Search NASA⌕ Search

SEARCH · Search NASA

Results for “defect imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

TH-CD-202-09: Free-Breathing Proton MRI Functional Lung Avoidance Maps to Guide Radiation Therapy

Purpose: Pulmonary functional MRI using inhaled gas contrast agents was previously investigated as a way to identify well-functioning lung in patients with NSCLC who are clinical candidates for radiotherapy. Hyperpolarized noble-gas ({sup 3}He and {sup 129}Xe) MRI has also been optimized to measure functional lung information, but for a number of reasons, the clinical translation of this approach to guide radiotherapy planning has been limited. As an alternative, free-breathing pulmonary 1H MRI using clinically available MRI systems and pulse sequences provides a non-contrast-enhanced method to generate both ventilation and perfusion maps. Free-breathing {sup 1}H MRI exploits non-rigid registration and Fourier decomposition of MRI signal intensity differences (Bauman et al., MRM, 2009) that may be generated during normal tidal breathing. Here, our objective was to generate free-breathing {sup 1}H MRI ventilation and lung function avoidance maps in patients with NSCLC as a way to guide radiation therapy planning. Methods: Stage IIIA/IIIB NSCLC patients (n=8, 68±9yr) provided written informed consent to a randomized controlled clinical trial ( https://clinicaltrials.gov/ct2/show/NCT02002052 ) that aimed to compare outcomes related to image-guided versus conventional radiation therapy planning. Hyperpolarized {sup 3}He/{sup 129}Xe and dynamic free tidal-breathing {sup 1}H MRI were acquired as previously described (Capaldi et al., Acad Radiol, 2015). Non-rigid registration was performed using the modality-independent-neighbourhood-descriptor (MIND) deformable approach (Heinrich et al., Med Image Anal, 2012). Ventilation-defect-percent ({sup 3}He:VDP{sub He}, {sup 129}Xe:VDP{sub Xe}, Free-breathing-{sup 1}H:VDP{sub FB}) and the corresponding ventilation maps were compared using Pearson correlation coefficients (r) and the Dice similarity coefficient (DSC). Results: VDP{sub FB} was significantly related to VDP{sub He} (r=.71; p=.04) and VDP{sub Xe} (r=.80; p=.01) and there were also strong spatial relationships (DSC{sub He}/DSC{sub Xe}=89±3%/77±11%). Conclusion: In this proof of concept study in NSCLC patients, free-breathing {sup 1}H MRI ventilation defects were quantitatively and spatially related to inhaled-noble-gas MRI ventilation defects. Free-breathing {sup 1}H MRI measures lung function/ventilation that can be used to optimize radiotherapy planning in NSCLC patients.

60 APPLIED LIFE SCIENCES↗

Design of a reading test for low vision image warping

NASA and the University of Houston College of Optometry are examining the efficacy of image warping as a possible prosthesis for at least two forms of low vision - maculopathy and retinitis pigmentosa. Before incurring the expense of reducing the concept to practice, one would wish to have confidence that a worthwhile improvement in visual function would result. NASA's Programmable Remapper (PR) can warp an input image onto arbitrary geometric coordinate systems at full video rate, and it has recently been upgraded to accept computer-generated video text. We have integrated the Remapper with an SRI eye tracker to simulate visual malfunction in normal observers. A reading performance test has been developed to determine if the proposed warpings yield an increase in visual function; i.e., reading speed. We will describe the preliminary experimental results of this reading test with a simulated central field defect with and without remapped images.

Loshin, David S.↗

Hollow Ptychography: Toward Simultaneous 4D Scanning Transmission Electron Microscopy and Electron Energy Loss Spectroscopy

With the recent development of high-acquisition-speed pixelated detectors, 4D scanning transmission electron microscopy (4D-STEM) is becoming routinely available in high-resolution electron microscopy. 4D-STEM acts as a “universal” method that provides local information on materials that is challenging to extract from bulk techniques. It extends conventional STEM imaging to include super-resolution techniques and to provide quantitative phase-based information, such as differential phase contrast, ptychography, or Bloch wave phase retrieval. However, an important missing factor is the chemical and bonding information provided by electron energy loss spectroscopy (EELS). 4D-STEM and EELS cannot currently be acquired simultaneously due to the overlapping geometry of the detectors. Here, the feasibility of modifying the detector geometry to overcome this challenge for bulk specimens is demonstrated, and the use of a partial or defective detector for ptycholgaphic structural imaging is explored. Here, results show that structural information beyond the diffraction-limit and chemical information from the material can be extracted together, resulting in simultaneous multi-modal measurements, adding the additional dimensions of spectral information to 4D datasets.

4D-scanning transmitting electron microscopy (STEM↗

Atomic-scale imaging and charge state manipulation of NV centers by scanning tunneling microscopy

Nitrogen-vacancy (NV) centers in diamond are among the most promising solid-state qubit candidates, owing to their exceptionally long spin coherence times, efficient spin-photon coupling, room-temperature operation, and steadily advancing fabrication and integration techniques. Despite significant progress in the field, atomic-scale characterization and control of individual NV centers have remained elusive. In this work, we utilize a conductive graphene capping layer to enable direct imaging and manipulation of NV - defects via scanning tunneling microscopy (STM). By investigating over 40 individual NV - centers, we identify their spectroscopic signatures and spatial configurations. Our dI/dV conductance spectra reveal the ground state resonance approximately 300 meV below the Fermi level and density-of-states maps uncover a two-lobed wavefunction aligned along the [111] crystallographic direction. Remarkably, we demonstrate the ability to manipulate the charge state of the NV centers from NV - to NV 0 through STM tip-induced gating. This work represents a significant advance in the atomic-scale imaging, spectroscopic characterization, and charge-state manipulation of NV centers, potentially paving the way for future quantum device development.

Raghavan, Arjun [Univ. of Illinois at Urbana-Champ↗

Effect of threshold parameters on infrared segmentation methods for porosity detection in electron beam powder bed fusion

In-situ process monitoring has seen significant interest in additive manufacturing to address qualification and certification goals. This is especially prevalent in metal powder bed fusion processes such as electron beam powder bed fusion (PBF-EB), with layer-wise infrared imaging being commonly used to detect defects. Here, this work compares two different segmentation methods (static thresholding and statistical thresholding) used for detecting porosity from in-situ infrared imaging data for PBF-EB. Samples were manufactured at a variety of focus offset values to induce porosity. Then, the segmented infrared images were compared to ex-situ X-ray computed tomography scans, which served as a ground-truth reference for objective evaluation. Through this analysis framework, the influential parameters, static threshold and N-value (number of standard deviations above the mean pixel value), respectively, for both image segmentation methods were analyzed and compared for their effects on porosity detection. With optimal parameter settings, the two methods had similar porosity detection performance, but the statistical method performed better under a larger variety of parameter settings.

Infrared imaging↗

Solubility and partitioning of Ar in anorthite, diopside, forsterite, spinel, and synthetic basaltic liquids

The solubility and partitioning of Ar in natural anorthite, diopside, forsterite, spinel, and synthetic iron-free basaltic melts was investigated using a new technique that obviates the postquenching phase separation. It was found that the solubility of Ar in the minerals was surprisingly high. Moreover, the solubility of Ar in different samples of a particular mineral run in the same experiment varied more than the solubility in the same sample run in different experiments, suggesting that noble gases are held in lattice vacancy defects. Moreover, the results of TEM imaging revealed no anomalous microstructures, while EXAFS studies of some samples showed that Kr has no preferred site in the lattices, supporting the defect siting conclusion.

Broadhurst, C. Leigh↗

Folding and stacking defects of graphene flakes probed by electron nanobeam

Combining nanoscale imaging with local electron spectroscopy and diffraction has provided direct information on folding and stacking defects of graphene flakes produced by unrolled multi-walled carbon nanotubes. Structural data obtained by nanoarea electron diffraction complemented with systematic electron energy loss spectroscopy measurements of the surface plasmon losses of single flakes show the presence of flat bilayer regions coexisting with folded areas where the topology of buckled graphene resembles that of warped carbon nanostructures.

36 MATERIALS SCIENCE↗

Correlating activities and defects in (photo)electrocatalysts using in-situ multi-modal microscopic imaging

Photo(electro)catalysts use sunlight to drive chemical reactions such as water splitting. A major factor limiting photocatalyst development is physicochemical heterogeneity which leads to spatially dependent reactivity. To link structure and function in such systems, simultaneous probing of the electrochemical environment at microscopic length scales and a broad range of timescales (ns to s) is required. Here, we address this challenge by developing and applying in- situ (optical) microscopies to map and correlate local electrochemical activity, with hole lifetimes, oxygen vacancy concentrations and photoelectrode crystal structure. Using this multi-modal approach, we study prototypical hematite (α-Fe 2 O 3 ) photoelectrodes. We demonstrate that regions of α-Fe 2 O 3 , adjacent to microstructural cracks have a better photoelectrochemical response and reduced back electron recombination due to an optimal oxygen vacancy concentration, with the film thickness and extended light exposure also influencing local activity. Our work highlights the importance of microscopic mapping to understand activity, in even seemingly homogeneous photoelectrodes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nondestructive microstructural investigation of defects in 4H-SiC epilayers using a multiscale luminescence analysis approach

The development of metal oxide semiconductor field effect transistors (MOSFETs) utilizing epitaxially grown 4H-SiC has accelerated in recent years due to their favorable properties, including a high breakdown field, high saturated electron drift velocity, and good thermal conductivity. However, extended defects in epitaxial 4H-SiC can affect both device yields and operational lifetime. In this work, we demonstrate the importance of a multiscale luminescence characterization approach to studying nondestructively extended defects in epitaxial 4H-SiC semiconducting materials. Multiscale luminescence analysis reveals different aspects of excess charge carrier recombination behavior based on the scale of a particular measurement. Combining measurements of the same extended defect area at different scales tells us more about the essential nature of that defect and its microstructure. Here, we use photoluminescence imaging and cathodoluminescence spectrum imaging to investigate the recombination behavior of several different types of extended defects, including stacking faults, inclusions, and basal plane dislocations. A detailed understanding of the optoelectronic properties of extended defects in epitaxial SiC helps elucidate the microstructure of extended defects and can provide pathways to mitigate detrimental changes during device operation related to their evolution, such as the recombination enhanced dislocation glide effect that affects SiC-based MOSFETs.

3C-inclusion↗

Signal to Noise Studies on Thermographic Data with Fabricated Defects for Defense Structures

There is a growing international interest in thermal inspection systems for asset life assessment and management of defense platforms. The efficacy of flash thermography is generally enhanced by applying image processing algorithms to the observations of raw temperature. Improving the defect signal to noise ratio (SNR) is of primary interest to reduce false calls and allow for easier interpretation of a thermal inspection image. Several factors affecting defect SNR were studied such as data compression and reconstruction using principal component analysis and time window processing.

Zalameda, Joseph N.↗

Method and Apparatus for the Portable Identification of Material Thickness and Defects Using Spatially Controlled Heat Application

A method and a portable apparatus for the nondestructive identification of defects in structures. The apparatus comprises a heat source and a thermal imager that move at a constant speed past a test surface of a structure. The thermal imager is off set at a predetermined distance from the heat source. The heat source induces a constant surface temperature. The imager follows the heat source and produces a video image of the thermal characteristics of the test surface. Material defects produce deviations from the constant surface temperature that move at the inverse of the constant speed. Thermal noise produces deviations that move at random speed. Computer averaging of the digitized thermal image data with respect to the constant speed minimizes noise and improves the signal of valid defects. The motion of thermographic equipment coupled with the high signal to noise ratio render it suitable for portable, on site analysis.

Cramer, K. Elliott↗

Validation of early image acquisitions following Tc-99 m sestamibi injection using a semiconductors camera of cadmium-zinc-telluride

Background: Cadmium-zinc-telluride (CZT) cameras allow to decrease significantly the acquisition time of myocardial perfusion imaging (MPI), but the duration of the examination is still long. Therefore, this study was performed to test the feasibility of early imaging following injection of Tc-99 m sestamibi using a CZT camera. Methods: Seventy patients underwent both an early and a delayed image acquisition after exercise stress test (n = 30), dipyridamole stress test (n = 20), and at rest (n = 20). After injection of Tc-99 m sestamibi, the early image acquisition started on average within 5 minutes for the exercise and rest groups, and 3 minutes 30 seconds for the dipyridamole group. Two independent observers evaluated image quality and extracardiac uptake on four-point scales. The difference between early and later images for each patient was scored on a five-point scale. Results: The image quality and extracardiac uptake of early and delayed image acquisitions were not different for the three groups (P > .05). There was no significant difference between early and delayed image acquisitions in the exercise, dipyridamole, and rest groups, respectively, in 63%, 40%, and 80% of cases. In the exercise group and rest group, a defect was only present in early MPI, respectively, in 13% and 20% of cases. A defect was only present in delayed images in 10% of cases in the exercise group and in 45% of cases in the dipyridamole group. Conclusions: There was no difference between early and later image acquisitions in terms of quality. This protocol reduces the length of the procedure for the patient. Beginning with early image acquisitions may help to overcome the artifacts that are observed at the delayed time.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Super-Resolution Microscopy Reveals Shape and Distribution of Dislocations in Single Crystal Nanocomposites

With their potential to offer new properties, single crystals containing nanoparticles provide an attractive class of nanocomposite materials. Yet, to fully profit from these, it is essential that we can characterise their 3D structures, identifying the locations of individual nanoparticles, and the defects present within the host crystals. With calcite crystals containing quantum dots as a model system, we here use 3D stochastic optical reconstruction microscopy (STORM) to locate the positions of the nanoparticles within the host crystal. The nanoparticles are shown to preferentially associate with dislocations in a manner previously recognised for atomic impurities, rendering these defects visible by STORM. Our images also demonstrate that the types of dislocations formed at the crystal/ substrate interface vary according to the nucleation face, and dislocation loops are observed that have entirely different geometries to classic misfit dislocations. This approach offers a rapid, easily accessed, and non-destructive method for visualising the dislocations present within crystals, and gives insight into the mechanisms by which additives become occluded within crystals.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Creation And Ordering Of Oxygen Vacancies At WO3-d And Perovskite Interfaces

Changes in structure and composition resulting from oxygen deficiency can strongly impact the physical and chemical properties of transition metal oxides. However, it is extremely difficult to accurately characterize the oxygen deficiency levels and pinpoint how these materials properties change in response. In this paper, the effects of substrate strain and oxidizing power on the creation and distribution of oxygen defects in WO3 thin films are investigated in detail. An 18O2 isotope labeled time-of-flight secondary ion mass spectrometry (ToF-SIMS) study reveals that WO3-films grown on STO display a significantly larger oxygen vacancy gradient along the growth direction. This result is corroborated by scanning transmission electron microscopy (STEM) images which reveal a large number of defects present close to the interface to accommodate interfacial strain, leading to ordering of oxygen vacancies and formation of semi-aligned Magnéli phases. The strain is gradually released and tetragonal phase with much better crystallinity is observed at the film/vacuum interface. The changes in structure resulting from oxygen defect creation are shown to have a direct impact on the electronic and optical properties of the films.

Zhang, Kelvin H.↗

Electroluminescence Imaging: A Quantitative Characterization Technique to Measure Dust Occlusion of Solar Cells

Electroluminescence (EL) imaging is a qualitative characterization technique that is typically used to identify cracks, corrosion, and other defects in solar cells. It consists of imaging a cell under forward bias, where the solar cell emits photons due to radiative electron-hole pair recombination. Over the past few years, our team has expanded this into a quantitative technique with the help of image processing. We have primarily used this method to investigate lunar dust occlusion of solar cells and arrays. Lunar dust accumulation on solar cells is a major concern because it directly limits light accessible to the cell, decreasing power output. Many teams are working to develop dust mitigation technology to protect these arrays on the surface of the Moon, but thoroughly characterizing their efficacy is important to ensure their success prior to launch. Here, we present EL as a quantitative characterization technique to observe dust coverage on solar cells that, when coupled with IV performance measurements, can offer unique insights into how dust coverage impacts power output. Quantitative electroluminescence imaging works by running EL images through an image processing script that first grayscales the image then plots a histogram of the brightness of each pixel. On its own, it does not offer much insight into a solar cell’s performance. However, when comparing images to a baseline pristine, undamaged, or uncoated solar cell, it can quickly provide information about the impacts of surface contaminants or damage to the cell. Here, we present a case study where quantitative EL is used to measure the efficacy of dust mitigation technology for flexible solar arrays and discuss the lessons learned about dust mitigation, testing with lunar simulant, and this characterization technique.

photovoltaics↗

Development of CT and 3D-CT Using Flat Panel Detector Based Real-Time Digital Radiography System

The application of Digital Radiography in the Nondestructive Evaluation (NDE) of space vehicle components is a recent development in India. A Real-time DR system based on amorphous silicon Flat Panel Detector has been developed for the NDE of solid rocket motors at Rocket Propellant Plant of VSSC in a few years back. The technique has been successfully established for the nondestructive evaluation of solid rocket motors. The DR images recorded for a few solid rocket specimens are presented in the paper. The Real-time DR system is capable of generating sufficient digital X-ray image data with object rotation for the CT image reconstruction. In this paper the indigenous development of CT imaging based on the Realtime DR system for solid rocket motor is presented. Studies are also carried out to generate 3D-CT image from a set of adjacent CT images of the rocket motor. The capability of revealing the spatial location and characterisation of defect is demonstrated by the CT and 3D-CT images generated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

WE-FG-206-08: Pulmonary Functional Imaging Biomarkers of NSCLC to Guide and Optimize Functional Lung Avoidance Radiotherapy

Purpose: Functional lung avoidance radiotherapy promises optimized therapy planning by minimizing dose to well-functioning lung and maximizing dose to the rest of the lung. Patients with NSCLC commonly present with co-morbid COPD and heterogeneously distributed ventilation abnormalities stemming from emphysema, airways disease, and tumour burden. We hypothesized that pulmonary functional imaging methods may be used to optimize radiotherapy plans to avoid regions of well-functioning lung and significantly improve outcomes like quality-of-life and survival. To ascertain the utility of functional lung avoidance therapy in clinical practice, we measured COPD phenotypes in NSCLC patients enrolled in a randomized-controlled-clinical-trial prior to curative intent therapy. Methods: Thirty stage IIIA/IIIB NSCLC patients provided written informed consent to a randomized-controlled-clinical-trial ( http://clinicaltrials.gov/ct2/show/NCT02002052 ) comparing outcomes in patients randomized to standard or image-guided radiotherapy. Hyperpolarized noble gas MRI ventilation-defect-percent (VDP) (Kirby et al, Acad Radiol, 2012) as well as CT-emphysema measurements were determined. Patients were stratified based on quantitative imaging evidence of ventilation-defects and emphysema into two subgroups: 1) tumour-specific ventilation defects only (TSD), and, 2) tumour-specific and other ventilation defects with and without emphysema (TSD{sub VE}). Receiver-operating-characteristic (ROC) curves were used to characterize the performance of clinical measures as predictors of the presence of non-tumour specific ventilation defects. Results: Twenty-one out of thirty subjects (70%) had non-tumour specific ventilation defects (TSD{sub VE}) and nine subjects had ONLY tumour-specific defects (TSD). Subjects in the TSD{sub VE} group had significantly greater smoking-history (p=.006) and airflow obstruction (FEV{sub 1}/FVC) (p=.001). ROC analysis demonstrated an 87% classification rate for smoking pack-years, 90% for FEV{sub 1}/FVC, and 56% for tumour RECIST measurements for identifying patients with non-tumour and tumour-specific ventilation abnormalities. Conclusion: 70% of NSCLC patients had ventilation abnormalities stemming from emphysema, airways disease and tumour burden. Smoking-history and airflow obstruction, but not RECIST, identified NSCLC patients with ventilation abnormalities appropriate for functional lung avoidance therapy.

60 APPLIED LIFE SCIENCES↗

Toward Quality Control in Perovskite Solar Cell Fabrication: Spot-Like Processing Defects Disrupt Charge Transport Layers and Promote Ag Metal Electrode Intrusion

Metal halide perovskite (MHP) photovoltaics provide high efficiencies with less stringent processing requirements than traditional photovoltaic materials. However, processing related defects must be suppressed as they can lead to decreases in initial device efficiency and potentially compromise long-term device operation. In this work we investigate morphological defects in MHP devices using luminescence imaging followed by in-depth structural and composition analysis using electron microscopy-based methods. We identify several different classes of spot-like processing-related defects and observe that a single device structure may contain multiple types of these defects. The presence of these defects in devices with different layer structures and absorber chemistries makes them relevant to the perovskite photovoltaic community as a whole. The defects are associated with voids in the perovskite layer, inclusions (glass, migrated Ag, dust), thickness variations, hole transport layer disruption with anomalous crystal growth, and electron transport layer disruptions that could allow Ag intrusion and lead to local shunts. As perovskite photovoltaic technology matures, mitigation of such defects is critical to improving not only initial performance but also the long-term stability required for industrial applications.

14 SOLAR ENERGY↗