Search NASA⌕ Search

SEARCH · Search NASA

Results for “correlation coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Tracking fuzzy borders using geodesic curves with application to liver segmentation on planning CT

Purpose: This work aims to develop a robust and efficient method to track the fuzzy borders between liver and the abutted organs where automatic liver segmentation usually suffers, and to investigate its applications in automatic liver segmentation on noncontrast-enhanced planning computed tomography (CT) images. Methods: In order to track the fuzzy liver–chestwall and liver–heart borders where oversegmentation is often found, a starting point and an ending point were first identified on the coronal view images; the fuzzy border was then determined as a geodesic curve constructed by minimizing the gradient-weighted path length between these two points near the fuzzy border. The minimization of path length was numerically solved by fast-marching method. The resultant fuzzy borders were incorporated into the authors’ automatic segmentation scheme, in which the liver was initially estimated by a patient-specific adaptive thresholding and then refined by a geodesic active contour model. By using planning CT images of 15 liver patients treated with stereotactic body radiation therapy, the liver contours extracted by the proposed computerized scheme were compared with those manually delineated by a radiation oncologist. Results: The proposed automatic liver segmentation method yielded an average Dice similarity coefficient of 0.930 ± 0.015, whereas it was 0.912 ± 0.020 if the fuzzy border tracking was not used. The application of fuzzy border tracking was found to significantly improve the segmentation performance. The mean liver volume obtained by the proposed method was 1727 cm{sup 3}, whereas it was 1719 cm{sup 3} for manual-outlined volumes. The computer-generated liver volumes achieved excellent agreement with manual-outlined volumes with correlation coefficient of 0.98. Conclusions: The proposed method was shown to provide accurate segmentation for liver in the planning CT images where contrast agent is not applied. The authors’ results also clearly demonstrated that the application of tracking the fuzzy borders could significantly reduce contour leakage during active contour evolution.

60 APPLIED LIFE SCIENCES↗

TU-G-BRA-06: PET-Based Treatment Response Assessement for Neoadjuvent Chemoradiation for Pancreatic Adenocarcinoma

Purpose: To address the limitations of the conventional response evaluation criteria in solid tumors (RECIST), and validate PET response criteria in solid tumors (PERCIST1.0). We analyze the relationship between the pathological treatment response (PTR) and PERCIST1.0 for patients treated with neoadjuvent chemoradiation (nCR) for pancreatic adenocarcinoma. Methods: The pre- and post-nCR CT and PET data for a total of 8 patients with resectable, or borderline resectable pancreatic head adenocarcinoma treated with nCR were retrospectively analyzed. These data were compared with the PTR which were graded according to tumor cell destruction (cellularity), with Grade1, 2 or 3 (G1, G2 or G3) for good, moderate, and poor responses, respectively. RECIST-based PET (RECISTPET), and PERCIST1.0 were defined using lean body mass normalized SUV (nSUVlb). RECIST-based CT (RECISTCT) was defined by contouring the whole pancreas head (CTPH). Pre- and post-nSUVlb and SUVbw, PERCIST 1.0, were correlated with PTR using Pearson’s correlation coefficient test. Results: The average mean and SD in nSUVlb for all 8 patients analyzed were lower in post-nCR (1.35±0.34) compared to those at pre-nCR (1.38±0.20). Using PERCIST1.0, 5/8 patients showed stable metabolic disease (SMD), 2/8 partial metabolic response (PMR), and 1/8 progressive metabolic disease (PMD). Using RECISTPET 4/8 showed stable disease (STD), 4/8 partial response (PR), whereas 8/8 showed stable disease (STD) using RECISTCT. PTR were correlated with PERCIST1.0 (R=0.3780/P=0.6071). Pathological tumor size was correlated with RECISTCT (R=0.0727/P=0.8679), and RECISTPET, R=−0.3333/P=0.3798. Conclusion: Chemoradiation treatment response assessment based on metabolic tumor activities using PRECIST1.0 and RECISTPET appears to provide better agreement with pathological assessment as compared to the conventional CT-based assessment using RECISTCT. The integration of these additional radiographic metrics in assessing treatment response to nCR for pancreatic adenocarcinoma may provide a promising strategy to better select those patients most suitable for therapeutic intensification.

60 APPLIED LIFE SCIENCES↗

Comparison of Solar UVA and UVB Radiation Measured in Selangor, Malaysia

The solar ultraviolet A (UVA) radiation data was measured at Physics Building, Universiti Kebangsaan Malaysia (2 degree sign 55' N, 101 degree sign 46' E, 50m asl) by the Xplorer GLX Pasco that connected to UVA Light sensor. The measured solar UVA data were compared with the total daily solar ultraviolet B (UVB) radiation data recorded by the Malaysian Metrological Department at Petaling Jaya, Malaysia (3 degree sign 06' N, 101 degree sign 39' E, 50m asl) for 18 days in year 2007. The daily total average of UVA radiation received is (298{+-}105) kJm{sup -2} while the total daily maximum is (600{+-}56) kJm{sup -2}. From the analysis, it shows that the values of UVA radiation data were higher than UVB radiation data with the average ratio of 6.41% between 3-14%. A weak positive correlation was found (the correlation coefficient, r, is 0.22). The amount of UVA radiation that reached the earth surface is less dependence on UVB radiation and the factors were discussed.

54 ENVIRONMENTAL SCIENCES↗

Exploring the Margin Recipe for Online Adaptive Radiation Therapy for Intermediate-Risk Prostate Cancer: An Intrafractional Seminal Vesicles Motion Analysis

Purpose: To provide a benchmark for seminal vesicle (SV) margin selection to account for intrafractional motion and to investigate the effectiveness of 2 motion surrogates in predicting intrafractional SV coverage. Methods and Materials: Fifteen prostate patients were studied. Each patient had 5 pairs (1 patient had 4 pairs) of pretreatment and posttreatment cone beam CTs (CBCTs). Each pair of CBCTs was registered on the basis of prostate fiducial markers. All pretreatment SVs were expanded with 1-, 2-, 3-, 4-, 5-, and 8-mm isotropic margins to form a series of planning target volumes, and their intrafractional coverage to the posttreatment SV determined the “ground truth” for exact coverage. Two motion surrogates, the center of mass (COM) and the border of contour, were evaluated by the use of Pearson product-moment correlation coefficient and exponential fitting for predicting SV underdosage. Action threshold of each surrogate was calculated. The margin for each surrogate was calculated according to a traditional margin recipe. Results: Ninety-five percent posttreatment SV coverage was achieved in 9%, 53%, 73%, 86%, 95%, and 97% of fractions with 1-, 2-, 3-, 4-, 5-, and 8-mm margins, respectively. The 5-mm margins provided 95% intrafractional SV coverage in over 90% of fractions. The correlation between the COM and border was weak, moderate, and strong in the left-right (L-R), anterior-posterior (A-P), and superior-inferior (S-I) directions, respectively. Exponential fitting gave the underdosage threshold of 4.5 and 7.0 mm for the COM and border. The Van Herk margin recipe recommended 0-, 0.5-, and 0.8-mm margins in the L-R, A-P, and S-I directions based on the COM, and 1.2-, 3.9-, and 2.5-mm margins based on the border. Conclusions: Five-millimeter isotropic margins for the SV constitute the minimum required to mitigate the intrafractional motion. Both the COM and the border are acceptable predictors for SV underdosage with 4.5- and 7.0-mm action threshold. Traditional margin based on the COM or border underestimates the margin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-174: Evaluation of the Optimal Intensity Modulated Radiation Therapy Plans Done On the Maximum and Average Intensity Projection CTs

Purpose: To determine the difference in coverage between plans done on average intensity projection and maximum intensity projection CT data sets for lung patients and to establish correlations between different factors influencing the coverage. Methods: For six lung cancer patients, 10 phases of equal duration through the respiratory cycle, the maximum and average intensity projections (MIP and AIP) from their 4DCT datasets were obtained. MIP and AIP datasets had three GTVs delineated (GTVaip — delineated on AIP, GTVmip — delineated on MIP and GTVfus — delineated on each of the 10 phases and summed up). From the each GTV, planning target volumes (PTV) were then created by adding additional margins. For each of the PTVs an IMRT plan was developed on the AIP dataset. The plans were then copied to the MIP data set and were recalculated. Results: The effective depths in AIP cases were significantly smaller than in MIP (p < 0.001). The Pearson correlation coefficient of r = 0.839 indicates strong degree of positive linear relationship between the average percentage difference in effective depths and average PTV coverage on the MIP data set. The V2 0 Gy of involved lung depends on the PTV coverage. The relationship between PTVaip mean CT number difference and PTVaip coverage on MIP data set gives r = 0.830. When the plans are produced on MIP and copied to AIP, r equals −0.756. Conclusion: The correlation between the AIP and MIP data sets indicates that the selection of the data set for developing the treatment plan affects the final outcome (cases with high average percentage difference in effective depths between AIP and MIP should be calculated on AIP). The percentage of the lung volume receiving higher dose depends on how well PTV is covered, regardless of on which set plan is done.

60 APPLIED LIFE SCIENCES↗

Visibility and artifacts of gold fiducial markers used for image guided radiation therapy of pancreatic cancer on MRI

Purpose: In radiation therapy of pancreatic cancer, tumor alignment prior to each treatment fraction is improved when intratumoral gold fiducial markers (from here onwards: markers), which are visible on computed tomography (CT) and cone beam CT, are used. Visibility of these markers on magnetic resonance imaging (MRI) might improve image registration between CT and magnetic resonance (MR) images for tumor delineation purposes. However, concomitant image artifacts induced by markers are undesirable. The extent of visibility and artifact size depend on MRI-sequence parameters. The authors’ goal was to determine for various markers their potential to be visible and to generate artifacts, using measures that are independent of the MRI-sequence parameters. Methods: The authors selected ten different markers suitable for endoscopic placement in the pancreas and placed them into a phantom. The markers varied in diameter (0.28–0.6 mm), shape, and iron content (0%–0.5%). For each marker, the authors calculated T{sub 2}{sup ∗}-maps and ΔB{sub 0}-maps using MRI measurements. A decrease in relaxation time T{sub 2}{sup ∗} can cause signal voids, associated with visibility, while a change in the magnetic field B{sub 0} can cause signal shifts, which are associated with artifacts. These shifts inhibit accurate tumor delineation. As a measure for potential visibility, the authors used the volume of low T{sub 2}{sup ∗}, i.e., the volume for which T{sub 2}{sup ∗} differed from the background by >15 ms. As a measure for potential artifacts, the authors used the volume for which |ΔB{sub 0}| > 9.4 × 10{sup −8} T (4 Hz). To test whether there is a correlation between visibility and artifact size, the authors calculated the Spearman’s correlation coefficient (R{sub s}) between the volume of low T{sub 2}{sup ∗} and the volume of high |ΔB{sub 0}|. The authors compared the maps with images obtained using a clinical MR-sequence. Finally, for the best visible marker as well as the marker that showed the smallest artifact, the authors compared the phantom data with in vivo MR-images in four pancreatic cancer patients. Results: The authors found a strong correlation (R{sub s} = 1.00, p < 0.01) between the volume of low T{sub 2}{sup ∗} and the volume with high |ΔB{sub 0}|. Visibility in clinical MR-images increased with lower T{sub 2}{sup ∗}. Signal shift artifacts became worse for markers with high |ΔB{sub 0}|. The marker that was best visible in the phantom, a folded marker with 0.5% iron content, was also visible in vivo, but showed artifacts on diffusion weighted images. The marker with the smallest artifact in the phantom, a small, stretched, ironless marker, was indiscernible on in vivo MR-images. Conclusions: Changes in T{sub 2}{sup ∗} and ΔB{sub 0} are sequence-independent measures for potential visibility and artifact size, respectively. Improved visibility of markers correlates strongly to signal shift artifacts; therefore, marker choice will depend on the clinical purpose. When visibility of the markers is most important, markers that contain iron are optimal, preferably in a folded configuration. For artifact sensitive imaging, small ironless markers are best, preferably in a stretched configuration.

60 APPLIED LIFE SCIENCES↗

Reliability of Quantitative Ultrasonic Assessment of Normal-Tissue Toxicity in Breast Cancer Radiotherapy

Purpose: We have recently reported that ultrasound imaging, together with ultrasound tissue characterization (UTC), can provide quantitative assessment of radiation-induced normal-tissue toxicity. This study's purpose is to evaluate the reliability of our quantitative ultrasound technology in assessing acute and late normal-tissue toxicity in breast cancer radiotherapy. Method and Materials: Our ultrasound technique analyzes radiofrequency echo signals and provides quantitative measures of dermal, hypodermal, and glandular tissue toxicities. To facilitate easy clinical implementation, we further refined this technique by developing a semiautomatic ultrasound-based toxicity assessment tool (UBTAT). Seventy-two ultrasound studies of 26 patients (720 images) were analyzed. Images of 8 patients were evaluated for acute toxicity (<6 months postradiotherapy) and those of 18 patients were evaluated for late toxicity ({>=}6 months postradiotherapy). All patients were treated according to a standard radiotherapy protocol. To assess intraobserver reliability, one observer analyzed 720 images in UBTAT and then repeated the analysis 3 months later. To assess interobserver reliability, three observers (two radiation oncologists and one ultrasound expert) each analyzed 720 images in UBTAT. An intraclass correlation coefficient (ICC) was used to evaluate intra- and interobserver reliability. Ultrasound assessment and clinical evaluation were also compared. Results: Intraobserver ICC was 0.89 for dermal toxicity, 0.74 for hypodermal toxicity, and 0.96 for glandular tissue toxicity. Interobserver ICC was 0.78 for dermal toxicity, 0.74 for hypodermal toxicity, and 0.94 for glandular tissue toxicity. Statistical analysis found significant changes in dermal (p < 0.0001), hypodermal (p = 0.0027), and glandular tissue (p < 0.0001) assessments in the acute toxicity group. Ultrasound measurements correlated with clinical Radiation Therapy Oncology Group (RTOG) toxicity scores of patients in the late toxicity group. Patients with RTOG Grade 1 or 2 had greater ultrasound-assessed toxicity percentage changes than patients with RTOG Grade 0. Conclusion: Early and late radiation-induced effects on normal tissue can be reliably assessed using quantitative ultrasound.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Molecular Simulations of CO 2 and H 2 Solubility, CO 2 Diffusivity, and Solvent Viscosity at 298 K for 27 Commercially Available Physical Solvents

CO 2 and H 2 solubilities, CO 2 /H 2 solubility selectivities, CO 2 diffusivities, and solvent viscosities in 27 commercially available physical solvents at 298 K were calculated from molecular simulations using the CHARMM36 all-atom force field for most solvents, and the simulation results were compared with available experimental data in this report. The van der Waals radius parameters for solvents were slightly tuned to reproduce the experimental solvent density. The simulated CO 2 solubilities are comparable with the experimental data, with an average absolute difference of 28%. For the homologous compounds containing the –(OCH 2 CH 2 )– repeat unit, both simulated and experimental data show that CO 2 solubility decreases when the number of repeat units is increased; CO 2 solubilities in these homologous compounds exhibit almost a perfect positive linear correlation with the solvent free-volume fractions. The simulated H 2 solubilities and CO 2 /H 2 solubility selectivities are also comparable with the experimental data, with differences of 22% and 17%, respectively. The H 2 solubilities in all solvents researched here correlate very well with the solvent free-volume fractions, exhibiting a positive linear correlation coefficient of 0.84. Additionally, simulations show that CO 2 solubility decreases when the temperature is increased. In contrast, H 2 solubility increases at elevated temperature, which is partly due to the increased solvent free-volume fraction at elevated temperature. Lastly, although the viscosity difference tends to be large (30%–246%) between simulation and experiment, both simulated and experimental data exhibit a similar solvent viscosity trend. Furthermore, simulations show that CO 2 diffusivities in solvents are very strongly correlated with the solvent viscosities and the relationship between them is given by D$_{CO_{2}}$ = (2.6 ± 0.3) × 10 –9 /η solvent 0.59 ± 0.03.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Two Distinct Types of CME-flare Relationships Based on SOHO and STEREO Observations

In this paper, we present two distinct types of coronal mass ejection (CME)-flare relationships according to their observing time differences using 107 events from 2010 to 2013. The observing time difference, Δ T , is defined as flare peak time minus CME first appearance time at Solar Terrestrial Relations Observatory ( STEREO ) COR1 field of view. There are 41 events for group A (Δ T < 0) and 66 events for group B (Δ T ≥ 0). We compare CME 3D parameters (speed and kinetic energy) based on multi-spacecraft data ( SOlar and Heliospheric Observatory ( SOHO ) and STEREO A and B ) and their associated flare properties (peak flux, fluence, and duration). Our main results are as follows. First, there are better relationships between CME and flare parameters for group B than that of group A. In particular, CME 3D kinetic energy for group B is well correlated with flare fluence with the correlation coefficient of 0.67, which is much stronger than that (cc = 0.31) of group A. Second, the events belonging to group A have short flare durations of less than 1 hr (mean = 21 minutes), while the events for group B have longer durations up to 4 hr (mean = 81 minutes). Third, the mean value of height at peak speed for group B is 4.05 Rs, which is noticeably higher than that of group A (1.89 Rs). This is well correlated with the CME acceleration duration (cc = 0.75). A higher height at peak speed and a longer acceleration duration of CME for group B could be explained by the fact that magnetic reconnections for group B continuously occur for a longer time than those for group A.

79 ASTRONOMY AND ASTROPHYSICS↗

Polarization effects in elastic proton-electron scattering

The experimental observables for the elastic reaction induced by protons scattering from electrons are calculated in the Born approximation. The differential cross section and polarization observables have been derived assuming one-photon exchange. Numerical estimates are given for spin correlation coefficients, polarization transfer coefficients, and depolarization coefficients in a wide kinematical range. Specific attention is given to the kinematical conditions; that is, to the specific range of incident energy and transferred momentum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

An Empirical Assessment of the MODIS Land Cover Dynamics and TIMESAT Land Surface Phenology Algorithms

Observations of vegetation phenology at regional-to-global scales provide important information regarding seasonal variation in the fluxes of energy, carbon, and water between the biosphere and the atmosphere. Numerous algorithms have been developed to estimate phenological transition dates using time series of remotely sensed spectral vegetation indices. A key challenge, however, is that different algorithms provide inconsistent results. This study provides a comprehensive comparison of start of season (SOS) and end of season (EOS) phenological transition dates estimated from 500 m MODIS data based on two widely used sources of such data: the TIMESAT program and the MODIS Global Land Cover Dynamics (MLCD) product. Specifically, we evaluate the impact of land cover class, criteria used to identify SOS and EOS, and fitting algorithm (local versus global) on the transition dates estimated from time series of MODIS enhanced vegetation index (EVI). Satellite-derived transition dates from each source are compared against each other and against SOS and EOS dates estimated from PhenoCams distributed across the Northeastern United States and Canada. Our results show that TIMESAT and MLCD SOS transition dates are generally highly correlated (r = 0.51-0.97), except in Central Canada where correlation coefficients are as low as 0.25. Relative to SOS, EOS comparison shows lower agreement and higher magnitude of deviations. SOS and EOS dates are impacted by noise arising from snow and cloud contamination, and there is low agreement among results from TIMESAT, the MLCD product, and PhenoCams in vegetation types with low seasonal EVI amplitude or with irregular EVI time series. In deciduous forests, SOS dates from the MLCD product and TIMESAT agree closely with SOS dates from PhenoCams, with correlations as high as 0.76. Overall, our results suggest that TIMESAT is well-suited for local-to-regional scale studies because of its ability to tune algorithm parameters, which makes it more flexible than the MLCD product. At large spatial scales, where local tuning is not feasible, the MLCD product provides a readily available data set based on a globally consistent approach that provides SOS and EOS dates that are comparable to results from TIMESAT.

47 OTHER INSTRUMENTATION↗

Probing nuclear quadrupole deformation from correlation of elliptic flow and transverse momentum in heavy ion collisions

In heavy ion collisions, elliptic flow v2 and radial flow, characterized by eventwise average transverse momentum [p T ], are related to the shape and size of the overlap region, which are sensitive to the shape of colliding atomic nuclei. The Pearson correlation coefficient between v 2 and [p T ], ρ 2 , was found to be particularly sensitive to the quadrupole deformation parameter β that is traditionally measured in low energy experiments. Built on earlier insight that the prolate deformation β>0 reduces the ρ 2 in ultracentral collisions (UCC), we show that the prolate deformation β<0 enhances the value of ρ 2 . As β>0 and β<0 are the two extremes of triaxiality, the strength and sign of v 2 2 -[pT] correlation can be used to provide valuable information on the triaxiality of the nucleus. Our study provide further arguments for using the hydrodynamic flow as a precision tool to directly image the deformation of the atomic nuclei at extremely short timescale (<10 -24 s).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Study of nonlinear oscillations in a glow discharge plasma using empirical mode decomposition and Hilbert Huang transform

Hilbert Huang transform (HHT) based time series analysis was carried out on nonlinear floating potential fluctuations obtained from hollow cathode glow discharge plasma in the presence of anode glow. HHT was used to obtain contour plots and the presence of nonlinearity was studied. Frequency shift with time, which is a typical nonlinear behaviour, was detected from the contour plots. Various plasma parameters were measured and the concepts of correlation coefficients and the physical contribution of each intrinsic mode function have been discussed. Physically important quantities such as instantaneous energy and their uses in studying physical phenomena such as intermittency and non-stationary data have also been discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detailed Characterization of the Early Response of Head-Neck Cancer Xenografts to Irradiation Using {sup 18}F-FDG-PET Imaging

Purpose: To investigate the metabolic information provided by {sup 18}F-fluorodeoxyglucose-positron emission tomography (FDG-PET) during the early response of head-and-neck squamous cell carcinoma (HNSCC) xenografts to radiotherapy (RT). Methods and Materials: Low-passage HNSCC cells (UT14) were injected into the rear flanks of female nu/nu mice to generate xenografts. After tumors grew to 400-500 mm{sup 3}, they were treated with either 15 Gy in one fraction (n = 18) or sham RT (n = 12). At various time points after treatment, tumors were assessed with 2-h dynamic FDG-PET and immediately harvested for direct histological correlation. Different analytical parameters were used to process the dynamic PET data: kinetic index (Ki), standard uptake value (SUV), sensitivity factor (SF), and retention index (RI). Tumor growth was assessed using the specific growth rate (SGR) and correlated with PET parameters using the Pearson correlation coefficient (r). Receiver operating characteristic (ROC) and the area under the ROC curve (AUC) were used to test PET parameters for their ability to predict for radiation necrosis and radiation change. Results: Tumor growth was arrested for the first 20 days after RT and recovered thereafter. Histologically, radiation change was observed in the peripheral regions of tumors between days 7 and 23 after RT, and radiation necrosis were observed in the central regions of tumors between days 7 and 40. Ki provided the best correlation with SGR (r = 0.51) and was the optimal parameter to predict for early radiation necrosis (AUC = 0.804, p = 0.07). SUV{sub 30min} was the strongest predictor for late radiation necrosis (AUC = 0.959, p = 0.004). Both RI{sub 30-60min} and SF{sub 12-70min} were very accurate in predicting for radiation change (AUC = 0.891 and 0.875, p = 0.009 and 0.01, respectively). Conclusions: Dynamic FDG-PET analysis (such as Ki or SF) may provide informative assessment of early radiation necrosis or radiation change of HNSCC xenografts after RT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3D Deep Learning Joint Inversion of Active Seismic Full Waveform and Passive Seismic Traveltime Data for Reservoir Imaging and Uncertainty Quantification

Here, we present deep learning (DL) networks for three-dimensional (3D) joint inversion of active seismic full waveform and passive seismic traveltime data to image reservoirs and their properties and quantify imaging uncertainties. Active seismic full-waveform data can provide high-resolution monitoring images but are collected only intermittently because of their high acquisition cost. In contrast, passive seismic data can be gathered at relatively low cost between regular active surveys, although their imaging quality can be compromised by factors such as low signal-to-noise ratios and limited ray coverage of the target. Although these datasets are routinely acquired together at CO 2 storage sites, their combined inversion within a 3D DL framework has not been previously demonstrated. To our knowledge, this is the first study to address this gap, combining the strength of both data types. For efficient data storage and DL training with large 3D seismic datasets, we use a 3D data matrix in which a random number of passive seismic traveltime data are stored as parabolic envelopes using one-hot encoding and a 3D full-waveform data matrix in which multiple shot gathers are summed. Two network architectures are evaluated: a single-encoder U-Net for single-data type inversion and a dual-encoder U-Net for joint inversion of active and passive seismic data. We also evaluate the single-encoder U-Net for joint inversion by concatenating full-waveform data and traveltime data. We propose a systematic approach for selecting an optimal dropout rate that balances regularization during training and Monte Carlo dropout-based uncertainty quantification during prediction by examining the correlation coefficient between standard deviation and prediction error, along with the training misfit, across a range of dropout rates. 3D DL inversion experiments include five different network configurations, with evaluations under ideal, noisy and dropout-enabled conditions. Both model and data uncertainties are assessed, as well as their combined effects. Across all conditions, the networks consistently predict accurate CO 2 saturation models with low prediction errors, such as a structural similarity index of 0.993 and CO 2 difference of 1.1%. Uncertainty estimates show strong spatial correlation with prediction errors, confirming the effectiveness of the proposed dropout selection approach. The results demonstrate that our DL approach, utilizing compact data representations and appropriate uncertainty quantification, yields accurate subsurface images under various inversion conditions and provides valuable insights into the reliability of predictions.

Um, Evan Schankee [Lawrence Berkeley National Labo↗

Human alteration of the rural landscape: Variations in visual perception

The objective of this investigation is to evaluate how visual perception varies as the rural landscape is altered by human interventions of varying character. An experiment is carried out using Semantic Differential Analysis to analyse the effect of the character and the type of the intervention on perception. Interventions are divided into elements of 'permanent industrial character', 'elements of permanent rural character' and 'elements of temporary character', and these categories are sub-divided into smaller groups according to the type of development. To increase the reliability of the results, the Intraclass Correlation Coefficient tool, is applied to validate the semantic space of the perceptual responses and to determine the number of subjects required for a reliable evaluation of the scenes.

99 GENERAL AND MISCELLANEOUS↗

Study of Azimuthal Correlations in the Target Fragmentation Region in p, d, He, C+C, Ta and C+Ne, Cu Collisions at a Momentum of 4.2, 4.5 and 10 AGeV/c

Azimuthal correlations between the same type of particles (protons or pions) in the target fragmentation region was studied in d, He, C + C, Ta (4.2 AGeV/c), C + Ne, Cu (4.5AGeV/c) and p + C, Ta (10 GeV/c) interactions. The data were obtained from the SKM-200-GIBS streamer chamber and from Propane Bubble Chamber (PBL-500) systems utilized at JINR. Study of multiparticle azimuthal correlations offers unique information about space-time evolution of the interactions. Azimuthal correlations were investigated by using correlation function C($\Delta\phi$)=dN/d($\Delta\phi$), where $\Delta\phi$ represents the angle between the sums of transverse momenta vectors for particles emitted in the forward and backward hemispheres. For protons a "back-to back" ("negative") azimuthal correlations were observed in the above mentioned interactions. The absolute values of the correlation coefficient $|\xi|$ -- the slope parameter of C($\Delta\phi$), strongly depend on the mass number of the target ($A_T$) nuclei in the nucleon-nucleus and nucleus-nucleus collisions. Namely, $|\xi|$ -- decreases with increase of $A_T$ in p+C and p+Ta collisions, while $|\xi|$ decreases from d+C up to C+Ne and then almost does not change with increase of $A_P$, $A_T$ in (d+He)Ta, C+Cu and C+Ta collisions. For pions a "back-to-back" correlations were obtained for a light targets (C, Ne), and a "side-by-side" ("positive") correlations for a heavy targets (Cu, Ta). The $|\xi|$ insignificantly changes with increase of the momenta per nucleon and almost does not change with increase of $A_P$ and $A_T$. Models, used for description of the data -- the Ultra relativistic Quantum Molecular Dynamic (UrQMD) and Quark-Gluon String Model (QGSM), satisfactorily describe the obtained experimental results.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Quantitative Real-Time Fluoroscopy Analysis on Measurement of the Hepatic Arterial Flow During Transcatheter Arterial Chemoembolization of Hepatocellular Carcinoma: Comparison with Quantitative Digital Subtraction Angiography Analysis

PurposeTo quantify the arterial flow change during transcatheter arterial chemoembolization (TACE) for hepatocellular carcinoma (HCC) using digital subtraction angiography, quantitative color-coding analysis (d-QCA), and real-time subtraction fluoroscopy QCA (f-QCA).Materials and MethodsThis prospective study enrolled 20 consecutive patients with HCC who had undergone TACE via a subsegmental approach between February 2014 and April 2015. The TACE endpoint was a sluggish antegrade tumor-feeding arterial flow. d-QCA and f-QCA were used for determining the relative maximal density time (rT{sub max}) of the selected arteries. The rT{sub max} of the selected arteries was analyzed in d-QCA and f-QCA before and after TACE, and its correlation in both analyses was evaluated.ResultsThe pre- and post-TACE rT{sub max} of the embolized segmental artery in d-QCA and f-QCA were 1.59 ± 0.81 and 2.97 ± 1.80 s (P < 0.001) and 1.44 ± 0.52 and 2.28 ± 1.02 s (P < 0.01), respectively. The rT{sub max} of the proximal hepatic artery did not significantly change during TACE in d-QCA and f-QCA. The Spearman correlation coefficients of the pre- and post-TACE rT{sub max} of the embolized segmental artery between d-QCA and f-QCA were 0.46 (P < 0.05) and 0.80 (P < 0.001). Radiation doses in one series of d-QCA and f-QCA were 140.7 ± 51.5 milligray (mGy) and 2.5 ± 0.7 mGy, respectively.Conclusionsf-QCA can quantify arterial flow changes with a higher temporal resolution and lower radiation dose. Flow quantification of the embolized segmental artery using f-QCA and d-QCA is highly correlated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗