Search NASA⌕ Search

SEARCH · Search NASA

Results for “difference frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Millimeter-wave system-on-chip advancement for fusion plasma diagnostics

Recent advances in radio-frequency system-on-chip technology have provided mm-wave fusion plasma diagnostics with the capability to overcome major challenges such as space inefficiency, inflexible installation, sensitivity, susceptibility to EMI, and prohibitively high cost of conventional discrete component assemblies as higher imaging resolution and data accuracy are achieved by increasing the number of channels. Nowadays, shrinking transistor gate lengths on fabrication techniques have enabled hundreds of GHz operation, which is suitable for millimeter-wave diagnostics on current and future tokamaks. The Davis Millimeter Wave Research Center (DMRC) has successfully developed V-band (55-75 GHz) transmitter and receiver chips for Microwave Imaging Reflectometer (MIR) instruments. The transmitter can illuminate 8 different frequencies simultaneously within 55-75 GHz. Moreover, the receiver has the capability to amplify the reflected signal (>30 dB) while offering 10-30× reduction in noise temperature compared to current MIR instruments. Plasma diagnostics requires ultra-wideband (more than 20 GHz) operation which is approximately nine times wider bandwidth than the recent commercial impetus for communication systems. Current efforts are underway for gallium-arsenide monolithic microwave integrated circuit receiver chips at W-band (75-110 GHz) and F-band (90–140 GHz) permitting measurements at higher toroidal magnetic fields.

47 OTHER INSTRUMENTATION↗

SOL Reflectometer for Alcator C-Mod

A two-frequency x-mode reflectometer operating from 100 146 GHz is being deployed on Alcator C-Mod to measure the density profile and fluctuations in the scrape-off layer (SOL) immediately in-front of the new J-port ICRF antenna and the new B-port Lower Hybrid launcher. The reflectometer will cover densities from 1016 to 1020 m-3 at 5 5.4 T. To provide the greatest flexibility and capability to deal with density fluctuations approaching 100% peak to peak in the SOL, both full-phase and differential-phase measurement capabilities with sweep speeds of ~10 s to >1 ms are being implemented. The differential-phase measurement will use a difference-frequency of 500 MHz, corresponding to cutoff layer separations ranging from about 0.1 mm to 1 mm. The reflectometer will have 6 sets of launchers: 3 on the J-port ICRF antenna and 3 on the B-port LHRF launcher. The ICRF and LHRF antennas will incorporate reflectometer antennas at their top, bottom and mid-plane locations.

Hanson, Gregory R↗

How transparent is graphene? A surface science perspective on remote epitaxy

Remote epitaxy is the synthesis of a single crystalline film on a graphene-covered substrate, where the film adopts epitaxial registry to the substrate as if the graphene is transparent. Despite many exciting applications for flexible electronics, strain engineering, and heterogeneous integration, an understanding of the fundamental synthesis mechanisms remains elusive. Here we offer a perspective on the synthesis mechanisms, focusing on the foundational assumption of graphene transparency. We identify challenges for quantifying the strength of the remote substrate potential that permeates through graphene, and propose Fourier and beating analysis as a bias-free method for decomposing the lattice potential contributions from the substrate, from graphene, and from surface reconstructions, each at different frequencies. We highlight the importance of graphene-induced reconstructions on epitaxial templating, drawing comparison to moiré epitaxy. We highlight the role of the remote potential in tuning surface diffusion and adatom kinetics on graphene, which are crucial for navigating the competition between remote epitaxy and defect-seeded mechanisms like pinhole epitaxy. In light of this weak remote potential, we re-evaluate the current state-of-the-art experimental evidence, highlighting why it remains challenging to experimentally validate a ‘remote’ epitaxy mechanism that cannot be explained by alternatives, such as pinhole-seeded epitaxy or serial van der Waals epitaxy. We end with one experimental example that, to out knowledge, cannot be explained by competing mechanisms: a different long-range epitaxial relationship for GdPtSb films grown on graphene/sapphire, compared to direct epitaxy on sapphire. We suggest for future experiments that directly measure the remote potential and impact of tuneable growth kinetics.

epitaxy↗

Scrape-off layer reflectometer for Alcator C-Mod

A two-frequency x-mode reflectometer operating from 100 to 146 GHz is deployed on Alcator C-Mod to measure the density profile and fluctuations in the scrape-off layer (SOL) immediately in front of the new J-port ICRF antenna and the new C-port lower hybrid launcher. The reflectometer covers densities from 10{sup 16} to 10{sup 20} m{sup -3} at 5-5.4 T. To provide the greatest flexibility and capability to deal with density fluctuations approaching 100% peak-to-peak in the SOL, both full-phase and differential-phase measurement capabilities with sweep speeds of {approx}10 {mu}s to >1 ms are implemented. The differential-phase measurement uses a difference frequency of 500 MHz, corresponding to cutoff layer separations ranging from about 0.1 to 1 mm. The reflectometer has six sets of launchers: three on the ICRF antenna and three on the lower hybrid launcher. Both the ICRF antenna and the lower hybrid launcher incorporate reflectometer antennas at their top, bottom, and midplane locations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Precise measurement of hyperfine structure in the 2P{sub 1/2} state of {sup 7}Li using saturated-absorption spectroscopy

We report a precise measurement of the hyperfine interval in the 2P{sub 1/2} state of {sup 7}Li. The transition from the ground state (D{sub 1} line) is accessed using a diode laser and the technique of saturated-absorption spectroscopy in hot Li vapor. The interval is measured by locking an acousto-optic modulator to the frequency difference between the two hyperfine peaks. The measured interval of 92.040(6) MHz is consistent with an earlier measurement reported by us using an atomic-beam spectrometer [Das and Natarajan, J. Phys. B 41, 035001 (2008)]. The interval yields the magnetic dipole constant in the P{sub 1/2} state as A=46.047(3), which is discrepant from theoretical calculations by >80 kHz.

74 ATOMIC AND MOLECULAR PHYSICS↗

DOE EV Data Collection - Vehicle Data

Vehicle data consist of electric vehicle performance data collected directly from the vehicle during standard operations. Data were collected using onboard data loggers that were either installed by the project team or preinstalled by the original equipment manufacturer. Data recorded by the data loggers were made accessible via an online web portal or an application programming interface. Different data loggers were used (HEM, ViriCiti, and Geotab), and the method for each vehicle is defined in the vehicle attributes file. Some systems collected data on a “trip-level” basis, in which each row of a table represents a single trip (the period between a key-on and key-off event), whereas other data were collected on a per-day basis, in which each row represents a single day of operation. Data were collected over a range of data collection periods, depending on the project. Data have been anonymized by removing information or decreasing information resolution as necessary so that fleets are not identifiable. Due to the wide range of vehicle types represented and variation in data collection, data parameters and frequencies differ between vehicles and fleets The **Performance Data Daily/Trip Data Dictionaries** contain definitions for each available parameter associated with a vehicle’s operations, aggregated at either a daily or trip level. The parameters available will vary from vehicle to vehicle, but every possible parameter will be defined. The **Vehicle Attributes Data Dictionary** contains definitions for each available parameter associated with a vehicle’s physical and functional attributes and fleet context. The **Vehicle Attributes** table contains specific vehicle characteristics, coded to an anonymous Vehicle ID. This Vehicle ID can be used as a key between vehicle data and vehicle attribute tables. The **Vehicle Data** tables contain the data from each vehicle’s operations, aggregated at either a daily or trip level, coded to an anonymous Vehicle ID. This Vehicle ID can be used as a key between vehicle data and vehicle attribute tables. Data is being uploaded quarterly through 2023 and subject to change until the conclusion of the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Theoretical study on mode competition between fundamental and second harmonic modes in a 0.42 THz gyrotron with gradually tapered complex cavity

In this paper, the nonlinear dynamics of mode competition in the complex cavity gyrotron are studied by using multi-frequency, time-dependent theory with the cold-cavity longitudinal profile approximation. Based on the theory, a code is written to simulate the mode competition in the gradually tapered complex cavity gyrotron operating at second harmonic oscillation. The simulations tracking seven competition modes show that single mode oscillation of the desired mode TE{sub 17.4} at 150 kW level can be expected with proper choice of operating parameters. Through studying on mode competition, it is proved that the complex cavity has a good capability for suppressing the mode competition. Meanwhile, it is found that TE{sub 17.3} could be excited in the first cavity as a competition mode when the gyrotron operating at large beam current, which leads to that TE{sub 17.3} and TE{sub 17.4} with different frequencies can coexist stably in the complex cavity gyrotron with very close amplitudes. Thus, the complex cavity might be used for multi-frequency output gyrotron.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Root traits reveal safety and efficiency differences in grasses and shrubs exposed to different fire regimes

Plant roots are important components of terrestrial ecosystems, but little is known about how root traits differ between plant species or vary across space in natural ecosystems. In this study, we investigated how root traits vary across grasses and woody shrubs in a tallgrass prairie located in Manhattan, KS, USA. Specifically, were interested in understanding how anatomical traits vary across these different plant groups, across different depths in the soil, and also across multiple areas of tallgrass prairie that are burned at different frequencies. We compared traits that allow roots to use soil water efficiently and those that help roots persist through extended periods of drought. We found that woody roots exhibited traits that allow them to use water efficiently in shallow soils but persist through drought in deeper soil. Here, these traits may allow shrubs to transport water from shallow soils to deeper soil after large rain events and resist extended periods without rain when soils become dry, which may allow woody plants to successfully compete for water in less frequently burned, more diverse plant communities. Grasses had traits that allow them to use water efficiently but also tolerate drought in shallow soils, regardless of fire treatment. This unique trait combination likely gives grasses a competitive advantage over other tallgrass prairie plants across different fire regimes. Together, these results show that anatomical root traits can be used to enhance mechanistic understanding of plant functioning in dynamic ecosystems.

54 ENVIRONMENTAL SCIENCES↗

PKS 2155-304 in July 2006: H.E.S.S. results and simultaneous multi-wavelength observations

The high-frequency-peaked BL Lac PKS 2155-304 is one of the brightest and best-studied VHE {gamma}-ray sources in the southern hemisphere. The High Energy Stereoscopic System (H.E.S.S.) has monitored PKS 2155-304 in 2006 and a multi-wavelength campaign involving X-ray, optical and radio observatories was triggered by the detection of an active state in July 2006, followed by the detection of two extraordinary flares on July, 28th and 30th, with peak fluxes {approx}100 times the usual values. We present results from the spectral and flux variability analysis of the VHE and simultaneous X-ray observations with Chandra during the second flare, as well as the detailed evolution of the VHE flux of PKS 2155-304 observed by H.E.S.S. in 2006. A study of flux correlations in the different frequency ranges during the second flare and the adjacent nights is discussed. We also present an interpretation of the active state of PKS 2155-304 in the framework of synchrotron self-Compton emission.

79 ASTRONOMY AND ASTROPHYSICS↗

Harmonic and Subharmonic RF Injection Locking of THz Metasurface Quantum-Cascade VECSEL

Harmonic and subharmonic RF injection locking is demonstrated in a terahertz (THz) quantum-cascade vertical-external-cavity surface-emitting laser (QC-VECSEL). By tuning the RF injection frequency around integer multiples and submultiples of the cavity round-trip frequency, different harmonic and subharmonic orders can be excited in the same device. Modulation-dependent behavior of the device has been studied with recorded lasing spectral broadening and locking bandwidths in each case. In particular, harmonic injection locking results in the observation of harmonic spectra with bandwidths over 200 GHz. A semiclassical Maxwell-density matrix formalism has been applied to interpret QC-VECSEL dynamics, which aligns well with experimental observations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-loss millimeter-wave resonators with an improved coupling structure

Millimeter-wave superconducting resonators are a useful tool for studying quantum device coherence in a new frequency domain. However, improving resonators is difficult without a robust and reliable method for coupling millimeter-wave signals to 2D structures. We develop and characterize a tapered transition structure coupling a rectangular waveguide to a planar slotline waveguide with better than 0.5 dB efficiency over 14 GHz, and use it to measure ground-shielded resonators in the W band (75–110 GHz). Having decoupled the resonators from radiative losses, we consistently achieve single-photon quality factors above 10 5 , with a two-level-system loss limit above 10 6 , and verify the effectiveness of oxide removal treatments to reduce loss. These values are 4–5 times higher than those previously reported in the W band, and much closer to typical planar microwave resonators. The improved losses demonstrated by these on-chip millimeter-wave devices shed new light on quantum decoherence in a different frequency regime, offer increased selectivity for high-frequency detectors, and enables new possibilities for hybrid quantum experiments integrating millimeter-wave frequencies.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Stimulated Brillouin scattering of the beat wave of two lasers in a plasma

Stimulated Brillouin scattering of two collinear lasers in a plasma is investigated. Lasers exert a longitudinal ponderomotive force on electrons, imparting them oscillatory axial velocity at the beat frequency. This velocity acts as a driver for parametric excitation of an ion acoustic wave (omega,k-vector) and a noncollinear sideband electromagnetic wave (omega{sup '},k-vector{sup '}). The driver velocity v-vector{sub 0-} couples to the sideband wave to exert a ponderomotive force at (omega,k-vector) on the electrons, driving the ion acoustic wave. The density perturbation of ion acoustic wave beats with v-vector{sub 0-} to produce a nonlinear current at (omega{sup '},k-vector{sup '}), driving the sideband. In the case of finite spot size Gaussian laser beams, the beat wave has a Gaussian profile and excites an ion acoustic wave (omega,k-vector) and a backscattered TM mode (omega{sup '},k-vector{sub z}{sup '}). The growth rate scales as the product of amplitudes of the lasers and maximizes at optimum values of scattering angles. The parametric instability of difference frequency driver is stronger than the sum frequency driver.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beta-induced Alfven-acoustic eigenmodes in stellarator plasmas with low shear

The coupling of low-frequency Alfvenic modes with acoustic oscillations due to curvature of the background magnetic field is considered for stellarator plasmas with low shear. Magnetohydrodynamic (MHD) analysis demonstrates that the interaction between these branches can generate gaps in the continua with a width proportional to beta as well as the magnitude of the Fourier harmonics of the magnetic field strength which cause the coupling. The gaps can provide a habitat for beta-induced Alfven-acoustic eigenmodes (BAAEs). Using the causality principle, a technique is developed to resolve the singular behavior of the MHD BAAE eigenmode equation at the points of resonance with the acoustic continuum. Alternatively, the singularities arising in the reduced MHD description can be resolved by accounting for the finite parallel electrical field. Both approaches yield consistent continuum damping rate, which proves to be small. Numerical calculations for analytically fitted experimental profiles of electron-dominated plasma in Helically Symmetric eXperiment (HSX) facility yield two weakly damped BAAE modes with different frequencies: one is close to the maximum of the lower-frequency Alfven-acoustic continuum, and the other is located well within the BAAE gap. The numerically found BAAEs have frequencies in the same range as the experimentally observed electromagnetic modes in HSX, even when the finite diamagnetic frequency effects are considered.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tuning the work function of graphene by nitrogen plasma treatment with different radio-frequency powers

Graphene prepared by the chemical vapor deposition method was treated with nitrogen plasma under different radio-frequency (rf) power conditions in order to experimentally study the change in the work function. Control of the rf power could change the work function of graphene from 4.91 eV to 4.37 eV. It is shown that the increased rf power may lead to the increased number of graphitic nitrogen, increasing the electron concentration, and shifting the Fermi level to higher energy. The ability to controllably tune the work function of graphene is essential for optimizing the efficiency of optoelectronic and electronic devices.

36 MATERIALS SCIENCE↗

Ultrafast Plasmonic Control of Second Harmonic Generation

Efficient frequency conversion techniques are crucial to the development of plasmonic metasurfaces for information processing and signal modulation. In principle, nanoscale electric-field confinement in nonlinear materials enables higher harmonic conversion efficiencies per unit volume than those attainable in bulk materials. Here we demonstrate efficient second-harmonic generation (SHG) in a serrated nanogap plasmonic geometry that generates steep electric field gradients on a dielectric metasurface. An ultrafast control pulse is used to control plasmon-induced electric fields in a thin-film material with inversion symmetry that, without plasmonic enhancement, does not exhibit an even-order nonlinear optical response. The temporal evolution of the plasmonic near-field is characterized with ~100 as resolution using a novel nonlinear interferometric technique. The serrated nanogap is a unique platform in which to investigate optically controlled, plasmonically enhanced harmonic generation in dielectric materials on an ultrafast time scale. Lastly, this metamaterial geometry can also be readily extended to all-optical control of other nonlinear phenomena, such as four-wave mixing and sum- and difference-frequency generation, in a wide variety of dielectric materials.

36 MATERIALS SCIENCE↗

Electron-optical systems for planar gyrotrons

The methodology of designing an electron-optical system (EOS) that forms sheet helical electron beams (HEBs) for high-power gyrotrons is developed. As an example, we consider the EOS for a 140-GHz gyrotron operated at the first harmonic of the cyclotron frequency with an accelerating voltage of 50 kV, a beam current of 30 A, and a magnetic field compression of 36. A planar geometry of the magnetron-injection gun (MIG) is suggested. The adiabatic theory of MIGs modified for the planar geometry of EOS is used for preliminary estimations of MIG parameters. Numerical simulation of the HEB properties based on the CST STUDIO SUITE 3D code is performed to find the optimal configuration of a planar MIG. The accuracy of the calculated data is discussed. The main factors that affect the HEB quality are considered. It is shown that a sheet HEB with a pitch-factor of 1.3 and velocity spread not exceeding 25%–30% can be formed; this is quite acceptable for high-efficiency operation of modern gyrotrons. Calculation of the beam-wave interaction with the obtained HEB parameters proved that a high output power with a sufficiently good efficiency of about 20% can be reached. Simulations show the feasibility of the experimental implementation of a novel planar EOS and its use in short-wave planar gyrotrons. The developed technique can be used for the study and optimization of planar gyrotrons of different frequency bands and power levels.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dual-channel amplification in a single-mode diode laser for multi-isotope laser cooling

The output from two grating-stabilized external-cavity diode lasers were injected into a single-mode diode laser. Operating at a wavelength of 780 nm, this laser produced {approx}50 mW of power with two main frequency components of the same spectral characteristics of the seed lasers. The power ratio of the amplified components was freely adjustable due to gain saturation, and amplification was observed for frequency differences of the two seed lasers in the range from 73 MHz to 6.6 GHz. This system was used to realize a dual isotope magneto-optic trap (MOT) for rubidium ({sup 85}Rb and {sup 87}Rb). The resulting position and cloud size of the dual isotope MOT was the same as that of the single species MOTs to within {+-}10 and {+-}20 {mu}m, respectively. We also characterized the additional spectral components produced by four wave mixing (FWM) in the diode laser amplifier and utilized a particular FWM sideband to realize hyperfine pumping and subsequent laser trapping of {sup 85}Rb in the absence of a 'repump' laser dedicated to hyperfine pumping.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Hydrodynamic injection with pneumatic valving for microchip electrophoresis with total analyte utilization

A novel hydrodynamic injector that is directly controlled by a pneumatic valve has been developed for reproducible microchip capillary electrophoresis (CE) separations. The poly(dimethylsiloxane) (PDMS) devices used for evaluation comprise a separation channel, a side channel for sample introduction, and a pneumatic valve aligned at the intersection of the channels. A low pressure (≤ 3 psi) applied to the sample reservoir is sufficient to drive sample into the separation channel. The rapidly actuated pneumatic valve enables injection of discrete sample plugs as small as ~100 pL for CE separation. The injection volume can be easily controlled by adjusting the intersection geometry, the solution back pressure and the valve actuation time. Sample injection could be reliably operated at different frequencies (< 0.1 Hz to >2 Hz) with good reproducibility (peak height relative standard deviation ≤ 3.6%) and no sampling biases associated with the conventional electrokinetic injections. The separation channel was dynamically coated with a cationic polymer, and FITC-labeled amino acids were employed to evaluate the CE separation. Highly efficient (≥ 7.0 × 103 theoretical plates for the ~2.4 cm long channel) and reproducible CE separations were obtained. The demonstrated method has numerous advantages compared with the conventional techniques, including repeatable and unbiased injections, no sample waste, high duty cycle, controllable injected sample volume, and fewer electrodes with no need for voltage switching. The prospects of implementing this injection method for coupling multidimensional separations, for multiplexing CE separations and for sample-limited bioanalyses are discussed.

59 BASIC BIOLOGICAL SCIENCES↗