Search NASA⌕ Search

SEARCH · Search NASA

Results for “dosing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Using Auto-Segmentation to Reduce Contouring and Dose Inconsistency in Clinical Trials: The Simulated Impact on RTOG 0617

Contouring inconsistencies are known but understudied in clinical radiation therapy trials. We applied auto-contouring to the Radiation Therapy Oncology Group (RTOG) 0617 dose escalation trial data. We hypothesized that the trial heart doses were higher than reported due to inconsistent and insufficient heart segmentation. We tested our hypothesis by comparing doses between deep-learning (DL) segmented hearts and trial hearts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Long-Term Results of a Phase 1 Dose-Escalation Trial and Subsequent Institutional Experience of Single-Fraction Stereotactic Ablative Radiation Therapy for Liver Metastases

We report long-term outcomes from our phase 1 dose-escalation study to determine the maximum tolerated dose of single-fraction liver SABR pooled with our subsequent single institutional experience with patients treated postprotocol at the highest dose level (40 Gy) established from the phase 1 study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase I Trial of Stereotactic Body Radiation Therapy Dose Escalation in Pancreatic Cancer

Stereotactic body radiation therapy (SBRT) has demonstrated encouraging local tumor control rates in the treatment of pancreatic cancer, yet we lack prospective clinical trials evaluating dose-escalation strategies among patients treated with 5-fraction SBRT. This phase 1 dose-escalation trial was conducted to determine the maximum tolerated dose of SBRT in patients with pancreatic cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modern Radiation Therapy for Extranodal Nasal-Type NK/T-cell Lymphoma: Risk-Adapted Therapy, Target Volume, and Dose Guidelines from the International Lymphoma Radiation Oncology Group

In the multidisciplinary management of early-stage extranodal natural killer/T-cell lymphoma, nasal type (ENKTCL), with curative intent, radiation therapy is the most efficacious modality and is an essential component of a combined-modality regimen. In the past decade, utilization of upfront radiation therapy and non–anthracycline-based chemotherapy has improved treatment and prognosis. This guideline mainly addresses the heterogeneity of clinical features, principles of risk-adapted therapy, and the role and appropriate design of radiation therapy. Radiation therapy methods (including target volume definition, dose and delivery methods) are crucial for optimizing cure for patients with early-stage ENKTCL. The application of the principles of involved site radiation therapy in this lymphoma entity often leads to a more extended clinical target volume (CTV) than in other lymphoma types because it usually presents with primary tumor invasion, multifocal lesions, or extensive submucosal infiltration beyond the macroscopic disease. The CTV varies across different primary sites and is classified mainly into nasal, nonnasal upper aerodigestive tract (UADT), and extra-UADT entities. This review is a consensus of the International Lymphoma Radiation Oncology Group regarding the approach to radiation therapy, target-volume definition, optimal dose, and dose constraints in ENKTCL treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lung Cancer and Heart Disease Risks Associated With Low-Dose Pulmonary Radiotherapy to COVID-19 Patients With Different Background Risks

The respiratory disease COVID-19 reached global pandemic status in 2020. Excessive inflammation is believed to result in the most severe symptoms and death from this disease. Because treatment options for patients with severe COVID-19 related pulmonary symptoms remain limited, whole-lung low-dose radiation therapy is being evaluated as an anti-inflammatory modality. However, there is concern about the long-term risks associated with low-dose pulmonary irradiation. To help quantify the benefit-risk balance of low-dose radiation therapy for COVID-19, we estimated radiation-induced lifetime risks of both lung cancer and heart disease (major coronary events) for patients of different sexes, treated at ages 50 to 85, with and without other relevant risk factors (cigarette smoking and baseline heart disease risk).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Clinical Efficacy of Neoadjuvant Chemoradiation Therapy Between Lower and Higher Radiation Doses for Carcinoma of the Esophagus and Gastroesophageal Junction: A Systematic Review

Neoadjuvant concurrent chemoradiation therapy (nCRT) plus surgery has been a standard treatment for locoregionally advanced esophageal cancer and carcinoma of the gastroesophageal junction (EC/GEJ), but the optimal preoperative radiation dose is still unclear. We performed this systematic review to explore the treatment efficacy and toxicity of different radiation dose levels and find an optimal dose‐fractionation strategy in EC/GEJ patients receiving nCRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effects of Single-Dose Versus Hypofractionated Focused Radiation on Vertebral Body Structure and Biomechanical Integrity: Development of a Rabbit Radiation-Induced Vertebral Compression Fracture Model

Vertebral compression fracture is a common complication of spinal stereotactic body radiation therapy. Development of an in vivo model is crucial to fully understand how focal radiation treatment affects vertebral integrity and biology at various dose fractionation regimens. We present a clinically relevant animal model to analyze the effects of localized, high-dose radiation on vertebral microstructure and mechanical integrity. Using this model, we test the hypothesis that fractionation of radiation dosing can reduce focused radiation therapy's harmful effects on the spine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Irradiation at Ultra-High (FLASH) Dose Rates Reduces Acute Normal Tissue Toxicity in the Mouse Gastrointestinal System

Preclinical studies using ultra-high dose rate (FLASH) irradiation have demonstrated reduced normal tissue toxicity compared with conventional dose rate (CONV) irradiation, although this finding is not universal. We investigated the effect of temporal pulse structure and average dose rate of FLASH compared with CONV irradiation on acute intestinal toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calculations versus measurements for residual dose rates from SNS spent structures

Here, residual dose rate measurements were conducted on target vessel #13 and proton beam window #5 after extraction from their service locations. These measurements are used to verify calculation methods of radionuclide inventory assessment that are typically performed for nuclear waste characterization and transportation of these structures. Neutronics analyses for predicting residual dose rates are carried out using the transport code MCNPX and the transmutation code CINDER90. For transport analyses a complex and rigorous geometry model of the structures and their surroundings are applied. The neutronics analyses are carried out using the Bertini and CEM high energy physics models for simulating particles interactions above the table-based cross section range. Finally, obtained calculational results are analyzed and compared to the measured dose rates and overall show good agreement within 25%, which shows applicability of the methods used in analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of Low Dose Silicon Carbide Temperature Monitors

Thermocouples are generally used to provide real-time temperature indications in instrumented tests performed at materials and test reactors. Melt wires or paint spots are often included in such tests as an independent technique of detecting peak temperatures incurred during irradiation. In addition, less expensive static capsule tests, which have no leads attached for real-time data transmission, often rely on melt wires and paint spots as a post-irradiation technique for peak temperature indication. Unfortunately, these techniques are limited in that they can only detect whether a single temperature is or is not exceeded. Silicon carbide (SiC) monitors are advantageous because a single monitor can be used to determine the peak temperature reached within a relatively broad range (200 – 800°C). Although the use of SiC monitors was proposed more than five decades ago, the ultimate performance limits of this technique are not fully understood. The Nuclear Science User Facilities (NSUF) is the United States Department of Energy Office of Nuclear Energy's only designated nuclear energy user facility. Its mission is to provide nuclear energy researchers access to world-class capabilities and to facilitate the advancement of nuclear science and technology. This mission is supported by providing access to state-of-the-art experimental irradiation testing, post irradiation examination facilities, and high performance computing capabilities as well as technical and scientific assistance for the design and execution of projects. As part of an NSUF project, low dose silicon carbide monitors were irradiated in the Belgian Reactor 2 and were then evaluated both at the SCK•CEN and at Idaho National Laboratory's High Temperature Test Laboratory to determine their peak temperature achieved during irradiation. The technical significance of this work was that the monitors were irradiated to a dose that was significantly less than recommended in published literature. This paper will discuss the evaluation process, the irradiation test, and the performance of the low dose silicon carbide temperature monitors.

36 MATERIALS SCIENCE↗

Emergency Radiation Dose Rate Monitoring During Prolonged Armed Conflict

The 2022 Russian full-scale invasion of Ukraine has introduced unprecedented challenges for the nuclear power generation and radiological safety communities, including occupation and disturbance of highly-contaminated areas, occupation of a nuclear power plant, and strikes near and within boundaries of nuclear sites. The war has necessitated the implementation of a supplementary dose rate sensor network to provide resilient measurement data for public protection and leadership awareness. This paper discusses the implementation of such a system, the factors determining what equipment is best suited for the purpose, and practical factors regarding deployment of the system and data management. The crucial factors for operating a supplementary dose rate sensing network are backup power and communications options for dose rate sensors to make the network resilient to the effects of military operations. The most important implementation factor is to plan for extended operations beyond those typically considered for emergency response given the unpredictable nature of warfare.

resilience↗

Zika virus dynamics: Effects of inoculum dose, the innate immune response and viral interference

Experimental Zika virus infection in non-human primates results in acute viral load dynamics that can be well-described by mathematical models. The inoculum dose that would be received in a natural infection setting is likely lower than the experimental infections and how this difference affects the viral dynamics and immune response is unclear. Here we study a dataset of experimental infection of non-human primates with a range of doses of Zika virus. We develop new models of infection incorporating both an innate immune response and viral interference with that response. We find that such a model explains the data better than models with no interaction between virus and the immune response. We also find that larger inoculum doses lead to faster dynamics of infection, but approximately the same total amount of viral production.

59 BASIC BIOLOGICAL SCIENCES↗

Plutonium in Manhattan Project workers: Using autopsy data to evaluate organ content and dose estimates based on urine bioassay with implications for radiation epidemiology

Purpose Radiation dose estimates in epidemiology typically rely on intake predictions based on urine bioassay measurements. The purpose of this article is to compare the conventional dosimetric estimates for radiation epidemiology with the estimates based on additional post-mortem tissue radiochemical analysis results. Methods The comparison was performed on a unique group of 11 former Manhattan Project nuclear workers, who worked with plutonium in the 1940s, and voluntarily donated their bodies to the United States Transuranium and Uranium Registries. Results Post-mortem organ activities were predicted using different sets of urine data and compared to measured activities. Use of urinalysis data collected during the exposure periods overestimated the systemic (liver+skeleton) deposition of 239 Pu by 155±134%, while the average bias from using post-exposure urinalyses was –4±50%. Committed effective doses estimated using early urine data differed from the best estimate by, on average, 196±193%; inclusion of follow-up urine measurements in analyses decreased the mean bias to 0.6±36.3%. Cumulative absorbed doses for the liver, red marrow, bone surface, and brain were calculated for the actual commitment period. Conclusion On average, post-exposure urine bioassay results were in good agreement with post-mortem tissue analyses and were more reliable than results of urine bioassays collected during the exposure.

60 APPLIED LIFE SCIENCES↗

Clustered DNA damages induced in human hematopoietic cells by low doses of ionizing radiation

Ionizing radiation induces clusters of DNA damages--oxidized bases, abasic sites and strand breaks--on opposing strands within a few helical turns. Such damages have been postulated to be difficult to repair, as are double strand breaks (one type of cluster). We have shown that low doses of low and high linear energy transfer (LET) radiation induce such damage clusters in human cells. In human cells, DSB are about 30% of the total of complex damages, and the levels of DSBs and oxidized pyrimidine clusters are similar. The dose responses for cluster induction in cells can be described by a linear relationship, implying that even low doses of ionizing radiation can produce clustered damages. Studies are in progress to determine whether clusters can be produced by mechanisms other than ionizing radiation, as well as the levels of various cluster types formed by low and high LET radiation.

NASA Discipline Radiation Health↗

Alterations in dose and lineal energy spectra under different shieldings in the Los Alamos high-energy neutron field

Nuclear interactions of space radiation with shielding materials result in alterations in dose and lineal energy spectra that depend on the specific elemental composition, density and thickness of the material. The shielding characteristics of materials have been studied using charged-particle beams and radiation transport models by examining the risk reduction using the conventional dose-equivalent approach. Secondary neutrons contribute a significant fraction of the total radiation exposure in space. An experiment to study the changes in dose and lineal energy spectra by shielding materials was carried out at the Los Alamos Nuclear Science Center neutron facility. In the energy range of about 2 to 200 MeV, this neutron spectrum is similar in shape within a factor of about 2 to the spectrum expected in the International Space Station habitable modules. It is shown that with a shielding thickness of about 5 g cm(-2), the conventional radiation risk increases, in some cases by as much as a factor of 2, but decreases with thicknesses of about of 20 g cm(-2). This suggests that care must be taken in evaluating the shielding effectiveness of a given material by including both the charged-particle and neutron components of space radiation.

NASA Discipline Radiation Health↗

Dose-response relationship for light intensity and ocular and electroencephalographic correlates of human alertness

Light can elicit both circadian and acute physiological responses in humans. In a dose response protocol men and women were exposed to illuminances ranging from 3 to 9100 lux for 6.5 h during the early biological night after they had been exposed to <3 lux for several hours. Light exerted an acute alerting response as assessed by a reduction in the incidence of slow-eye movements, a reduction of EEG activity in the theta-alpha frequencies (power density in the 5-9 Hz range) as well as a reduction in self-reported sleepiness. This alerting response was positively correlated with the degree of melatonin suppression by light. In accordance with the dose response function for circadian resetting and melatonin suppression, the responses of all three indices of alertness to variations in illuminance were consistent with a logistic dose response curve. Half of the maximum alerting response to bright light of 9100 lux was obtained with room light of approximately 100 lux. This sensitivity to light indicates that variations in illuminance within the range of typical, ambient, room light (90-180 lux) can have a significant impact on subjective alertness and its electrophysiologic concomitants in humans during the early biological night.

Clinical Trial↗

Compendium of Single Event Effects, Total Ionizing Dose, and Displacement Damage for Candidate Spacecraft Electronics for NASA

We present results and analysis investigating the effects of radiation on a variety of candidate spacecraft electronics to proton and heavy ion induced single event effects (SEE), proton-induced displacement damage (DD), and total ionizing dose (TID). Introduction: This paper is a summary of test results.NASA spacecraft are subjected to a harsh space environment that includes exposure to various types of ionizing radiation. The performance of electronic devices in a space radiation environment is often limited by its susceptibility to single event effects (SEE), total ionizing dose (TID), and displacement damage (DD). Ground-based testing is used to evaluate candidate spacecraft electronics to determine risk to spaceflight applications. Interpreting the results of radiation testing of complex devices is quite difficult. Given the rapidly changing nature of technology, radiation test data are most often application-specific and adequate understanding of the test conditions is critical. Studies discussed herein were undertaken to establish the application-specific sensitivities of candidate spacecraft and emerging electronic devices to single-event upset (SEU), single-event latchup (SEL), single-event gate rupture (SEGR), single-event burnout (SEB), single-event transient (SET), TID, enhanced low dose rate sensitivity (ELDRS), and DD effects.

Single Event Effects↗