Search NASA⌕ Search

SEARCH · Search NASA

Results for “conversion methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Methodology for the comparative assessment of the Satellite Power System (SPS) and alternative technologies

The energy systems concerned are the satellite power system, several coal technologies, geothermal energy, fission, fusion, terrestrial solar systems, and ocean thermal energy conversion. Guidelines are suggested for the characterization of these systems, side-by-side analysis, alternative futures analysis, and integration and aggregation of data. A description of the methods for assessing the technical, economic, environmental, societal, and institutional issues surrounding the development of the selected energy technologies is presented.

Wolsko, T.↗

Forward and reverse transfer function model synthesis

A process for synthesizing a mathematical model for a linear mechanical system using the forward and reverse Fourier transform functions is described. The differential equation for a system model is given. The Bode conversion of the differential equation, and the frequency and time-domain optimization matching of the model to the forward and reverse transform functions using the geometric simplex method of Nelder and Mead (1965) are examined. The effect of the window function on the linear mechanical system is analyzed. The model is applied to two examples; in one the signal damps down before the end of the time window and in the second the signal has significant energy at the end of the time window.

Houghton, J. R.↗

Methods and apparatus for using gas and liquid phase cathodic depolarizers

The invention provides methods for using gas and liquid phase cathodic depolarizers in an electrochemical cell having a cation exchange membrane in intimate contact with the anode and cathode. The electrochemical conversion of cathodic depolarizers at the cathode lowers the cell potential necessary to achieve a desired electrochemical conversion, such as ozone evolution, at the anode. When gaseous cathodic depolarizers, such as oxygen, are used, a gas diffusion cathode having the cation exchange membrane bonded thereto is preferred. When liquid phase cathodic depolarizers are used, the cathode may be a flow-by electrode, flow-through electrode, packed-bed electrode or a fluidized-bed electrode in intimate contact with the cation exchange membrane.

Murphy, Oliver J.↗

Modeling Electro-Optic Frequency Comb Generation as a Pump Source for Quantum Communications

The Quantum Communications group at NASA GRC is focused on developing technologies and system architectures to enable future space-based quantum networks. High-repetition rate pulsed pump lasers are needed because the signal on the quantum channel cannot be amplified, hence entanglement generation rates can only be increased through high-rate pumping. Additionally, tunability in center frequency, pulse width, and repetition rate allows for a wider parameter space over which to optimize quantum channel frequency conversion efficiency, joint spectral engineering, and channel synchronization for high-fidelity entanglement swapping –a necessary stepping-stone towards quantum repeater development. One of the most flexible methods for high-repetition rate pulse generation is through spectral shaping–generating a frequency comb from a continuous-wave(CW)laser using electro-optic modulators (EOMs). As a result, this project focuses on analytically modeling and simulating the effects various EOMs such as phase and intensity modulators have on a CW source. Generating a tunable frequency comb as the pump source allows us to conveniently fine-tune the central frequency, repetition rate, and the spectral shape of our source to match the strict optimal parameters for any given entanglement source considered in the future. These models and simulations are to be used for comparison purposes for future experiments as well as for providing the Quantum Communications group a convenient tool to understand the effects of manipulating various parameters have on the outgoing frequency comb.

Electro-optic modulator↗

A Preliminary Study on the Feasibility of Large Language Models for Detecting Micro-Behaviors Among Team Members in Space Missions

Large-language models (LLMs) have been recently used for spoken language understanding (SLU) to infer meaning and semantics from speech in tasks such as speaker intent and sentiment classification. Due to being trained on large amounts of data, and their ability to understand context and relationships between words, LLMs are competent, enabling them to generalize across tasks without requiring many task-specific training samples. This research examines the feasibility of few-shot learning in LLMs for detecting subtle, brief, and possibly unconscious interactions between team members, called ``micro-behaviors," and provides insights into the appropriate design of LLMs for this task. Our data came from 5 teams participating in a 45-day mission at the US National Aeronautics and Space Administration’s (NASA) Human Exploration Research Analog (HERA). More specifically we used data collected from team interaction battery (TIB) tasks teams performed five times in-mission which comprise an average 1.5 hours of conversation data per day. Micro-behaviors were coded according to an adapted version of Smith & Griffins (2022) theoretical framework in terms of Violation (i.e., presence of valenced behavior, uplifting/positive or discouraging/negative), Intensity (i.e., force of behavior in terms of how uplifting or discouraging is the behavior), and Intent (i.e., motive of the behavior in terms of whether it was deliberate or unintentional). We explore the ability of LLMs to detect the presence and intensity of micro-behaviors. We examine employing and fine-tuning readily available LLMs (i.e., RoBERTa, DistilBERT), as well as prompting state-of-the-art sequence classification models (i.e., Llama-2, Llama-3). In a total of 13,058 conversational turns (17.8% uplifting, 3.3% discouraging, 75.76% neutral, 3.14% nulls), we compute the macro F1-score of the 3-way micro-behavior classification task (i.e., classifying among uplifting, discouraging, and neutral; 33% chance). Results indicate that the RoBERTa model achieves a F1-score of 36.2% (uplift: 43.3% precision (P), 15.1% recall (R); discourage: 20% P, 0.5% R). These results significantly improve when we augment the data via paraphrasing in the RoBERTa model, reaching a 41.2% macro F1-score (uplift: 37.7% P, 86.3% R; discourage: 3.5% P, 1.8% R). Finally, the Llama-2 model with 3-shot prompting yields 38% macro F1-score (uplift: 28.7% P, 20% R; discourage: 7.2% P, 18% R), which is slightly better compared to the RoBERTa model without data augmentation, highlighting the effectiveness of sequence classification models in detecting minority classes with a small sample size. Findings indicate that LLMs hold potential to detect subtle behaviors in conversations, which could be valuable in assessing team behavior in space exploration missions. Future studies will evaluate the performance of different LLM prompting strategies or fine-tuning methods.

Ankush Raut↗

A fast-reacting and versatile optokinetic stimulus pattern by computer graphics with application examples

A computer graphics method for the generation of horizontally moving vertical stripes which serve as stimuli for optokinetic nystagmus is presented. The pattern is generated by the successive addition of a constant in a digital register, leading to its periodic overflow. Digital to analog conversion of the register contents results in a staircase waveform, which is converted into a pattern of vertical lines on a CRT. The addition of any number to the reference buffer shifts all lines uniformly, so that the group velocity of the pattern is easily controlled. The computer controlled display allows an accurate realization of a commanded velocity profile with practically no time delay and facilitates study under conditions of variable feedback. The display software can be easily modified to limit stimulation to a selected area of the moving retina, and the method has been used to simulate central scotomata. It is pointed out that the technique, while more accurate, versatile and responsive than a rotating drum device, may be less useful in experiments requiring a wide field display.

Yasui, S.↗

The properties of and analytical methods for detection of LiOH and Li2CO3

Lithium hydroxide (LiOH) is used as a CO2 absorbent in the Shuttle Extravehicular Mobility Unit (EMU) Portable Life Support System (PLSS). The first objective was to survey parameters that may be used to indicate conversion of LiOH to Li2CO3, and compile a list of all possible properties, including physical, chemical, structural, and electrical, that may serve to indicate the occurrence of reaction. These properties were compiled for the reactant (LiOH), the intermediate monohydrate compound (LiOH.H2O), and the final product (Li2CO3). The second objective was to survey measurement and analytical techniques which may be used in conjunction with each of the properties identified above, to determine the extent of conversion of LiOH to Li2CO3. Both real-time and post-run techniques were of interest. The techniques were also evaluated in terms of complexity, technology readiness, materials/equipment availability, and cost, where possible.

Selvaduray, Guna↗

Barium light source method and apparatus

Visible light emission is obtained from a plasma containing elemental barium including neutral barium atoms and barium ion species. Neutral barium provides a strong green light emission in the center of the visible spectrum with a highly efficient conversion of electrical energy into visible light. By the selective excitation of barium ionic species, emission of visible light at longer and shorter wavelengths can be obtained simultaneously with the green emission from neutral barium, effectively providing light that is visually perceived as white. A discharge vessel contains the elemental barium and a buffer gas fill therein, and a discharge inducer is utilized to induce a desired discharge temperature and barium vapor pressure therein to produce from the barium vapor a visible light emission. The discharge can be induced utilizing a glow discharge between electrodes in the discharge vessel as well as by inductively or capacitively coupling RF energy into the plasma within the discharge vessel.

Curry, John J.↗

High-Speed, High-Resolution Time-to-Digital Conversion

This innovation is a series of time-tag pulses from a photomultiplier tube, featuring short time interval between pulses (e.g., 2.5 ns). Using the previous art, dead time between pulses is too long, or too much hardware is required, including a very-high-speed demultiplexer. A faster method is needed. The goal of this work is to provide circuits to time-tag pulses that arrive at a high rate using the hardwired logic in an FPGA - specifically the carry chain - to create what is (in effect) an analog delay line. High-speed pulses travel down the chain in a "wave." For instance, a pulse train has been demonstrated from a 1- GHz source reliably traveling down the carry chain. The size of the carry chain is over 10 ns in the time domain. Thus, multiple pulses will travel down the carry chain in a wave simultaneously. A register clocked by a low-skew clock takes a "snapshot" of the wave. Relatively simple logic can extract the pulses from the snapshot picture by detecting the transitions between logic states. The propagation delay of CMOS (complementary metal oxide semiconductor) logic circuits will differ and/or change as a result of temperature, voltage, age, radiation, and manufacturing variances. The time-to-digital conversion circuits can be calibrated with test signals, or the changes can be nulled by a separate on-die calibration channel, in a closed loop circuit.

Katz, Richard↗

Theoretcial studies of solar-pumped lasers

A method of pumping a COhZ laser by a hot cavity was demonstrated. The cavity, heated by solar radiation, should increase the efficiency of solar pumped lasers used for energy conversion. Kinetic modeling is used to examine the behavior of such a COhZ laser. The kinetic equations are solved numerically vs. time and, in addition, steady state solutions are obtained analytically. The effect of gas heating filling the lower laser level is included. The output power and laser efficiency are obtained as functions of black body temperature and gas ratios (COhZ-He-Ar) and pressures. The values are compared with experimental results.

Harries, W. L.↗

Signal Processing and Calibration of Continuous-Wave Focused CO2 Doppler Lidars for Atmospheric Backscatter Measurement

Two continuous-wave(CW)focused C02 Doppler lidars (9.1 and 10.6 micrometers) were developed for airborne in situ aerosol backscatter measurements. The complex path of reliably calibrating these systems, with different signal processors, for accurate derivation of atmospheric backscatter coefficients is documented. Lidar calibration for absolute backscatter measurement for both lidars is based on range response over the lidar sample volume, not solely at focus. Both lidars were calibrated with a new technique using well-characterized aerosols as radiometric standard targets and related to conventional hard-target calibration. A digital signal processor (DSP), a surface acoustic and spectrum analyzer and manually tuned spectrum analyzer signal analyzers were used. The DSP signals were analyzed with an innovative method of correcting for systematic noise fluctuation; the noise statistics exhibit the chi-square distribution predicted by theory. System parametric studies and detailed calibration improved the accuracy of conversion from the measured signal-to-noise ratio to absolute backscatter. The minimum backscatter sensitivity is approximately 3 x 10(exp -12)/m/sr at 9.1 micrometers and approximately 9 x 10(exp -12)/m/sr at 10.6 micrometers. Sample measurements are shown for a flight over the remote Pacific Ocean in 1990 as part of the NASA Global Backscatter Experiment (GLOBE) survey missions, the first time to our knowledge that 9.1-10.6 micrometer lidar intercomparisons were made. Measurements at 9.1 micrometers, a potential wavelength for space-based lidar remote-sensing applications, are to our knowledge the first based on the rare isotope C-12 O(2)-18 gas.

Rothermel, Jeffry↗

Practical aspects of plasma processes in thermionic energy converters

Over a decade of cesium vapor thermionic converter research has yielded sufficient understanding of the basic plasma processes to permit application of this understanding to improvement of converter performance. A performance index is defined which relates such converter improvements directly to increases in system performance. A prime practical objective of current research is to reduce or eliminate the arc potential drop presently required to sustain the plasma in the ignited cesium diode. This will substantially increase the energy conversion efficiency, and will permit operation at substantially lower emitter temperatures without requiring lower collector (heat rejection) temperature. Present work is concentrating on evaluating and reducing to practice the several methods employing auxiliary ion sources to eliminate the arc drop which were demonstrated over a decade ago: i.e., various ignited and unignited triode concepts, and the pulse-enhanced diode and triode. These methods are reviewed in light of present understanding and recent experimental data.

Rasor, N. S.↗

Silicon solar cell process development, fabrication and analysis

The fabrication of solar cells from several unconventional silicon materials is described, and cell performance measured and analyzed. Unconventional materials evaluated are edge defined film fed grown (EFG), heat exchanger method (HEM), dendritic web grown, and continuous CZ silicons. Resistivity, current voltage, and spectral sensitivity of the cells were measured. Current voltage was measured under AM0 and AM1 conditions. Maximum conversion efficiencies of cells fabricated from these and other unconventional silicons were compared and test results analyzed. The HEM and continuous CZ silicon were found to be superior to silicon materials considered previously.

Minahan, J. A.↗

A Nomographic Methodology for Use in Performance Trade-Off Studies of Parabolic Dish Solar Power Modules

A simple graphical method was developed to undertake technical design trade-off studies for individual parabolic dish models comprising a two-axis tracking parabolic dish with a cavity receiver and power conversion assembly at the focal point. The results of these technical studies are then used in performing the techno-economic analyses required for determining appropriate subsystem sizing. Selected graphs that characterize the performance of subsystems within the module were arranged in the form of a nomogram that would enable an investigator to carry out several design trade-off studies. Key performance parameters encompassed in the nomogram include receiver losses, intercept factor, engine rating, and engine efficiency. Design and operation parameters such as concentrator size, receiver type (open or windowed aperture), receiver aperture size, operating temperature of the receiver and engine, engine partial load characteristics, concentrator slope error, and the type of reflector surface, are also included in the graphical solution. Cost considerations are not included.

Selcuk, M. K.↗

Comparison of the US and Russian Cycle Ergometers

The purpose of this study was to compare the U.S. and Russian cycle ergometers focusing on the mechanical differences of the devices and the physiological differences observed while using the devices. Methods: First, the mechanical loads provided by the U.S. Cycle Ergometer with Vibration Isolation System (CEVIS) and the Russian Veloergometer were measured using a calibration dynamometer. Results were compared and conversion equations were modeled to determine the actual load provided by each device. Second, ten male subjects (32.9 +/- 6.5 yrs, 180.6 +/- 4.4 cm; 81.9 +/- 6.9 kg) experienced with both cycling and exercise testing completed a standardized submaximal exercise test protocol on CEVIS and Veloergometer. The exercise protocol involved 8 sub-maximal workloads each lasting 3 minutes for a total of 24 minutes per session, or until the end of the stage when the subject reached 85% of peak oxygen consumption or age-predicted maximum heart rate (220 - age). The workload started at 50 Watts (W), increased to 100 W, and then increased 25 W every 3 minutes until reaching a peak workload of 250 W. Physiological variables were then compared at each workload by repeated measures ANOVA or paired t-tests (p<0.05). Results: While both CEVIS and Veloergometer produced significantly lower workloads than the displayed workload, CEVIS produced even lower loads than Veloergometer (p<0.05) at each indicated workload. Despite this fact, the only physiological variables that showed a significant difference between the ergometers were VE (125 - 250W), VO2 (175 and 250 W), and VCO2 (175 W). All other physiological data were not statistically different between CEVIS and Veloergometer. Conclusion: Although workloads were different between ergometers, relatively few physiological differences were observed. Therefore, CEVIS workloads of 87.5 - 262.5 W can be rounded to the nearest 25 W increment and performed on the Veloergometer.

Norcross, Jason↗

ECUT: Energy Conversion and Utilization Technologies program - Biocatalysis research activity

The activities of the Biocatalysis Research Activity are organized into the Biocatalysis and Molecular Modeling work elements and a supporting planning and analysis function. In the Biocatalysis work element, progress is made in developing a method for stabilizing genetically engineered traits in microorganisms, refining a technique for monitoring cells that are genetically engineered, and identifying strains of fungi for highly efficient preprocessing of biomass for optimizing the efficiency of bioreactors. In the Molecular Modeling work element, a preliminary model of the behavior of enzymes is developed. A preliminary investigation of the potential for synthesizing enzymes for use in electrochemical processes is completed. Contact with industry and universities is made to define key biocatalysis technical issues and to broaden the range of potential participants in the activity. Analyses are conducted to identify and evaluate potential concepts for future research funding.

Wilcox, R.↗

Supported transition metal catalysts for para- to ortho-hydrogen conversion

The main goal of this study was to develop and improve on existing catalysts for the conversion of ortho- to para-hydrogen. Starting with a commercially available Air Products nickel silicate, which had a beta value of 20, we were trying to synthesize catalysts that would be an improvement to AP. This was accomplished by preparing silicates with various metals as well as different preparation methods. We also prepared supported ruthenium catalysts by various techniques using several metal precursors to improve present technology. What was also found was that the activation conditions prior to catalytic testing was highly important for both the silicates and the supported ruthenium catalysts. While not the initial focus of the research, we made some interesting observations into the adsorption of H2 on ruthenium. This helped us to get a better understanding of how ortho- to para-H2 conversion takes place, and what features in a catalyst are important to optimize activity. Reactor design was the final area in which some interesting conclusions were drawn. As discussed earlier, the reactor catalyst bed must be constructed using straight 1/8 feet OD stainless steel tubing. It was determined that the use of 1/4 feet OD tubing caused two problems. First, the radius from the center of the bed to the wall was too great for thermal equilibrium. Since the reaction of ortho- to para-H2 is exothermic, the catalyst bed center was warmer than the edges. Second, the catalyst bed was too shallow using a 1/4 feet tube. This caused reactant blow-by which was thought to decrease the measured activity when the flow rate was increased. The 1/8 feet tube corrected both of these concerns.

Brooks, Christopher J.↗

A cesium TELEC experiment at Lewis Research Center

The thermoelectronic laser energy converter (TELEC), was studied as a method of converting a 10.6 mm CO2 laser beam into electric power. The calculated characteristics of a TELEC seem to be well matched to the requirements of a spacecraft laser energy conversion system. The TELEC is a high power density plasma device which absorbs an intense laser beam by inverse bremsstrahlung with the plasma electrons. In the TELEC process, electromagnetic radiation is absorbed directly in the plasma electrons producing a high electron temperature. The energetic electrons diffuse out of the plasma striking two electrodes which are in contact with the plasma at the boundaries. These two electrodes have different areas: the larger one is designated as the collector, the smaller one is designated as the emitter. The smaller electrode functions as an electron emitter to provide continuity of the current. Waste heat is rejected from the collector electrode. An experiment was carried out with a high power laser using a cesium vapor TELEC cell with 30 cm active length. Laser supported plasma was produced in the TELEC device during a number of laser runs over a period of several days. Electric power from the TELEC was observed with currents in the range of several amperes and output potentials of less than 1 volt. The magnitudes of these electric outputs were smaller than anticipated but consistent with the power levels of the laser during this experiment.

Britt, E. J.↗