Search NASA⌕ Search

SEARCH · Search NASA

Results for “control methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

A Comparative Study of Two Widely Used Grid-Forming Droop Controls on Microgrid Small Signal Stability

Throughout history, two similar grid-forming droop controls are widely reported in literature—the single-and multi-loop droop controls. Although being very similar, the authors find that the dynamic performance and stability characteristics of each control method are very different in a microgrid. Compared with single-loop droop control, the multi-loop droop control is prone to be less damped and loses stability more easily under some circumstances. This paper provides a novel insight into the different dynamic responses of the two basic controls. It points out that the two similar controls adjust the angular frequency and voltage magnitude at different locations within the inverter, resulting in different coupling reactances that impact the dynamic response and stability of microgrids differently. The use of single-loop droop control results in a larger coupling reactance, which helps to improve dynamic response and stability. This novel insight is verified through full-order small signal analysis, offline electromagnetic transient simulation, and real-time hardware-in-the-loop simulation experiments. Results show that the microgrid has a larger small signal stability boundary when using single-loop droop control, and this difference increases as the value of an inverter’s inner filter inductance increases.

42 ENGINEERING↗

Network-Cognizant Voltage Droop Control for Distribution Grids

Our paper examines distribution systems with a high integration of distributed energy resources (DERs) and addresses the design of local control methods for real-time voltage regulation. Particularly, the paper focuses on proportional control strategies where the active and reactive output-powers of DERs are adjusted in response to (and proportionally to) local changes in voltage levels. The design of the voltage-active power and voltage-reactive power characteristics leverages suitable linear approximation of the AC power-flow equations and is network-cognizant; that is, the coefficients of the controllers embed information on the location of the DERs and forecasted non-controllable loads/injections and, consequently, on the effect of DER power adjustments on the overall voltage profile. We pursued a robust approach to cope with uncertainty in the forecasted non-controllable loads/power injections. Stability of the proposed local controllers is analytically assessed and numerically corroborated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Data-Driven Voltage Control Strategy for Distribution Grids With Distributed Energy Resources

Traditionally, distribution system control approaches have been model-based. The deployment of advanced metering infrastructure has provided electric utilities with the capability of data-driven control with real-time measurements. The shift from model-based to data-driven control represents a significant advancement in the management of distribution systems, offering a more adaptive approach to system control because of the ability to dynamically adapt to changing conditions without the need for system modeling. Here, in this paper, a behavioral data-driven control method is developed to provide voltage regulation to an actual distribution system by controlling the legacy devices and distributed energy resource (DER) assets. The studied distribution system has a load tap changer and three capacitor banks as the legacy devices and photovoltaic systems as the DERs. The performance of the proposed control algorithm is validated using a laboratory test bed setup considering multiple scenarios. The results show that the proposed control achieved 99% voltage regulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Decoupled Modulation Control

The objective of this research work is to develop decoupled modulation control methods for damping inter-area oscillations with low frequencies, so the damping control can be more effective and easier to design with less interference among different oscillation modes in the power system. A signal-decoupling algorithm was developed that can enable separation of multiple oscillation frequency contents and extraction of a “pure” oscillation frequency mode that are fed into Power System Stabilizers (PSSs) as the modulation input signals. As a result, instead of introducing interferences between different oscillation modes from the traditional approaches, the output of the new PSS modulation control signal mainly affects only one oscillation mode of interest. The new decoupled modulation damping control algorithm has been successfully developed and tested on the standard IEEE 4-machine 2-area test system and a minniWECC system. The results are compared against traditional modulation controls, which demonstrates the validity and effectiveness of the newly-developed decoupled modulation damping control algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A High Power Density Single-Phase PWM Rectifier with Active Ripple Energy Storage

It is well known that there exist second-order harmonic current and corresponding ripple voltage on dc bus for single phase PWM rectifiers. The low frequency harmonic current is normally filtered using a bulk capacitor in the bus which results in low power density. This paper proposed an active ripple energy storage method that can effectively reduce the energy storage capacitance. The feed-forward control method and design considerations are provided. Simulation and 15 kW experimental results are provided for verification purposes.

25 ENERGY STORAGE↗

Coordinated control design and verification of the HTR-PM plant - 18485

Through multi-modular scheme, i.e. the superheated steam flows produced by multiple MHTGR-based nuclear supplying system (NSSS) modules are combined together to drive a common thermal load, the inherent safety feature of MHTGR can be applicable to the large-scale nuclear plants at any desired power ratings. Since the plant power control technique of classical single-modular plants cannot be directly applied to multi-modular plants, it is necessary to develop the power control method of the multi-modular plants. In this paper, the plant power control strategy of the two-modular HTR-PM plant, i.e. the first under-constructed multi-modular high temperature gas-cooled nuclear plant in the world is given, which includes both the feedback loops and control algorithms. Then, the control strategy is verified through numerical simulation, and the simulation results in the cases of plant power step and ramp show the satisfactory performance of this control strategy. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data-driven based coordinated smart inverter control for distributed energy resources

Smart inverters (SI) for distributed energy resources (DER) are becoming popular since they have the ability to stabilize as well as restore the voltage and frequency of power systems. Aiming at establishing the mathematical models combined with SI control methods, multiple optimization methods are developed. However, the computational complexity of solving such a mathematical model with various uncertainties limits the real-time application of the SI control. To conquer this challenge, a data-driven-based SI control approach is developed to achieve coordinated control in the high penetration DER system. First, an optimization problem for maximizing the active power generation and minimizing the power loss is designed using the Volt/VAR control. To reduce the time consumption, the recurrent neural network (RNN) is proposed to model the relationship between the uncertainties and control actions during the offline site. The RNN with different sub-structures such as the long short-term memory cell and gated recurrent unit cell are included to enrich the diversity of features. In the last stage, different experiment comparisons, including multiple uncertainties maps and stateof- art machine learning methods, are conducted to verify the effectiveness of the proposed method based on the IEEE 123 bus power system. The results demonstrate that the proposed method can effectively achieve a rapid and coordinated control with a lower error rate.

Qiu, Wei↗

Model-Free Voltage Control of Active Distribution System with PVs Using Surrogate Model-Based Deep Reinforcement Learning

Accurate knowledge of the distribution system topology and parameters is required to achieve good voltage control performance, but this is difficult to obtain in practice. This paper proposes a physical-model-free voltage control method based on a surrogate-model-enabled deep reinforcement learning approach. Specifically, a surrogate model is trained in a supervised manner using the recorded limited number of historical data to learn the relationship between the power injections and voltage fluctuations of each node. Then, the deep reinforcement learning algorithm is applied to learn an optimal control strategy from the experiences obtained by continuous interactions with the surrogate model. The proposed method can achieve physical-model-free control of unbalanced distribution network and inform real-time decisions to deal with fast voltage fluctuations caused by the rapid variation of PV generation. Simulation results on an unbalance IEEE 123-bus system show that the proposed method can achieve similar performance as that of perfect physical-model-based approaches while being advantageous over other traditional methods.

active distribution network↗

Farnesoid-X-receptor expression in monocrotaline-induced pulmonary arterial hypertension and right heart failure

Objective: The farnesoid-X-receptor (FXR) is a metabolic nuclear receptor superfamily member that is highly expressed in enterohepatic tissue and is also expressed in the cardiovascular system. Multiple nuclear receptors, including FXR, play a pivotal role in cardiovascular disease (CVD). Pulmonary arterial hypertension (PAH) is an untreatable cardiovascular system disease that leads to right heart failure (RHF). However, the potential physiological/pathological roles of FXR in PAH and RHF are unknown. We therefore compared FXR expression in the cardiovascular system in PAH, RHF and a control. Methods and results: Hemodynamic parameters and morphology were assessed in blank solution-exposed control, monocrotaline (MCT)-exposed PAH (4 weeks) and RHF (7 weeks) Sprague–Dawley rats. Real-time reverse transcription polymerase chain reaction (real-time RT-PCR), Western blot (WB), immunohistochemistry (IHC) analysis and immunofluorescence (IF) analysis were performed to assess FXR levels in the lung and heart tissues of MCT-induced PAH and RHF rats. In normal rats, low FXR levels were detected in the heart, and nearly no FXR was expressed in rat lungs. However, FXR expression was significantly elevated in PAH and RHF rat lungs but reduced in PAH and RHF rat right ventricular (RV) tissues. FXR expression was reduced only in RHF rat left ventricular (LV) tissues. Conclusions: The differential expression of FXR in MCT-induced PAH lungs and heart tissues in parallel with PAH pathophysiological processes suggests that FXR contributes to PAH. - Highlights: • FXR was expressed in rat lung and heart tissues. • FXR expression increased sharply in the lung tissues of PAH and RHF rats. • FXR expression was reduced in PAH and RHF rat RV tissue. • FXR expression was unaltered in PAH LV but reduced in RHF rat LV tissue. • FXR expression was prominent in the neovascularization region.

60 APPLIED LIFE SCIENCES↗

Anticipatory Monitoring and Control of Complex Systems using a Fuzzy based Fusion of Support Vector Regressors

This paper places itself in the realm of anticipatory systems and envisions monitoring and control methods being capable of making predictions over system critical parameters. Anticipatory systems allow intelligent control of complex systems by predicting their future state. In the current work, an intelligent model aimed at implementing anticipatory monitoring and control in energy industry is presented and tested. More particularly, a set of support vector regressors (SVRs) are trained using both historical and observed data. The trained SVRs are used to predict the future value of the system based on current operational system parameter. The predicted values are then inputted to a fuzzy logic based module where the values are fused to obtain a single value, i.e., final system output prediction. The methodology is tested on real turbine degradation datasets. The outcome of the approach presented in this paper highlights the superiority over single support vector regressors. In addition, it is shown that appropriate selection of fuzzy sets and fuzzy rules plays an important role in improving system performance.

47 OTHER INSTRUMENTATION↗

Real Time Optimal Control of Supercapacitor Operation for Frequency Response

Supercapacitors are gaining wider applications in power systems due to fast dynamic response. Utilizing supercapacitors by means of power electronics interfaces for power compensation is a proven effective technique. For applications such as requency restoration if the cost of supercapacitors maintenance as well as the energy loss on the power electronics interfaces are addressed. It is infeasible to use traditional optimization control methods to mitigate the impacts of frequent cycling. This paper proposes a Front End Controller (FEC) using Generalized Predictive Control featuring real time receding optimization. The optimization constraints are based on cost and thermal management to enhance to the utilization efficiency of supercapacitors. A rigorous mathematical derivation is conducted and test results acquired from Digital Real Time Simulator are provided to demonstrate effectiveness.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimal Operation of a Plug-In Hybrid Vehicle

In this work, we present a convex optimization control method that has been shown in simulations to increase the fuel efficiency of a plug-in hybrid electric vehicle by over 10%. Using information on energy demand and energy use profiles, the problem is defined to preferentially use battery resources sourced from the grid over petroleum resources. We pose the general nonlinear optimal resource management problem over a predetermined route as a convex optimization problem using a reduced model of the vehicle. This problem is computationally efficient enough to be optimized “on the fly” on the on-board vehicle computer and is thus able to adapt to changing vehicle conditions in real time. Lastly, using this reduced model to generate control inputs for the detailed vehicle simulator autonomie, we record efficiency gains of over 10% as compared to the industry standard charge depleting charge sustaining controller over synthetic mixed urban-suburban routes.

02 PETROLEUM↗

Method of making controlled morphology metal-oxides

A method of making metal oxides having a preselected morphology includes preparing a suspension that includes a solvent, polymeric nanostructures having multiplicities of hydroxyl surface groups and/or carboxyl surface groups, and a metal oxide precursor. The suspension has a preselected ratio of the polymeric nanostructures to the metal oxide precursor of at least 1:3, the preselected ratio corresponding to a preselected morphology. Subsequent steps include depositing the suspension onto a substrate, removing the solvent to form a film, removing the film from the substrate, and annealing the film to volatilize the polymeric nanostructures and convert the metal oxide precursor to metal oxide nanoparticles having the preselected morphology or to a metal oxide nanosheet including conjoined nanoparticles having the preselected morphology.

36 MATERIALS SCIENCE↗

Control system and method for tapered structure construction

A control system for forming a tapered structure includes a sensor providing feedback for a machine for forming a tapered structure including at least three rolls having at least one bend roll and at least two guide rolls. The guide rolls may include rollette banks having a plurality of rollettes. The machine may also include an adjustment mechanism to position at least one of the rolls, where a diameter of the tapered structure being formed is controlled by relative positions of the rolls. The machine may also include a joining element to join edges of a stock of material together as it is rolled through the rolls to form the tapered structure. The control system may also include a controller to receive feedback from the sensor and to send a control signal based on the feedback to the adjustment mechanism for positioning at least one of the rolls.

Takata, Rosalind K.↗

Control system and method for tapered structure construction

A control system for forming a tapered structure includes a sensor providing feedback for a machine for forming a tapered structure including at least three rolls having at least one bend roll and at least two guide rolls. The guide rolls may include rollette banks having a plurality of rollettes. The machine may also include an adjustment mechanism to position at least one of the rolls, where a diameter of the tapered structure being formed is controlled by relative positions of the rolls. The machine may also include a joining element to join edges of a stock of material together as it is rolled through the rolls to form the tapered structure. The control system may also include a controller to receive feedback from the sensor and to send a control signal based on the feedback to the adjustment mechanism for positioning at least one of the rolls.

Takata, Rosalind K.↗

Control systems and methods using parametric driver model

A control system of a vehicle includes: a target speed module configured to, using a parametric driver model and based on first driver parameters, second driver parameters, and vehicle parameters, determine a target vehicle speed trajectory for a future predetermined period; a driver parameters module configured to determine the first driver parameters based on conditions within a predetermined distance in front of the vehicle; and a control module configured to adjust at least one actuator of the vehicle based on the target vehicle speed trajectory and a present vehicle speed.

Hegde, Bharatkumar↗

The Energy and Operational Impacts of Using 0-10V Control for LED Streetlights

Lighting systems have historically utilized either a proprietary control method, or one of a handful of standardized methods (e.g., 0-10V, DALI, DMX512) aimed at facilitating vendor interoperability. The utility and market success of the standardized methods has been limited for a variety of reasons. Although 0-10V is presently the most commonly available control interface for indoor and outdoor products in North America – even after the emergence of LED products and “connected lighting systems” with more modern network interfaces and luminaire-level sensors and intelligence – the use of 0-10V methods has significant tradeoffs. For instance, it is difficult to predict relative luminaire light output and input power at any particular control voltage, and performance across luminaires is inconsistent. This study characterizes 23 LED streetlights that claimed dimmability via a 0-10V interface, quantifies the performance variation found in market-available LED drivers, and explores the potential impact of the most recent 0-10V voluntary standard (ANSI C137.1-2022). Notably, the tested products were all manufactured prior to the release of this standard, and thus do not make compliance claims. Variation in response to 0-10V control voltages was expected to be more significant across different make/model luminaires than different units of the same make/model; the test population was structured based on this expectation. The 23 tested luminaires comprised 21 unique make/model streetlights from 14 different manufacturers. Three samples of one make/model streetlight were included in the test population to facilitate a limited exploration of unit-to-unit variation. The 21 unique make/model luminaires contained 20 unique make/model LED drivers from eight different driver manufacturers. Luminaire input power and current were measured at 11 control voltages (0.5 V and 1–10 V in 1 V increments).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Systems, methods and computer program products for collaborative agent control

Systems, methods and unmanned agents for collaboratively controlling agents in a collaborative network by one or more agents continuously simulating numeric models of one or more other agents in the network to dramatically reduce the computational bandwidth required between agents, and improve the quality of shared estimates of the agent locations as well as the locations and characteristics of other objects of interest, e.g. targets. Bandwidth is reduced by using the models to intelligently filter data before communicating.

Buerger, Stephen↗