Search NASA⌕ Search

SEARCH · Search NASA

Results for “configuration management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Autonomous light management system for a window and method of controlling light transmission

An autonomous light management system for a window includes an electrochromic film stack comprising an electrochromic layer on a first transparent electrode, an ion storage layer on a second transparent electrode, and an electrolyte sandwiched between the ion storage and electrochromic layers. The electrochromic film stack exhibits a transmissive state or an absorptive state depending on charging or discharging of the electrochromic layer. The light management system further comprises an array of power units disposed on a front surface of the electrochromic film stack, where each power unit comprises at least one solar microcell. Collectively, the solar microcells cover an area no greater than about 6% of a total area of the front surface. The array of power units is configured to control the charging and discharging of the electrochromic layer, thereby manipulating light transmission through the electrochromic film stack.

Yoder, Mikayla A.↗

Borehole Disposal: Update on the Science, Technology, and Potentially Suitable Radioactive Wastes - 20170

A recent Special Issue of the Energies Journal on Deep Borehole Disposal of Nuclear Waste has delivered a timely update on the science and technology of borehole disposal and the types of radioactive wastes it could potentially accommodate. The Special Issue papers discuss (i) circumstances under which a national waste management programme might wish to consider deep borehole disposal [1], (ii) a status report of deep borehole disposal options in Germany [2], (iii) the use of deep horizontal drill-holes in sedimentary, metamorphic or igneous rocks for disposal of spent nuclear fuel and high-level radioactive waste [3], (iv) the analysis of corrosion performance of engineered barrier systems [4], (v) a review of the potential cementing systems suitable for deep borehole disposal [5], (vi) the thermal evolution around heat-generating waste for a wide range of material properties and disposal configurations [6], (vii) a geochemical analysis of deep brines focussed on fluid-rock interactions [7], (viii) post-closure performance assessment calculations for deep borehole disposal of Cs/Sr capsules [8], and (ix) an example safety case for deep borehole disposal of nuclear wastes [9]. This paper provides an overview of the main findings from these publications and highlights some of the technological and scientific challenges that need to be overcome when developing a deep borehole disposal concept. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Stream Temperature Predictions for River Basin Management in the Pacific Northwest and Mid-Atlantic Regions Using Machine Learning

Stream temperature (Ts) is an important water quality parameter that affects ecosystem health and human water use for beneficial purposes. Accurate Ts predictions at different spatial and temporal scales can inform water management decisions that account for the effects of changing climate and extreme events. In particular, widespread predictions of Ts in unmonitored stream reaches can enable decision makers to be responsive to changes caused by unforeseen disturbances. In this study, we demonstrate the use of classical machine learning (ML) models, support vector regression and gradient boosted trees (XGBoost), for monthly Ts predictions in 78 pristine and human-impacted catchments of the Mid-Atlantic and Pacific Northwest hydrologic regions spanning different geologies, climate, and land use. The ML models were trained using long-term monitoring data from 1980–2020 for three scenarios: (1) temporal predictions at a single site, (2) temporal predictions for multiple sites within a region, and (3) spatiotemporal predictions in unmonitored basins (PUB). In the first two scenarios, the ML models predicted Ts with median root mean squared errors (RMSE) of 0.69–0.84 °C and 0.92–1.02 °C across different model types for the temporal predictions at single and multiple sites respectively. For the PUB scenario, we used a bootstrap aggregation approach using models trained with different subsets of data, for which an ensemble XGBoost implementation outperformed all other modeling configurations (median RMSE 0.62 °C).The ML models improved median monthly Ts estimates compared to baseline statistical multi-linear regression models by 15–48% depending on the site and scenario. Air temperature was found to be the primary driver of monthly Ts for all sites, with secondary influence of month of the year (seasonality) and solar radiation, while discharge was a significant predictor at only 10 sites. The predictive performance of the ML models was robust to configuration changes in model setup and inputs, but was influenced by the distance to the nearest dam with RMSE <1 °C at sites situated greater than 16 and 44 km from a dam for the temporal single site and regional scenarios, and over 1.4 km from a dam for the PUB scenario. Our results show that classical ML models with solely meteorological inputs can be used for spatial and temporal predictions of monthly Ts in pristine and managed basins with reasonable (<1 °C) accuracy for most locations.

54 ENVIRONMENTAL SCIENCES↗

Validation of the Community Land Model Version 5 over the Contiguous United States (CONUS) using in situ and remote sensing data sets

The Community Land Model (CLM) is an effective tool to simulate the biophysical and biogeochemical processes and their interactions with the atmosphere. Although CLM Version 5 (CLM5) constitutes various updates in these processes, its performance in simulating energy, water and carbon cycles over the Contiguous United States (CONUS) at scales which land surface changes and hydrometeorological and hydroclimatological applications are more locally relevant is yet to be assessed. In this study, we conducted three simulations at 0.125? during 1979-2018 over the CONUS using different configurations of CLM, namely CLM5-biogeochemistry (CLM5BGC), CLM4.5BGC, and CLM5-satellite phenology (CLM5SP). We validated and compared their simulations against multiple remote-sensed and in-situ datasets. Overall, the parametric and structural updates (e.g., carbon cost for nitrogen uptake, variable soil thickness, dry surface layer) in CLM5 improve its ability in capturing terrestrial biogeochemical dynamics. The low evapotranspiration in CLM5BGC is associated with biases in simulating vegetation phenological characteristics rather than soil water limitations. The mismatch between CLM5BGC-simulated peak leaf area index and reference data can be attributed to CLM5BGC's inability in simulating phenology of trees and grasses. The differences between CLM-simulated irrigation and reference estimates can be attributed to differences between processes represented in models and in reality, and uncertainties in input and validation datasets. Evaluation against observations at small catchments suggest that hydrologic parameters needed to be calibrated to improve simulations of runoff, especially subsurface runoff. Additional efforts are needed to incorporate spatially-distributed plant phenology and physiology parameters and regional-specific agricultural management practices (e.g., planting, harvest).

Cheng, Yanyan↗

Codisposal Waste Package Loading Options for DOE SNF and HLW PPT

The U.S. Department of Energy (DOE) is responsible for managing spent nuclear fuel (SNF) that is currently in, or will in the future come into, its possession. DOE must continue to safely store that SNF, transport it to an interim storage site or a repository, and dispose of it. These fuels come from a wide range of reactor types with various cladding materials and enrichments. Many of these reactors, now decommissioned, had unique design features, such as core configuration, fuel element and assembly geometry, moderator and coolant materials, operational characteristics, and neutron spatial and spectral properties, resulting in a large diversity of reactor and fuel designs. Because of the wide variety and conditions of SNF, a robust DOE Standard Canister was proposed that would confine radionuclides and preclude moderator. The DOE Standard Canister had four variations: 3.05-meter (10-foot) or 4.57-meter (15-foot) length, and 45.7-cm (18-inch) or 61.0-cm (24-inch) diameter. For ultimate disposal in the Yucca Mountain Repository, these canisters were to be grouped with 61.0-cm (24-inch) diameter high level waste (HLW) canisters in a 2.13-meter (84-inch) diameter co-disposal waste package. The smaller 45.7-cm (18-inch) diameter DOE Standard Canister could be placed in the middle of five HLW canisters. The larger 61.0-cm (24-inch) diameter DOE Standard Canister would take the place of one of the five HLW canisters on the outer ring in the co-disposal waste package. No DOE Standard Canisters have been loaded. A preliminary evaluation has estimated the number of elements of a fuel type that can fit into the different sizes of the DOE Standard Canister, but no definitive loading configuration has been selected. Changing the loading configuration could impact the number of loadable DOE Standard Canisters and the number of co-disposal waste packages needed for eventual disposition. This paper conveys the ranges of DOE Standard Canisters and HLW canisters that may be produced under certain conditions. It also examines the differences in the estimated number of co-disposal waste packages produced for eventual disposal when using different loading strategies in the DOE Standard Canister for Advanced Test Reactor (ATR), Peach Bottom, and High Flux Isotope Reactor (HFIR) SNF. Changing the loading configurations of ATR, Peach Bottom, and HFIR SNF slightly impacted the number of co-disposal waste packages that may be needed for ultimate disposal. The change in loading configuration was more impactful when a different canister was used, as opposed to varying the number of elements that could fit inside the same size canister. In one case, a reduction of co-disposal waste packages could be achieved by allowing mixing of short HLW canisters with long DOE Standard Canisters. The main conclusion from this analysis is that the ratio between HLW canisters and DOE Standard Canisters will drive the total number of co-disposal waste packages. If too many HLW canisters (i.e., more than five times the number of 18-inch DOE standard canisters) or DOE Standard Canisters are produced, some co-disposal waste packages may not have all positions filled. A co-disposal waste package may be filled with all HLW with no DOE Standard Canister, or a co-disposal waste package could be filled with a single DOE Standard Canister. A ratio that does not closely align to optimum could allow for the design of waste packages that hold just HLW canisters or just DOE SNF canisters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On High-Temperature Dynamometer Test Stand Development

RePED is a novel prototype alternator that has been designed and built to operate at 35 kW under 250 degrees C ambient temperature conditions. The operating efficiency will be measured using a 225-kW motor to drive the machine in a back-to-back configuration. The goal is to determine if the RePED alternator can deliver 35 kW at a rotational speed of 1,000 rpm while operating in 250 degrees C ambient temperature and have a minimum efficiency of 60%. Dynamometer testing of a high-temperature alternator for geothermal drilling presents several unique challenges, especially around maintaining and managing the various sources and types of energy passing through the system without impacting data quality. The objectives of this report are to (1) describe the test stand in detail, the relative orientation of each major component, and the data acquisition system and (2) discuss the behavior of the test stand components such that this report can serve as a reference document for future projects.

15 GEOTHERMAL ENERGY↗

Data Management for Digital Twin Implementation: Enhancing Existing SCADA Architecture for INL's CITRC Test Distribution System

The United States power grid will continue to experience stress from aging infrastructure, extreme weather, and increasing loads. In order to strengthen resiliency, researchers need to run tests and simulations that model real-life infrastructure. Idaho National Laboratory (INL) is creating a digital twin of its Critical Infrastructure Test Range Complex (CITRC). CITRC is an at-scale grid testbed which can be configured in utility-realistic distribution scenarios for a variety of tests, such as advanced grid protection and control. A digital twin of this infrastructure would support in-depth tests/simulations without risking physical consequences, before trialing devices under test at-scale. This project focuses on the data acquisition part of constructing a digital twin. It investigates the Supervisory Data Acquisition and Control (SCADA) system of CITRC and explores ways to utilize this system for the twin. Future “ideal” at-scale implementations such as upgraded equipment, modern communication protocols, and automation applications are also explored.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Advances in supervisory control strategies for a heat pump centric HVAC system − a comprehensive review on applications

There is an increase in research investigating the development and deployment of supervisory controllers that enable high efficiency electrically driven vapor compression heat pumps operating within grid interactive efficient buildings to provide demand side management. This paper reviews over sixty relevant case studies within this domain that focus on commercial off-the-shelf heat pumps whose primary task is providing space conditioning. The concept of a heat pump-centric heating, ventilation, and air-conditioning system is introduced, accompanied by a detailed overview of various kinds of electric heat pumps and building-level thermal energy storage configurations. Additionally, the different types of supervisory controller designs, including rule-based control and model predictive control, are discussed, along with the various methods for communication between a supervisory controller and a downstream heat pump’s local controller. A comparative analysis is conducted in order to categorize the reviewed case studies based on their system design, supervisory control algorithm, and validation methodology. This detailed analysis allows the review to establish current research trends, identify potential gaps, and suggest future directions for the development of this technology. Overall, the authors recommend that more future research be devoted to low-cost practical retrofits that allow for easy integration of active thermal energy storage within heat pump-centric heating, ventilation, and air-conditioning system systems that utilize direct expansion heat pumps. We also suggest more research into the development and deployment of supervisory controllers that can properly communicate with commercial off-the-shelf heat pump local controller available control inputs, e.g., zone temperature setpoint. Lastly, more rigorous experimental demonstrations of advanced supervisory control within real and or closed-loop, transient/ quasi-steady state environments are necessary to reduce industry wide skepticism of this technology.

Demand side management↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NH 4 OH Looping with Membrane CO 2 Absorber and Distributed Stripper for Enhanced Algae Growth

The University of Kentucky Center for Applied Energy (UK CAER) has devised a unique, integrated CO2 capture and utilization technology. CO2 from coal-fired power generation flue gas is first captured at half the operating cost of a typical aqueous CO2 capture system (CCS), distributed in an aqueous stream and then fixed by algae in bioreactors where the algae production is increased by 50% over that with a typical intermittent nutrient feeding system. Lower CCS operating cost is achieved by eliminating the flue gas pretreatment step for cooling and SO2 removal, eliminating steam extraction from the power generation steam cycle for solvent regeneration, and eliminating CO2 compression. Higher algae production is achieved by continuous, just-in-time nutrient feed to the bioreactors directly from a distributed solvent regenerator, which maintains the bioreactor pH for optimum growth. The process starts with a uniquely configured membrane absorber, where the flue gas is indirectly contacted with an ammonium hydroxide (NH4OH) solvent. Dissolved NH3 is attractive for both CO2 capture and as an algae nutrient. For CO2 capture it is inexpensive, has a low regeneration energy, is thermally- and oxidatively-stable and has a viscosity near that of water, which makes is easy to transport. Numerous studies have shown that the scrubbing capacity of NH3 is approximately 0.9-1.2 kg of CO2/kg of NH3, with a CO2 removal efficiency of ~99% and half the solvent regeneration energy than that of 30 wt% MEA[1, 2, 3]. NH3 is attractive as an algae nutrient due to its low cost. The rich NH4OH solvent is pumped to a set of distributed regenerators which are co-located with the algae bioreactors. Solvent pumping, transport and distribution reduces the balance of plant (BOP) cost compared to a typical aqueous CCS related to the flue gas duct and boost fan required to transport the flue gas. The energy required for the distributed solvent regeneration is supplied by solar-thermal panels eliminating the need for steam extraction from the power generation steam cycle. After solvent regeneration, the product stream contains both the CO2 captured from the flue gas and volatized NH3 from the solvent. This product stream is fed directly to the bioreactors, eliminating the need for compression of the CO2 stream. The relative amounts of CO2 and NH3 in the product stream are adjusted and controlled by a controlling the regeneration conditions (pressure and temperature). The continuous feed of the right ratio of nutrients overcomes the typical inhibition of algae growth resulting from frequent pH swings in the bioreactor due to unbalanced (intermittent) feeding systems for CO2 and N. Also, because the regenerators will operate at pressure and be located in close proximity to the bioreactors, there is no worry about pressure drop when sparging the gas into the algae. Sparging produces small bubbles which is beneficial for mass transfer efficiency. One known challenge when using an NH4OH solvent is high NH3 emission. Hydrophobic membranes are used for CO2 capture using an aqueous NH3 solution[4, 5] without the direct contact between flue gas and aqueous solution. Additionally, UK CAER CO2 capture and utilization process manages NH3 slip in three extra measures. First, NH3 slip is minimized by working with minimal species partial pressure, which is proportional to the concentration in the liquid. Hence, lowering the capture solvent concentration will lower the NH3 partial pressure. Second, UK CAER’s previous work has demonstrated that the addition of Zn2+ into NH3 solutions to chelate the NH3 can reduce NH3 volatility. Third, the configuration of the membrane CO2 absorber utilizes condensed water from the flue gas to continually wash the gas-side of the membrane to reduce fouling and recapture NH3 slip. Additional details about the UK CAER unique, integrated CO2 capture and utilization technology will be presented along with technology development plans. Diao, N., Q. Li, and Z. Fang. 2004. Heat transfer in ground heat exchangers with groundwater advection. International Journal of Thermal Sciences. 43: 1203-1211, He, Q., M. Chen, L. Meng, K. Liu, and W. Pan. 2004. Study on Carbon Dioxide Removal from Flue Gas by Absorption of Aqueous Ammonia. Western Kentucky University. Yeh, A.C., and H. Bai. 1999. Comparison of ammonia and monoethanolamine solvents to reduce CO2 greenhouse gas emissions. The Science of the Total Environment. 228: 121-133, Villeneuve, K., D. Roizard, J.C. Remigy, M. Iacono, and S. Rode. 2018. CO2 capture by aqueous ammonia with hollow fiber membrane contactors: Gas phase reactions and performance stability. Separation and Purification Technology, 199: 189-197, Toro Molina, C., and C. Bouallou. 2016. Carbon dioxide absorption by ammonia intensified with membrane contactors. Clean Techn Environ Policy 18, 2133–2146 (2016)

20 FOSSIL-FUELED POWER PLANTS↗

Energy Consumption and Cost Reduction of Future Light-Duty Vehicles through Advanced Vehicle Technologies: A Modeling Simulation Study Through 2050

The U.S. Department of Energy’s (DOE’s) Vehicle Technologies Office (VTO) and Hydrogen and Fuel Cell Technologies Office (HFTO) aim to develop sustainable, affordable and efficient technologies for transportation of goods and people. Translating investments in advanced transportation component technologies and powertrains to estimate vehicle-level fuel savings potential is critical for understanding DOE’s impact. In this work, we simulated technologies funded by VTO and HFTO for light duty vehicles. The simulations were performed across: Multiple powertrain configurations (i.e., conventional, power-split, extended-range electric vehicle, battery electric drive, and fuel-cell vehicles), Vehicle classes (i.e., compact car, midsize car, small sport utility vehicle [SUV], midsize SUV, and pickup trucks); and Fuels (i.e., gasoline, diesel, hydrogen, and battery electricity). These various technologies are assessed for six different timeframes: laboratory years 2015, 2020, 2025, 2030, and 2045. A delay of 5 years is assumed between laboratory year and model year (year technology is introduced into production). Finally, uncertainties are included for both technology performance and cost aspects by considering two cases: Low case, aligned with DOE technology manager estimates of expected original equipment manufacturer (OEM) improvements based on regulations, business as usual; and High case, aligned with aggressive technology advancements based on R&D targets developed through support by VTO & HFTO. These scenarios are not intended as predictions of future performances. The energy and cost impact of different technologies were estimated using Autonomie (www.autonomie.net), Argonne vehicle system simulation tool. Autonomie is a state-of-the-art vehicle system simulation tool used to assess the energy consumption, performance and cost of multiple advanced vehicle technologies across classes (from light to heavy duty), powertrains (from conventional to HEVs, FCEVs, PHEVs and BEVs), components and control strategies. Autonomie is packaged with a complete set of vehicle models for a wide range of vehicle classes, powertrain configurations and component technologies, including vehicle level and component level controls. These controls were developed and calibrated using dynamometer test data. Autonomie has been used to support a wide range of studies including analyzing various component technologies, sizing powertrains components for different vehicle requirements, comparing the benefits of powertrain configurations, optimizing both heuristic and route based vehicle energy control and predicting transportation energy use when paired with a traffic modeling tool such as POLARIS. This report documents the assumptions and estimates the vehicle-level energy consumption benefits and associated technology costs for the various types of light duty vehicles. All details of vehicle assumptions and simulation results are available in the spreadsheets accompanying this report.

33 ADVANCED PROPULSION SYSTEMS↗

A Comprehensive Simulation Study to Evaluate Future Vehicle Energy and Cost Reduction Potential

Under the umbrella of EERE’s Office of Sustainable Transportation, the U.S. Department of Energy’s (DOE) Vehicle Technologies Office (VTO) and Hydrogen and Fuel Cell Technologies Office (HFTO) seek to develop sustainable, affordable, and efficient technologies for transportation of goods and people. Translating investments in advanced transportation component technologies and powertrains to estimate the potential for vehicle-level fuel savings is critical to understanding DOE’s impact and success in this mission For this study, Argonne National Laboratory (Argonne) simulated technologies funded by VTO and HFTO for light-duty vehicles across the following: Powertrain configurations (conventional, power-split hybrid electric vehicle, extended-range electric vehicle, battery electric drive, and fuel-cell vehicles); Vehicle classes (compact car, mid-size car, small sport utility vehicle [SUV], mid-size SUV, and pickup truck); Fuels (gasoline, diesel, natural gas, hydrogen, and battery electricity). We assessed each technology for five different timeframes: laboratory years 2015 (reference), 2020, 2025, 2030, and 2045. We assumed a delay of 5 years between laboratory year and model year (i.e., the year the technology is introduced into production). Finally, we included uncertainties for both technology performance and cost by considering two cases (note that these cases are not intended as predictions of future performance): Low case , aligned with DOE technology manager estimates of expected original equipment manufacturer (OEM) improvements based on business as usual regulatory and market environments; High case , aligned with aggressive technology advancements based on research and development (R&D) targets developed through support by VTO and HFTO. We estimated the energy and cost impact of different technologies using Autonomie (Argonne undated), a state-of-the-art vehicle system simulation tool developed by Argonne and used to assess the energy consumption, performance, and cost of multiple advanced vehicle technologies. The tool comprises a complete set of vehicle models to assess impacts across a wide range of classes (from light- to heavy-duty), powertrain configurations (from conventional to hybrid electric vehicles [HEVs], fuel cell electric vehicles [FCEVs], plug-in hybrid electric vehicles [PHEVs], and battery electric vehicles [BEVs]), components, and control strategies, including vehicle-level and component-level controls developed and calibrated using dynamometer test data. Autonomie has been used to support a wide range of studies: analyzing various component technologies, sizing powertrain components to meet different vehicle requirements, comparing the benefits of powertrain configurations, optimizing both heuristic and route-based vehicle energy control, and predicting transportation energy use when paired with a traffic modeling tool such as POLARIS. This report documents the assumptions made and the vehicle-level energy consumption benefits and associated technology costs estimated for various types of light-duty vehicles. Details regarding vehicle assumptions and simulation results are available in the spreadsheets accompanying this report.

08 HYDROGEN↗

Visual Examination of Aluminum Containers for Extended Wet Storage of Non-Aluminum-Clad Spent Nuclear Fuel (FY 2021)

The goal of the Augmented Monitoring and Condition Assessment Program (AMCAP) program is to provide a condition assessment of the storage containers for non-aluminum-clad spent nuclear fuel (NASNF) in L Basin and demonstrate continued safe storage of all NASNF pending retrieval for ultimate disposition. The storage configuration of NASNF is vulnerable to inside-out corrosion attack. The approach being used in AMCAP is to develop and deploy examination methods for remote, in-situ inspection of the bundle storage in VTS and for OSC storage in the OSC racks. A method for Visual Examination (VE) using video-recording cameras was readied as part of the full-scale mockup development, and was deployed in L Basin for the initial condition assessment work. This report describes the development and the deployment of the VE for inspection of selected bundles in L Basin. The first deployment of the VE system was for visually examining five spent fuel bundles. Bundles were chosen based on their vulnerability in terms of inner fuel contents, history, storage duration, storage configuration, and possibility of inside out corrosion due to galvanic coupling of fuel cladding with the aluminum bundle wall.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Unsupervised Learning for Equitable DER Control: Preprint

In the context of managing distributed energy resources (DERs) within distribution networks (DNs), this work focuses on the task of developing local controllers. We propose an unsupervised learning framework to train functions that can closely approximate optimal power flow (OPF) solutions. The primary aim is to establish specific conditions under which these learned functions can collectively guide the network towards desired configurations asymptotically, leveraging an incremental control approach. The flexibility of the proposed methodology allows to integrate fairness-driven components into the cost function associated with the OPF problem. This addition seeks to mitigate power curtailment disparities among DERs, thereby promoting equitable power injections across the network. To demonstrate the effectiveness of the proposed approach, power flow simulations are conducted using the IEEE 37-bus feeder. The findings not only showcase the guaranteed system stability but also underscore its improved overall performance.

asymptotic stability↗

The HRA/Solarium Project: Feedback Based on 20 Years of Experience in Treatment of Medium Level Waste - 20185

Since the 1980's the management of the historical site of Mol has been transferred to the National Agency for Radioactive Waste and Enriched Fissile Materials (ONDRAF/NIRAS). Belgoprocess is entrusted by ONDRAF/NIRAS with the operational waste management and site remediation. One of the major challenges has been the characterization, treatment and conditioning of approximately 200 m{sup 3} of medium level waste. These waste packages were stored in poor conditions in storage vaults ('HRA') or concrete containers ('Solarium'). They have been produced in various research programs and reactor operations at the Belgian nuclear energy research centre SCK.CEN, isotope production, decontamination and dismantling operations from the 1960's up to the 1980's. Despite the limited volume, this historical waste consists of a great variation of waste characteristics and waste configurations. To tackle these liabilities, a new processing facility was built in the 1990's to allow safe transfers, handling, characterization and treatment of these packages. Also some auxiliary facilities have been built to deal with the by-products, like emptied concrete containers. The engineering of the installation, safety procedures and (characterization) methodology that has been developed generically have been proved to be successful. Nevertheless, the specific nature of some items made it necessary to organize a step-by-step treatment in distinct campaigns in which some relevant extra (safety) measures had to be taken into account. This dynamic approach made it possible to process a great variety of waste types in order to to ensure that this legacy is no longer left for subsequent generations. After about 20 years of operations, there has been a great build-up of experience and feed-back concerning the waste management of these specific waste streams. Some cases will be highlighted to specify the approach followed for treatment of e.g.: - Na/NaK containing equipment; - spent radioactive sources; - fuel element residues; - medium level waste originating from activation experiments; - radium bearing medium level waste originating from Ac-227 production research. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Optimization-based modeling and analysis of brine reflux osmotically assisted reverse osmosis for application toward zero liquid discharge systems

Significant amounts of high-salinity wastewater generated by water-intensive industrial activities such as shale oil and gas production have raised serious environmental concerns in recent years. Existing and emerging desalination technologies offer promise to manage these high salinity wastewater streams while simultaneously producing fresh water that could be diverted for beneficial uses. Osmotically assisted reverse osmosis (OARO) is one such emerging desalination technology capable of handling hypersaline brines and achieving high recoveries. However, rigorous modeling and analysis is needed to evaluate the process performance, energy consumption, and treatment cost of various OARO configurations. Here, this work presents detailed modeling and analysis of brine-reflux OARO (BR-OARO) system and compares it with other commonly discussed configurations, including cascading osmotically mediated reverse osmosis (COMRO), consecutive loop OARO, and split feed counterflow RO, through a cost optimization-based framework. We analyze and compare the treatment costs, membrane area, specific energy consumption, and design parameters of the aforementioned configurations with the ultimate goal of achieving zero liquid discharge (ZLD). The results indicate that the BR-OARO system with treatment cost of 5.1 US $/m 3 of produced water with 10% salinity outperforms other configurations in terms of number of stages needed, treatment cost, membrane area, and energy consumption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computation of graph hitting time moments; Chapel code implementation.

The project that developed this is unclassified, with the mandate to produce open source code. This code computes the hitting time moments of a graph using a linear algebra configuration. The goal of this work is to explore the performance capabilities of the Chapel programming language. Toward that end, we generate random adjacency matrices which represent a random graph. The code can also read in an adjacency matrix from a file. The main computation is the Conjugate Gradient method.SAND2020-12651 M. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Barrett, Richard↗