Search NASA⌕ Search

SEARCH · Search NASA

Results for “design standards”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

CFD Modeling of an 81" Single Slope Barrier Wall Drainage Window for on Grade and Sag Conditions

The main goal of this study is to design a drainage window in an 81" single slope barrier wall for on-grade and sag conditions that could replace the standard ODOT I-3 barrier catch basin. The ODOT design guidelines are as follows: a) Examine configurations of the opening to the flume behind the wall under the wall section to maximize conveyance of flow to a roadside ditch section. b) Examine window lengths and configurations to maximize hydraulic efficiency on a grade up to an absolute maximum window length of 20 ft. c) Use a minimum opening height of 4 in. and consider tapering to an increased height at the outlet to the flume to reduce the potential for debris clogging beneath the barrier section. On-grade locations are analyzed for longitudinal slope up to 5% and spread up to 10 ft. Sag locations, represented by pavement at zero longitudinal slope, are analyzed for water depths up to 18 in. The roadway cross section consists of a 10-ft shoulder at a 4.0% cross slope and pavement at a 1.6% cross slope. All surfaces are represented with Manning’s n = 0.015. Computational fluid dynamics (CFD) is used to perform the analysis. The modeling approach follows previous studies by the authors. The new design is similar to a slotted inlet: a rectangular opening cut into the bottom of a barrier (e.g., a temporary barrier or single slope barrier wall), which typically has a uniform cross section. Findings from laboratory tests of flow under Florida DOT barrier walls were used for additional validation of the modeling approach used in this study.

42 ENGINEERING↗

Deep Underground Neutrino Experiment (DUNE), Far Detector Technical Design Report, Volume II: DUNE Physics

The preponderance of matter over antimatter in the early universe, the dynamics of the supernovae that produced the heavy elements necessary for life, and whether protons eventually decay -- these mysteries at the forefront of particle physics and astrophysics are key to understanding the early evolution of our universe, its current state, and its eventual fate. DUNE is an international world-class experiment dedicated to addressing these questions as it searches for leptonic charge-parity symmetry violation, stands ready to capture supernova neutrino bursts, and seeks to observe nucleon decay as a signature of a grand unified theory underlying the standard model. The DUNE far detector technical design report (TDR) describes the DUNE physics program and the technical designs of the single- and dual-phase DUNE liquid argon TPC far detector modules. Volume II of this TDR, DUNE Physics, describes the array of identified scientific opportunities and key goals. Crucially, we also report our best current understanding of the capability of DUNE to realize these goals, along with the detailed arguments and investigations on which this understanding is based. This TDR volume documents the scientific basis underlying the conception and design of the LBNF/DUNE experimental configurations. As a result, the description of DUNE's experimental capabilities constitutes the bulk of the document. Key linkages between requirements for successful execution of the physics program and primary specifications of the experimental configurations are drawn and summarized. This document also serves a wider purpose as a statement on the scientific potential of DUNE as a central component within a global program of frontier theoretical and experimental particle physics research. Thus, the presentation also aims to serve as a resource for the particle physics community at large.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Standardized nomenclature for photovoltaic connectors

Photovoltaic (PV) systems rely on discrete connectors for the efficient and safe flow of power from module to module and from strings to combiner boxes and inverters. Despite their functional importance, no common nomenclature for PV connectors currently exists, resulting in confusion and miscommunication. Misunderstood terms like "MC4 compatible", "cross-mating", "intermating", "female", and "male" can lead to installation and maintenance errors and compromise system reliability. We believe a standardized terminology will reduce confusion, help support installation best practices, aid in maintenance and repair, inform next-generation designs, and provide a technical basis for improved codes and standards. To that end, we are proposing a standardized glossary for 4 mm PV connectors (the most common type of connector used in PV applications) based on, and validated by, a Sandia National Laboratories' investigation that included the following sources: 1) a comprehensive review of official documents from 20 connector manufacturers, including schematics, datasheets, installation manuals, and catalogs, as well as relevant patents; 2) two rounds of surveys distributed to stakeholders, including connector manufacturers, engineers, asset owners, test labs, and researchers; and 3) visual examination of 25 different models of 4 mm single-pole DC PV connectors to document variations in design and functionality. This work provides a foundation for establishing a clear and consistent terminology for PV connectors that will in turn enable progress toward greater reliability and collaboration across the industry.

14 SOLAR ENERGY↗

IHE DDT Qualification Tests (FY2020-FY2021)

A DDT tube test was designed to meet all requirements established in the new DOE IHE qualification standard. Ten tests were successfully executed with PBX 9502 as a demonstration of the design, assembly, heating system, and methods, and to establish a baseline set of test results with an existing IHE. The explosive response in all tests was low violence (as anticipated). This report contains detailed design drawings, assembly instructions and procedures for future execution of the qualification test series, and makes recommendations for minor improvements.

42 ENGINEERING↗

Evaluation of color in digital nuclear power plant control room displays

Human system interface design in industrial process control is guided by industry standards, human factors best practices, and domain-specific conventions, and often there is a conflict between one or more of the sources of design input for specific design elements. In the nuclear domain, one design element for which conflict arises is the use of color to represent equipment state. Here, this study evaluates the tradeoffs associated with using color in a process control display versus using white and shades of gray. The performance metrics were response time, accuracy, and eye movement metrics using a simplified experimental task and professional operators. Results revealed that adhering to color conventions in nuclear power yielded small advantages in simple tasks, but did not exist for more complex tasks. The results did not provide strong evidence for or against using a particular color scheme and revealed the need for further research on the use of color for commercial nuclear power plants and other process control industries.

99 GENERAL AND MISCELLANEOUS↗

Non-catalytic pyrolysis of associated gas to zero CO 2 hydrogen and high value carbon black

The overall objective of this work is to perform a pre-Front End Engineering Design (pre-FEED) study of the conversion of associated gas produced at an active oil pad of a Bakken oil field producer, to high value carbon black and hydrogen using the Microwave Plasma Pyrolysis of Associated Gas (MPP-AG) process developed by H Quest Vanguard, Inc (HQV). The University of North Dakota’s Center for Process Engineering Research (CPER) collaborated with HQV to complete a design and techno-economic analysis for the MPP-AG deployed at an active Bakken well site flaring an average of 54,000 standard cubic feet per day of AG. The proposed design consists of: • A Microwave Pyrolysis Unit (MPU) which consists of H Quest’s proprietary MPP technology • A patent-pending Gas Conditioning Unit (GCU) designed by the University of North Dakota to condition intermittent and variable flow gas prior to pyrolysis. • An auxiliary unit running on the associated gas to power the GCU and MPU in an “island mode” configuration.

03 NATURAL GAS↗

Estimating internal moisture generation rates in recently constructed, occupied homes in the southeastern United States

Internal moisture generation (IMG), or moisture generated by building occupants via activities such as respiration, cooking, bathing, and cleaning, is a critical input required for design, analysis, and simulation of building enclosure and heating, ventilation, and air conditioning (HVAC) systems. Based on previously published values, ASHRAE Standard 160-2021 provides guidance for estimating IMG rates for moisture control design analysis, which is based on occupied home datasets collected in the 1980s and 1990s. Residential energy use simulation software also utilizes estimates for IMG for energy rating, energy analysis, and code compliance calculations, as specified in ANSI/RESNET/ICC Standard 301. Data quantifying IMG rates in newer homes is useful in determining the continued relevance of current design and simulation guidance, and whether the guidance represents conditions found in new housing stock. ASHRAE Research Project 1844, conducted by the Florida Solar Energy Center (FSEC), a research institute of the University of Central Florida, estimated IMG rates in newer occupied homes built since 2013 in the southeastern US using a moisture balance model approach. Furthermore, the project obtained occupied home data in cooperation with a US Department of Energy Building America research project to characterize indoor air quality (IAQ) in newer US homes, along with presence, functionality, and occupant use of control measures. Full-scale laboratory homes operating with known IMG rates were used to validate a moisture balance model and quantify the accuracy of estimates obtained when the model is applied to data from occupied homes with unknown IMG rates.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Performance Standards and Energy Code Alignment - Technical Brief

Building energy codes focus on building design, construction and renovation and have significantly increased building efficiency since the first national energy code was published in 1975. Most jurisdictions have energy codes based on ANSI/ASHRAE/IES Standard 90.1 (hereto referred to as Standard 90.1) and the International Energy Conservation Code (IECC). Compliance options available in these model energy codes include a prescriptive path, whole building performance paths – including IECC Total Building Performance (TBP), Standard 90.1 Energy Cost Budget (ECB) method and Performance Rating Method (PRM) – and system performance paths for envelope and heating, ventilation, and air-conditioning systems. Building performance standard (BPS) policies are an emerging policy tool used by jurisdictions to reduce the operational energy use or greenhouse gas (GHG) emissions of the existing commercial building stock. BPS policies vary widely between jurisdictions and are tailored to each location’s climate and energy goals. Intuitively, projects that met a recent edition of the energy code should comply with the BPS targets. However, some new buildings may struggle with meeting the BPS for the following reasons: 1. Energy codes focus on the design of the building and its projected ability to perform efficiently, while BPS compliance is dependent on the actual ongoing performance of the building, considering variables like occupancy, operation, and maintenance. 2. There are significant differences in the methodologies used to determine BPS compliance versus code compliance, including how each handles compliance metrics, handling of building amenities, and renewable energy generation. 3. The prescriptive compliance path in the energy code is based on performance of individual building components, as opposed to the performance compliance path which accounts for holistic building design strategies and interdependent building systems. This can result in a significant variability in post-occupancy performance for buildings built using the prescriptive path. Designs on the lower end of the permitted efficiency range may struggle with meeting the BPS.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Codisposal Waste Package Loading Options for DOE SNF and HLW PPT

The U.S. Department of Energy (DOE) is responsible for managing spent nuclear fuel (SNF) that is currently in, or will in the future come into, its possession. DOE must continue to safely store that SNF, transport it to an interim storage site or a repository, and dispose of it. These fuels come from a wide range of reactor types with various cladding materials and enrichments. Many of these reactors, now decommissioned, had unique design features, such as core configuration, fuel element and assembly geometry, moderator and coolant materials, operational characteristics, and neutron spatial and spectral properties, resulting in a large diversity of reactor and fuel designs. Because of the wide variety and conditions of SNF, a robust DOE Standard Canister was proposed that would confine radionuclides and preclude moderator. The DOE Standard Canister had four variations: 3.05-meter (10-foot) or 4.57-meter (15-foot) length, and 45.7-cm (18-inch) or 61.0-cm (24-inch) diameter. For ultimate disposal in the Yucca Mountain Repository, these canisters were to be grouped with 61.0-cm (24-inch) diameter high level waste (HLW) canisters in a 2.13-meter (84-inch) diameter co-disposal waste package. The smaller 45.7-cm (18-inch) diameter DOE Standard Canister could be placed in the middle of five HLW canisters. The larger 61.0-cm (24-inch) diameter DOE Standard Canister would take the place of one of the five HLW canisters on the outer ring in the co-disposal waste package. No DOE Standard Canisters have been loaded. A preliminary evaluation has estimated the number of elements of a fuel type that can fit into the different sizes of the DOE Standard Canister, but no definitive loading configuration has been selected. Changing the loading configuration could impact the number of loadable DOE Standard Canisters and the number of co-disposal waste packages needed for eventual disposition. This paper conveys the ranges of DOE Standard Canisters and HLW canisters that may be produced under certain conditions. It also examines the differences in the estimated number of co-disposal waste packages produced for eventual disposal when using different loading strategies in the DOE Standard Canister for Advanced Test Reactor (ATR), Peach Bottom, and High Flux Isotope Reactor (HFIR) SNF. Changing the loading configurations of ATR, Peach Bottom, and HFIR SNF slightly impacted the number of co-disposal waste packages that may be needed for ultimate disposal. The change in loading configuration was more impactful when a different canister was used, as opposed to varying the number of elements that could fit inside the same size canister. In one case, a reduction of co-disposal waste packages could be achieved by allowing mixing of short HLW canisters with long DOE Standard Canisters. The main conclusion from this analysis is that the ratio between HLW canisters and DOE Standard Canisters will drive the total number of co-disposal waste packages. If too many HLW canisters (i.e., more than five times the number of 18-inch DOE standard canisters) or DOE Standard Canisters are produced, some co-disposal waste packages may not have all positions filled. A co-disposal waste package may be filled with all HLW with no DOE Standard Canister, or a co-disposal waste package could be filled with a single DOE Standard Canister. A ratio that does not closely align to optimum could allow for the design of waste packages that hold just HLW canisters or just DOE SNF canisters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Modeling and Characterization of Surface Discharges in Insulating Material for Spacers: Electrode Shape, Discharge Mode, and Revision of the Creepage Concept

In the design of MV AC and DC spacers, the predominant factors are surface and interface conditions. Design is generally carried out on specifications and standards which are based on long-term experience and lab testing. However, the diffusion of power electronics with a trend to increase electric field, switching frequency, and rise time to achieve higher power density calls for an innovative, global approach to optimized insulation system design. A new methodology, based on field simulation, discharge modeling, and partial discharge inception measurements, called the three-leg approach, can form the basis to optimize insulation design for any type of supply voltage waveform. This paper focuses on the influence of the type of electrode on the inception and phenomenology of surface discharges and, as a consequence, on the interpretation of the results used for application of the three-leg approach. It is demonstrated that a typical electrode system used for insulating material testing can generate both gas and surface discharges at the triple point, when the electrodes have a smooth profile that is used to avoid corona or flashover. Hence, testing partial discharge may not provide a straightforward indication of the surface discharge inception and, thus, be partially misleading for insulation design. Another takeover is that such analysis must benefit from PD testing tools endowed with analytics able to provide automatic identification of the type of defect generating PD, i.e., internal, surface, and corona, since design and remedy actions can be taken, and adequate insulating materials developed, only knowing the type of source generating PD. Hence, testing partial discharge may not provide a straightforward indication of surface discharge inception and, thus, be partially misleading for insulation design. In addition to the importance of the three-leg approach to favor reliable and optimized design of insulation systems, there is a clear need to have a PD testing tool endowed with analytics. It should preferably be able to provide automatic identification of the type of defect generating PD, i.e., internal, surface, and corona.

36 MATERIALS SCIENCE↗

Building Performance Standards and Energy Code Alignment: Technical Brief

Building energy codes focus on building design, construction and renovation and have significantly increased building efficiency since the first national energy code was published in 1975. Most jurisdictions have energy codes based on ANSI/ASHRAE/IES Standard 90.1 (hereto referred to as Standard 90.1) and the International Energy Conservation Code (IECC). Compliance options available in these model energy codes include a prescriptive path, whole building performance paths – including IECC Total Building Performance (TBP), Standard 90.1 Energy Cost Budget (ECB) method and Performance Rating Method (PRM) – and system performance paths for envelope and heating, ventilation, and air-conditioning systems. Building performance standard (BPS) policies are an emerging policy tool used by jurisdictions to reduce the operational energy use or greenhouse gas (GHG) emissions of the existing commercial building stock. BPS policies vary widely between jurisdictions and are tailored to each location’s climate and energy goals. Intuitively, projects that met a recent edition of the energy code should comply with the BPS targets.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Massively scalable workflows for quantum chemistry: BigChem and ChemCloud

Electronic structure theory, i.e., quantum chemistry, is the fundamental building block for many problems in computational chemistry. Here we present a new distributed computing framework (BigChem), which allows for an efficient solution of many quantum chemistry problems in parallel. BigChem is designed to be easily composable and leverages industry-standard middleware (e.g., Celery, RabbitMQ, and Redis) for distributed approaches to large scale problems. BigChem can harness any collection of worker nodes, including ones on cloud providers (such as AWS or Azure), local clusters, or supercomputer centers (and any mixture of these). BigChem builds upon MolSSI packages, such as QCEngine to standardize the operation of numerous computational chemistry programs, demonstrated here with Psi4, xtb, geomeTRIC, and TeraChem. BigChem delivers full utilization of compute resources at scale, offers a programable canvas for designing sophisticated quantum chemistry workflows, and is fault tolerant to node failures and network disruptions. We demonstrate linear scalability of BigChem running computational chemistry workloads on up to 125 GPUs. Finally, we present ChemCloud, a web API to BigChem and successor to TeraChem Cloud. ChemCloud delivers scalable and secure access to BigChem over the Internet.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Standardization and First Lessons Learned of the Prototype HB650 Cryomodule for PIP-II at Fermilab

The prototype High Beta 650 MHz cryomodule (pHB650 CM) has been designed by an integrated design team, consisting of Fermilab (USA), CEA (France), STFC UKRI (UK), and RRCAT (India). The manufacturing and assembly of this prototype cryomodule is being done at Fermilab, whereas the production cryomodules will be manufactured and assembled by STFC-UKRI. As the first PIP-II cryomodule for which standardization was applied, the design, manufacturing and assembly of this cryomodule led to significant lessons being learnt and experiences gathered. These were incorporated into the design of the pre-production Single Spoke Resonator Type 2 cryomodule (ppSSR2 CM) and the pre-production Low Beta 650 MHz cryomodule (ppLB650 CM). This paper presents the pHB650 CM lessons learned and experiences gathered from the design to the lower coldmass assembly and how this cryomodule has a positive impact on all the next Proton Improvement Plan-II (PIP-II) cryomodules due to the standardization set up among SSR and 650 cryomodules.

43 PARTICLE ACCELERATORS↗

Co-Disposal Waste Package Loading Options for DOE SNF and HLW - 20331

The U.S. Department of Energy (DOE) is responsible for managing spent nuclear fuel (SNF) that is currently in, or will in the future come into, its possession. DOE must continue to safely store that SNF, transport it to an interim storage site or a repository, and dispose of it. These fuels come from a wide range of reactor types with various cladding materials and enrichments. Many of these reactors, now decommissioned, had unique design features, such as core configuration, fuel element and assembly geometry, moderator and coolant materials, operational characteristics, and neutron spatial and spectral properties, resulting in a large diversity of reactor and fuel designs. Because of the wide variety and conditions of SNF, a robust DOE Standard Canister was proposed that would confine radionuclides and preclude moderator. The DOE Standard Canister had four variations: 3.05-meter (10-foot) or 4.57-meter (15-foot) length, and 45.7-cm (18-inch) or 61.0-cm (24-inch) diameter. For ultimate disposal in the Yucca Mountain Repository, these canisters were to be grouped with 61.0-cm (24-inch) diameter high level waste (HLW) canisters in a 2.13-meter (84-inch) diameter co-disposal waste package. The smaller 45.7-cm (18-inch) diameter DOE Standard Canister could be placed in the middle of five HLW canisters. The larger 61.0-cm (24-inch) diameter DOE Standard Canister would take the place of one of the five HLW canisters on the outer ring in the co-disposal waste package. No DOE Standard Canisters have been loaded. A preliminary evaluation has estimated the number of elements of a fuel type that can fit into the different sizes of the DOE Standard Canister, but no definitive loading configuration has been selected. Changing the loading configuration could impact the number of loadable DOE Standard Canisters and the number of co-disposal waste packages needed for eventual disposition. This paper conveys the ranges of DOE Standard Canisters and HLW canisters that may be produced under certain conditions. It also examines the differences in the estimated number of co-disposal waste packages produced for eventual disposal when using different loading strategies in the DOE Standard Canister for Advanced Test Reactor (ATR), Peach Bottom, and High Flux Isotope Reactor (HFIR) SNF. Changing the loading configurations of ATR, Peach Bottom, and HFIR SNF slightly impacted the number of co-disposal waste packages that may be needed for ultimate disposal. The change in loading configuration was more impactful when a different canister was used, as opposed to varying the number of elements that could fit inside the same size canister. In one case, a reduction of co-disposal waste packages could be achieved by allowing mixing of short HLW canisters with long DOE Standard Canisters. The main conclusion from this analysis is that the ratio between HLW canisters and DOE Standard Canisters will drive the total number of co-disposal waste packages. If too many HLW canisters (i.e., more than five times the number of 18-inch DOE standard canisters) or DOE Standard Canisters are produced, some co-disposal waste packages may not have all positions filled. A co-disposal waste package may be filled with all HLW with no DOE Standard Canister, or a co-disposal waste package could be filled with a single DOE Standard Canister. A ratio that does not closely align to optimum could allow for the design of waste packages that hold just HLW canisters or just DOE SNF canisters. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reducing the Flow Maldistribution in Heat Exchangers through a Novel Polymer Manifold: Numerical Evaluation

The maldistribution of working fluid is one of the issues in heat exchangers that causes a reduction in performance of not only the heat exchanger but also the entire HVAC system. One of the methods to reduce such maldistribution is to improve manifold design to evenly distribute the flow. In the present work, an advanced maldistribution reduction manifold, which was based on a preliminary maldistribution reduction manifold, was designed to further improve the flow distribution in the heat exchanger. In the design, spiral baffles are used to create vortices in the tubes to regulate the flow in each tube. The design also keeps the tubes away from the manifold inlet to avoid direct flow from the inlet. Due to the complexity, the design of the advanced maldistribution reduction manifold is for AM only, which cannot be fabricated by traditional manufacturing. To evaluate the design, a computational fluid dynamic model is developed to study flow distribution in heat exchanger manifolds. The simulation results reveal that the relative standard deviation of the tubes in the advanced maldistribution reduction design is half of the preliminary maldistribution reduction design and about 1/20 of the reference design.

42 ENGINEERING↗

An Easy‐to‐Use Custom‐Built Cell for Neutron Powder Diffraction Studies of Rechargeable Batteries

Abstract In operando powder diffraction remains one of the most powerful tools for non‐destructive investigation of battery electrode materials. While in operando X‐ray, especially synchrotron radiation, powder diffraction is by now a routine experimental technique, in operando neutron powder diffraction is still less established. We present a new electrochemical cell for in operando neutron powder diffraction, which is, first and foremost, easy to use, but can also cycle electrode materials under electrochemical conditions close to those achieved using standard laboratory cells. The cell has been designed in multiple sizes, and high‐quality electrochemical and neutron powder diffraction data is presented for sample sizes as low as 48 mg total active material. The cell handles lithium‐ion and sodium‐ion materials equally well, with no difference in how the cell is prepared and assembled. The cell is intended to be used as sample environment at powder diffractometers at the neutron facilities MLZ, ORNL and ACNS.

25 ENERGY STORAGE↗