Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron beam imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Shower Reconstruction for Cross-Section Measurements with Photon(s) in the Final State at SBND

The Short-Baseline Near Detector (SBND) is a 112-ton liquid argon time projection chamber operating in the Booster Neutrino Beam at Fermilab as part of the Short-Baseline Neutrino Program. Precise reconstruction of electromagnetic showers from photons and electrons is essential for searches for neutrino oscillations, cross-section measurements, and rare-process studies in liquid argon. In this poster, we present a unified set of SBND analyses enabled by the SPINE (Scalable Particle Imaging with Neural Embeddings) end-to-end machine-learning–based reconstruction framework, highlighting charged-current neutral pion (CC π⁰) production and neutral-current (NC) Δ radiative decay as complementary physics cases. Charged-current π⁰ interactions provide a high-statistics benchmark for validating photon reconstruction, constraining the electromagnetic energy scale, and modeling backgrounds to other cross-section measurements and BSM searches with one or more photons in the final state. We summarize progress toward the ongoing development of a CC π⁰ selection in SBND and, report on the current status of a search for NC resonant Δ production followed by radiative decay (Δ→Nγ) in SBND. This rare process, previously investigated in MicroBooNE, provides a stringent test of photon-only final-state reconstruction and is of interest in the context of the MiniBooNE low-energy excess. Together, these analyses demonstrate how modern machine-learning–based shower reconstruction enables a diverse and scalable physics program at SBND.

Chung, Seokju [Nevis Labs, Columbia U.]↗

Electromagnetic shower reconstruction in the ICARUS liquid argon time projection chamber detector

The ICARUS-T600 liquid argon time projection chamber (LArTPC) detector is taking data at shallow depth as the far detector of the Short Baseline Neutrino (SBN) program at Fermilab, to search for a possible sterile neutrino signal at $\Delta m^{2} \approx 1~\text{eV}^{2}$ with the Booster (BNB) and Main Injector (NuMI) neutrino beams at $\GeV{\sim 0.8}$ and $\GeV{\sim 2}$ average energies respectively. The LArTPC technology, developed by the ICARUS collaboration and now a standard in neutrino physics, offers impressive charged-particle imaging capabilities with $\sim1 \ \text{mm}$ spatial resolution, enabling efficient discrimination between track-like signatures (e.g., from muons, pions, and protons) and electromagnetic showers (from electrons and photons). Moreover, electron and photon signatures can be distinguished both with the calorimetric measurement of local energy depositions at the shower start and with the cm-scale conversion gap signature of photons. This contribution discusses event reconstruction at ICARUS focusing on Pandora, a multi-algorithm pattern recognition software widely used in LArTPC experiments. Over a hundred Pandora algorithms and tools are used to reconstruct cosmic rays and neutrino interactions in the ICARUS detector. Recent developments have focused on the reconstruction of electromagnetic shower signatures, crucial to ensure a robust and efficient reconstruction of charged-current $\nu_e$ interactions, which serve as a key signature of sterile neutrino oscillations at SBN. In this contribution, recent improvements to the reconstruction are discussed, focusing on the discrimination between tracks and electromagnetic showers using neutrino simulations and data.

Triozzi, Riccardo [Padua U.; INFN, Padua] (ORCID:0↗

Diffraction data from aerosolized Coliphage PR772 virus particles imaged with the Linac Coherent Light Source

Single Particle Imaging (SPI) with intense coherent X-ray pulses from X-ray free-electron lasers (XFELs) has the potential to produce molecular structures without the need for crystallization or freezing. Here we present a dataset of 285,944 diffraction patterns from aerosolized Coliphage PR772 virus particles injected into the femtosecond X-ray pulses of the Linac Coherent Light Source (LCLS). Additional exposures with background information are also deposited. The diffraction data were collected at the Atomic, Molecular and Optical Science Instrument (AMO) of the LCLS in 4 experimental beam times during a period of four years. The photon energy was either 1.2 or 1.7 keV and the pulse energy was between 2 and 4 mJ in a focal spot of about 1.3 μm x 1.7 μm full width at half maximum (FWHM). The X-ray laser pulses captured the particles in random orientations. The data offer insight into aerosolised virus particles in the gas phase, contain information relevant to improving experimental parameters, and provide a basis for developing algorithms for image analysis and reconstruction.

59 BASIC BIOLOGICAL SCIENCES↗

STEM Ptychographic Holography of Electric and Magnetic Potentials

The development of fast an efficient direct electron imaging detectors have enabled the advancement of phase-imaging techniques in STEM such as iterative ptychography. As beneficial as these techniques are to imaging phase objects, the information recorded in the raw data is due to phase gradients across the probe, so it can be challenging to reconstruct slowly varying phase at lower spatial frequencies such as those induced by electric or magnetic potentials within the specimen. STEM holography [1,2] is an interferometric 4D-STEM technique where electrons in the beam are coherently divided into a superposition of two or more spatially separated probes which are then scanned over the specimen. For example, in a two-beam superposition, the two probes form overlapping bright field discs at the detector which then interfere (left of Fig. 1). Furthermore, if one probe passes through vacuum while the other transmits through the specimen, the resulting relative phase shift can be measured by recording shifts in the interference pattern. STEM holography is thus directly sensitive to the phase of the probe relative to the reference beam, and this phase can be measured regardless of the convergence angle of the probe, unlike single beam ptychography.

Biological Sciences↗

3D imaging of magnetic domains in Nd 2 Fe 14 B using scanning hard X-ray nanotomography

Nanoscale structural and electronic heterogeneities are prevalent in condensed matter physics. Investigating these heterogeneities in 3D has become an important task for understanding material properties. To provide a tool to unravel the connection between nanoscale heterogeneity and macroscopic emergent properties in magnetic materials, scanning transmission X-ray microscopy (STXM) is combined with X-ray magnetic circular dichroism. A vector tomography algorithm has been developed to reconstruct the full 3D magnetic vector field without any prior noise assumptions or knowledge about the sample. Two tomographic scans around the vertical axis are acquired on single-crystalline Nd 2 Fe 14 B pillars tilted at two different angles, with 2D STXM projections recorded using a focused 120 nm X-ray beam with left and right circular polarization. Image alignment and iterative registration have been implemented based on the 2D STXM projections for the two tilts. Dichroic projections obtained from difference images are used for the tomographic reconstruction to obtain the 3D magnetization distribution at the nanoscale.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Single-shot ionization-based monitor for pulsed electron beams

In this work, we present an experimental demonstration of a single-shot, nondestructive electron beam diagnostic based on the ionization of a low-density pulsed gas jet. In our study, 7 MeV electron bunches from a radio-frequency photoinjector, carrying up to 100 pC of charge, traversed a localized distribution of nitrogen gas (N 2 ). The interaction of the electron bunches with the N 2 gas generated a correlated signature in the ionized particle distribution, which was spatially magnified using a series of electrostatic lenses and recorded with a microchannel-plate detector. Various modalities, including point-to-point imaging and velocity mapping, are investigated. A temporal trace of the detector current enabled the identification of single- and double-ionization events. The characteristics of the ionization distribution, dependence on gas density, total bunch charge, and other parameters, are described. Approaches to scaling to higher electron bunch density and energy are suggested. Additionally, the instrument proves useful for comprehensive studies of the ionization process itself.

47 OTHER INSTRUMENTATION↗

Low Repetition-Rate, High-Resolution Femtosecond Transmission Electron Microscopy

Spatial and energy resolutions of state-of-the-art transmission electron microscopes (TEMs) have surpassed 50 pm and 5 meV. However, with respect to the time domain, even the fastest detectors combined with the brightest sources may only be able to reach the microsecond timescale. Thus, conventional methods are incapable of resolving myriad fundamental ultrafast (i.e., attosecond to picosecond) atomic-scale dynamics. The successful demonstration of femtosecond (fs) laser-based (LB) ultrafast transmission electron microscopy (UEM) nearly 20 years ago provided a means to span this nearly 10-order-of-magnitude temporal gap. While nanometer-picosecond UEM studies of dynamics are now well established, ultrafast Å-scale imaging has gone largely unrealized. Further, while instrument development has rightly been an emphasis, and while new modalities and uses of pulsed-beam TEM continue to emerge, the overall chemical and materials application space has been only modestly explored to date. In this Perspectives article, we argue that these apparent shortfalls can be attributed to a simple lack of data and detail. We speculate that present work and continued growth of the field will ultimately lead to the realization that Å-scale fs dynamics can indeed be imaged with minimally modified UEM instrumentation and with repetition rates (f rep ) below - and perhaps even well below - 1 MHz. We further argue that use of low f rep , whether for LB UEM or for chopped/bunched beams, significantly expands the accessible application space. Furthermore, this calls for systematically establishing modality-specific limits so that especially promising technologies can be pursued, thus ultimately facilitating broader adoption as individual instrument capabilities expand.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing the meta-stability of oxide core/shell nanoparticle systems at atomic resolution

Hybrid nanoparticles allow exploiting the interplay of confinement, proximity between different materials and interfacial effects. However, to harness their properties an in-depth understanding of their (meta)stability and interfacial characteristics is crucial. This is especially the case of nanosystems based on functional oxides working under reducing conditions, which may severely impact their properties. Here, the in-situ electron-induced selective reduction of Mn 3 O 4 to MnO is studied in magnetic Fe 3 O 4 /Mn 3 O 4 and Mn 3 O 4 /Fe 3 O 4 core/shell nanoparticles by means of high-resolution scanning transmission electron microscopy combined with electron energy-loss spectroscopy. Such in-situ transformation allows mimicking the actual processes in operando environments. A multi-stage image analysis using geometric phase analysis combined with particle image velocity enables direct monitoring of the relationship between structure, chemical composition and strain relaxation during the Mn 3 O 4 reduction. In the case of Fe 3 O 4 /Mn 3 O 4 core/shell the transformation occurs smoothly without the formation of defects. However, for the inverse Mn 3 O 4 /Fe 3 O 4 core/shell configuration the electron beam-induced transformation occurs in different stages that include redox reactions and void formation followed by strain field relaxation via formation of defects. This study highlights the relevance of understanding the local dynamics responsible for changes in the particle composition in order to control stability and, ultimately, macroscopic functionality.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermally Grown Oxide Stress in PS-PVD and EB-PVD Thermal Barrier Coatings Observed at Various Lifetimes Via Synchrotron X-ray Diffraction

The current standard application method for thermal barrier coatings (TBCs) on turbine blades for jet engines is electron-beam physical vapor deposition (EB-PVD) due to its high strain tolerance and low thermal conductivity. An emerging deposition method, plasma-spray physical vapor deposition (PS-PVD), presents an opportunity for a tailorable microstructure, and non-line-of-sight deposition that is faster and less expensive. To compare the lifetime behavior of both PS-PVD and EB-PVD coatings, samples subjected to 300 and 600 thermal cycles were measured during a 1 h thermal cycle to determine the strains, which were converted to stress, in the thermally grown oxide (TGO) layer of the TBCs using synchrotron X-ray diffraction (XRD). Room temperature XRD measurements indicated among samples that PS-PVD coatings experienced greater variation in in-plane room temperature strain in the TGO after cycling than the EB-PVD coatings. In-situ XRD measurements indicated similar high-temperature strain and no spallation after 600 thermal cycles for both coatings. Further, microscopy imaging after cycling showed greater rumpling in PS-PVD coatings that led to different failure modes between the two coatings’ TGO layers. The tailorability of PS-PVD coatings allows for adjustments in the processing parameters to improve their overall performance after aging and bridge the differences between the two deposition methods.

36 MATERIALS SCIENCE↗

Flow Induced Vibration Studies in Pressurized Helium Gas Cooling Channels

Production of metastable Technetium-99 (Tc-99m), a radioactive tracer that emits gamma rays, is vital to the medical imaging community. Tc-99m is extracted from the decay of Molybdenum-99 (Mo-99) which has a half-life of about 2-3 days. The work presented in this report is part of the NNSA’s mission to produce Mo-99 commercially, within the US, without the use of highly enriched uranium (HEU) in support of nonproliferation and global security. Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 through the irradiation of Mo-100 targets using an electron beam. The NMR target comprises a stack of approximately 60-70 Mo-100 disks with diameter 24 mm and thickness 0.74 mm held in stainless steel laminations, each separated using 0.25 mm thick stainless steel spacers. The symmetric target stack is housed in an Inconel vessel with two Inconel windows on either side. Two electron accelerators are used to produce 40 MeV, 3.16 µA electron beams each that penetrate the Inconel windows and irradiate the Mo-100 disks. Approximately 90% of the total 250 kW beam power is deposited in the NMR target during the irradiation process. During irradiation, pressurized helium gas flows through 0.25 mm thin gaps between the disks cooling the beam window, target disks, disk laminations and spacers. Both NMR and LANL have found during cold testing of the target system (no heat deposition) that the Mo-100 disks undergo significant mass loss and disk breakage due to vibrations induced by the flowing helium gas. The mass loss is not only undesirable due to monetary loss from reduced final quantities of Mo-99, but also due to the hazards associated with radioactive material trapped in the cooling lines and particle filters. The effect of flow rate and target geometry on the flow induced vibrations need to be quantified, and recommendations provided to minimize this mass loss. This work describes LANL’s experimental characterization of the flow induced vibrations and disk mass loss in a reduced scale set-up containing 10 Mo-100 disks. We use high speed imaging, displacement measurements and microphone measurements combined with signal processing to estimate the vibration frequency of each disk. The effect of disk thickness, target fit and duration of testing on the mass loss is described. We find that in the current configuration of NMR targets, the vibrations and mass loss on the first disk are minimized, while those in the adjacent disks are highest. The microphone and high-speed image data show that increased flow rates and increased duration of testing increases vibration frequency and mass loss. The mass loss is due to both disk rotation and back and forth motion. There are visible wear marks on the disks with the highest mass loss. We also note that the current NMR window gap reduces flow induced vibrations compared to the previous smaller gaps. Longer duration testing will provide more data and verification for the findings presented in this report. The work will be continued in FY 24.

43 PARTICLE ACCELERATORS↗

An ultra-compact x-ray free-electron laser

In the field of beam physics, two frontier topics have taken center stage due to their potential to enable new approaches to discovery in a wide swath of science. These areas are: advanced, high gradient acceleration techniques, and x-ray free electron lasers (XFELs). Further, there is intense interest in the marriage of these two fields, with the goal of producing a very compact XFEL. In this context, recent advances in high gradient radio-frequency cryogenic copper structure research have opened the door to the use of surface electric fields between 250 and 500 MV m -1 . Such an approach is foreseen to enable a new generation of photoinjectors with six-dimensional beam brightness beyond the current state-of-the-art by well over an order of magnitude. This advance is an essential ingredient enabling an ultra-compact XFEL (UC-XFEL). In addition, one may accelerate these bright beams to GeV scale in less than 10 m. Such an injector, when combined with inverse free electron laser-based bunching techniques can produce multi-kA beams with unprecedented beam quality, quantified by 50 nm-rad normalized emittances. The emittance, we note, is the effective area in transverse phase space (x, p x /m e c) or (y, p y /m e c) occupied by the beam distribution, and it is relevant to achievable beam sizes as well as setting a limit on FEL wavelength. These beams, when injected into innovative, short-period (1–10 mm) undulators uniquely enable UC-XFELs having footprints consistent with university-scale laboratories. We describe the architecture and predicted performance of this novel light source, which promises photon production per pulse of a few percent of existing XFEL sources. We review implementation issues including collective beam effects, compact x-ray optics systems, and other relevant technical challenges. To illustrate the potential of such a light source to fundamentally change the current paradigm of XFELs with their limited access, we examine possible applications in biology, chemistry, materials, atomic physics, industry, and medicine—including the imaging of virus particles—which may profit from this new model of performing XFEL science.

47 OTHER INSTRUMENTATION↗

Experimental setup for high-resolution characterization of crystal optics for coherent X-ray beam applications

Stanford Synchrotron Radiation Lightsource serves a wide scientific community with its variety of X-ray capabilities. Recently, a wiggler X-ray source located at beamline 10-2 has been employed to perform high-resolution rocking curve imaging (RCI) of diamond and silicon crystals. X-ray RCI is invaluable for the development of upcoming cavity-based X-ray sources at SLAC, including the cavity-based X-ray free-electron laser and X-ray laser oscillator. In this paper, the RCI apparatus is described and experimental results are provided to validate its design. Future improvements of the setup are also discussed.

36 MATERIALS SCIENCE↗

Integrated fluorescence light microscopy-guided cryo-focused ion beam-milling for in situ montage cryo-ET

Cryogenic-electron tomography (cryo-ET) permits the in situ visualization of biological macromolecules at the molecular level. Owing to the variable thickness of cells, tissues and organisms, frozen specimens may need to be thinned by cryo-focused ion beam (FIB) milling to produce thin (<500 nm) cryo-lamellae suitable for cryo-ET. Locating regions of interest remains a challenge because untargeted milling can lead to inadvertent ablation and removal of regions of interest. Correlative light and electron microscopy, combined with cryo-FIB milling, can guide the identification of labeled targets in the cellular milieu. Multiple transfers between cryo-imaging instruments, cumbersome correlation algorithms, limited accuracy and low throughput have hindered the routine adoption of cryo-FIB milling within a multimodal correlative workflow for in situ structural biology. Here, in this study, we present a workflow for 3D correlative cryo-fluorescence light microscopy-FIB-ET that streamlines fluorescence light microscopy-guided FIB milling, improving throughput while preserving both structural and contextual information. The complete integration of hardware and software described here minimizes sample contamination from cross-platform exchanges and greatly enhances the efficiency of 3D targeting in cryo-milling. We then describe procedures for implementing montage parallel array cryo-ET (MPACT), which can be easily adapted to any modern life-science transmission electron microscope. MPACT supports high-throughput cryo-ET acquisitions (10 tilt series in 1.5 h) for structure determination and comprehensive contextual understanding of macromolecules within their native surroundings. A complete session from sample preparation to MPACT data processing takes 5−7 d for an individual experienced in both cryo-EM and cryo-FIB milling.

Yang, Jie E. [Univ. of Wisconsin, Madison, WI (Uni↗

Multidimensional images and aberrations in STEM

Recent advances in scanning transmission electron microscopy (STEM) have led to increased development of multi-dimensional STEM imaging modalities and novel image reconstruction methods. This interest arises because the main electron lens in a modern transmission electron microscope usually has a diffraction-space information limit that is significantly better than the real-space resolution of the same lens. This state-of-affairs is sometimes shared by other scattering methods in modern physics and contributes to a broader excitement surrounding multidimensional techniques that scan a probe while recording diffraction-space images, such as ptychography and scanning nano-beam diffraction. However, the contrasting resolution in the two spaces raises the question as to what is limiting their effective performance. Here, we examine this paradox by considering the effects of aberrations in both image and diffraction planes, and likewise separate the contributions of pre- and post-sample aberrations. In conclusion, this consideration provides insight into aberration-measurement techniques and might also indicate improvements for super-resolution techniques.

Hoglund, Eric R.↗

Investigation of low-energy particle remnants in high-energy collisions at the LHC with a skipper-CCD detector

We deployed the Mobile Skipper Testing Apparatus ∼33 m away from the Compact Muon Solenoid collision point, the first skipper-CCD detector probing low-energy particles produced in high-energy collisions at the Large Hadron Collider. In this work, we search for beam-related events using data collected in 2024 during beam-on and beam-off periods. The dataset corresponds to integrated luminosities of 113.3 fb −1 and 1.54 nb −1 for the proton-proton and Pb-Pb collision periods, respectively. We report observed event rates in a model-independent framework across two ionization regions: ≤ 20⁢𝑒 − and > 20⁢𝑒 − . For the low-energy region, we perform a likelihood analysis to test the null hypothesis of no beam-correlated signal. We found no significant correlation during proton-proton and Pb-Pb collisions. For the high-energy region, we present the energy spectra for both collision periods and compare event rates for images with and without luminosity. We observe a slight increase in the event rate following the Pb-Pb collisions, coinciding with a rise in the single-electron rate, which will be investigated in future work. Using the low-energy proton-proton results, we place 95% confidence level constraints on the mass-millicharge parameter space of millicharged particles. Overall, the results in this work demonstrate the viability of skipper-CCD technology to explore new physics at high-energy colliders and motivate future searches with more massive detectors.

Cervantes-Vergara, Brenda A. [Fermi National Accel↗

Unsupervised anomaly detection in MeV ultrafast electron diffraction

MeV ultrafast electron diffraction (MUED) is a pump-probe technique used to study the dynamic structural evolution of materials. An ultrashort laser pulse triggers structural changes, which are then probed by an ultrashort relativistic electron beam. To overcome low signal-to-noise ratios, diffraction patterns are averaged over thousands of shots. However, shot-to-shot instabilities in the electron beam can distort individual patterns, introducing uncertainty. Improving MUED accuracy requires detecting and removing these anomalous patterns from large datasets. In this work, we developed a fully unsupervised methodology for the detection of anomalous diffraction patterns. Using a convolutional autoencoder, we calculate the reconstruction mean squared error of the diffraction patterns. Based on the statistical analysis of this error, we provide the user an estimation of the probability that the pattern is normal, which also allows a posterior visual inspection of the images that are difficult to classify. This method has been trained with only 100 diffraction patterns and tested on 1521 patterns, resulting in a false positive rate between 0.2% and 0.4%, with a training time of 10 s per image and a test time of about 1 s per image. Here, the proposed methodology can also be applied to other diffraction techniques in which large datasets are collected that include faulty images due to instrumental instabilities.

43 PARTICLE ACCELERATORS↗

The Present and Future of QCD: QCD Town Meeting White Paper – An Input to the 2023 NSAC Long Range Plan

It is currently understood that there are four fundamental forces in nature: gravitational, electromagnetic, weak and strong forces. The strong force governs the interactions between quarks and gluons, elementary particles whose interactions give rise to the vast majority of visible mass in the universe. The mathematical description of the strong force is provided by the non-Abelian gauge theory Quantum Chromodynamics (QCD). While QCD is an exquisite theory, constructing the nucleons and nuclei from quarks, and furthermore explaining the behavior of quarks and gluons at all energies, remain to be complex and challenging problems. Such challenges, along with the desire to understand all visible matter at the most fundamental level, position the study of QCD as a central thrust of research in nuclear science. Experimental insight into the strong force can be gained using large particle accelerator facilities, which are necessary to probe the very short distance scales over which quarks and gluons interact. The Long Range Plans (LRPs) exercise of 1989 and 1996 led directly to the construction of two world-class facilities: the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab (JLab) that is focused on studying how the structure of hadrons emerges from QCD (cold QCD research), and the Relativistic Heavy Ion Collider (RHIC) at Brookhaven National Lab (BNL) that aims at the discovery and study of a new state of matter, the quark-gluon plasma (QGP), at extremely high temperatures (hot QCD research). These past investments have produced major advances. Nucleons and nuclei are being studied with increasing precision with a unified description of the partonic structure utilizing multi-dimensional imaging. Significant progress has been made, paving the way towards a complete picture of how quarks and gluons give rise to the mass, spin, and momentum of the nucleon. In hot QCD, the QGP is created in the collisions of nuclei at RHIC and the Large Hadron Collider (LHC) and is observed to behave like a fluid with very low specific shear viscosity; the current goals are to understand how the fluid behavior emerges from QCD and to characterize the temperature (and chemical potential) dependence of the properties of the QGP. As this White Paper is written, current experimental programs at CEBAF, RHIC and the LHC continue to provide exciting near term opportunities to capitalize on the investments in experimental equipment and accelerator operations. Most importantly, the QCD community looks forward to the construction of the Electron Ion Collider (EIC) as a major new facility to push forward QCD research in the next decades, with significant focus on exploring the properties of gluons, the mediators of the strong force.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Production and Purification of Terbium-155 Using Natural Gadolinium Targets

Terbium-155 (t 1/2 = 5.32 days) is one of four medically relevant radioisotopes of terbium. It is of interest to the field as a suitable diagnostic counterpart for therapeutic radiolanthanides, as its decay scheme includes γ-rays that are suitable for single photon emission computed tomography (SPECT) imaging. Additionally, 155 Tb has an Auger electron (AE) yield that is viable for AE therapy. There are several direct and indirect production routes that can produce 155 Tb. Two possible direct routes include proton irradiation on gadolinium targets via 155 Gd(p,n) 155 Tb and 156 Gd(p,2n) 155 Tb. The 155 Gd(p,n) 155 Tb reaction is accessible at incident proton beam energies of ∼10 MeV, whereas the 156 Gd(p,2n) 155 Tb nuclear reaction requires ∼18 MeV. This study aims to investigate the production of 155 Tb from natGd through the nat Gd(p,x) nuclear reaction, wherein both (p,n) and (p,2n) reactions were leveraged, and the purification using a three-column ion chromatography method. Using this system, recoveries of radioterbium of up to 97% were achieved in addition to high recoveries of the Gd target material, illustrating the suitability of this technique for enriched targets.

36 MATERIALS SCIENCE↗