Search NASA⌕ Search

SEARCH · Search NASA

Results for “camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Airborne ballistic camera tracking systems

An operational airborne ballistic camera tracking system was tested for operational and data reduction feasibility. The acquisition and data processing requirements of the system are discussed. Suggestions for future improvements are also noted. A description of the data reduction mathematics is outlined. Results from a successful reentry test mission are tabulated. The test mission indicated that airborne ballistic camera tracking systems are feasible.

Redish, W. L.↗

Solid State Television Camera (CID)

The design, development and test are described of a charge injection device (CID) camera using a 244x248 element array. A number of video signal processing functions are included which maximize the output video dynamic range while retaining the inherently good resolution response of the CID. Some of the unique features of the camera are: low light level performance, high S/N ratio, antiblooming, geometric distortion, sequential scanning and AGC.

Steele, D. W.↗

A spectral reflectance estimation technique using multispectral data from the Viking lander camera

A technique is formulated for constructing spectral reflectance curve estimates from multispectral data obtained with the Viking lander camera. The multispectral data are limited to six spectral channels in the wavelength range from 0.4 to 1.1 micrometers and most of these channels exhibit appreciable out-of-band response. The output of each channel is expressed as a linear (integral) function of the (known) solar irradiance, atmospheric transmittance, and camera spectral responsivity and the (unknown) spectral responsivity and the (unknown) spectral reflectance. This produces six equations which are used to determine the coefficients in a representation of the spectral reflectance as a linear combination of known basis functions. Natural cubic spline reflectance estimates are produced for a variety of materials that can be reasonably expected to occur on Mars. In each case the dominant reflectance features are accurately reproduced, but small period features are lost due to the limited number of channels. This technique may be a valuable aid in selecting the number of spectral channels and their responsivity shapes when designing a multispectral imaging system.

Park, S. K.↗

Engineering design criteria for an image intensifier/image converter camera

The design, display, and evaluation of an image intensifier/image converter camera which can be utilized in various requirements of spaceshuttle experiments are described. An image intensifier tube was utilized in combination with two brassboards as power supply and used for evaluation of night photography in the field. Pictures were obtained showing field details which would have been undistinguishable to the naked eye or to an ordinary camera.

Sharpsteen, J. T.↗

Space telescope optical telescope assembly/scientific instruments. Phase B: -Preliminary design and program definition study; Volume 2A: Planetary camera report

Development of the F/48, F/96 Planetary Camera for the Large Space Telescope is discussed. Instrument characteristics, optical design, and CCD camera submodule thermal design are considered along with structural subsystem and thermal control subsystem. Weight, electrical subsystem, and support equipment requirements are also included.

Source record↗

Television cameras employing solid-state imaging sensors for manned spacecraft applications

The Space Shuttle television system incorporates a versatile complement of TV equipment which allows the positioning, quantity, and performance capabilities of the multiple TV cameras to vary as dictated by the particular mission. However, current TV camera technology employing glass enclosed, vacuum processed image sensors results in a bulky device that restricts its location and versatility. Problems and potential solutions that can be achieved through the employment of solid-state image sensors for both monochrome and color applications are discussed.

Embrey, B. C., Jr.↗

RECON 6: A real-time, wide-angle, solid-state reconnaissance camera system for high-speed, low-altitude aircraft

The maturity of self-scanned, solid-state, multielement photosensors makes the realization of "real time" reconnaissance photography viable and practical. A system built around these sensors which can be constructed to satisfy the requirements of the tactical reconnaissance scenario is described. The concept chosen is the push broom strip camera system -- RECON 6 -- which represents the least complex and most economical approach for an electronic camera capable of providing a high level of performance over a 140 deg wide, continuous swath at altitudes from 200 to 3,000 feet and at minimum loss in resolution at higher altitudes.

Labinger, R. L.↗

Development of a drive system for a sequential space camera contract modification 4(S)

The brush type dc motor and clutch were eliminated from the design of the 16 mm space sequential camera design and replaced by an electronically commutated motor. The new drive system reduces the current consumption at 24 fps to 220 mA. The drive can be programmed and controlled externally from the multipurpose programmable timer/intervalometer, as well as being controlled locally from the camera.

Sharpsteen, J. T.↗

Very-wide-field camera. Proposal of Space Astronomy Laboratory for second Spacelab mission

A proposal is made for inclusion of a very wide field camera onboard Spacelab. Its scientific program is outlined: detection and photometry, spectrography, and star and starlike object photography. The optics, receptor, and mechanical structure are described. Scientific and technical constraints are discussed, and a development plan is detailed. The dust contamination of Spacelab using the camera was also studied.

Courtes, G.↗

Wide angle pinhole camera

Hemispherical refracting element gives pinhole camera 180 degree field-of-view without compromising its simplicity and depth-of-field. Refracting element, located just behind pinhole, bends light coming in from sides so that it falls within image area of film. In contrast to earlier pinhole cameras that used water or other transparent fluids to widen field, this model is not subject to leakage and is easily loaded and unloaded with film. Moreover, by selecting glass with different indices of refraction, field at film plane can be widened or reduced.

Franke, J. M.↗

Return Beam Vidicon (RBV) panchromatic two-camera subsystem for LANDSAT-C

A two-inch Return Beam Vidicon (RBV) panchromatic two camera Subsystem, together with spare components was designed and fabricated for the LANDSAT-C Satellite; the basis for the design was the Landsat 1&2 RBV Camera System. The purpose of the RBV Subsystem is to acquire high resolution pictures of the Earth for a mapping application. Where possible, residual LANDSAT 1 and 2 equipment was utilized.

Source record↗

Viking lander camera radiometry calibration report, volume 2

The requirements the performance validation, and interfaces for the RADCAM program, to convert Viking lander camera image data to radiometric units were established. A proposed algorithm is described, and an appendix summarizing the planned reduction of camera test data was included.

Wolf, M. R.↗

Stereo mapping with the Viking Lander camera imagery

Stereomapping techniques applicable to the processing of imagery from facsimile cameras on board the Viking Mars landing vehicles are discussed. Two methods of stereomapping are considered: use of a gnomonic projection to transform the digital imagery to an equivalent of a perspective projection by computerized rectification through image processing; and interfacing a high-speed digital computer to an analytical plotter so that rectification and corrections proceed in real time. Contour maps produced during tests of the Viking Lander cameras, as well as maps of the area surrounding the Viking Lander on the Martian surface, are presented.

Wu, S. S. C.↗

Near infrared photography with a vacuum-cold camera

Sensitized cooled plates have been obtained of the Orion nebula region and of Sh2-149 in the wavelength ranges 8000 A-9000 A and 9,000 A-11,000 A with a recently designed and constructed vacuum-cold camera. Sensitization procedures are described and the camera design is presented.

Rossano, G. S.↗

Matched tandem etalon camera - MATEC - and its application to auroral observations

The matched tandem etalon camera employs a Fabry-Perot interferometer (FP) in the photographic mode for the spatial resolution over all angles up to 7 deg from normal. An interference filter and an appropriate field lens isolate a single order of 0.1 A resolution, which is recorded simultaneously at all angles in the field of view by array detection. Thus the resolution and luminosity of the MATEC camera are those of the FP. The MATEC pilot model has a ratio of free spectral range to linewidth of 400 and utilizes intensified photographic detection. In a system applied to auroral measurements the MATEC views a semiconical sky mirror to provide a simulatenous dimension of spatial resolution in the N-S meridian combined with the dimension of spectral resolution. Stellar features and cloud and ground reflections are more easily identified than by any scanning photometer.

Young, E. R.↗