Column and Plate Compressive Strengths of Aircraft Structural Martials Extruded 0-1HTA Magnesium Alloy

Column and plate compressive strengths of extruded 0-1HTA magnesium alloy were determined both within and beyond the elastic range from tests of flat end H-section columns and from local instability tests of H-, Z-, and channel section columns. These tests are part of an extensive research investigation to provide data on the structural strength of various aircraft materials. The results are presented in the form of curves and charts that are suitable for use in the design and analysis of aircraft structures.

Heimerl, George J↗

Secular evolution of the vertical column abundances of CHClF2 (HCFC-22) in the Earth's atmosphere inferred from ground-based IR solar observations at the Jungfraujoch and at Kitt Peak, and comparison with model calculations

Series of high-resolution infrared solar spectra recorded at the International Scientific Station of the Jungfraujoch, Switzerland, between 06/1986 and 11/1992, and at Kitt Peak National Observatory, Tucson, Arizona (U.S.A.), from 12/1980 to 04/1992, have been analyzed to provide a comprehensive ensemble of vertical column abundances of CHClF2 (HCFC-22; Freon-22) above the European and the North American continents. The columns were derived from nonlinear least-squares curve fittings between synthetic spectra and the observations containing the unresolved 2 nu(sub 6) Q-branch absorption of CHClF2 at 829.05/cm. The changes versus time observed in these columns were modeled assuming both an exponential and a linear increase with time. The exponential rates of increase at one-sigma uncertainties were found equal to (7.0 +/- 0.35)%/yr for the Junfraujoch data and (7.0 +/- 0.23)%/yr for the Kitt Peak data. The exponential trend of 7.0%/yr found at both stations widely separated in location can be considered as representative of the global increase of the CHClF2 burden in the Earth's atmosphere during the period 1980 to 1992. When assuming two realistic vertical volume mixing ratio profiles for CHClF2 in the troposphere, one quasi constant and the other decreasing by about 13% from the ground to the tropopause, the concentrations for mid-1990 were found to lie between 97 and 111 pptv (parts per trillion by volume) at the 3.58 km altitude of the Jungfraujoch and between 97 and 103 pptv at Kitt Peak, 2.09 km above sea level. Corresponding values derived from calculations using a high vertical resolution-2D model and recently compiled HCFC-22 releases to the atmosphere, were equal to 107 and 105 pptv, respectively, in excellent agreement with the measurements. The model calculated lifetime of CHClF2 was found equal to 15.6 years. The present results are compared critically with similar data found in the literature. On average, the concentrations found here are lower by 15-20% than those derived from in situ investigations; this difference cannot be explained by the absolute uncertainty of +/- 11% assigned presently to the infrared remote measurements.

Zander, R.↗

Infrared spectroscopic measurements of the ethane (C2H6) total column abundance above Mauna Loa, Hawaii -- seasonal variations

About 200 i.r. solar spectra recorded at 0.01/cm resolution on 71 days between November 1991 and July 1993 at the Network for the Detection of Stratospheric Change (NDSC) station at Mauna Loa, Hawaii (latitude 19.53 deg N, longitude 155.58 deg W, elevation 3.459 km) have been analyzed with a nonlinear least-squares spectral fitting technique to study temporal variations in the total column of atmospheric ethane (C2H6) above the site. The results were derived from the analysis of the unresolved nu(sub 7) band (P)Q(sub 3) subbranch at 2976.8/cm. A distinct seasonal cycle is observed with a factor of 2 variation, a maximum total column of 1.16 x 10(exp 16) mol/sq cm at the end of winter, and a minimum total column of 0.53 x 10(exp 16) mol/sq cm at the end of summer. Our measurements are compared with previous observations and model predictions.

Rinsland, C. P.↗

Column measurements of stratospheric trace species over Are, Sweden in the winter of 1991-1992

Total vertical column amounts of stratospheric HCl, HF, ClONO2 and HNO3 are reported from high resolution infrared solar absorption spectra taken during the European Arctic Stratospheric Ozone Experiment (EASOE) in the winter of 1991-1992. These ground based measurements were made near Are in North Sweden (63.4 deg N, 13.1 deg E) at an altitude of 800 m using a Fourier transform spectrometer and tunable diode laser heterodyne spectrometer. On 9th January 1992 the HCl vertical column dropped to 1.2 x 10(exp 15) molecules/sq cm from a November average of 3.6 x 10(exp 15) molecules/sq cm. The HCl drop occurred at a time when Are was below the polar vortex and the lower stratospheric ClO column above Are was elevated to approximately 2 x 10(exp 15) molecules/sq cm as measured by the Microwave Limb Sounder experiment on the Upper Atmosphere Research Satellite. These measurements indicate conversion of lower stratospheric chlorine from reservoir to chemically active forms.

Bell, W.↗

Infrared Spectroscopic Measurements of the Ethane (C2H6) Total Column Abundance Above Mauna Loa, Hawaii: Seasonal Variations

About 200 i.r. solar spectra recorded at 0.01/ cm resolution on 71 days between November 1991 and July 1993 at the Network for the Detection of Stratospheric Change (NDSC) station at Mauna Loa, Hawaii (latitude 19.53 deg N, longitude 155.58 deg W, elevation 3.459 km) have been analyzed with a nonlinear least-squares spectral fitting technique to study temporal variations in the total column of atmospheric ethane (C2H6) above the site. The results were derived from the analysis of the unresolved nu(sub 7) band (sup P)Q(sub 3) subbranch at 2976.8/cm. A distinct seasonal cycle is observed with a factor of 2 variation, a maximum total column of 1.1 6 x 10(exp 16) mol /sq cm at the end of winter, and a minimum total column of 0.53 x 10(exp 16) mol/sq cm at the end of summer. Our measurements are compared with previous observations and model predictions.

Rinsland, C. P.↗

Effects of Cabin Upsets on Adsorption Columns for Air Revitalization

The National Aeronautics and Space Administration (NASA) utilizes adsorption technology as part of contaminant removal systems designed for long term missions. A variety of trace contaminants can be effectively removed from gas streams by adsorption onto activated carbon. An activated carbon adsorption column meets NASA's requirements of a lightweight and efficient means of controlling trace contaminant levels aboard spacecraft and space stations. The activated carbon bed is part of the Trace Contaminant Control System (TCCS) which is utilized to purify the cabin atmosphere. TCCS designs oversize the adsorption columns to account for irregular fluctuations in cabin atmospheric conditions. Variations in the cabin atmosphere include changes in contaminant concentrations, temperature, and relative humidity. Excessively large deviations from typical conditions can result from unusual crew activity, equipment malfunctions, or even fires. The research carried out under this award focussed in detail on the effects of cabin upsets on the performance of activated carbon adsorption columns. Both experiments and modeling were performed with an emphasis on the roll of a change in relative humidity on adsorption of trace contaminants. A flow through fixed-bed apparatus was constructed at the NASA Ames Research Center, and experiments were performed there by W. Scot Appel under the direction of Dr. John E. Finn. Modeling work was performed at the University of Virginia and at Vanderbilt University by W. Scot Appel under the direction of M. Douglas LeVan. All three participants collaborated in all of the various phases of the research. The most comprehensive document describing the research is the Ph.D. dissertation of W. Scot Appel. Results have been published in several papers and presented in talks at technical conferences. All documents have been transmitted to Dr. John E. Finn.

LeVan, M. Douglas↗

Effects of Cabin Upsets on Adsorption Columns for Air Revitalization

The National Aeronautics and Space Administration (NASA) utilizes adsorption technology as part of contaminant removal systems designed for long term missions. A variety of trace contaminants can be effectively removed from gas streams by adsorption onto activated carbon. An activated carbon adsorption column meets NASA's requirements of a lightweight and efficient means of controlling trace contaminant levels aboard spacecraft and space stations. The activated carbon bed is part of the Trace Contaminant Control System (TCCS) which is utilized to purify the cabin atmosphere. TCCS designs oversize the adsorption columns to account for irregular fluctuations in cabin atmospheric conditions. Variations in the cabin atmosphere include changes in contaminant concentrations, temperature, and relative humidity. Excessively large deviations from typical conditions can result from unusual crew activity, equipment malfunctions, or even fires. The research carried out under this award focussed in detail on the effects of cabin upsets on the performance of activated carbon adsorption columns. Both experiments and modeling were performed with an emphasis on the roll of a change in relative humidity on adsorption of trace contaminants. A flow through fixed-bed apparatus was constructed at the NASA Ames Research Center, and experiments were performed there. Modeling work was performed at the University of Virginia.

LeVan, Douglas↗

Two-Phase Flow in Packed Columns and Generation of Bubbly Suspensions for Chemical Processing in Space

For long-duration space missions, the life support and In-Situ Resource Utilization (ISRU) systems necessary to lower the mass and volume of consumables carried from Earth will require more sophisticated chemical processing technologies involving gas-liquid two-phase flows. This paper discusses some preliminary two-phase flow work in packed columns and generation of bubbly suspensions, two types of flow systems that can exist in a number of chemical processing devices. The experimental hardware for a co-current flow, packed column operated in two ground-based low gravity facilities (two-second drop tower and KC- 135 low-gravity aircraft) is described. The preliminary results of this experimental work are discussed. The flow regimes observed and the conditions under which these flow regimes occur are compared with the available co-current packed column experimental work performed in normal gravity. For bubbly suspensions, the experimental hardware for generation of uniformly sized bubbles in Couette flow in microgravity conditions is described. Experimental work was performed on a number of bubbler designs, and the capillary bubble tube was found to produce the most consistent size bubbles. Low air flow rates and low Couette flow produce consistent 2-3 mm bubbles, the size of interest for the "Behavior of Rapidly Sheared Bubbly Suspension" flight experiment. Finally the mass transfer implications of these two-phase flows is qualitatively discussed.

Motil, Brian J.↗

A Robust Retrieval of Water Vapor Column In Dry Arctic Conditions Using the Rotating Shadowband Spectroradiometer

A method to retrieve water vapor column using the 940-nm water vapor absorption band in dry Arctic conditions is presented. The retrievals with this method are stable with respect to uncertainties in instrument radiometric calibration, air pressure, solar source function, and aerosols. The water vapor column was retrieved with this method using spectra obtained with the rotating shadowband spectroradiometer (RSS) that was deployed during an intensive observation period near Barrow, Alaska, in March 1999. A line-by-line radiative transfer model was used to compute water vapor transmittance. The retrievals with this method are compared with retrievals obtained from three independent measurements with microwave radiometers. All four measurements show the same pattern of temporal variations. The RSS results agree most closely with retrievals obtained with the millimeter-wave imaging radiometer (MIR) at its 183 GHz +/- 7 double-side band channel. Their correlation over a period of 7 days when water vapor column varied between 0.75 mm and 3.6 mm (according to RSS) is 0.968 with MIR readings 0.12 mm higher on average.

Kiedron, P.↗

Fabry-Perot Interferometer for Column CO2: Airborne

Global atmospheric CO2 measurements are essential to resolving significant discrepancies in our understanding of the global carbon budget and, hence, humankind's role in global climate change. The science measurement requirements for CO2 are, however, extremely demanding (precision approximately 0.3%). We are developing a novel application of a Fabry-Perot interferometer to detect spectral absorption of reflected sunlight by CO2 and O2 in the atmosphere that should be able to achieve sufficient sensitivity and signal-to-noise to measure column CO2 at the target specification. We are currently constructing a prototype instrument for deployment on aircraft. The aircraft version will measure total column CO2 and CO2 below the aircraft as well as O2, which allows normalization of CO2 column amounts for varying surface height and pressure. This instrument will be a valuable asset in carbon budget field studies as well as a useful tool for evaluating existing and future space-based CO2 measurements. We will present the instrument concept, sensitivity calculations, and the results of testing a bench system in the laboratory and outdoors on the ground. We will also discuss our plan for deployment on the aircraft and potential flight applications to the CO2 budget problem.

Kawa, S. R.↗

Sensitivity Studies for Space-based Measurements of Atmospheric Total Column Carbon Dioxide Using Reflected Sunlight

A series of sensitivity studies is carried out to explore the feasibility of space-based global carbon dioxide (CO2) measurements for global and regional carbon cycle studies. The detection method uses absorption of reflected sunlight in the CO2 vibration-rotation band at 1.58 micron. The sensitivities of the detected radiances are calculated using the line-by-line model (LBLRTM), implemented with the DISORT (Discrete Ordinates Radiative Transfer) model to include atmospheric scattering in this band. The results indicate that (a) the small (approx.1%) changes in CO2 near the Earth's surface are detectable in this CO2 band provided adequate sensor signal-to-noise ratio and spectral resolution are achievable; (b) the effects of other interfering constituents, such as water vapor, aerosols and cirrus clouds, on the radiance are significant but the overall effects of the modification of light path length on total back-to-space radiance sensitivity to CO2 change are minor for general cases, which means that generally the total column CO2 can be derived in high precision from the ratio of the on-line center to off-line radiances; (c) together with CO2 gas absorption aerosol/cirrus cloud layer has differential scattering which may result in the modification of on-line to off-line radiance ratio which could lead a large bias in the total column CO2 retrieval. Approaches to correct such bias need further investigation. (d) CO2 retrieval requires good knowledge of the atmospheric temperature profile, e.g. approximately 1K RMS error in layer temperature, which is achievable from new atmospheric sounders in the near future; (e) the atmospheric path length, over which the CO2 absorption occurs, should be known in order to correctly interpret horizontal gradients of CO2 from the total column CO2 measurement; thus an additional sensor for surface pressure measurement needs to be attached for a complete measurement package.

Mao, Jianping↗

Using Cloud Top Pressures Derived from Raman Scattering in the UV for the OMI Total Column Ozone Retrievals

The OMI cloud pressure product is necessary for accounting for cloud effects on the mission- critical total ozone product. One of the OM1 cloud pressure algorithms uses UV measurements to derive cloud pressures from the high frequency structure of top- of-atmosphere reflectance caused by rotational Raman scattering (RRS) in the atmosphere. RRS results in filling-in of Fraunhofer lines in the backscatter UV spectra (also known as the Ring effect). The magnitude of filling-in of the Fraunhofer lines is roughly proportional to the average number of solar photon scatterings in the atmosphere above the clouds. This property of RRS is used to deduce an effective cloud pressure. The cloud pressure algorithm retrieves the cloud pressure and cloud fraction using a concept of the Mixed Lambert Equivalent Reflectivity (MLER) also used for the TOMS-V8 OM1 total column ozone algorithm. Currently, this OMI total column ozone algorithm utilizes information about cloud top pressures from a climatology based on IR measurements. The IR-derived cloud top pressure is known to be lower than UV-derived cloud top pressure because UV radiation penetrates clouds deeper than IR radiation. That is why the UV-derived cloud pressure may be more consistent withthe total ozone algorithm. We estimate total column ozone differences caused by replacing the cloud pressure climatology with cloud pressures retrieved from GOME data same as used for retrieval of ozone.

Joiner, J.↗

The cat vertebral column: stance configuration and range of motion

This study examined the configuration of the vertebral column of the cat during independent stance and in various flexed positions. The range of motion in the sagittal plane is similar across most thoracic and lumbar joints, with the exception of a lesser range at the transition region from thoracic-type to lumbar-type vertebrae. The upper thoracic column exhibits most of its range in dorsiflexion and the lower thoracic and lumbar in ventroflexion. Lateral flexion is limited to less than 5 degrees at all segments. The range in torsion is almost 180 degrees and occurs primarily in the midthoracic region, T4-T11. Contrary to the depiction in most atlases, the standing cat exhibits several curvatures, including a mild dorsiflexion in the lower lumbar segments, a marked ventroflexion in the lower thoracic and upper lumbar segments, and a profound dorsiflexion in the upper thoracic (above T9) and cervical segments. The curvatures are not significantly changed by altering stance distance but are affected by head posture. During stance, the top of the scapula lies well above the spines of the thoracic vertebrae, and the glenohumeral joint is just below the bodies of vertebrae T3-T5. Using a simple static model of the vertebral column in the sagittal plane, it was estimated that the bending moment due to gravity is bimodal with a dorsiflexion moment in the lower thoracic and lumbar region and a ventroflexion moment in the upper thoracic and cervical region. Given the bending moments and the position of the scapula during stance, it is proposed that two groups of scapular muscles provide the major antigravity support for the head and anterior trunk. Levator scapulae and serratus ventralis form the lateral group, inserting on the lateral processes of cervical vertebrae and on the ribs. The major and minor rhomboids form the medial group, inserting on the spinous tips of vertebrae from C4 to T4. It is also proposed that the hypaxial muscles, psoas major, minor, and quadratus lumborum could support the lumbar trunk during stance.

NASA Discipline Neuroscience↗

2004: Finite-Difference Time Domain Solution of Light Scattering by an Infinite Dielectric Column Immersed in an Absorbing Medium

The two-dimensional (2-D) finite-difference time domain (FDTD) method is applied to calculate light scattering and absorption by an arbitrarily shaped infinite column embedded in an absorbing dielectric medium. A uniaxial perfectly matched layer (UPML) absorbing boundary condition (ABC) is used to truncate the computational domain. The single-scattering properties of the infinite column embedded in the absorbing medium, including scattering phase functions, extinction and absorption efficiencies, are derived using an area integration of the internal field. An exact solution for light scattering and absorption by a circular cylinder in an absorbing medium is used to examine the accuracy of the 2-D UPML FDTD code. With use of a cell size of 1/120 incident wavelength in the FDTD calculations, the errors in the extinction and absorption efficiencies and asymmetry factors from the 2-D UPML FDTD are generally smaller than approx .1%. The errors in the scattering phase functions are typically smaller than approx .4%. Using the 2-D UPML FDTD technique, light scattering and absorption by long noncircular columns embedded in absorbing media can be accurately solved.

Sun, W.↗

Prospects for Precision Measurement of CO2 Column from Space

In order to address the problem of sources and sinks of CO2 measurements are needed on a global scale. Clearly a satellite is a promising approach to meeting this requirement. Unfortunately, most methods for making a CO2 measurement from space involve the whole column. Since sources and sinks at the surface represent a small perturbation to the total column one is faced with the need to measure the column with a precision better than 1%. No species has ever been measured from space at this level. We have developed over the last 3 years a small instrument based upon a Fabry-Perot interferometer that is very sensitive to atmospheric CO2 and has a high signal to noise ratio. We have tested this instrument in a ground based configuration and from aircraft platforms simulating operation from a satellite. We will present results from these tests and discuss ways that this promising new instrument could be used to improve our understanding of the global carbon budget.

Heaps, William S.↗

Column and Plate Compressive Strengths of Aircraft Structural Materials: Extruded 24S-T Aluminum Alloy

Column and plate compressive strengths of extruded 24S-T aluminum alloy were determined both within and beyond the elastic range from tests of thin-strip columns and local-instability tests of H-, Z-,and channel-section columns. These tests are part of an extensive research investigation to provide data on the' structural strength of various aircraft materials. The results are presented in the form of curves and charts that are suitable for use in the design and analysis of aircraft structures.

Heimerl, George J.↗

Development of a Fabry-Perot Interferometer for Ultra-Precise Measurements of Column CO2

A passive Fabry-Perot based instrument is described for detecting column CO2 through absorption measurements at 1.58 microns . In this design, solar flux reaches the instrument platform and is directed through two channels. In the first channel, transmittance fi5nges from a Fabry-Perot interferometer are aligned with CO2 absorption lines so that absorption due to CO2 is primarily detected. The second channel encompasses the same frequency region as the first, but is comparatively more sensitive to changes in the solar flux than absorption due to CO2. The ratio of these channels is sensitive to changes in the total CO2 column, but not to changes in solar flux. This inexpensive instrument will offer high precision measurements (error 4%) in a compact package. Design of this instrument and preliminary ground-based measurements of column CO2 are presented here as well as strategies for deployment on aircraft and satellite platforms.

Wilson, Emily L.↗

Dynamical and chemical contributions to variability in microwave limb sounder Arctic stratoshperic column ozone

Analyses of column ozone above 100 hPa (Col100) derived from Upper Atmosphere Research Satellite Microwave Limb Sounder (MLS) data in February/March 1992-1998 show that about half of the interannual variability in Col100 in the Arctic polar vortex in late winter results from interannual variability in chemical loss. A majority of the remainder results from interannual variability in day-to-day dynamical motions including adiabatic warming/cooling and poleward advection of underlying upper tropospheric subtropical air on short timescales, rather than from variations in descent rates and large-scale transport over the winters. The morphology of Col100 from MLS remains very similar to that in the dynamical models even in the years with most chemical ozone loss. The amount and character of day-to-day variability in dynamical models closely follows that in MLS Col100. Although the morphology of and day-to-day variability in Arctic column ozone are controlled by dynamical processes, chemical ozone loss was a major factor in producing both the low values of and the large interannual variability in Arctic column ozone observed during the 1990s.