Search NASA⌕ Search

SEARCH · Search NASA

Results for “collimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Dosimetric comparison of different multileaf collimator leaves in treatment planning of intensity-modulated radiotherapy for cervical cancer

To study the effect of multileaf collimator (MLC) leaf widths (standard MLC [sMLC] width of 10 mm and micro-MLC [mMLC] width of 4 mm) on intensity-modulated radiotherapy (IMRT) for cervical cancer. Between January 2010 and August 2010, a retrospective analysis was conducted on 12 patients with cervical cancer. The treatment plans for all patients were generated with the same machine setup parameters and optimization methods in a treatment planning system (TPS) based on 2 commercial Elekta MLC devices. The dose distribution for the planning tumor volume (PTV), the dose sparing for organs at risk (OARs), the monitor units (MUs), and the number of IMRT segments were evaluated. For the delivery efficiency, the MUs were significantly higher in the sMLC-IMRT plan than in the mMLC-IMRT plan (802 ± 56.9 vs 702 ± 56.7; p < 0.05). The number of segments in the plans were 58.75 ± 1.8 and 59 ± 1.04 (p > 0.05). For the planning quality, the conformity index (CI) between the 2 paired IMRT plans with the mMLC and the sMLC did not differ significantly (average: 0.817 ± 0.024 vs 0.810 ± 0.028; p > 0.05). The differences of the homogeneity index (HI) between the 2 paired plans were statistically significant (average: 1.122 ± 0.010 vs 1.132 ± 0.014; p < 0.01). For OARs, the rectum, bladder, small intestine, and bony pelvis were evaluated in terms of V{sub 10}, V{sub 20}, V{sub 30}, and V{sub 40}, percentage of contoured OAR volumes receiving 10, 20, 30, and 40 Gy, respectively, and the mean dose (D{sub mean}) received. The IMRT plans with the mMLC protected the OARs better than the plans with the sMLC. There were significant differences (p < 0.05) in evaluated parameters between the 2 paired IMRT plans, except for V{sub 30} and V{sub 40} of the rectum and V{sub 10}, V{sub 20}, V{sub 40}, and D{sub mean} of the bladder. IMRT plans with the mMLC showed advantages over the plans with the sMLC in dose homogeneity for targets, dose sparing of OARs, and fewer MUs in cervical cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Multileaf collimator tongue-and-groove effect on depth and off-axis doses: A comparison of treatment planning data with measurements and Monte Carlo calculations

To investigate how accurately treatment planning systems (TPSs) account for the tongue-and-groove (TG) effect, Monte Carlo (MC) simulations and radiochromic film (RCF) measurements were performed for comparison with TPS results. Two commercial TPSs computed the TG effect for Varian Millennium 120 multileaf collimator (MLC). The TG effect on off-axis dose profile at 3 depths of solid water was estimated as the maximum depth and the full width at half maximum (FWHM) of the dose dip at an interleaf position. When compared with the off-axis dose of open field, the maximum depth of the dose dip for MC and RCF ranged from 10.1% to 20.6%; the maximum depth of the dose dip gradually decreased by up to 8.7% with increasing depths of 1.5 to 10 cm and also by up to 4.1% with increasing off-axis distances of 0 to 13 cm. However, TPS results showed at most a 2.7% decrease for the same depth range and a negligible variation for the same off-axis distances. The FWHM of the dose dip was approximately 0.19 cm for MC and 0.17 cm for RCF, but 0.30 cm for Eclipse TPS and 0.45 cm for Pinnacle TPS. Accordingly, the integrated value of TG dose dip for TPS was larger than that for MC and RCF and almost invariant along the depths and off-axis distances. We concluded that the TG dependence on depth and off-axis doses shown in the MC and RCF results could not be appropriately modeled by the TPS versions in this study.

61 RADIATION PROTECTION AND DOSIMETRY↗

Can cost make a difference dosimetrically? Volumetric modulated arc therapy study for multileaf collimators of various widths for head and neck and prostate cancers

Cancer is a global health issue that disproportionately kills based on stage of disease, cellular pathology, and genetics, to name a few. Another variable to consider in this ongoing fight is treatment machine complexity that leads to elevated development and purchasing cost, leading to a reduced use. Reducing the complexity (in hopes of lowering costs) would benefit underdeveloped, low- and middle-income countries by introducing newer treatment technology, as their currently accepted standards do not meet standards of more advanced, developed countries. In this study, unilateral head and neck (H&N), and prostate cases using volumetric modulated arc therapy (VMAT) were tested with multiple segment widths of 5, 10, 15, and 20 mm to create treatable plans. Pinnacle 9.10v was used for planning purposes. A total of 12 cases were planned with varying multileaf collimator (MLC) widths. Treatment plans were evaluated retrospectively. Results show that altering the MLC widths from 5 through 20 mm produces both comparable and treatable plans up to 99% and 98% target coverage for H&N and prostate, respectively, albeit clinically significant hot spots were shown to increase with increasing segment width. Furthermore, the results show that increasing widths can produce comparable treatment plans as measured against our current Food and Drug Administration (FDA)–approved treatment devices—leading to an increase in treatment efficacy in economically underdeveloped countries.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric effect of multileaf collimator leaf width on volumetric modulated arc stereotactic radiotherapy for spine tumors

This work aimed to study the dosimetric effect of multileaf collimator (MLC) leaf widths in treatment plans for patients receiving volumetric modulated arc therapy (VMAT) for spine stereotactic body radiation therapy (SBRT). Thirteen patients treated with spine SBRT were retrospectively selected for this study. The patients were treated following the protocol of the Radiation Therapy Oncology Group 0631 (RTOG 0631) for spine metastasis. The prescription dose was 16 Gy in 1 fraction to 90% of the target volume (V16 > 90%). The maximum spinal cord dose of 14 Gy and 10% of the spinal cord receiving < 10 Gy (V10) were the acceptable tolerance doses. For the purpose of this study, 2 dual-arc VMAT plans were created for each patient using 3 different MLC leaf widths: 2.5 mm, 4 mm, and 5 mm. The compliance with the RTOG 0631 protocol, conformity index (CI), dose gradient index (DGI), and number of monitor units (MUs) were compared. The average V16Gy of the targets was 91.8 ± 1.2%, 92.2 ± 2.1%, and 91.7 ± 2.3% for 2.5-mm, 4-mm, and 5-mm leaf widths, respectively (p = 0.78). Accordingly, the average CI was 1.45 ± 0.4, 1.47 ± 0.29, and 1.47 ± 0.31 (p = 0.98), respectively. The average DGI was 0.22 ± 0.04, 0.20 ± 0.06, and 0.22 ± 0.05, respectively (p = 0.77). The average maximum dose to the spinal cord was 12.45 ± 1.0 Gy, 12.80 ± 1.0 Gy, and 12.48 ± 1.1 (p = 0.62) and V10% of the spinal cord was 3.6 ± 2.1%, 5.6 ± 2.8%, and 5.5 ± 3.0% (p = 0.11) for 2.5-mm, 4-mm, and 5-mm leaf widths, respectively. Accordingly, the average number of MUs was 4341 ± 500 MU, 5019 ± 834 MU, and 4606 ± 691 MU, respectively (p = 0.053). The use of 2.5-mm, 4-mm, and 5-mm MLCs achieved similar VMAT plan quality as recommended by the RTOG 0631. The dosimetric parameters were also comparable for the 3 MLCs. In general, any of these leaf widths can be used for spine SBRT using VMAT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radial modes of laterally stiffened piezoelectric disc transducers for ultrasonic collimated beam generation

Here, we numerically investigate the resonance and vibration characteristics of radial modes of laterally stiffened piezoelectric disc transducers. Lateral stiffening is modeled using a spring and vibration characteristics of the piezo-disc are investigated with increasing lateral stiffness. It is found that the resonant frequency response of the radial modes follows an asymptotic behavior approaching that of a clamped disc with increasing lateral stiffness. The radial mode vibration pattern of the discs is also found to be affected by lateral stiffness. While the vibration pattern of a free disc corresponds to a Bessel function, laterally stiffened discs show edge-effects where they depart from the Bessel-like behavior. In addition, a fully clamped piezo-disc is found to have an extra side-lobe when compared to a free disc. Ultrasonic beam profiles generated from radial modes of laterally stiffened discs are numerically investigated. It is found that the free piezo-disc generates a Bessel beam that has multiple side-lobes. Increasing the lateral stiffness results in a significant reduction of side-lobes in the beam profile. This technique of generating a collimated beam with side-lobe reduction finds significant applications in imaging through concrete, drilling mud, and other highly attenuating materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Highly efficient acceleration and collimation of high-density plasma using laser-induced cavity pressure

An efficient scheme of acceleration and collimation of dense plasma is proposed and examined. In the scheme, a target placed in a cavity coupled with a guiding channel is irradiated by a laser beam introduced into the cavity through a hole and accelerated along the channel by the pressure of the ablating plasma confined in the cavity. Using 1.315 mum, 0.3 ns laser pulse of energy up to 200 J and a thin CH target, it was shown that the energetic efficiency of acceleration in this scheme is an order of magnitude higher than in the case of conventional ablative acceleration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Long distance fiber-optic displacement sensor based on fiber collimator

A simple fiber-optic displacement sensor based on reflective intensity modulated technology is demonstrated using a fiber collimator. The sensing range is over 30 cm, which is over 100 times that of the conventional fiber-optic displacement sensor based on the normal single-mode fiber. The measured data are fitted into linear equation very well and the values of R-square are more than 0.995. The sensitivity of the device achieves 0.426 dB/cm over the range of 5-30 cm. By applying the relative technique, the errors resulted from the fluctuation of light source and influences of environment are effectively eliminated, and the stability for wide range measurement can be improved. The simplicity of the design, high dynamic range, stability and the ease of the fabrication make it suitable for applications in industries.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High efficiency multichannel collimator for structural studies of liquids and low-Z materials at high pressures and temperatures

A high efficiency multichannel collimator (MCC) device has been developed at the high pressure beamline ID27 of the European Synchrotron Radiation Facility to drastically reduce the x-ray background from the sample environment in the Paris-Edinburgh press. The main technical difficulty, which resides in the minimum slits size achievable using the classical mono-bloc design, has been resolved using an original concept based on a set of independent slits. Then, a very small slit size of 50 {mu}m was manufactured resulting in a great improvement of the signal to background ratio. In addition, the transfer function of the MCC has been measured using the x-ray diffusion signal of a metal doped glass and efficiently applied to correct the raw data. The potential of this new device is illustrated in two challenging examples: iron-sulfur liquid structures and C{sub 60} polymerization process at high pressure and high temperature.

43 PARTICLE ACCELERATORS↗

Use of a multichannel collimator for structural investigation of low-Z dense liquids in a diamond anvil cell: Validation on fluid H{sub 2} up to 5 GPa

We report the first application of a multichannel collimator (MCC) to perform quantitative structure factor measurements of dense low-Z fluids in a diamond anvil cell (DAC) using synchrotron x-ray diffraction. The MCC design, initially developed for the Paris-Edinburgh large volume press geometry, has been modified for use with diamond anvil cells. A good selectivity of the diffracted signal of the dense fluid sample is obtained due to a large rejection of the Compton diffusion from the diamond anvils. The signal to background ratio is significantly improved. We modify previously developed analytical techniques for quantitative measurement of the structure factor of fluids in DACs [J. H. Eggert, G. Weck, P. Loubeyre, and M. Mezouar, Phys. Rev. B 65, 174105 (2002)] to account for the contribution of the MCC. We present experimental results on liquids argon and hydrogen at 296 K to validate our method and test its limits, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of optical pulses of duration down to 8 fs upon filamentation of collimated femtosecond laser radiation in argon

A new scheme providing self-compression of femtosecond laser radiation upon filamentation of a collimated beam in argon at a pressure of {approx}0.8 atm is experimentally realised. Pulses with the initial duration of 55 fs were compressed down to 8 fs, the peak power of the compressed pulse exceeding 20 GW. (letters)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electron beam deflection, focusing, and collimation by a femtosecond laser lens

This work examines spatial separation of femtosecond electron bunches using the ponderomotive potential created by femtosecond laser pulses. It is shown that ponderomotive optical potentials are capable of effectively deflecting, focusing, and collimating narrow femtosecond electron bunches. (laser applications and other topics in quantum electronics)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Calculation and experimental verification of a collimator with a Kerr lens for fibre laser mode locking

We present the calculation and experimental verification of the operation of a collimator coupling a light beam into an optical fibre with an As{sub 2}S{sub 3} nonlinear plate. It is shown that a Kerr lens formed in the plate with an increase in the peak pulse power leads to an increase in the output coupling ratio by about 15%, which can be used for the passive mode locking of a fibre laser. (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Mini-beam collimator enables micro-crystallography experiments on standard beamlines.

The high-brilliance X-ray beams from undulator sources at third-generation synchrotron facilities are excellent tools for solving crystal structures of important and challenging biological macromolecules and complexes. However, many of the most important structural targets yield crystals that are too small or too inhomogeneous for a 'standard' beam from an undulator source, 25-50 {micro}m (FWHM) in the vertical and 50-100 {micro}m in the horizontal direction. Although many synchrotron facilities have microfocus beamlines for other applications, this capability for macromolecular crystallography was pioneered at ID-13 of the ESRF. The National Institute of General Medical Sciences and National Cancer Institute Collaborative Access Team (GM/CA-CAT) dual canted undulator beamlines at the APS deliver high-intensity focused beams with a minimum focal size of 20 {micro}m x 65 {micro}m at the sample position. To meet growing user demand for beams to study samples of 10 {micro}m or less, a 'mini-beam' apparatus was developed that conditions the focused beam to either 5 {micro}m or 10 {micro}m (FWHM) diameter with high intensity. The mini-beam has a symmetric Gaussian shape in both the horizontal and vertical directions, and reduces the vertical divergence of the focused beam by 25%. Significant reduction in background was achieved by implementation of both forward- and back-scatter guards. A unique triple-collimator apparatus, which has been in routine use on both undulator beamlines since February 2008, allows users to rapidly interchange the focused beam and conditioned mini-beams of two sizes with a single mouse click. The device and the beam are stable over many hours of routine operation. The rapid-exchange capability has greatly facilitated sample screening and resulted in several structures that could not have been obtained with the larger focused beam.

36 MATERIALS SCIENCE↗

Dosimetric characteristics of Novalis Tx system with high definition multileaf collimator

A new Novalis Tx system equipped with a high definition multileaf collimator (HDMLC) recently became available to perform both image-guided radiosurgery and conventional radiotherapy. It is capable of delivering a highly conformal radiation dose with three energy modes: 6 MV photon energy, 15 MV photon energy, and 6 MV photon energy in a stereotactic radiosurgery mode with 1000 MU/min dose rate. Dosimetric characteristics of the new Novalis Tx treatment unit with the HDMLC are systematically measured for commissioning. A high resolution diode detector and miniion-chamber detector are used to measure dosimetric data for a range of field sizes from 4x4 mm to 400x400 mm. The commissioned Novalis Tx system has passed the RPC stereotactic radiosurgery head phantom irradiation test. The Novalis Tx system not only expands its capabilities with three energy modes, but also achieves better beam conformity and sharer beam penumbra with HDMLC. Since there is little beam data information available for the new Novalis Tx system, we present in this work the dosimetric data of the new modality for reference and comparison.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Matching extended-SSD electron beams to multileaf collimated photon beams in the treatment of head and neck cancer

Purpose: Matching the penumbra of a 6 MeV electron beam to the penumbra of a 6 MV photon beam is a dose optimization challenge, especially when the electron beam is applied from an extended source-to-surface distance (SSD), as in the case of some head and neck treatments. Traditionally low melting point alloy blocks have been used to define the photon beam shielding over the spinal cord region. However, these are inherently time consuming to construct and employ in the clinical situation. Multileaf collimators (MLCs) provide a fast and reproducible shielding option but generate geometrically nonconformal approximations to the desired beam edge definition. The effects of substituting Cerrobend for the MLC shielding mode in the context of beam matching with extended-SSD electron beams are the subject of this investigation. Methods: Relative dose beam data from a Varian EX 2100 linear accelerator were acquired in a water tank under the 6 MeV electron beam at both standard and extended-SSD and under the 6 MV photon beam defined by Cerrobend and a number of MLC stepping regimes. The effect of increasing the electron beam SSD on the beam penumbra was assessed. MLC stepping was also assessed in terms of the effects on both the mean photon beam penumbra and the intraleaf dose-profile nonuniformity relative to the MLC midleaf. Computational techniques were used to combine the beam data so as to simulate composite relative dosimetry in the water tank, allowing fine control of beam abutment gap variation. Idealized volumetric dosimetry was generated based on the percentage depth-dose data for the beam modes and the abutment geometries involved. Comparison was made between each composite dosimetry dataset and the relevant ideal dosimetry dataset by way of subtraction. Results: Weighted dose-difference volume histograms (DDVHs) were produced, and these, in turn, summed to provide an overall dosimetry score for each abutment and shielding type/angle combination. Increasing the electron beam SSD increased the penumbra width (defined as the lateral distance of the 80% and 20% isodose contours) by 8-10 mm at the depths of 10-20 mm. Mean photon beam penumbra width increased with increased MLC stepping, and the mean MLC penumbra was {approx_equal}1.5 times greater than that across the corresponding Cerrobend shielding. Intraleaf dose discrepancy in the direction orthogonal to the beam edge also increased with MLC stepping. Conclusions: The weighted DDVH comparison techniques allowed the composite dosimetry resulting from the interplay of the abovementioned variables to be ranked. The MLC dosimetry ranked as good or better than that resulting from beam matching with Cerrobend for all except large field overlaps (-2.5 mm gap). The results for the linear-weighted DDVH comparison suggest that optimal MLC abutment dosimetry results from an optical surface gap of around 1{+-}0.5 mm. Furthermore, this appears reasonably lenient to abutment gap variation, such as that arising from uncertainty in beam markup or other setup errors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric characterization of a multileaf collimator for a new four-dimensional image-guided radiotherapy system with a gimbaled x-ray head, MHI-TM2000

Purpose: To present the dosimetric characterization of a multileaf collimator (MLC) for a new four-dimensional image-guided radiotherapy system with a gimbaled x-ray head, MHI-TM2000. Methods: MHI-TM2000 has an x-ray head composed of an ultrasmall linear accelerator guide and a system-specific MLC. The x-ray head can rotate along the two orthogonal gimbals (pan and tilt rotations) up to {+-}2.5 deg., which swings the beam up to {+-}41.9 mm in each direction from the isocenter on the isocenter plane perpendicular to the beam. The MLC design is a single-focus type, has 30 pairs of 5 mm thick leaves at the isocenter, and produces a maximum field size of 150x150 mm{sup 2}. Leaf height and length are 110 and 260 mm, respectively. Each leaf end is circular, with a radius of curvature of 370 mm. The distance that each leaf passes over the isocenter is 77.5 mm. Radiation leakage between adjacent leaves is minimized by an interlocking tongue-and-groove (T and G) arrangement with the height of the groove part 55 mm. The dosimetric characterizations including field characteristics, leaf position accuracy, leakage, and T and G effect were evaluated using a well-commissioned 6 MV photon beam, EDR2 films (Kodak, Rochester, NY), and water-equivalent phantoms. Furthermore, the field characteristics and leaf position accuracy were evaluated under conditions of pan or tilt rotation. Results: The differences between nominal and measured field sizes were within {+-}0.5 mm. Although the penumbra widths were greater with wider field size, the maximum width was <5.5 mm even for the fully opened field. Compared to the results of field characteristics without pan or tilt rotation, the variation in field size, penumbra width, flatness, and symmetry was within {+-}1 mm/1% at the maximum pan or tilt rotational angle. The leaf position accuracy was 0.0{+-}0.1 mm, ranging from -0.3 to 0.2 mm at four gantry angles of 0 deg., 90 deg., 180 deg., and 270 deg. with and without pan or tilt rotation. The interleaf leakage was up to 0.21%, whereas the intraleaf leakage was <0.12%. T and G decreased the doses by 10.7%, on average. Conclusions: This study demonstrated that MHI-TM2000 has the capability for high leaf position accuracy and low leakage, leading to highly accurate intensity-modulated radiotherapy delivery. Furthermore, substantial changes in the dosimetric data on field characteristics and leaf position accuracy were not observed even at the maximum pan or tilt rotation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Experience of micromultileaf collimator linear accelerator based single fraction stereotactic radiosurgery: Tumor dose inhomogeneity, conformity, and dose fall off

Purpose: Sharp dose fall off outside a tumor is essential for high dose single fraction stereotactic radiosurgery (SRS) plans. This study explores the relationship among tumor dose inhomogeneity, conformity, and dose fall off in normal tissues for micromultileaf collimator (mMLC) linear accelerator (LINAC) based cranial SRS plans. Methods: Between January 2007 and July 2009, 65 patients with single cranial lesions were treated with LINAC-based SRS. Among them, tumors had maximum diameters {<=}20 mm: 31; between 20 and 30 mm: 21; and >30 mm: 13. All patients were treated with 6 MV photons on a Trilogy linear accelerator (Varian Medical Systems, Palo Alto, CA) with a tertiary m3 high-resolution mMLC (Brainlab, Feldkirchen, Germany), using either noncoplanar conformal fixed fields or dynamic conformal arcs. The authors also created retrospective study plans with identical beam arrangement as the treated plan but with different tumor dose inhomogeneity by varying the beam margins around the planning target volume (PTV). All retrospective study plans were normalized so that the minimum PTV dose was the prescription dose (PD). Isocenter dose, mean PTV dose, RTOG conformity index (CI), RTOG homogeneity index (HI), dose gradient index R{sub 50}-R{sub 100} (defined as the difference between equivalent sphere radius of 50% isodose volume and prescription isodose volume), and normal tissue volume (as a ratio to PTV volume) receiving 50% prescription dose (NTV{sub 50}) were calculated. Results: HI was inversely related to the beam margins around the PTV. CI had a ''V'' shaped relationship with HI, reaching a minimum when HI was approximately 1.3. Isocenter dose and mean PTV dose (as percentage of PD) increased linearly with HI. R{sub 50}-R{sub 100} and NTV{sub 50} initially declined with HI and then reached a plateau when HI was approximately 1.3. These trends also held when tumors were grouped according to their maximum diameters. The smallest tumor group (maximum diameters {<=}20 mm) had the most HI dependence for dose fall off. For treated plans, CI averaged 2.55{+-}0.79 with HI 1.23{+-}0.06; the average R{sub 50}-R{sub 100} was 0.41{+-}0.08, 0.55{+-}0.10, and 0.65{+-}0.09 cm, respectively, for tumors {<=}20 mm, between 20 and 30 mm, and >30 mm. Conclusions: Tumor dose inhomogeneity can be used as an important and convenient parameter to evaluate mMLC LINAC-based SRS plans. Sharp dose fall off in the normal tissue is achieved with sufficiently high tumor dose inhomogeneity. By adjusting beam margins, a homogeneity index of approximately 1.3 would provide best conformity for the authors' SRS system.

60 APPLIED LIFE SCIENCES↗

Real-time verification of multileaf collimator-driven radiotherapy using a novel optical attenuation-based fluence monitor

Purpose: Multileaf collimator (MLC)-driven conformal radiotherapy modalities [e.g., such as intensity-modulated radiotherapy (IMRT), intensity-modulated arc therapy, and stereotactic body radiotherapy] are more subject to delivery errors and dose calculation inaccuracies than standard modalities. Fluence monitoring during treatment delivery could reduce such errors by allowing an independent interface to quantify and assess measured difference between the delivered and planned treatment administration. We developed an optical attenuation-based detector to monitor fluence for the on-line quality control of radiotherapy delivery. The purpose of the current study was to develop the theoretical background of the invention and to evaluate the detector's performance both statistically and in clinical situations. Methods: We aligned 60 27-cm scintillating fibers coupled to a photodetector via clear optical fibers in the direction of motion of each of the 60 leaf pairs of a 120 leaves Millenium MLC on a Varian Clinac iX. We developed a theoretical model to predict the intensity of light collected on each side of the scintillating fibers when placed under radiation fields of varying sizes, intensities, and positions. The model showed that both the central position of the radiation field on the fiber (x{sub c}) and the integral fluence passing through the fiber ({Phi}{sub int}) could be assessed independently in a single measurement. We evaluated the performance of the prototype by (1) measuring the intrinsic variation of the measured values of x{sub c} and {Phi}{sub int}, (2) measuring the impact on the measured values of x{sub c} and {Phi}{sub int} of random leaf positioning errors introduced into IMRT fields, and (3) comparing the predicted values of x{sub c} and {Phi}{sub int} calculated with the treatment planning software to the measured values of x{sub c} and {Phi}{sub int} in order to assess the predictive effectiveness of the developed theoretical model. Results: We observed a very low intrinsic dispersion, dominated by Poisson statistics, for both x{sub c} (standard deviations of less than 1 mm) and {Phi}{sub int} (standard deviations of less than 0.20%). When confronted with random leaf positioning errors from IMRT segments, {Phi}{sub int} was highly sensitive to single leaf positioning errors as small as 1 mm at isocenter, while x{sub c} was sensitive to leaf pair translation errors of at least 2 mm at isocenter. Owing to the uncertainties in the doses calculated in regions of high perpendicular dose gradients, the measured values of x{sub c} and {Phi}{sub int} deviated from the predicted values of x{sub c} and {Phi}{sub int} by a mean of 1.3 mm and 2.6%, respectively. Conclusion: Our study showed that an optical attenuation-based detector can be used to effectively monitor integral fluence during radiotherapy delivery. The performance of such a system would enable real-time quality control of the incident fluence in current MLC-driven treatments such as IMRT and future adaptive radiotherapy procedures where new treatment plans will have to be delivered without passing thru the current standard quality control chain.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗