, we are interested in integrating microfluidic devices with NASA bioreactor systems. In such an integrated system, the microfluidic device will serve as a biosensor and be used for both feedback control and for detecting various bioproducts produced by cells cultured in the NASA bioreactors. As a first step in demonstrating the ability of microfluidic devices to operate under the extreme environmental conditions found in outer space, we constructed a portable, battery operated platform for testing under reduced gravity conditions on a NASA KC-135 reduced gravity research aircraft, (AKA "the vomit comet"). The test platform consisted of a microchip, two 0-8kV high voltage power supplies, a high voltage switch, a solid-state diode-pumped green laser, a channel photomultiplier, and an inertial mass measurement unit, all under the control of a laptop computer and powered by 10 D-cell alkaline batteries. Over the course of 4 KC-135 flights, 1817 fast electrophoretic separations of 4 amino acids and/or proteins were performed in a variety of gravitational environments including zero-G, Martian-G, lunar-G, and 2-G. Results from these experiments will be presented and discussed.

Roman, Gregory T.↗

Air Force nickel-hydrogen experiment

An experiment to obtain some flight experience with a nickel-hydrogen battery in low earth orbit is described. The battery was built to be as compatible with the satellite bus as possible because the satellite bus is used for recharge power. The battery is mounted on an experimental pallet on the satellite. It has its own charge control system, a modification of an existing system that is used for nickel-cadmium, which primarily uses temperature compensated voltage as its criteria. Also, on the pallet is a load bank, a resistive load band, which allows switch to various load regimes. There is some other equipment on the satellite such as the nickel-hydrogen battery to power it. Monitors attached to the 21-cell battery are described.

Harsch, B.↗

Battery-package design provides for cell cooling and constraint

Lightweight battery-package provides for even cooling of individual alkaline cells, constraint against cell expansion, and convenient placement of cells. The battery package also provides for venting of the cells and includes instrumentation to measure cell temperature, pressure, and voltage.

Gross, S.↗

Compact reconditioner for Ni/Cd cells

Extension of life of multiple-cell nickel-cadium battery packs is accomplished by reconditioning method requiring discharge of each battery cell. Compact and lightweight dc-to-dc converter replaces relay-sensor system, protecting against voltage-reversal damage, and monitors overall cell condition.

Kapustka, R. E.↗

Cycle life characteristics of sealed silver-zinc cell with inorganic separator

Two batteries containing 18 cells have been cycling in a simulated synchronous (24-hour) orbit for over a year at 40% depth of discharge at 22 C. One battery is under individual cell monitoring and control and the other battery is controlled at the battery level. The battery with individual cell monitoring and protection has performed over 350 cycles with no sign of failure. The battery without individual cell protection failed at 270 cycles from failure to remain above the specified minimum discharge voltage. A significant conclusion is that the sealed Ag-Zn cells manufactured with the inorganic separator material have demonstrated their capability to cycle at a fairly high depth of discharge and are worthy of consideration in short life synchronous orbit applications.

Lear, J. W.↗

Prototype Lithium-Ion Battery Developed for Mars 2001 Lander

In fiscal year 1997, NASA, the Jet Propulsion Laboratory, and the U.S. Air Force established a joint program to competitively develop high-power, rechargeable lithium-ion battery technology for aerospace applications. The goal was to address Department of Defense and NASA requirements not met by commercial battery developments. Under this program, contracts have been awarded to Yardney Technical Products, Eagle- Picher Technologies, LLC, BlueStar Advanced Technology Corporation, and SAFT America, Inc., to develop cylindrical and prismatic cell and battery systems for a variety of NASA and U.S. Air Force applications. The battery systems being developed range from low-capacity (7 to 20 A-hr) and low-voltage (14 to 28 V) systems for planetary landers and rovers to systems for aircraft that require up to 270 V and for Unmanned Aerial Vehicles that require capacities up to 200 A-hr. Low-Earth-orbit and geosynchronousorbit spacecraft pose additional challenges to system operation with long cycle life (>30,000 cycles) and long calendar life (>10 years), respectively.

Manzo, Michelle A.↗

Performance of High Voltage Modules Under Abuse Operations

The Electric Auxiliary Power Unit (EAPU) or the Advanced Hydraulic Power System (AHPS) is a Shuttle Upgrade program. Of the two battery design approaches that were considered in support of this program, the current paper concentrates on the testing performed on the small-cell approach. Testing performed at both ComDev Space, Canada and at NASA-JSC is described in this paper. Testing included those under mission profile conditions and off-nominal abusive conditions.

Jeevarajan, Judith A.↗

Practical aspects of photovoltaic technology, applications and cost (revised)

The purpose of this text is to provide the reader with the background, understanding, and computational tools needed to master the practical aspects of photovoltaic (PV) technology, application, and cost. The focus is on stand-alone, silicon solar cell, flat-plate systems in the range of 1 to 25 kWh/day output. Technology topics covered include operation and performance of each of the major system components (e.g., modules, array, battery, regulators, controls, and instrumentation), safety, installation, operation and maintenance, and electrical loads. Application experience and trends are presented. Indices of electrical service performance - reliability, availability, and voltage control - are discussed, and the known service performance of central station electric grid, diesel-generator, and PV stand-alone systems are compared. PV system sizing methods are reviewed and compared, and a procedure for rapid sizing is described and illustrated by the use of several sample cases. The rapid sizing procedure yields an array and battery size that corresponds to a minimum cost system for a given load requirement, insulation condition, and desired level of service performance. PV system capital cost and levelized energy cost are derived as functions of service performance and insulation. Estimates of future trends in PV system costs are made.

Rosenblum, L.↗

Development and Testing of an Ultracapacitor Based Uninterruptible Power Supply (UPS) System

The NASA Glenn Research Center (GRC) initiated the development and testing of an ultracapacitor based uninterruptible power supply (UPS) system as a means to provide backup power for the many critical NASA applications. A UPS system typically utilizes batteries for energy storage. The battery is the most vulnerable part of the UPS system, requiring regular maintenance and replacement. Battery performance is also extremely temperature dependent. Ultracapacitors are ideal for UPS systems where long life, maintenance free operation, and excellent low temperature performance is essential. State of the art symmetric ultracapacitors were used for these tests. The ultracapacitors were interconnected in an innovative configuration to minimize interconnection impedance, and to provide voltage balancing. Ultracapacitors can be charged extremely rapidly and supply high current, which are essential characteristics for an effective UPS system. Charging ultracapacitors is significantly less complex than charging batteries since there is no chemical reaction occurring while charging ultracapacitors. The report concludes that the implementation of symmetric ultracapacitors in a UPS system can provide significant improvements in power system performance and reliability.

Eichenberg, Dennis J.↗

Development of single cell protectors for sealed silver-zinc cells, phase 1

A single cell protector (SCP) assembly capable of protecting a single silver-zinc (Ag Zn) battery cell was designed, fabricated, and tested. The SCP provides cell-level protection against overcharge and overdischarge by a bypass circuit. The bypass circuit consists of a magnetic-latching relay that is controlled by the high and low-voltage limit comparators. Although designed specifically for secondary Ag-Zn cells, the SCP is flexible enough to be adapted to other rechargeable cells. Eighteen SCPs were used in life testing of an 18-cell battery. The cells were sealed Ag-Zn system with inorganic separators. For comparison, another 18-cell battery was subjected to identical life test conditions, but with battery-level protection rather than cell-level. An alternative approach to the SCP design in the form of a microprocessor-based system was conceptually designed. The comparison of SCP and microprocessor approaches is also presented and a preferred approach for Ag-Zn battery protection is discussed.

Imamura, M. S.↗

Lithium cell tests at Langley Research Center

The long duration exposure facility mission places temperature requirements of from -30 F to +150 F on the batteries to be used. A hermetically sealed lithium sulfur dioxide cell was tested to predict what the temperature of the battery would be over a given spectrum of temperatures of operation. Near the end of cell discharge, as the voltage started collapsing, a very high heat output rise due to chemical reaction took place. However, if the cells were thermally insulated, they vented, ignited, and burned if an attempt was made to discharge them all the way. The cells do not go into reversal. It was determined that the root of the problem was probably the chemical reaction between the lithium and the acetonitrite solvent. A redesigned cell is discussed as well as some alternates.

Bene, J.↗

OAO-3 end of mission power subsystem evaluation

End of mission tests were performed on the OAO-3 power subsystem in three component areas: solar array, nickel-cadmium batteries and the On-Board Processor (OBP) power boost operation. Solar array evaluation consisted of analyzing array performance characteristics and comparing them to earlier flight data. Measured solar array degradation of 14.1 to 17.7% after 8 1/3 years is in good agreement with theortical radiation damage losses. Battery discharge characteristics were compared to results of laboratory life cycle tests performed on similar cells. Comparison of cell voltage profils reveals close correlation and confirms the validity of real time life cycle simulation. The successful operation of the system in the OBP/power boost regulation mode demonstrates the excellent life, reliability and greater system utilization of power subsystems using maximum power trackers.

Tasevoli, M.↗

New Lithium-ion Polymer Battery for the Extravehicular Mobility Unit Suit

The Extravehicular Mobility Unit (EMU) suit currently has a silver-zinc battery that is 20.5 V and 45 Ah capacity. The EMU's portable life support system (PLSS) will draw power from the battery during the entire period of an EVA. Due to the disadvantages of using the silver-zinc battery in terms of cost and performance, a new high energy density battery is being developed for future use, The new battery (Lithium-ion battery or LIB) will consist of Li-ion polymer cells that will provide power to the EMU suit. The battery design consists of five 8 Ah cells in parallel to form a single module of 40 Ah and five such modules will be placed in series to give a 20.5 V, 40 Ah battery. Charging will be accomplished on the Shuttle or Station using the new LIB charger or the existing ALPS (Air Lock Power Supply) charger. The LIB delivers a maximum of 3.8 A on the average, for seven continuous hours, at voltages ranging from 20.5 V to 16.0 V and it should be capable of supporting transient pulses during start up and once every hour to support PLSS fan and pump operation. Figure 1 shows the placement of the battery in the backpack area of the EMU suit. The battery and cells will undergo testing under different conditions to understand its performance and safety characteristics.

Jeevarajan, J. A.↗

Controllers for Battery Chargers and Battery Chargers Therefrom

A controller for a battery charger that includes a power converter has parametric sensors for providing a sensed Vin signal, a sensed Vout signal and a sensed Iout signal. A battery current regulator (BCR) is coupled to receive the sensed Iout signal and an Iout reference, and outputs a first duty cycle control signal. An input voltage regulator (IVR) receives the sensed Vin signal and a Vin reference. The IVR provides a second duty cycle control signal. A processor receives the sensed Iout signal and utilizes a Maximum Power Point Tracking (MPPT) algorithm, and provides the Vin reference to the IVR. A selection block forwards one of the first and second duty cycle control signals as a duty cycle control signal to the power converter. Dynamic switching between the first and second duty cycle control signals maximizes the power delivered to the battery.

Elmes, John↗

Principles for system level electrochemistry

The higher power and higher voltage levels anticipated for future space missions have required a careful review of the techniques currently in use to preclude battery problems that are related to the dispersion characteristics of the individual cells. Not only are the out-of-balance problems accentuated in these larger systems, but the thermal management considerations also require a greater degree of accurate design. Newer concepts which employ active cooling techniques are being developed which permit higher rates of discharge and tighter packing densities for the electrochemical components. This paper will put forward six semi-independent principles relating to battery systems. These principles will progressively address cell, battery and finally system related aspects of large electrochemical storage systems.

Thaller, L. H.↗

Voltage-temperature charge verification testing of 34 ampere-hour nickel-cadmium cells

This testing was designed to evaluate various voltage-temperature (V-T) charge curves for use in low-Earth-orbit (LEO) applications of nickel-cadmium battery cells. The trends established relating V-T level to utilizable capacity were unexpected. The trends toward lower capacity at higher V-T levels was predominant in this testing. This effect was a function of the V-T level, the temperature, and the cell history. This effect was attributed to changes occurring in the positive plate. The results imply that for some applications, the use of even lower V-T levels may be warranted. The need to limit overcharge, especially in the early phases of missions, is underlined by this test program.

Timmerman, P. J.↗