Search NASA⌕ Search

SEARCH · Search NASA

Results for “electronics packaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Apparatus and method of direct water cooling several parallel circuit cards each containing several chip packages

A cooling apparatus, system and like method for an electronic device includes a plurality of heat producing electronic devices affixed to a wiring substrate. A plurality of heat transfer assemblies each include heat spreaders and thermally communicate with the heat producing electronic devices for transferring heat from the heat producing electronic devices to the heat transfer assemblies. The plurality of heat producing electronic devices and respective heat transfer assemblies are positioned on the wiring substrate having the regions overlapping. A heat conduit thermally communicates with the heat transfer assemblies. The heat conduit circulates thermally conductive fluid therethrough in a closed loop for transferring heat to the fluid from the heat transfer assemblies via the heat spreader. A thermally conductive support structure supports the heat conduit and thermally communicates with the heat transfer assemblies via the heat spreader transferring heat to the fluid of the heat conduit from the support structure.

42 ENGINEERING↗

Standards for PV Modules and Components -- Recent Developments and Challenges: Preprint

International standards play an important role in the Photovoltaic industry. Since PV is such a global industry it is critical that PV products be measured and qualified the same way everywhere in the world. IEC TC82 has developed and published a number of module and component measurement and qualification standards. These are continually being updated to take advantage of new techniques and equipment as well as better understanding of test requirements. Standards presently being updated include the third edition of IEC 61215, Crystalline Silicon Qualification and the second edition of IEC 61730, PV Module Safety Requirements. New standards under development include qualification of junction boxes, connectors, PV cables, and module integrated electronics as well as for testing the packaging used during transport of modules. After many years of effort, a draft standard on Module Energy Rating should be circulated for review soon. New activities have been undertaken to develop standards for the materials within a module and to develop tests that evaluate modules for wear-out in the field (International PV Module QA Task Force). This paper will discuss these efforts and indicate how the audience can participate in development of international standards.

14 SOLAR ENERGY↗

Determination of structure parameters in strong-field tunneling ionization theory of molecules

In the strong field molecular tunneling ionization theory of Tong et al. [Phys. Rev. A 66, 033402 (2002)], the ionization rate depends on the asymptotic wave function of the molecular orbital from which the electron is removed. The orbital wave functions obtained from standard quantum chemistry packages in general are not good enough in the asymptotic region. Here we construct a one-electron model potential for several linear molecules using density functional theory. We show that the asymptotic wave function can be improved with an iteration method and after one iteration accurate asymptotic wave functions and structure parameters are determined. With the new parameters we examine the alignment-dependent tunneling ionization probabilities for several molecules and compare with other calculations and with recent measurements, including ionization from inner molecular orbitals.

74 ATOMIC AND MOLECULAR PHYSICS↗

SU-E-T-164: Evaluation of Electron Dose Distribution Using Two Algorithms

Purpose: To appreciate the difference of electron dose distributions calculated from the Monte Carlo and Electron 3D algorithms of radiotherapy in a heterogeneous phantom. Methods: A phantom consisted of two different materials (lungs mimicked by low-density cork and others by polystyrene) with an 11x16 cm field size (SSD = 100 cm) was utilized to estimate the two-dimensional dose distributions under 6 and 18 MeV beams. On behalf of two different types of tissue, the heterogeneous phantom was comprised of 3 identical slabs in the longitudinal direction with a thickness of 1 cm for each slab and 2 with a thickness of 2.5 cm. The Monte Carlo/MCTP application package constituted of five codes was performed to simulate the electron beams of a Varian Clinac 23IX. A 20x20 cm2 type III (open walled) applicator was used in these simulations. It has been shown elsewhere that the agreement of the phase space data between the calculation results of MCTP application package and the measured data were within 2% on depth-dose and transverse profiles, as well as output factor calculations. The electron 3D algorithm owned by Pinnacle 8.0m and the MCTP application package were applied for the two-dimensional dose distributions calculation. The curves at 50% and 100%-prescribed dose were observed for 6 and 18 MeV beams, respectively. Results: The MC calculations results were compared with the electron 3D calculations in terms of two-dimensional dose distributions for 6 and 18 MeV beams showed excellent agreement except in distal boundary where it was the very junction of the high and low-density region. Conclusions: The Monte Carlo/MCTP method could be used to better reflect the dose variation caused by heterogeneous tissues. Conclusion: A case study showed that the Monte Carlo/MCTP method could be used to better reflect the dose variation caused by heterogeneous tissues.

60 APPLIED LIFE SCIENCES↗

Preparation and Determination of Antimicrobial Property of Cation-Exchanged Ecuadorian Natural Zeolite to be Used as Filler for Polyethylene and Polypropylene Matrices

Zeolites are crystalline aluminosilicates with nanoporous structure, tasteless and non-toxic materials. In this study, silver ion-exchanged zeolite, which was prepared from the natural Ecuadorian zeolites was used as reinforcement material in low-density polyethylene (LDPE) and polypropylene (PP). Polymers were filled with 1, 2 and 3 wt% concentrations of natural zeolite (Z) and silver ion exchanged zeolite (ZA). Zeolites and composites were characterized by X-ray diffractometry, Fourier transform infrared spectroscopy, scanning electron microscope, thermogravimetric analysis and mechanical analysis techniques. Microbiological analysis of silver ion exchanged zeolite showed effective antibacterial property against Escherichia coli bacteria. PP/ZA composites showed better tensile strengths in all mixes comparing to pure PP. ZAPE2 and ZAPP1 showed the best mechanical properties among all the composites based on polyethylene and PP, respectively. The composites prepared are potential candidates to be used in food packaging, and ZA type zeolites can be used as filler for the preparation of various composites.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Skopi: a simulation package for diffractive imaging of noncrystalline biomolecules

X-ray free-electron lasers (XFELs) have the ability to produce ultra-bright femtosecond X-ray pulses for coherent diffraction imaging of biomolecules. While the development of methods and algorithms for macromolecular crystallography is now mature, XFEL experiments involving aerosolized or solvated biomolecular samples offer new challenges in terms of both experimental design and data processing. Skopi is a simulation package that can generate single-hit diffraction images for reconstruction algorithms, multi-hit diffraction images of aggregated particles for training machine learning classifiers using labeled data, diffraction images of randomly distributed particles for fluctuation X-ray scattering algorithms, and diffraction images of reference and target particles for holographic reconstruction algorithms. Skopi is a resource to aid feasibility studies and advance the development of algorithms for noncrystalline experiments at XFEL facilities.

59 BASIC BIOLOGICAL SCIENCES↗

DMFTwDFT: An open-source code combining Dynamical Mean Field Theory with various density functional theory packages

We report Dynamical Mean Field Theory (DMFT) is a successful method to compute the electronic structure of strongly correlated materials, especially when it is combined with density functional theory (DFT). Here, we present an open-source computational package (and a library) combining DMFT with various DFT codes interfaced through the Wannier90 package. The correlated subspace is expanded as a linear combination of Wannier functions introduced in the DMFT approach as local orbitals. In particular, we provide a library mode for computing the DMFT density matrix. This library can be linked and then internally called from any DFT package, assuming that a set of localized orbitals can be generated in the correlated subspace. The existence of this library allows developers of other DFT codes to interface with our package and achieve the charge-self-consistency within DFT+DMFT loops. To test and check our implementation, we computed the density of states and the band structure of well-known solid-state correlated materials, namely LaNiO, SrVO, and NiO. The obtained results are compared to those obtained from other DFT+DMFT implementations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Genome packaging in EL and Lin68, two giant phiKZ-like bacteriophages of P. aeruginosa

A unique feature of the Pseudomonas aeruginosa giant phage phiKZ is its way of genome packaging onto a spool-like protein structure, the inner body. Until recently, no similar structures have been detected in other phages. We have studied DNA packaging in P. aeruginosa phages EL and Lin68 using cryo-electron microscopy and revealed the presence of inner bodies. The shape and positioning of the inner body and the density of the DNA packaging in EL are different from those found in phiKZ and Lin68. This internal organization explains how the shorter EL genome is packed into a large EL capsid, which has the same external dimensions as the capsids of phiKZ and Lin68. The similarity in the structural organization in EL and other phiKZ-like phages indicates that EL is phylogenetically related to other phiKZ-like phages, and, despite the lack of detectable DNA homology, EL, phiKZ, and Lin68 descend from a common ancestor. - Highlights: • We performed a comparative structural study of giant P. aeruginosa phages: EL, Lin68 and phiKZ. • We revealed that the inner body is a common feature in giant phages. • The phage genome size correlates with the overall dimensions of the inner body.

60 APPLIED LIFE SCIENCES↗

Coupling High-Energy Radiography And Photon Activation Analysis (PAA) To Optimize The Characterization Of Nuclear Waste Packages

Radiological characterization of nuclear waste packages is an industrial issue in order to select the best mode of storage. The alpha-activity, mainly due to the presence of actinides ({sup 235}U, {sup 238}U, {sup 239}Pu,...) inside the package, is one of the most important parameter to assess during the characterization. Photon Activation Analysis (PAA) is a non-destructive active method (NDA method) based on the photofission process and on the detection of delayed particles (neutrons and gammas). This technique is well-adapted to the characterization of large concrete waste packages. However, PAA methods often require a simulation step which is necessary to analyze experimental results and to quantify the global mass of actinides. The weak point of this approach is that characteristics of the package are often not well-known, these latter having a huge impact on the final simulation result. High-energy radiography, based on the use of a linear electron accelerator (LINAC), allows to visualize the content of the package and is also a performing way to tune simulation models and to optimize the characterization process by PAA. In this article, we present high-energy radiography results obtained for two different large concrete waste packages in the SAPHIR facility (Active Photon and Irradiation System). This facility is dedicated to PAA study and development and setup for a decade in CEA Saclay. We also discuss possibilities offered by the coupling between high-energy radiography and PAA techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Impact of Accelerated Stress-Tests on SiC MOSFET Precursor Parameters

Integrating SiC power MOSFETs is very attractive for advancing power electronic system performance, yet the system reliability with new devices remains in question. This work presents an overview of accelerated lifetime tests and the packaging and semiconductor failure mechanisms they excite. The experiments explained here includes High Temperature Gate Bias (HTGB), Switching Cycling, Power Cycling, and Thermal Cycling. These experiments stress different failure mechanisms, that show degradation in different device parameters including, but not limited to, threshold voltage and on-resistance. These four experiments help illustrate the spectrum between device and package degradation that can be used to design more reliable power electronic circuits.

33 ADVANCED PROPULSION SYSTEMS↗

Impact of Accelerated StressTests on SiC MOSFET Precursor Parameters: Preprint

Incorporating SiC power MOSFETs is very attractive for advancing power electronic system performance, yet the system reliability with new devices remains in question. This work presents an overview of accelerated lifetime tests and the packaging and semiconductor failure mechanisms they excite. The experiments explained here includes High Temperature Gate Bias (HTGB), Switching Cycling, Power Cycling, and Thermal Cycling. These experiments stress different failure mechanisms, that show degradation in different device parameters including, but not limited to, threshold voltage and on-resistance. These four experiments help illustrate the spectrum between device and package degradation that can be used to design more reliable power electronic circuits.

33 ADVANCED PROPULSION SYSTEMS↗

Automated Energy-Dispersive X-ray Spectroscopy Analysis for Multi-Modal Few-Shot Learning

Scanning transmission electron microscopy (STEM) is a powerful tool that allows for the atomic-scale analysis of a materials’ structure, chemistry, and defect domains (Akers et al. 2021). The current generation of microscopes generate vast amounts of data, surpassing the limits of effective manual analysis traditionally performed by domain experts (Spurgeon et al. 2021). While recent strides in machine learning have significantly enhanced the processing of large and intricate datasets acquired through electron microscopy, the prevalent use of proprietary software packages for initial data collection poses a challenge. In many cases, these software packages act as a ‘black box’, constraining user functionality and hindering the output of data in a format that is conducive to seamless integration into machine learning models. This work addresses these challenges by adapting HyperSpy, an open-source Python library, for the analysis and quantification of raw energy dispersive spectroscopy (EDS) data acquired through STEM. The modified HyperSpy code successfully facilitates user-defined segmentation of the data, enabling the integration of atomic %, weight %, and raw EDS spectra for each segmented region into an existing few-shot machine learning model. While initial results reveal discrepancies in quantified atomic and weight percentages when compared to proprietary software, ongoing efforts aim to rectify this issue by refining the fit of the HyperSpy model to the EDS spectra. Overall, this research underscores the potential of open-source tools like HyperSpy to enhance the accessibility of analytical tools, fostering a transparent and user-friendly environment for seamlessly incorporating electron microscopy data into machine learning models.

36 MATERIALS SCIENCE↗

Integrated three-dimensional module heat exchanger for power electronics cooling

Embodiments discussed herein are directed to a power semiconductor packaging that removes heat from a semiconductor package through one or more cooling zones that are located in a laterally oriented position with respect to the semiconductor package. Additional embodiments are directed to circuit elements that are constructed from one or more modular power semiconductor packages.

42 ENGINEERING↗

Construction of meta-GGA functionals through restoration of exact constraint adherence to regularized SCAN functionals

The strongly constrained and appropriately normed (SCAN) meta-GGA exchange–correlation functional is constructed as a chemical environment-determined interpolation between two separate energy densities: one describes single-orbital electron densities accurately and another describes slowly varying densities accurately. To conserve constraints known for the exact exchange–correlation functional, the derivatives of this interpolation vanish in the slowly varying limit. While theoretically convenient, this choice introduces numerical challenges that degrade the functional’s efficiency. We have recently reported a modification to the SCAN meta-GGA, termed restored-regularized-SCAN (r 2 SCAN) , that introduces two regularizations into SCAN, which improve its numerical performance at the expense of not recovering the fourth order term of the slowly varying density gradient expansion for exchange. Here, we show the derivation of a progression of density functional approximations [regularized SCAN (rSCAN), r++SCAN, r 2 SCAN, and r 4 SCAN] with increasing adherence to exact conditions while maintaining a smooth interpolation. The greater smoothness of r 2 SCAN seems to lead to better general accuracy than the additional exact constraint of SCAN or r 4 SCAN does.

, correlation energy↗

Organic Direct-Bonded-Copper-Based Rapid Prototyping for Silicon Carbide Power Module Packaging

Silicon carbide (SiC) power devices are playing ever- growing roles in high-power-density power electronics converters by offering benefits such as high voltage rating, fast transients, and high thermal performance. Organic direct-bonded copper (ODBC)-based packaging, due to its ductility and ease of han- dling, allows the possibility of a more flexible layout design that may better tap the potential of SiC benefits. In this work, an ODBC-based prototyping routine is developed that accelerates the iterations of packaging layout design with low cost. The properties of ODBC and its handling are briefly introduced, and tools and fabrication steps are explained. Following this routine, a 1.2-kV SiC half-bridge power module is designed and fabricated with the focus on sub-nanohenry ultra-low loop inductance. Simulation and experimental validation are also conducted.

25 ENERGY STORAGE↗

Successful Implementation of Image-Guided Radiation Therapy Quality Assurance in the Trans Tasman Radiation Oncology Group 08.01 PROFIT Study

Purpose: The quality assurance (QA) of image-guided radiation therapy (IGRT) within clinical trials is in its infancy, but its importance will continue to grow as IGRT becomes the standard of care. The purpose of this study was to demonstrate the feasibility of IGRT QA as part of the credentialing process for a clinical trial. Methods and Materials: As part of the accreditation process for a randomized trial in prostate cancer hypofraction, IGRT benchmarking across multiple sites was incorporated. Each participating site underwent IGRT credentialing via a site visit. In all centers, intraprostatic fiducials were used. A real-time assessment of analysis of IGRT was performed using Varian's Offline Review image analysis package. Two-dimensional (2D) kV and MV electronic portal imaging prostate patient datasets were used, consisting of 39 treatment verification images for 2D/2D comparison with the digitally reconstructed radiograph derived from the planning scan. The influence of differing sites, image modality, and observer experience on IGRT was then assessed. Results: Statistical analysis of the mean mismatch errors showed that IGRT analysis was performed uniformly regardless of institution, therapist seniority, or imaging modality across the three orthogonal planes. Conclusions: The IGRT component of clinical trials that include sophisticated planning and treatment protocols must undergo stringent QA. The IGRT technique of intraprostatic fiducials has been shown in the context of this trial to be undertaken in a uniform manner across Australia. Extending this concept to many sites with different equipment and IGRT experience will require a robust remote credentialing process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗