Linking structure to performance: Characterization of porous transport layers for high-pressure water electrolysis

Proton exchange membrane (PEM) water electrolysis is a promising technology to produce cost-efficient hydrogen. PEM electrolyzers offer a large current density range and the ability to operate at differential pressure which can be used to minimize both capital and operational expenditures. However, directly producing pressurized hydrogen at the cathode results in pushing the membrane against the anode porous transport layer (PTL). This can lead to detrimental effects, such as membrane deformation or ruptures, which depend on membrane properties as well as PTL material properties such as pore size, structure, and morphology. In this work, a range of sinter and felt-based commercial PTLs are evaluated for their contributions to the cell's electrochemical and H 2 crossover performance at cathode pressures up to 30 bar. X-ray tomography and post-operando optical microscopy are used to assess the morphology of the PTLs, and the PTL induced deformation experienced by the catalyst coated membrane (CCM), respectively. PTL samples with lower porosity were found to reduce both the cell voltage and the amount of H 2 permeating from the cathode to the anode exhaust, which was ascribed to improved catalyst layer contact and reduced membrane deformation, respectively. The best performing PTLs improved electrolyzer efficiency by ~1.5 kWh/kg H2 . Specifically, 1 kWh/kg H2 was gained due to reducing membrane deformation and decreasing H 2 crossover. The remainder 0.5 kWh/kg H2 were achieved by improving the electrical contact at the electrode/PTL interface which decreased cell voltage.

08 HYDROGEN↗

Spatially resolved degradation during startup and shutdown in polymer electrolyte membrane fuel cell operation

Polymer electrolyte membrane fuel cells have durability limitations associated with the startup and shutdown of the fuel cell, which is critical for real-world vehicle commercialization. During startup or shutdown, there exists an active region (hydrogen/air) and a passive region (air/air) between the cell inlet and outlet. Internal currents are generated in the passive region causing high-potential excursion in the cathode leading to accelerated carbon corrosion. In this study, a segmented cathode hardware is used to evaluate the effect of platinum loading on both cathode and anode, and carbon support material on degradation due to repeated series of startups or shutdowns. Here, in situ losses in the performance and electrochemical surface area were measured spatially, and ex situ analysis of the catalyst layer thickness and platinum particle size was performed to understand the effect of startup or shutdown on different membrane electrode assembly materials. Startup degrades the region near anode outlet more, while shutdown degrades the region near anode inlet more compared to the rest of the electrode. While various system mitigation strategies have been reported in the literature to limit this degradation, one materials mitigation strategy is to limit the anode's ability to reduce oxygen to water through increasing the ratio of platinum loading in the cathode to the anode, or by using a bi-functional catalyst.

25 ENERGY STORAGE↗

Titanium porous-transport layers for PEM water electrolysis prepared by tape casting

While the porous-transport layer (PTL) is a key component in PEM electrolyzers, it is one of the most underexplored due to limited available structures. In this work, we present a novel PTL design for PEM water electrolyzers enabled by a cost-effective, scalable tape-casting technique. Here, a precise control of the PTL pore structure is achieved by incorporating poreformers of various sizes, and by varying the titanium and poreformer ratio. The structures are characterized with SEM and synchrotron X-ray computed tomography imaging techniques. Comprehensive electrochemical performance analysis demonstrates that higher titanium loading provides improved contact at the catalyst-layer/PTL interface but suffers from severe mass-transport losses due to gas bubbles. We solve this mass-transport problem by mixing in large poreformer beads that produce a highly porous structure with excellent gas removal properties yet still maintaining mechanical integrity. The PTL fabricated with 60:40 Ti:PMMA ratio and 60 μm PMMA bead size outperformed the standard commercial Ti powder-based PTL by 62 mV at 4 A/cm 2 .

25 ENERGY STORAGE↗

Fundamental Investigations and Rational Design of Durable High-Performance SOFC Cathodes

The main objective of this project is to unravel the degradation mechanism of LSCF cathodes under realistic operating conditions with different types of contaminants, aiming towards the rational design of cathodes with high-performance and enhanced durability by combining a porous backbone (such as LSCF) with a thin catalyst coating. The mechanistic understanding will help us to optimize the composition and morphology of the catalyst layer and microstructure of the LSCF backbone for better performance and durability. More specifically, the technical objectives include: (1) to unravel the degradation mechanism of LSCF cathodes under realistic operating conditions with different types of contaminants using in situ and ex situ measurements performed on specially-designed cathodes; (2) to examine the microstructural and compositional evolution of LSCF cathodes as well as the cathode/electrolyte interfaces under realistic operating conditions; (3) to correlate the fuel cell performance instability and degradation with the microstructural and morphological evolution and surface chemistry change of the cathode under realistic operating conditions; (4) to explore new catalyst materials and electrode structures to enhance the stability of the LSCF cathode under realistic operating conditions; and (5) to validate the long term stability of the modified LSCF cathode in commercially available cells under realistic operating conditions. We have systematically evaluated LSCF cathodes in symmetrical cells and anode supported cells under realistic conditions with different types of contaminants such as humidity, CO 2 , and Cr. Electrochemical models for the design of test cells and understanding of mechanisms have been developed for the exploration of fundamental properties of electrode materials. It is demonstrated that the activity and stability of LSCF cathodes can be degraded by the introduction of contaminants. The microstructural and compositional evolution of LSCF cathodes as well as the cathode/electrolyte interfaces under realistic operating conditions has been studied. It is found that SrO readily segregated/enriched on the LSCF surface. More severe contamination conditions cause more SrO on surface. Novel catalyst coatings through particle depositions (PrOx) or continuous thin films (PNM) were successfully developed to improve the activity and stability of LSCF cathodes. Finally, we have demonstrated enhanced activity and stability of LSCF cathodes over longer periods of time in homemade and commercially available cells by an optimized PNM (dense film and particles) infiltration process, under clean air and realistic operating conditions (3% H 2 O, 5% CO 2 and direct Crofer contact). Both performance and durability of single cells with PNM coating has been enhanced compared with those without coating. Raman analysis of cathodes surface indicated that the intensity of SrCrO 4 was significantly decreased.

30 DIRECT ENERGY CONVERSION↗

A review of functions, attributes, properties and measurements for the quality control of proton exchange membrane fuel cell components

Quality control (QC) is an essential part of fuel cell technology industrialization, providing means to reduce cost of components, enhancing the reliability of the final product, and offering specification guidance for new entrants in the supply chain. The membrane electrode assembly (MEA), including membrane, catalyst layer (CL), and gas diffusion layer (GDL), as well as bipolar plate (BP), are key components of a proton exchange membrane (PEM) fuel cell, and the attributes of each component strongly correlate with the cell performance and longevity. To ensure the quality of the fuel cell, it is of great importance to characterize the properties with respect to the standardization of component/sub-component specifications. In collaboration with the fuel cell industry, this work aims at establishing compendiums of attributes, or so-called books of attributes, of key fuel cell components for the QC of PEM fuel cells through reviewing, identifying, categorizing, and prioritizing the main attributes/properties that determine their functionalities. The books of attributes for the major PEM fuel cell components include catalyst coated membrane (CCM) as a sub-assembly, GDL, and BP. To address the full spectrum of fuel cell components, gaskets and sub-gaskets are also included.

25 ENERGY STORAGE↗

Performance enhancement of a polymer-electrolyte membrane H2O and CO2 co-electrolysis system for the production of syngas

Co-electrolysis of water and CO 2 to produce hydrogen and CO would provide an alternative pathway to making chemicals and fuels. The process could provide a way to use excess renewable electricity, or could be coupled to nuclear or carbon-based power generation. Opus 12 has overcome barriers to using a proton exchange membrane (PEM) reactor for this reaction by modifying the cathode catalyst layer to enhance simultaneous electrochemical H 2 production and CO 2 reduction. Current reactor performance metrics in terms of selectivity, current density, and applied voltage meet or exceed internal targets. However, the cell lifetime must be extended for a commercial product to be feasible. Through this H2@Scale project, we propose to work with the Weber Group at LBNL to diagnose performance decay mechanisms that currently limit the lifetime of the electrochemical syngas generator. LBNL is host to a number of advanced PEM diagnostic tools and lab scientists have unique experience in exploring performance and lifetime tradeoffs at the component to cell scales. Using the results of this study, the identified limiting mechanisms will be mitigated through improved cell and catalyst design.

10 SYNTHETIC FUELS↗

Applications of Atomic Layer Deposition in the Modification of Carbon Nanotubes

Atomic Layer Deposition (ALD) is a cost-effective nanoadditive-manufacturing technique that allows for conformal coating of substrates with atomic control in a benign temperature and pressure environment. Using paired precursor gases, thin films can be deposited on flat or textured surfaces ranging from glass, polymers, aerogels, and metals. Through atomic layer control, where single layers of atoms are deposited, fabrication of metal transparent films, nano-laminates, and coatings of nano-channels and pores is achievable. Reaction mechanisms in ALD are normally self-limiting, allowing for atomically accurate control of nanometer (nm) thicknesses. Therefore, high uniformity and precise thickness control make ALD an attractive process for the creation of novel nano-scale devices. Decreases in resistivity and density of electrical wire are needed to improve the function of electronics, electric motors and cables. Such improvements may be accomplished by adding ballistically conducting, metallic carbon nanotubes (CNT) to Cu. ALD was used to coat multiple substrates including CNT with Cu in an effort to make CNT-Cu composites which is more conductive and less dense than Cu. In addition, ALD can be used to as a method to deposit the catalyst layer seed layer for CNT growth using Ni. The ALD of copper metallic films can follow multiple reaction pathways depending on the ALD precursors used. For this work the reaction pathway was deposition of copper oxide and then post process annealing in a hydrogen environment. Copper(II) diacetylacetonate (Cu(acac)2) and ozone are used as precursors for copper oxide. As-deposited copper oxide films prepared at 180°C resulted in a growth per cycle of 1.0 A/cycle with low film resistivity.

Dwivedi, Vivek H.↗

Modeling the dynamic behavior of proton-exchange membrane fuel cell

A two-phase transient model that incorporates the permanent hysteresis observed in the experimentally measured capillary pressure of GDL has been developed. The model provides explanation for the difference in time constant between membrane hydration and dehydration observed in the HFR experiment conducted at LANL. When there is liquid water at the cathode catalyst layer, time constant of the water content in the membrane is closely tied to that of liquid water saturation in the CCL, as the vapor is already saturated. The water content in the membrane will not reach steady state as long as the liquid water flow in the CCL is not at steady state. Also, Increased resistance to proton transport in the membrane is observed when the cell voltage is stepped down to a very low value.

30 DIRECT ENERGY CONVERSION↗

Enhanced Water Management of Polymer Electrolyte Fuel Cells with Additive-Containing Microporous Layers

This work describes the performance improvement of a polymer electrolyte fuel cell with a novel class of microporous layers (MPLs) that incorporates hydrophilic additives: one with 30 μm aluminosilicate fibers and another with multiwalled carbon nanotubes with a domain size of 5 μm. Higher current densities at low potentials were observed for cells with the additive-containing MPLs compared to a baseline cell with a conventional MPL, which correlate with improvements in water management. This is also observed for helium and oxygen experiments and by the lower amount of liquid water in the cell, as determined by neutron radiography. Furthermore, carbon-nanotube-containing MPLs demonstrates improved durability compared to the baseline MPL. Microstructural analyses including nanotomography demonstrate that the filler material in both the additive-containing MPLs provide preferential transport pathways for liquid water, which correlate with ex situ measurements. In conclusion, the main advantage provided by these MPLs is improved liquid-water removal from the cathode catalyst layer, resulting in enhanced oxygen delivery to the electrocatalyst sites.

25 ENERGY STORAGE↗

Engineered nano-scale ceramic supports for PEM fuel cells

Catalyst support durability is currently a technical barrier for commercialization of polymer electrolyte membrane (PEM) fuel cells, especially for transportation applications. Degradation and corrosion of the conventional carbon supports leads to losses in active catalyst surface area and, consequently, reduced performance. As a result, the major aim of this work is to develop support materials that interact strongly with Pt, yet sustain bulk-like catalytic activities with very highly dispersed particles. This latter aspect is key to attaining the 2015 DOE technical targets for platinum group metal (PGM) loadings (0.20 mg/cm{sup 2}). The benefits of the use of carbon-supported catalysts to drastically reduce Pt loadings from the early, conventional Pt-black technology are well known. The supported platinum catalyzed membrane approach widely used today for fabrication of membrane electrode assemblies (MEAs) was developed shortly thereafter these early reports. Of direct relevance to this present work, are the investigations into Pt particle growth in PEM fuel cells, and subsequent follow-on work showing evidence of Pt particles suspended free of the support within the catalyst layer. Further, durability work has demonstrated the detrimental effects of potential cycling on carbon corrosion and the link between electrochemical surface area and particle growth. To avoid the issues with carbon degradation altogether, it has been proposed by numerous fuel cell research groups to replace carbon supports with conductive materials that are ceramic in nature. Intrinsically, these many conductive oxides, carbides, and nitrides possess the prerequisite electronic conductivity required, and offer corrosion resistance in PEMFC environments; however, most reports indicate that obtaining sufficient surface area remains a significant barrier to obtaining desirable fuel ceU performance. Ceramic materials that exhibit high electrical conductivity and necessary stability under fuel cell conditions must also exhibit high surface area as a necessary adjunct to obtaining high Pt dispersions and Pt utilization targets. Our goal in this work is to identify new synthesis approaches together with materials that will lead to ceramic supports with high surface areas and high Pt dispersions. Several strong candidates for use as PEMFC catalyst supports include: transition metal nitrides and substoichiometric titanium oxides, which hither to now have been prepared by other researcher groups with relatively low surface areas (ca. 1-50 m{sup 2}/g typical). To achieve our goals of engineering high surface area, conductive ceramic support for utilization in PEMFCs, a multi-institutional and multi-disciplinary team with experience synthesizing and investigating these materials has been assembled. This team is headed by Los Alamos National Laboratory and includes Oak Ridge National Laboratory and the University of New Mexico. This report describes our fiscal year 2010 technical progress related to applying advanced synthetiC methods towards the development of new ceramic supports for Pt catalysts for PEM fuel cells.

30 DIRECT ENERGY CONVERSION↗

Highly Durable Fluorinated High Oxygen Permeability Ionomers for Proton Exchange Membrane Fuel Cells

For proton exchange membrane fuel cells to be cost-competitive in light- and heavy-duty vehicle applications, their Pt content in the catalyst layers needs to be lowered. However, lowering the Pt content results in voltage losses due to high local oxygen transport resistances at the ionomer–Pt interface. It is therefore crucial to use ionomers that have higher oxygen permeability than Nafion. In this paper, novel high oxygen permeability ionomers (HOPIs) are presented, with up to five times higher oxygen permeability than Nafion, synthesized by copolymerization of perfluoro-2,2-dimethyl-1,3-dioxole (PDD) with perfluoro(4-methyl-3,6-dioxaoct-7-ene) sulfonyl fluoride (PFSVE). PDD is the source of higher permeability due to its open ring structure, while PFSVE provides ionic conductivity. Optimization of PDD content and equivalent weight enables increased fuel cell performance, mainly at high current densities, where HOPIs can achieve power densities >1.25 W cm -2 and exceed the 0.8 A cm -2 U.S. Department of Energy durability target by losing only 4.5 mV, which is over six times less than 30 mV. Finally, the interactions between HOPI and SO 3 - groups with a PtCo/C catalyst are also elucidated here at a fundamental level.

25 ENERGY STORAGE↗

X-ray Photoelectron Spectroscopy Analysis of Nafion-Containing Samples: Pitfalls, Protocols, and Perceptions of Physicochemical Properties

X-ray photoelectron spectroscopy (XPS) is one of the most common techniques used to analyze the surface composition of catalysts and support materials used in polymer electrolyte membrane (PEM) fuel cells and electrolyzers, providing important insights for further improvement of their properties. Characterization of catalyst layers (CLs) is more challenging, which can be at least partially attributed to the instability of ionomer materials such as Nafion during measurements. This work explores the stability of Nafion during XPS measurements, illuminating and addressing Nafion degradation concerns. The extent of Nafion damage as a function of XPS instrumentation, measurement conditions, and sample properties was evaluated across multiple instruments. Results revealed that significant Nafion damage to the ion-conducting sulfonic acid species (>50% loss in sulfur signal) may occur in a relatively short time frame (tens of minutes) depending on the exact nature of the sample and XPS instrument. This motivated the development and validation of a multipoint XPS data acquisition protocol that minimizes Nafion damage, resulting in reliable data acquisition by avoiding significant artifacts from Nafion instability. The developed protocol was then used to analyze both thin film ionomer samples and Pt/C-based CLs. Comparison of PEM fuel cell CLs to Nafion thin films revealed several changes in Nafion spectral features attributed to charge transfer due to interaction with conductive catalyst and support species. This study provides a method to reliably characterize ionomer-containing samples, facilitating fundamental studies of the catalyst-ionomer interface and more applied investigations of structure-processing-performance correlations in PEM fuel cell and electrolyzer CLs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cerium migration during PEM fuel cell accelerated stress testing

Cerium is a radical scavenger which improves polymer electrolyte membrane (PEM) fuel cell durability. During operation, however, cerium rapidly migrates in the PEM and into the catalyst layers (CLs). In this work, membrane electrode assemblies (MEAs) were subjected to accelerated stress tests (ASTs) under different humidity conditions. Cerium migration was characterized in the MEAs after ASTs using X-ray fluorescence. During fully humidified operation, water flux from cell inlet to outlet generated in-plane cerium gradients. Conversely, cerium profiles were flat during low humidity operation, where in-plane water flux was negligible, however, migration from the PEM into the CLs was enhanced. Humidity cycling resulted in both in-plane cerium gradients due to water flux during the hydration component of the cycle, and significant migration into the CLs. Fluoride and cerium emissions into effluent cell waters were measured during ASTs and correlated, which signifies that ionomer degradation products serve as possible counter-ions for cerium emissions. Fluoride emission rates were also correlated to final PEM cerium contents, which indicates that PEM degradation and cerium migration are coupled. Lastly, it is proposed that cerium migrates from the PEM due to humidification conditions and degradation, and is subsequently stabilized in the CLs by carbon catalyst supports.

30 DIRECT ENERGY CONVERSION↗

Structural and electronic properties of InN nanowire network grown by vapor-liquid-solid method

Growth of InN nanowires have been carried out on quartz substrates at different temperatures by vapor-liquid-solid (VLS) technique using different thicknesses of Au catalyst layer. It has been found that a narrow window of Au layer thickness and growth temperature leads to multi-nucleation, in which each site acts as the origin of several nanowires. In this multi-nucleation regime, several tens of micrometer long wires with diameter as small as 20 nm are found to grow along [112{sup -}0] direction (a-plane) to form a dense network. Structural and electronic properties of these wires are studied. As grown nanowires show degenerate n-type behavior. Furthermore, x-ray photoemission study reveals an accumulation of electrons on the surface of these nanowires. Interestingly, the wire network shows persistence of photoconductivity for several hours after switching off the photoexcitation.

36 MATERIALS SCIENCE↗

Dispersion of high oxygen permeability ionomers in water-propanol solutions

There is a growing interest in high oxygen permeability ionomers (HOPI) for better-performing proton exchange membrane fuel cell (PEMFC) catalyst layers. In this study, we used small-angle x-ray scattering (SAXS) to analyze dispersions of two types of perfluorinated sulfonic acid (PFSA) ionomers and a HOPI in water and propanol solvents, at concentrations between 1 wt% and 15 wt%. HOPI dispersions exhibited the interference peak typical of ionomers; by separately fitting the peak and higher- q regions with several models, we demonstrated that HOPI aggregates have a closer average spacing than conventional PFSA ionomers, and smaller aggregate size when assuming a cylindrical geometry. By measuring conventional PFSA ionomers with two side chain lengths and several equivalent weights, we showed that these side chain parameters alone did not explain the differences in aggregate spacing or size. In addition, the pattern was present whether samples were prepared in a 50/50 water/propanol or a more propanol-rich mixture. As such, the structural differences of HOPI could be due to its different backbone monomer. A better understanding of the influence of the HOPI chemistry on dispersion properties could help explain the ink structure and drying characteristics of HOPI observed in prior work. Future study of ionomer-catalyst mixtures, such as measuring ionomer adsorption to carbon, would help elucidate the role of ionomer from ink formulation to the cast electrode.

Aquivion↗

Impacts of catalyst nanolayers on water permeation and swelling of polymer electrolyte membranes

Polymer electrolyte membranes with catalyst layers are the most crucial components of proton exchange membrane (PEM) electrolyzer cells and fuel cells. Their water permeation and swelling behavior significantly impact the proton transport and performance in energy conversion devices. In this study, water permeations and swelling properties of Nafion membranes with different platinum (Pt) nanolayers under different conditions are investigated. Visualization results demonstrate the entire swelling process of Pt-coated Nafion membranes and reveal water transport in Nafion membranes and breakage of the Pt nanolayer. The water permeation of Nafion membranes with a 17 nm Pt nanolayer coating reduces from 40 to less than 20 umol min-1 cm -2 at 80 degrees C and 70 kPa differential pressure. The water permeation of Nafion membranes with a 36 nm Pt coating is slightly lower than one with a 17 nm Pt coating due to higher transport resistance through the thicker Pt nanolayer and smaller cracks on the Pt nanolayer. Nevertheless, the water permeation of Nafion membranes with Pt nanolayers is still in a good range for proton transport applications, demonstrating the feasibility of Pt or other metal coating on Nafion membranes as catalysts or substrates in PEM-based energy devices.

36 MATERIALS SCIENCE↗

Optimization of the CVD parameters for ZnO nanorods growth: Its photoluminescence and field emission properties

Highlights: • Home-made CVD reactor fabricated and successfully used for growing ZnO nanorods. • Growth of nanostructures depends on several CVD process parameters. • CVD parameters, flow rate of carrier gas, substrate temperature, Au catalyst droplet size, growth time duration, etc. optimized. • The mechanism of crystal growth understood by studying FESEM/TEM/XRD. • Photoluminescence and Field emission studies done for defects and applications. - Abstract: Vertically aligned single crystalline ZnO nanorods arrays were grown on a silicon substrate in a CVD reactor using Au as a catalyst. The CVD parameters such as substrate temperature, catalyst layer thickness/morphology and reaction time play a crucial role in the synthesis of nanostructures by the vapor-liquid-solid process. By optimizing these various CVD parameters, highly controlled guided growth of ZnO nanorods was achieved. The structural and morphological properties of resultant ZnO nanorods were studied by means of X-ray diffraction, high-resolution transmission electron microscopy, selected area electron diffraction and field emission scanning electron microscopy. The photoluminescence spectroscopy was also done to investigate the defects in grown ZnO nanorods. The field emission results of nanorods array indicated that the properties of the field emission follow Fowler–Nordheim law. The nanorods (grown for 20 min) are vertically aligned on the substrate surface without entanglements and with good crystal quality as well which is very important for several applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Nano-structured platinum group metal-free catalysts and their integration in fuel cell electrode architectures

The novel platinum group metal-free (PGM-free) catalyst for the oxygen reduction reaction (ORR) is synthesized by a modified sacrificial support method (SSM). The catalyst chemical/surface composition is studied by X-ray photoelectron spectroscopy, and the morphology of the material is observed using both HR-SEM and HR-TEM, demonstratingthe open-frame, self-supported catalysts. This new catalyst’s electrochemical performance is evaluated by polarization curves and has behaviour comparable to the state-of-the-art PGM-free catalysts. Meso-structure imaging shows pores on the order of 100 nm, the mean size of the individual silica particles in the sacrificial support. For the first time, PGM-free catalyst layer (CL) morphology in a membrane electrode assembly (MEA) is studied in detail by combined nano- and micro X-ray computed tomography (CT) and interpretational modelling. The highly inhomogeneous, high-tortuosity, through-thickness structure of the CL is observed with micro-CT. The nano-CT method for these thick PGM-free electrodes is not sufficient to capture the full through-thickness morphology of these electrodes. Water retention curves suggest water pooling at the MEA components‘ interfaces and significant dependence of capilary pressure and saturation on through-thickness location. Lastly, this study is the first of its kind to identify morphology-dependent transport losses in the thick PGM-free electrodes using scale-bridging between meso -, micro-, and macro.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗