Search NASA⌕ Search

SEARCH · Search NASA

Results for “capacitance sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Electrostatic capacitance and Faraday cage behavior of carbon nanotube forests

Understanding of the electrostatic properties of carbon nanotube (CNT) forests is essential to enable their integration in microelectronic and micromechanical devices. In this study, we sought to understand how the hierarchical geometry and morphology of CNT forests determines their capacitance. First, we find that at small gaps, solid micropillars have greater capacitance, yet at larger gaps the capacitance of the CNT forests is greater. The surface area of the CNT forest accessible to the electrostatic field was extracted by analysis of the measured capacitance, and, by relating the capacitance to the average density of CNTs in the forest, we find that the penetration depth of the electrostatic field is on the order of several microns. Therefore, CNT forests can behave as a miniature Faraday cage. The unique electrostatic properties of CNT forests could therefore enable their use as long-range proximity sensors and as shielding elements for miniature electronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Exceptional NH 3 Detection by Cu(cyhdc) MOF Sensor Due to H 2 O Coadsorption

Metal–organic framework (MOF)-based electrical impedance sensors are a growing class of sensors that show utility in the detection of environmentally toxic gases. Detection of trace NH 3 has been particularly difficult to design due to the low electrical response of NH 3 . However, this has been circumvented by judiciously selecting a MOF that has enhanced electrical response to NH 3 due to coadsorption with predominant atmospheric gases such as water. Herein, an MOF Cu(cyhdc) based sensor has been successfully demonstrated for the enhanced detection of environmentally toxic NH 3 gas. The sensor shows a change in impedance when it is exposed to 5 ppm of NH 3 . At 20 °C, >30% relative humidity (RH) is necessary to elicit a change, with the response increasing with RH and reaching 3170× at 92% RH, producing the largest published response to NH 3 for a MOF direct electrical sensor. In the absence of water, no change is observed toward 5 ppm of NH 3 over 20–50 °C. Here, this electrical response is largely driven by huge decreases in the imaginary component of the impedance, attributed to increased capacitance at the surface of the MOF crystallites upon NH 3 and H 2 O coadsorption. Complementary structural and microstructural characterization proves that the Cu(cyhdc) crystalline structure and morphology remain intact under trace NH 3 and/or H 2 O adsorption. Despite extremely low NH 3 , loadings seen in TGA, XPS, and FT-IR confirm NH 3 and H 2 O adsorption, and changes to the metal-carboxylate IR peak positions are observed upon NH 3 adsorption. Concentrated primarily at the outer surfaces of the MOF crystallites, this NH 3 and H 2 O coadsorption effectively increases the surface capacitance across the Cu(cyhdc) powder and enables direct electrical detection of trace NH 3 . Together, these results demonstrate how coadsorption of specific molecules (H 2 O) can be used to enable the electrical detection of trace toxic gases that would otherwise not have produced a MOF sensor response.

ammonia↗

Impedance Spectroscopy, Magnetic and Optical Analysis of Cadmium Tungstate Nanoparticles from Influence of Capping Agent Additives

Nano crystals of cadmium tungstate (CdWO{sub 4}) were obtained by facile precipitation route by using cadmium sulfate octahydrate and sodium tungstate dihydrate. These nanoparticles were then coated using different capping agents such as glucose, polyvinyl alcohol (PVA), and valine and their effects on the particle size, band gap, morphology, and magnetic character were investigated by powder X-ray diffraction, UV-Visible, FESEM, TEM, and VSM analysis. Capping agents are used in the synthesis of nanoparticles since they facilitate the growth and aggregation of particles in a precise manner, by usually acting as a physical barrier which controls the flow of free electron to the catalyst, so that they can be utilized by the catalyst and sensors of nanoparticle. Impedance spectroscopic technique was carried out, which was very useful in separating the grain boundary resistance and grain boundary capacitance contributions. We discuss the utilization of capping agents and their effects, including surface, optical and intergranular potential barriers in this work.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of specimen dimensions and dynamic pressure in dynamic triaxial experiments

Novel experimental techniques are developed to measure the rapid changes in specimen dimensions during dynamic triaxial experiments. A capacitance gage is designed and constructed to measure the diameter change of the specimen inside the pressure chamber at both low and high rates. The length change is determined by a linear variable differential transformer at low rates and by Kolsky bar signals at high rates. The Kolsky bar also measures the dynamic axial stress in the specimen during the high-rate phase of an experiment. A line pressure gage records the hydrostatic pressure in the chamber. The dynamic pressure variation in the chamber during axial impact loading is detected by a manganin gage placed inside the chamber. The feasibility of this new experimental setup is demonstrated by dynamic triaxial experiments on a fine dry sand.

42 ENGINEERING↗

Coupled orbiting inertial reference systems and Geopotential Research Mission (GRM) geodesy

Two spacecraft, one following the other with a separation of a few hundred kilometers and orbiting at an altitude of 160 km in a 90-degree polar orbit, are used to detect the minute variations in the earth's gravitational field. Housed in a capacitive cavity located at the centroid of the spacecraft is a free-floating metallic spherical proof-mass, which is the sensor controlling the thrusters that nullify all nongravitational forces on the spacecraft. The proof-mass in each spacecraft is the inertial-guidance reference for its host spacecraft, and the proof-masses are coupled together by a millimeter-wave link. This coupled system detects minute changes in the spacecraft's orbital positions and thus measures the anomalies present in the gravitational field of the earth. To derive a global geodetic model of the gravitational field with an amplitude resolution of 1 milligal and a spatial resolution of 100 km requires that the relative velocity between the proof-mass references be determined to within 1 micron/s.

Keating, T.↗

Capacitance Probe Resonator for Multichannel Electrometer

A multichannel electrometer voltmeter has been developed that employs a mechanical resonator with voltage-sensing capacitance-probe electrodes that enable high-impedance, high-voltage, radiation-hardened measurement of an Internal Electrostatic Discharge Monitor (IESDM) sensor. The IESDM is new sensor technology targeted for integration into a Space Environmental Monitor (SEM) subsystem used for the characterization and monitoring of deep dielectric charging on spacecraft. The resonator solution relies on a non-contact, voltage-sensing, sinusoidal-varying capacitor to achieve input impedances as high as 10 petaohms as determined by the resonator materials, geometries, cleanliness, and construction. The resonator is designed with one dominant mechanical degree of freedom, so it resonates as a simple harmonic oscillator and because of the linearity of the variable sense capacitor to displacement, generates a pure sinusoidal current signal for a fixed input voltage under measurement. This enables the use of an idealized phase-lock sensing scheme for optimal signal detection in the presence of noise.

Blaes, Brent R.↗

Synthesis of nitrogen and sulfur co-doped yolk-shell porous carbon microspheres and their application for Pb(II) detection in fish serum

Highlights: • N, S-YSPCMS was obtained via simple silica templating and pyrolysis method. • N, S-YSPCMS shows spherical morphology, porous structure and high N, S contents. • N, S-YSPCMS based electrochemical sensor shows good performance in Pb(II) analysis. • N, S-YSPCMS based sensor is feasible in detection of Pb(II) in fish serum. - Abstract: Nitrogen (N) and sulfur (S) co-doped carbonaceous material has shown remarkably improved performance in electrocatalysis, supercapacitor, and so on. While, the application of N, S co-doped carbon in electrochemical sensor was less investigated. Herein, N, S co-doped yolk-shell porous carbon microspheres (N, S-YSPCMSs) were synthesized by silica templating strategy and high-temperature pyrolysis method. The as-prepared N, S-YSPCMSs exhibited spherical morphologies, porous structures and high N, S-doping contents. Owing to the synergetic effect of the well-dispersed N, S-dopants, good conductivity of carbon skeleton, high surface area and pore volume of the microspheres, the N, S-YSPCMSs prepared at 900 °C showed good electrochemical performance for Pb(II) and with a linear range of 4–160 μg L{sup −1}, the limit of detection is 0.49 μg L{sup −1} (S/N = 3). The electrochemical sensor was consequently applied in detecting Pb(II) in fish serum samples with satisfying recoveries, indicating the N, S-YSPCMSs-900 are promising electrode components for electroanalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Additively manufactured strain sensors for in-pile applications

Accurate, real-time monitoring of strain in fuel, cladding, and structural components of nuclear reactors is critical to better understand radiation induced phenomena during reactor tests and operations. The data provided is crucial to verify physics-based, multiscale modeling and simulation efforts, which aim to shorten the timeline for the development of new nuclear materials. Resistive strain gauges have limited performance during in-pile experiments due to the harsh operating conditions and limited physical space between fuel and cladding components. In this work, aerosol jet printing using silver nanoparticle inks was used to fabricate interdigitated electrode capacitive strain gauges on aluminum alloy 6061 tensile specimens. Here to simulate the temperatures of a traditional light water reactor, the capacitive strain gauges were tested with a mechanical test frame up to 300 °C and compared to commercially available bondable resistive strain gauges. The printed capacitive strain gauges exhibited a gauge factor of 1.0 and showed higher reproducibility and predictability of strain sensing performance than the resistive strain gauge. The results demonstrate the potential of aerosol jet printing to fabricate strain sensors with predictable performance and reduced invasiveness for high-temperature applications with confined spacing.

36 MATERIALS SCIENCE↗

Quantum dot ternary-valued full-adder: Logic synthesis by a multiobjective design optimization based on a genetic algorithm

A methodology is proposed for designing a low-energy consuming ternary-valued full adder based on a quantum dot (QD) electrostatically coupled with a single electron transistor operating as a charge sensor. The methodology is based on design optimization: the values of the physical parameters of the system required for implementing the logic operations are optimized using a multiobjective genetic algorithm. The searching space is determined by elements of the capacitance matrix describing the electrostatic couplings in the entire device. The objective functions are defined as the maximal absolute error over actual device logic outputs relative to the ideal truth tables for the sum and the carry-out in base 3. The logic units are implemented on the same device: a single dual-gate quantum dot and a charge sensor. Their physical parameters are optimized to compute either the sum or the carry out outputs and are compatible with current experimental capabilities. The outputs are encoded in the value of the electric current passing through the charge sensor, while the logic inputs are supplied by the voltage levels on the two gate electrodes attached to the QD. The complex logic ternary operations are directly implemented on an extremely simple device, characterized by small sizes and low-energy consumption compared to devices based on switching single-electron transistors. The design methodology is general and provides a rational approach for realizing non-switching logic operations on QD devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

M3AS-25IN1002073: Analysis of data from irradiation testing of printed strain gauges in prototypic nuclear environments

Advancement in additively manufactured strain gauges help address critical technology gaps to accurately monitor real-time materials behavior in reactor experiments. This is critical as it provides data to inform predictive models and simulations that enhance the development of reactors and fuel cycle systems. In this report, additively manufactured strain gauges are exposed to a neutron irradiation environment at the Ohio State University Research Reactor. This report goes over a 2-week campaign for neutron irradiating printed resistive strain gauges and capacitive strain gauges. These results complement the prior separate effects (i.e., mechanical strain, temperature, etc.) testing that were performed on these additive manufactured sensors and presented in prior milestone reports. These results also help progress our understanding of their usage in harsh environment applications. The outcome of developing advanced sensing and instrumentation capabilities plays an important role in increasing the safety, reliability, and energy efficiency of both next-generation and existing nuclear reactors.

36 - MATERIALS SCIENCE↗

Level monitoring system with pulsating sensor—Application to online level monitoring of dashpots in a fast breeder reactor

An innovative continuous type liquid level monitoring system constructed by using a new class of sensor, viz., pulsating sensor, is presented. This device is of industrial grade and it is exclusively used for level monitoring of any non conducting liquid. This instrument of unique design is suitable for high resolution online monitoring of oil level in dashpots of a sodium-cooled fast breeder reactor. The sensing probe is of capacitance type robust probe consisting of a number of rectangular mirror polished stainless steel (SS-304) plates separated with uniform gaps. The performance of this novel instrument has been thoroughly investigated. The precision, sensitivity, response time, and the lowest detection limit in measurement using this device are <0.01 mm, ∼100 Hz/mm, ∼1 s, and ∼0.03 mm, respectively. The influence of temperature on liquid level is studied and the temperature compensation is provided in the instrument. The instrument qualified all recommended tests, such as environmental, electromagnetic interference and electromagnetic compatibility, and seismic tests prior to its deployment in nuclear reactor. With the evolution of this level measurement approach, it is possible to provide dashpot oil level sensors in fast breeder reactor for the first time for continuous measurement of oil level in dashpots of Control and Safety Rod Drive Mechanism during reactor operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A self diagnostic system for piezoelectric sensors

A technique for determining the mounting conditions of a piezoelectric accelerometer is presented. This technique electrically stimulates the piezoelectric element in the 'diagnostic' frequency band measuring the electrical frequency response characteristics across a capacitive load impedance. The diagnostic frequency band is tipically much higher than the operating bandwidth of the accelerometer. The resonant frequencies of the accelerometer are included in the diagnostic band. By monitoring the shift in these resonant frequencies, via electrical stimulation techniques, certain diagnostic conditions including mounting conditions can be determined. Experimental data from a compression mode accelerometer is used to demonstrate this technique.

Atherton, William J.↗

Thin film cadmium telluride charged particle sensors for large area neutron detectors

Thin film semiconductor neutron detectors are an attractive candidate to replace {sup 3}He neutron detectors, due to the possibility of low cost manufacturing and the potential for large areas. Polycrystalline CdTe is found to be an excellent material for thin film charged particle detectors—an integral component of a thin film neutron detector. The devices presented here are characterized in terms of their response to alpha and gamma radiation. Individual alpha particles are detected with an intrinsic efficiency of >80%, while the devices are largely insensitive to gamma rays, which is desirable so that the detector does not give false positive counts from gamma rays. The capacitance-voltage behavior of the devices is studied and correlated to the response due to alpha radiation. When coupled with a boron-based neutron converting material, the CdTe detectors are capable of detecting thermal neutrons.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Silicon bulk micromachined, symmetric, degenerate vibratorygyroscope, accelerometer and sensor and method for using the same

When embodied in a microgyroscope, the invention is comprised of a silicon, four-leaf clover structure with a post attached to the center. The whole structure is suspended by four silicon cantilevers or springs. The device is electrostatically actuated and capacitively detects Coriolis induced motions of the leaves of the leaf clover structure. In the case where the post is not symmetric with the plane of the clover leaves, the device can is usable as an accelerometer. If the post is provided in the shape of a dumb bell or an asymmetric post, the center of gravity is moved out of the plane of clover leaf structure and a hybrid device is provided. When the clover leaf structure is used without a center mass, it performs as a high Q resonator usable as a sensor of any physical phenomena which can be coupled to the resonant performance.

Tang, Tony K.↗

Nonlinear size dependent analysis and effectiveness of nanocrystalline micro/nanogyroscopes

Vibratory micro/nanogyroscopes made of nanocrystalline silicon have a complex microstructure consisting of grains, voids, and interface material phases. Given that the length scale of such inertial sensors is close to the size of the grains themselves, classical continuum mechanics theories are no longer adequate to accurately model the dynamic behaviors of these sensors. In this work, the couple stress and surface elasticity are incorporated to the governing equations of an electrically-actuated, amplitude-based, capacitive sensing cantilever gyroscope to obtain a comprehensive model of the nano-system. Then, the impact of the size dependent effects on the nonlinear dynamic behavior of the gyroscope is investigated by studying its performance for gyroscopes ranging in size from the micro-to the nano-scale. The present numerical study shows that the additional stiffness contributions from the couple stress and surface elasticity and changes in scale cause significant changes in the frequency response, nonlinear behaviors, and sensitivity of the gyroscope to the rotation rates. Furthermore, this numerical analysis demonstrates the importance of accounting for size dependent effects for micro/nanogyroscopes in order to avoid any deterioration of the effectiveness of the gyroscope operability.

42 ENGINEERING↗

Development and Implementation of 3-D, High Speed Capacitance Tomography for Imaging Large-Scale, Cold-Flow Circulating Fluidized Bed

A detailed understanding of multiphase flow behavior inside a Circulating Fluidized Bed (CFB) requires a 3-D technique capable of visualizing the flow field in real-time. Electrical Capacitance Volume Tomography (ECVT) is a newly developed technique that can provide such measurements. The attractiveness of the technique is in its low profile sensors, fast imaging speed and scalability to different section sizes, low operating cost, and safety. Moreover, the flexibility of ECVT sensors enable them to be designed around virtually any geometry, rendering them suitable to be used for measurement of solid flows in exit regions of the CFB. Tech4Imaging LLC has worked under contract with the U.S. Department of Energy's National Energy Technology Laboratory (DOE NETL) to develop an ECVT system for cold flow visualization and install it on a 12 inch ID circulating fluidized bed. The objective of this project was to help advance multi-phase flow science through implementation of an ECVT system on a cold flow model at DOE NETL. This project has responded to multi-phase community and industry needs of developing a tool that can be used to develop flow models, validate computational fluid dynamics simulations, provide detailed real-time feedback of process variables, and provide a comprehensive understating of multi-phase flow behavior. In this project, a complete ECVT system was successfully developed after considering different potential electronics and sensor designs. The system was tested at various flow conditions and with different materials, yielding real-time images of flow interaction in a gas-solid flow system. The system was installed on a 12 inch ID CFB of the US Department of Energy, Morgantown Labs. Technical and economic assessment of Scale-up and Commercialization of ECVT was also conducted. Experiments conducted with larger sensors in conditions similar to industrial settings are very promising. ECVT has also the potential to be developed for imaging multi-phase flow systems in high temperature and high pressure conditions, typical in many industrial applications.

42 ENGINEERING↗

Non-contact current and voltage sensor

A detachable current and voltage sensor provides an isolated and convenient device to measure current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing that contains the current and voltage sensors, which may be a ferrite cylinder with a hall effect sensor disposed in a gap along the circumference to measure current, or alternative a winding provided through the cylinder along its axis and a capacitive plate or wire disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.

47 OTHER INSTRUMENTATION↗

Non-contact current and voltage sensing method using a clamshell housing and a ferrite cylinder

A method of measurement using a detachable current and voltage sensor provides an isolated and convenient technique for to measuring current passing through a conductor such as an AC branch circuit wire, as well as providing an indication of an electrostatic potential on the wire, which can be used to indicate the phase of the voltage on the wire, and optionally a magnitude of the voltage. The device includes a housing that contains the current and voltage sensors, which may be a ferrite cylinder with a hall effect sensor disposed in a gap along the circumference to measure current, or alternative a winding provided through the cylinder along its axis and a capacitive plate or wire disposed adjacent to, or within, the ferrite cylinder to provide the indication of the voltage.

24 POWER TRANSMISSION AND DISTRIBUTION↗