DS-TIDE: Harnessing Dynamical Systems for Efficient Time-Independent Differential Equation Solving

Time-Independent Differential Equations (TIDEs) are central to modeling equilibrium behavior across a wide range of scientific and engineering domains, from electrostatics to porous media flow. Conventional numerical solvers offer reliable solutions but incur significant computational costs due to fine-grained discretization and iterative procedures. Machine learning-based approaches address this by replacing iterative solving processes with one-time inference; however, their sophisticated models require extensive training resources that often exceed those of traditional solvers. Consequently, designing a TIDE solver that achieves high accuracy, broad applicability, and exceptional computational efficiency remains a fundamental challenge. In this paper, we propose DS-TIDE, a novel hardware solver that is inspired by, and subsequently leverages, the intrinsic connection between Dynamical Systems (DS) and Differential Equations (DEs) to efficiently and accurately solve TIDEs. DS-TIDE employs a CMOS-compatible DS-based processor, whose physical states evolve under carefully designed DE-driven dynamics and naturally converge to equilibrium -- the solution of the target TIDE -- within ~1µs on a ~1-watt DS-TIDE processor. To enhance expressivity, DS-TIDE incorporates Heterogeneous Dynamics with Temporal Layering (HDTL), which solves TIDEs through a three-stage DS evolution -- conditioning, solving, and decoding -- each governed by specialized dynamics. The entire evolution process is analogous to an infinitely deep neural network temporally unrolled, offering the system the capability of representing complex equations. Furthermore, DS-TIDE is equipped with an on-device DS-DE Auto-Alignment mechanism that dynamically adapts intrinsic hardware dynamics within milliseconds, effectively aligning the system’s dynamics to diverse target DEs. Experimental results across TIDEs from a wide range of scientific and engineering domains demonstrate that DS-TIDE achieves ~10^3× speedup, ~10^5× energy savings, and competitive or superior accuracy compared to state-of-the-art numerical and ML-based solvers.

Liu, Chuan↗

Characterizing Variability in Lignocellulosic Biomass: A Review

Feedstock variability is a significant barrier to the scale-up and commercialization of lignocellulosic biofuel technologies. Variability in feedstock characteristics and behavior creates numerous challenges to the biorefining industry by affecting continuous operation and biofuels yields. Recently, feedstock variability is understood and explained largely on the basis of chemical composition. Physical and mechanical properties and behavior of lignocellulosic feedstock in various unit operations, studied through advanced analytical methods, can further explain variability. Such studies will enable us in developing processes and designing equipment to improve operation and conversion performance. In this perspective, we review several advanced analytical methods that measure density, moisture content, thermal properties, flowability, grindability, rheology properties, and micromorphological characteristics. We also discuss the correlations and interactions among these properties that reflect the complexity of lignocellulosic biomass as a feedstock and the associated quality metrics and logistics of supplying consistent quality feedstock to a biorefinery. We further examine methods that have not traditionally been used to characterize lignocellulosic feedstocks but have the potential to bridge the gap in our explanation of feedstock variability.

09 BIOMASS FUELS↗

Radiation portal monitor data file format for comprehensive background radiation monitoring

Radiation portal monitors (RPMs) are widely used at border security checkpoints to detect the presence of radioactive materials in people, vehicles, and cargo. Typically, RPM detection systems consist of two pillars equipped with gamma and neutron detectors. To improve detection efficiency, RPMs employ techniques such as a limited energy window, dynamic alarm thresholds, and lead shielding. However, without continuous monitoring of background radiation, signal interpretation can be compromised, because environmental factors and mechanical failures can cause fluctuations. Here, we introduce a daily file format that logs gamma background and neutron background radiation levels continuously over a 24 h period; this format is different from traditional formats that record data only when the RPM is active or occupied. The approach enables RPM operators and analysts to (1) identify and diagnose malfunctioning components, (2) adjust system settings to account for dynamic environmental factors, and (3) use the recorded data to characterize outer space phenomena. Continuous background reporting is essential for identifying issues such as faulty connections, voltage divider failures, and errors in background updates. Continuous background reporting also enables the detection of external influences, including nearby X-ray scanners, temperature fluctuations, rainfall, cosmic radiation, and lunar phase changes. These data files are designed to be easily evaluated and parsed using common tools, and a quick review by an expert is often sufficient for problem diagnosis. We anticipate that continuous background radiation monitoring and these new strategies will significantly improve the accuracy and reliability of RPM systems, reducing the rate of false alarms and enhancing overall system performance.

Background radiation monitoring↗

Clean Condensing Gas Furnace

Natural gas furnaces are the most common space heating equipment in the U.S. residential and commercial building markets. However, current residential natural gas condensing furnaces generate substantial acidic condensate as well as significant emissions of sulfur oxides (SOx), nitrogen oxides (NOx), carbon monoxide (CO), hydrocarbons (HC), and methane (CH 4 ) contributing to environmental degradation of air, water, and soil. This report describes a novel solution to reduce the environmental impact of natural gas condensing furnaces based on the technology of a monolithic acidic gas reduction (AGR) catalyst for SOx trapping, NOx redox to nitrogen, and oxidation of formic acid, CO, HC, and CH 4 . The AGR technology offers the following benefits: (1) a neutral furnace condensate with a pH of ~7, allowing its safe release into the sewer system thus eliminating a second drainage system; (2) trapping and removing nearly all SOx emissions; (3) NOx emissions nearly at nearly 1-2 ng/J, more than 95% lower than new emissions standards in California; (4) the use of a low-cost heat exchanger as a condensing heat exchanger (HX) since the condensate is not acidic, avoiding the need for expensive stainless steel alloys; and (5) unburnt fuel energy recovery to boost efficiency.The AGR component and AGR-enabled furnace performance were broadly tested to determine their effects on long-term reliability and durability, as well as SOx storage and regeneration activity. The AGR regeneration does not impair the performance in achieving neutral condensate and ultra-low NOx emissions, and the AGR catalyst subjected to regeneration activities continued to function well and achieved slightly better annual fuel utilization efficiency (AFUE). The 400-hour reliability and durability test of the retrofitted condensing furnace with the AGR component shows that the furnace unit still achieves a neutral furnace condensate with a pH of ~7 and enables 0~3 ng/J of NOx emissions. However, the 400-hour operation slightly degraded the AFUE because of soot particle accumulation caused by frequent incomplete combustion owing to inappropriate condensate drainage during testing. Thus, proper condensate drainage is critical for AGR-enabled furnaces. Furthermore, neutron computed tomography was employed to survey the aged AGR component and demonstrate high-resolution 2D and 3D representations for the nondestructive diagnosis of the AGR component. The tomography showed that the AGR component did not deform or suffer broken AGR channels. A new AGR catalyst with low precious metal loading was preliminarily explored to identify a pathway of optimizing AGR material loading and maximizing acidic gas reduction at low cost. The new AGR component can reduce precious metal loading by 38% and still achieve neutral condensate and ultralow NOx emissions. The furnace with the AGR component of low Pt/Rh loading enables a maximum AFUE of 97%, which is meaningfully higher than the original furnace. Long-duration testing for the furnace enabled with the low precious metal loading AGR component will be vital in future research. Although the current work demonstrates a proof of concept for the AGR-enabled furnace, the AGR assembly needs to be optimized and integrated into the design of new OEM furnace products. Furthermore, the AGR technology can be applied not only for residential gas furnaces, but also for commercial rooftop units, gas heat pumps, gas-fired water heaters, combustion boilers, and other systems.

03 NATURAL GAS↗

OLCF Summit Supercomputer GPU Snapshots During Double-Bit Errors and Normal Operations

As we move into the exascale era, the power and energy footprints of high-performance computing (HPC) systems have grown significantly larger. Due to the harsh power and thermal conditions the system, components are exposed to extreme operating conditions. Operation of such modern HPC systems requires deep insights into long term system behavior to maintain its efficiency as well as its longevity. To help the HPC community to gain such insights, we provide double-bit errors using system telemetry data and logs collected from the Summit supercomputer, equipped with 27,648 Tesla V100 GPUs with 2nd-generation high-bandwidth memory (HBM2). The dataset relies on Nvidia XID records internally collected by GPU firmware at the time of failure occurrence, on the reboot-time logs of each Summit node, on node-level job scheduler records collected after each job termination, and on a 1Hz data rate from the baseboard management controllers (BMCs) of each Summit compute node using the OpenBMC event subscription protocol. Technical details can be found in the paper Oles et. al “Understanding GPU Memory Corruption at Extreme Scale: The Summit Case Study” ICS’24 (https://doi.org/10.1145/3650200.3656615).

97 MATHEMATICS AND COMPUTING↗

Power System Resilience Metrics Augmentation for Critical Load Prioritization

One of the major goals of new grid operation regimes, such as transactive energy systems (TESs), is to make the power grid more resilient to withstand natural or man-made disasters and potential reliability events, and to continue to serve the maximum number of its customers. But it is a well-known fact to system operators that not all customers are the same. This implies that any discussion of TESs’ impacts on the resilience of the power system should consider the needs of its critical customers (such as the power system operation centers, fire and police stations, and hospitals) over those of other customers. When evaluating the resilience of the system, bonus points must be awarded to any system that could maintain its power supply to critical customers during a disturbance that may cause an outage. This report discusses critical infrastructure (CI) as found in the literature and then categorizes it based on the field to which the operations belong (such as human life/safety-related, operations management, necessary city operation, industrial customers, etc.). Each of these CI categories is further divided into types of critical customers (e.g., the human life/safety-related category has different types of customers like hospitals, fire and police stations, etc.). The entire demand of each of the critical customer types is not categorized as critical load (CL); instead, only a portion of the total load of these critical customers is characterized as critical load. This is done based on the categories of equipment, the function of which is crucial in the operation of the overall facility. CL categorization is performed to provide the ratio of the critical load portion to the overall load , so that it can serve as a parameter in the resilience evaluation of the grid through a metrics-based approach. Such categorization is important as it helps to augment the existing quantifiable resilience metrics with CL categorization. The metrics for a power system need to not only consider how well a system performed during a disturbance event, but also how it reduced strain and supplied power to its CLs. The first step in this process is characterize CLs in the system. After CL characterization, the next step is the inclusion of these loads in the resilience metrics. To that end, in this report weight-based augmentation of resilience metrics is proposed, where certain customers (the ones that are categorized as critical) are assigned higher weights than others. Though an overview of assigning weights to customers is discussed, there is no one-size-fits-all approach for every power system. The decisions made about assigning such weights to customers vary greatly from one operator to another, based on their unique systems and the current and predicted states of critical customers. This decision-making can include the type of disturbance event, which might only affect certain parts of the system. In general, analyzing critical customers before an event helps understand system vulnerabilities. It also helps in planning and conducting operations during the event, evaluating system performance after the event, and supporting better planning for future events. An alternative to the current practices of managing the grid for outages is an innovative TES, which has the potential to provide a platform for including distributed energy resources for managing CLs. This report also describes how TES qualities can help (1) to maintain power supply to critical customers for uninterrupted operations and (2) to restore lost power supply to the critical customers rapidly.

24 POWER TRANSMISSION AND DISTRIBUTION↗

From Obsolete to Optimal (ATR Demineralized Water System)

My project was migrating a Human-Machine Interface (HMI) and Programmable Logic Controller (PLC) program from legacy software to a modern platform, enhancing operational efficiency and eliminating unsupported, obsolete equipment. Initially, I used a migration tool to transfer the programs to the new software, then manually updated variables to align with the new PLC. I optimized the PLC code by leveraging new scaling features in the I/O cards, removing over 45 obsolete rungs, and enhancing clarity with functional tag aliases. Next, I modernized the HMI's visuals with an updated color scheme and 3D buttons. I developed multiple interface versions iteratively refining them based on operator feedback. I also designed and created a dedicated "Rounds" screen incorporating insights from a previous intern’s project to streamline daily rounds. To improve clarity, consistency, and efficiency I redesigned the entire interface. Adding visual indicators to enhance operational awareness: red is used for values outside normal specifications, green for normal operating modes, yellow for manual mode, and grey for offline units. Additionally, I added a dynamic visual representation of tank levels, creating PLC logic to show the level in inches as well as inches and feet. I then incorporated a navigation sidebar to facilitate efficient screen transitions. Risk of human error was mitigated by defining narrow input ranges for tank level shutoff and password protecting setpoint changes. I also fixed issues with datatypes that caused inaccuracies in the original code. Overall, this comprehensive upgrade significantly enhanced the HMI's functionality, user experience, and operational reliability.

47 - OTHER INSTRUMENTATION↗

Evaluating the Effectiveness of an Ultrasonic Acoustic Deterrent in Reducing Bat Fatalities at Wind Energy Facilities

This project was designed to use thermal video cameras and fatality monitoring to evaluate the effectiveness of an ultrasonic acoustic deterrent (UAD) on bat activity and mortality, respectively. Our goals were to redesign the UAD device and installation infrastructure, determine the placement on wind turbines to optimize safety, compatibility and functionality, and to compare the mortality among the following conditions: Control (deterrents off and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Deterrent (deterrents on and turbines feathered up to the manufacturer’s cut-in speed of 3.5 m/s), Curtailment (deterrents off and turbines feathered up to 5/ m/s), and combination (deterrents on and turbines feathered up to 5 m/s). The project was divided into a Feasibility Study and Comparative Study. The objectives for the Feasibility Study were to develop an installation strategy, redesign a previous iteration of a UAD to improve performance and weatherization, and test the effectiveness of the deterrents on bat activity. The Feasibility Study was intended to work out potential issues using a relatively small number of devices prior to manufacturing and installing numerous devices for a larger-scale comparative study. The division of the project into these separate studies was based on previous experience and the challenges of assessing the capabilities of an untested UAD. During the initial development and manufacturing of the UAD, NRG Systems decided to use a piezoelectric transducer rather than an electrostatic transducer, which was used by a previous device (i.e. Deaton UAD). NRG Systems conducted lab testing (i.e., IP67 or Ingress Protection) to ensure no water or dust ingress. In addition, shock/drop trials and variations in temperature exposure were conducted as part of the reliability testing. NRG Systems also developed a communications system to allow for continuous performance monitoring of the UADs. For the Feasibility Study, we installed 6 UADs on each of 2 Gamesa G90 2-MW wind turbines (Turbine 14 and 8) at the South Chestnut Wind Energy Facility, Pennsylvania and monitored activity under control and treatment (i.e. Deterrent) conditions using thermal video monitoring. There are two major sources of variation in bat activity (beyond the anticipated treatment effect): 1) environment around the turbines might inherently favor more activity at one than the other; 2) weather conditions on any given night or within season difference (e.g., migration later during the study period) might favor more activity on some nights than on other nights. Because we could only monitor two turbines on any night, we sought to control the potential influences of these two sources by alternating the turbine on which deterrents were activated each night. If there were no loss of data due to technical failures, this design would result in an equal number of deterrent and control nights at each turbine through the monitoring period, balancing the effects of both sources of variation. We compared the time bats spent and the number of events that occurred in overlapping cameras FOV as an indicator of risk, since 80% of the overlapping FOV of the cameras was in the RSA. Equipment failures, majority due to lightning, resulted in only 17 nights with useable data, with unbalanced treatment assignment within turbines and uneven distribution of treatment assignment throughout the observational period. This resulted in a confounding of treatment assignment and seasonal change. Deterrent treatment was measured at Turbine 14 on only 2 of the first 8 usable nights (spanning the period from 8/18-9/17), whereas 6 times on Turbine 8. From 9/18-927, deterrent was on at Turbine 14 on 6 of the remaining 10 nights, and 4 on Turbine 8. We recorded a total of 1,057 bats and observed a reduction in number of events and duration of events at the UAD-activated turbine when it was Turbine 14. When Turbine 8 had the UAD activated, we observed no difference in number or duration of events. Variation between turbines is not unusual and can cause issues when study designs have no true replication, i.e., multiple turbines per treatment. Within-turbine differences suggested a trend for reduced activity when UADs were activated, particularly for Turbine 14. These results may be caused by the overall higher bat activity at Turbine 8 and confounding of treatment assignment and seasonal trends. We mapped 58 bat events in 3-dimensional space (3D), 30 and 28 events during control and treatment conditions, respectively. We observed bats crossing the rotor plane under both control and treatment conditions and observed a total of 40 confirmed or near-collisions (i.e., target close to blade but no visual confirmation of a strike) out of a total of 1,491 medium and high confidence bat observations (880 control, 611 at treatment). Twice as many collisions/possible collisions were observed during control conditions. Given the challenges with the equipment and potential confounding of the data (i.e., different activity levels at the two wind turbines), we were unable to determine whether this initial turbine placement and orientation was optimal. Given no new information on how best to install the devices, we elected to use the same placement and orientation for the comparative study. For the Comparative Study, the objectives were to investigate the relative mortality rates among 4 treatments. We searched the area within 90 m of each turbine daily to recover the highest number of fresh fatalities possible. We were unable to detect a clear reduction in mortality from deterrents alone for any individual species. Surprisingly, mortality rate of the eastern red bat (Lasiurus borealis) was estimated to be 1.3–4.2 times as much when turbines were operating normally and UADs were on than when UADs were off. Reduction in mortality of all bat species combined due to curtailment of turbines was estimated to be between 0%–38%. This effect was nullified when, in addition to curtailment, UADs were on, with 95% confidence interval ranging from a 45% reduction to a 36% increase in mortality. This was likely due to the large proportion of eastern red bats in the total carcass population. Mortality of all low-frequency echolocating bats combined (i.e. hoary bat [L. cinereus], big brown bat [Eptesicus fuscus], silver-haired bat [Lasionycteris noctivagans]) relative to control was lower when curtailed (95% CI: 0%–74%), but the addition of UADs had no detectable effect (95%CI: 13%–79%). The combined treatment reduced mortality in silver-haired bats relative to control by 11%–99%, compared to curtailment (81% reduction–67% increase) or deterrent (82% reduction–67% increase) alone. Because silver-haired bats comprised a large proportion of low-frequency calling bats found during this study, a similar effect was seen for that group. The higher mortality observed for eastern red bats at UAD compared to control could have been caused by several factors, such as the effective range of the UAD, particularly at higher frequencies, behavior, positioning of the devices on the nacelle, or a combination of these. We used 3D thermal videography to compare control and UAD bat behavior from two turbines using a total of 203 3D bat-tracks across 34 nights. We recorded a similar number of bat-tracks between treatment groups, with 51% and 49% for control and UAD, respectively. Due to potential differences in bat behavior around spinning vs stationary turbine blades, we examined UAD effectiveness separately for non-operating turbines (feathered below cut-in speed of 3.5 m/s) and operating (normal operation above wind speed of 3.5 m/s). We found a higher proportion of bat-tracks at operating turbines (82%) compared to non-operating turbines (18%), although this does not account for overall time turbines were operating versus not. At non-operating turbines the UAD appears to be effective at reducing the amount of time, flight length, and number of passes through the rotor plane, compared to control. In addition, we found bats approached turbines similarly between control and treatment turbines, with 61% of control and 63% of UAD bat-tracks originating leeward of the hub. In contrast, at operating turbines, we saw little change in bat behavior in response to UADs. For example, we found an increase in the average duration of bat-tracks between non-operating and operating turbines for UAD but at control turbines we found average duration decreased once turbines became operational. Both control and UAD had a high proportion of bat-tracks that crossed the rotor plane (i.e., collision risk) originate from the windward side when turbines were operational 65% to 92%, respectively. Given that the UAD devices closest to the blades were orientated parallel to the blades, its possible bats were not exposed to the signal until they were close to the turbine blades, as suggested by the slightly higher mean duration within 5 meters of the blades for UAD turbines. Future research should consider concentrating UAD intensity on the areas of risk (i.e. blades) with enough buffer to allow bats to react to the sound before entering the rotor-swept area (RSA). In addition, investigating the potential of installing UAD units windward of the turbine blades (e.g. a hub-mounted UAD), particularly since even under control conditions, a relatively high proportion (65%) of crosses through the blade plane originated windward. 3D thermal videography provided valuable information on future testing strategies (e.g. device placement, UAD orientation) to improve UAD effectiveness when bats are at risk (i.e., operating wind turbines). Across the entire project we experienced issues with the operation and communication with the UADs. Most of the issues occurred during the Feasibility Study and were resolved prior to the Comparability Study. Additional challenges surfaced during the Comparability Study but were remedied immediately and are thought to have little impact on the results. We had logistical constraints at the project that limited our ability use traditional methods in our camera calibration. Several calibrations showed inaccurate scales, which may have been related to inadequate spatial coverage of “points” in the camera calibration volume. Because we were using actual video recordings of bats at a wind turbine, the behavior of bats could have concentrated “points” in specific areas of the turbine (i.e. leeward of nacelle), and limited “points” in other areas, resulting in camera calibration issues. We have plans to address these inconsistencies and improving the software and related methodologies by early 2020.

17 WIND ENERGY↗

Impact of Thermal Stress on Attachment and Stability of High Temperature Strain Sensors

Static and dynamic strain sensing is required in high-temperature (HT), harsh-environments (HE) for industrial, aerospace, and energy sector applications to ensure equipment and process safety, reduce the cost of operation and maintenance, and increase process efficiency. Challenges that arise in HT HE sensing applications include device mounting, packaging, integrity, and stability to HT HE conditions. In previously reported work, static and dynamic strain surface acoustic wave resonator (SAWR) sensors were fabricated on langasite (LGS) and mounted on Inconel 625 strain beams for wireless testing up to 400°C. In this work, it has been identified that after subjecting the mounted SAWR strain sensor to thermal cycling between 100°C and 425°C, the measured sensitivity to dynamic strain decreased by 73% due to cracking at the adhesive/LGS interface, further deteriorating after additional thermal cycles. Strain modeling of the mounted LGS sensor chip up to 400°C revealed the existence of concentrated strain at the borders of the LGS chip. Microcracks caused by dicing make the chip boarders the most susceptible location for cracks to initiate when the sensor is subjected to thermal stress. In an attempt to mitigate the high strain at the LGS chip borders due to heating, adhesive shaping is proposed in this work. Simulations indicate a strain reduction of 50% at the border is achieved using both circular and triangular adhesive shapes, while also reducing the maximum strain over the entire adhesive/LGS interface by around 30%. Furthermore, the technique is thus promising for improving the integrity, reliability, and stability of static and dynamic strain sensors, particularly while operating under HT HE with several hundreddegree Celsius temperature excursions.

47 OTHER INSTRUMENTATION↗

Seasonal Cost-Benefit Analysis of Automated Distribution Feeder Upgrades with Advanced Mitigation Technologies

The increasing deployment of distributed solar photovoltaics (DPV) to meet clean energy goals can trigger adverse grid operation issues, such as voltage excursions and the violation of thermal loading constraints of the power delivery elements (e.g., lines and transformers) on the evolving electricity infrastructure. Such integration issues would require distribution upgrades with associated costs to mitigate them and to maintain reliable and resilient grid operating conditions. Traditional distribution network upgrade approaches use a specific single snapshot analysis that is overly conservative. This study considers a multi-time point analysis to capture both moderate (probable bounds) and extreme grid operating conditions using time points such as minimum load with minimum photovoltaics (PV), maximum load with maximum PV, maximum load with minimum PV, and minimum load with maximum PV. Further, this study investigates seasonal variation impacts and associated distribution upgrade costs for a spring season case (March, representing a low load and high PV scenario) and a summer case (July, representing a high load and high PV scenario). Such seasonal analysis will allow system operators to characterize upgrade requirements and associated costs across various periods. Because the spatial distribution of DPV can impact upgrade and associated costs, this study investigates three common DPV deployment scenarios - randomly deployed, close to the substation, and far from the substation - at different penetration levels. Apart from spatial distribution impacts, this project evaluates the techno-economic impacts of the nodal photovoltaic penetration factor (NPPF) for generating the various DPV deployment scenarios at increasing penetration levels. This project investigates the impact of varying nodal PV-to-load ratios using conservative and extreme NPPF values of 3 and 10, respectively. This study investigates the deployment of traditional infrastructure upgrade strategies, such as installing new voltage regulating equipment, transformers and lines replacements, and the activation of advanced inverter functionality (e.g., autonomous volt/VAR) in expanding PV hosting capacity. Existing DPV systems are assumed to operate with the legacy unity power factor, and we considered the possibility of retrofitting such systems with the activation of volt/VAR control as integration standards and regulations continue to evolve to allow such functions. The cost-benefit analysis metrics used in study include distribution upgrade costs, average cost per watt of the upgrade cost, average marginal cost per watt of the upgrade cost, and power losses.

14 SOLAR ENERGY↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗

Success Path Method: Introduction to the Success Path Method Software Tool©

As part of its commitment to advancing safety and reliability assessment methodologies, Argonne National Laboratory pioneered the use of an evaluation method called the Success Path Method (SPM) to improve risk management for offshore oil and gas operations. The development of the SPM at Argonne has been driven by the need to improve existing risk assessment methodologies by focusing on the steps necessary for success rather than failure modes alone. This is particularly important for industrial environments like offshore facilities that perform multiple functions under a continuously evolving set of operational conditions – such as water depth and temperature, currents, and weather conditions. In these dynamic environments, the traditional Probabilistic Risk Assessment (PRA) approach is far too complex as it focuses on what can go wrong – which comprises an infinite failure space that must be fully explored and understood. By shifting the focus to a finite space of success paths, the SPM enables operators and decision makers to prioritize a manageable number of steps that must go right to ensure success. Building on its five decades of experience in safety assessments for the nuclear industry, Argonne made major adaptations to existing risk assessment methods utilizing features similar to fault trees that are traditionally used in PRA to map all pathways in which the system can malfunction. In contrast, SPM identifies the components and processes that must function correctly to achieve specific outcomes – such as preventing the uncontrolled release of hydrocarbons during drilling operations. The SPM framework integrates equipment, procedures, software, processes, and human actions to ensure that physical barriers meet critical safety functions in dynamic operational conditions. This approach helps identify failure modes and improve operational risk management by narrowing the focus to key success elements, which in turn reduces uncertainty and helps users understand, manage, and respond to failures.

97 MATHEMATICS AND COMPUTING↗

AI-Enabled Robots for Automated Nondestructive Evaluation and Repair of Power Plant Boilers. Final Report

Boiler failure could cause loss of life and safety issues, cost hundreds of thousands of dollars in equipment repairs, property damage and production losses, and drive up the cost of electric power. Boiler maintenance is challenging and risky for inspectors working on scaffolding in confined hazardous spaces inside of a boiler and sometimes the space is hard to access. The operation is also time-consuming due to the large area of vertical structures for inspection and the tremendous effort needed for scaffolding. Recently, the use of robotics (e.g., drones and crawlers) in power plants for maintenance is growing rapidly. However, the existing robotics solutions show two notable technological gaps: no live repair capability, and no Artificial Intelligence (AI) for smart autonomy. The objective of this project is to develop an integrated autonomous robotic platform that is equipped with compact non-destructive evaluation (NDE) sensors to perform live inspection, operates onboard repair devices to perform live repair, and uses AI for intelligent data fusion and predictive analysis for automated and smart spatiotemporal inspection, analysis and repair of the furnace walls in coal-fired boilers. The approach to achieve the objective includes developing NDE sensors with signal processing techniques, designing and evaluating repair devices for robots based on fusion and solid-state technologies, and an autonomous robotic platform that can attach to and navigate on boiler furnace walls using magnetic drive tracks. The robot is also powered by AI to automate data gathering (e.g., 3D mapping and damage localization) and predictive analysis. This project has advanced the state-of-the-art by providing technological breakthroughs including compact NDE and repair tools for robots, AI capabilities for smart autonomy, and a robotic platform for automated boiler maintenance. This project has great potential to result in significant benefits including limiting or eliminating the need to send operators to assess difficult-to-access or hazardous areas, enabling automated live inspection and repair, avoiding time consuming scaffolding (especially for partial maintenance during unplanned outage), collecting comprehensive and well-organized data smartly, and avoiding or limiting the need for onsite or remote piloting technicians. The impacts can be tremendous in terms of the time and cost savings, reducing the risk for human operators, and increasing boiler reliability, usability, and efficiency. In addition, by developing the new technologies on the autonomous inspection and repair robot, by involving multiple undergraduate and graduate students working together with the faculty members on this project, and by generating knowledge and building up collaborations with industrial partners, this effort will significantly update the education capabilities, support long-term fundamental research, and maintain the leadership of Colorado School of Mines and Michigan State University in energy fields.

20 FOSSIL-FUELED POWER PLANTS↗

Measurement of the U 235 ( n , f ) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons of energy from 1 MeV to 20 MeV

The characterization of fission-driven nuclear systems primarily relies on calculations of neutron-induced chain reactions, and these calculations require evaluated nuclear data as input. Calculation accuracy heavily depends on input nuclear data evaluation accuracy, and thus high precision on the experimental input to the nuclear data evaluation is essential for fundamental quantities like the energy spectrum of neutrons emitted from neutron-induced fission (i.e., the prompt fission neutron spectrum, PFNS). Despite decades of measurement efforts, prior to the measurements described in this work there were only three literature data sets for the 235 U(n,f) PFNS at incident neutron energies above 1.0 MeV considered reliable for inclusion in nuclear data evaluations and no reliable data sets above 3.0 MeV incident neutron energy. In this work we report on new measurements of the 235 U(n,f) PFNS spanning a grid of 1.0–20.0 MeV in incident neutron energy and 0.01–10.0 MeV in outgoing (PFNS) neutron energy. These measurements were carried out at the Weapons Neutron Research facility at the Los Alamos Neutron Science Center and used a multifoil parallel-plate avalanche counter target with both a Li-glass and a liquid scintillator detector array in separate experiments to span the quoted outgoing neutron energy ranges. The PFNS results are shown in terms of the energy spectra themselves as well as the average PFNS energy $(\langle{E}\rangle)$ and ratios of $\langle{E}\rangle$ at forward and backward angles. Here, the results are compared with literature data and selected nuclear data evaluations. Generally, the data agree with the ENDF/B-VIII.0 evaluation below 5.0-MeV incident neutron energy and more closely with the JEFF-3.3 evaluation above 5.0 MeV, though no evaluations considered for comparison in this work agree with the data across all of the incident and outgoing neutron energies shown, especially in regions where the third-chance fission process becomes available. Additionally, we show a ratio of the present PFNS results for 235 U(n, f) with a recent and highly correlated experiment to measure the 239 Pu(n, f) PFNS at the same experimental facility and with nearly identical equipment and analysis procedures. Many observations reported in this work are the first of their kind and represent significant advancements for knowledge of the 235 U(n, f) PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ORNL Package Testing Program Overview

When transporting radioactive or hazardous materials, safety and security are top priorities. Packaging and transportation regulations require reliable evidence that containers have passed rigorous performance tests to ensure that the public and the environment are protected from the hazardous nature of the cargo. Because of its long history in energy and security research, Oak Ridge National Laboratory (ORNL) has needed to ship hazardous packages for the past 65 years. Since the 1940s, ORNL has made significant contributions to transportation regulations and has been at the forefront of regulatory testing development. Today, ORNL is a leader in standards development and testing of designs of radioactive material packages. ORNL plays a critical role in ensuring the safe transportation of radioactive materials across the United States by executing rigorous testing campaigns of packages that contain radioactive materials. Early testing activities focused on supporting the development of transportation regulations established by both the International Atomic Energy Agency (IAEA) and the United States. Currently, all package testing activities are performed under the Package Testing Program (PTP) at the Package Evaluation Facility (PEF) located at the National Transportation Research Center (NTRC), which is about 10 miles from the main ORNL campus. The PTP develops and evaluates testing solutions, ensuring that they are safe efficient, and in compliance with regulatory requirements. The vision for the PTP is to be a world-class leader in the evaluation and testing of radioactive and hazardous material packages. The key elements necessary to fulfill this mission are an experienced and professional staff; state-of-the-art facilities, equipment, and instrumentation; and completion of challenging programs and projects important to package transportation. Collaborations with other internal and external organizations play a significant role in building stronger teams and achieving this vision. By adhering to and advancing regulatory standards, ORNL’s PTP supports development of safe and compliant packaging, safeguarding the transportation process from potential risks associated with radioactive material logistics.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Application of Cable Condition Monitoring Technologies to Assess Age-Related Degradation of Industrial Cables Installed in Harsh Environments

The aging of electrical cables has been the subject of substantial research and development (R&D) projects performed by national and international laboratories, universities, and private organizations for many years. This R&D was conducted to develop guidance, equipment, and techniques to support aging management of in-service cables in industrial facilities such as nuclear power plants, research reactors, waste facilities, and fuel fabrication plants. Through these research efforts, condition monitoring technologies have been developed that can determine the severity of age-related degradation that occurs in industrial cables and insulation polymers during service. This paper summarizes the results of aging assessments that were performed for cables installed in two U.S. nuclear power plants, one a pressurized water reactor and one a boiling water reactor. These cables had been in service for over 40 years and during plant operation were exposed to harsh environmental conditions including elevated temperatures and radiation. For these assessments, a comprehensive series of measurements was performed to assess the aged condition of the cables. These cables came from different manufacturers, were manufactured in different years, and were constructed with a variety of jacket and insulation polymers including chloro-sulfonated polyethylene (CSPE), cross-linked polyethylene (XLPE)/cross-linked polyolefin (XLPO), neoprene, and ethylene propylene rubber (EPR). The goal of these assessments was to determine the current aged condition of the cable polymers and provide an estimate of how long the cable insulation materials could remain exposed to their in-service environmental conditions before reaching their end-of-life condition. Both nuclear power plants have received license renewals to extend their operation from 40 to 60 years, and the utilities need objective evidence to show that critical components such as cables will be able to function safely and reliably during the extended operating period. Furthermore, the results of these assessments showed that the cables exhibited different aged conditions depending on the type of polymers they were constructed with and the environment they were exposed to during service. Some of the cables and insulation polymers showed signs of significant age-related degradation and were estimated to have approximately 5 years of remaining service life. Other cables exhibited no signs of significant age-related degradation and were estimated to have 50 years or more of remaining service life. Using the results of these cable aging assessments, plant personnel were able to (1) determine the overall aged condition of cables and insulation polymers using objective test results, (2) identify aged or degraded cables before they caused operability issues, and (3) avoid unnecessary and costly replacement of cables that can continue to operate safely and reliably.

36 MATERIALS SCIENCE↗

RELAP-7 Application and Enhancement for FLEX Strategies and ATF Behavior under Extended Loss of AC Power Conditions

This report summarizes the results of a three-year research project sponsored by the U.S. Department of Energy (DOE) Nuclear Energy University Program (NEUP) to enhance and apply the RELAP-7 code by adding and improving several important components (e.g., a mechanistic Reactor Core Isolation Cooling (RCIC) system model) for thermal hydraulic studies of LWRs under ELAP conditions and evaluating the time available for transition to portable FLEX equipment. The project team included University of Massachusetts–Lowell, The Ohio State University, Texas A&M University, Idaho National Laboratory and Oak Ridge National Laboratory. In the Fukushima accident, it was found that the RCIC system played a crucial role in delaying core meltdown by almost three days in Fukushima Daiichi Unit 2, because of self-regulated operation of the steam driven RCIC turbine-pump injection system. Steam flow in the convergent-divergent nozzles of the RCIC Terry turbine is two-phase non-equilibrium transonic flow with homogenous nucleation condensation. To more accurately predict the dynamic process and behavior of the transonic compressible steam flow, a one-dimensional transient two-phase analytical model is presented. A simplified four-fluid model was employed in the present work with the consideration of four separate fluid fields: vapor, liquid film, entrained droplets and condensed droplets. The mass, momentum and energy interactions between the fluids were considered and modeled. An extended seven-equation non-equilibrium critical flow model was developed to obtain the critical pressure and velocities of each phase at the nozzle throat. To predict the wetness in the divergent section, a mechanistic nucleation condensation model was integrated in the nozzle analysis model, considering the generation and consequent growth of droplets. The governing differential equations on a staggered grid were discretized using the second-order Lax-Wendroff scheme with a flux limiter, and the Semi-Implicit Method for Pressure-Linked Equation (SIMPLE) algorithm was employed to solve the discrete linear system. To demonstrate the predictability and reliability of the physical models and the numerical method proposed in the present work, three representative nozzles were modeled and simulated. The results show good agreement with the available experimental data, even for condensation shock. Then, the 1D nozzle model was employed to obtain nozzle flow tables of the Terry turbine nozzle for different working pressures which can cover the operation pressure range of the RCIC system. A mechanistic RCIC turbine-pump system model was developed and implemented in the system code TRACE to simulate dynamic responses of the RCIC system under Beyond Design Basis Accident (BDBA) conditions. The turbine-pump governing equations are based on the control volume approach of the angular momentum balance. The physics based mechanistic RCIC model was developed using the TRACE control system components (i.e., signal variables, control blocks, and tables), and incorporated into a TRACE boiling water reactor (BWR) model. The TRACE model in this report has a detailed nodalization of the reactor pressure vessel (RPV), and all of the major flow paths and system components, including the safety relief valves (SRVs) and the containment suppression pool and drywell. Based on the nozzle flow tables generated from the 1D nozzle model developed, the turbine drive torque can be calculated from table lookup. Since the detailed specifications of the RCIC pump are unavailable, the homologous curves for a Bingham pump were used in the current pump component. A station black-out (SBO) accident test problem was selected to demonstrate the TRACE RCIC model. The short-term SBO simulations were performed for two cladding materials: Zircaloy and FeCrAl, to demonstrate the effect of the accident tolerant fuel cladding on fuel heat-up under BDBA accident conditions. The wetwell plays a vital safety role in SBO and other BWR accident scenarios in that it can reduce containment pressure and supply additional core make-up water. The suppression pool temperature distribution has a very large impact on both RPV and containment pressure. Thus, another novel contribution of the project comes mainly from an improved, systems-level wetwell model which can capture buoyancy-induced thermal stratification effects due to steam injection and condensation. A two-zone stratified wetwell model has been implemented in RELAP-7 and some results from that model are presented. This wetwell model is capable of simulating thermal stratification due to a low steam mass injection rate. With a low mass flow rate, the model assumes that all the steam condenses within the pipe and the resulting plume can be approximated with a purely buoyant, heat-source driven model. The wetwell model developed with these assumptions is adequate to simulate slow transients such as extended SBO transients.

42 ENGINEERING↗

Hydrogen Energy Storage Integrated with a Combined Cycle Plant

A project is being developed that will build upon the existing infrastructure and resources at the Intermountain Power Project (IPP) site to provide reliable, dispatchable energy and to support the transmission of renewable energy resources while transitioning to an economical green energy future. The concept study depicted in this report outlines a techno-economic optimization to fulfill the demand for 30% vol hydrogen co-firing in the IPP 840 MW advanced class combined cycle power plant. In an initial step, a site assessment concluded the site has sufficient land available to co-locate a hydrogen production and storage facility. The team evaluated and defined a scalable concept that considered technology characteristics, including input and output models to be used for optimization purposes. The concept for the hydrogen production and storage system integrates multiple technologies, to determine system size and scalable approach, for each of the technologies evaluated, the team defined component and subcomponent sizes, minimum and maximum capacity, modularity, component utility consumption (electric, water), component flexibility and servicing, layout, and technology status, as well as technology alternatives. For hydrogen generation, the project considers Siemens Energy’s Silyzer-300 (S300) technology, a 17.5 MW modular Proton Exchange Membrane (PEM) electrolyzer. For the S300 configuration, the team determined that three S300 arrays, or approximately 1,000 kg/hr, per block would yield a compact block design. This configuration results in a fairly wide and flexible arrangement that fits well into the spaces available at the site. Therefore, the overall design approach is based on multiple identical blocks of 3 arrays to minimize engineering cost and optimize constructability. In parallel, a transmission screening study was conducted to determine any potential transmission constraints from the energy sources that could feed the hydrogen production equipment. The study results show that minimum transmission constraints would be encountered to deliver 400 MW renewable generation from southern California, or south-central Wyoming. At last, the techno-economic analysis concluded that a scenario that uses solar and wind power yields the lowest levelized cost of hydrogen (LCOH 2 ) production and the lowest cost per tonne of CO 2 reduced. In this optimized scenario, the hydrogen production plant was determined as 6,201 kg/hr and the hydrogen storage (underground cavern) was determined as 4,600 tonnes. The resulting capacity factor for the hydrogen production plant was 66.33% with 8,745 operating hours in one year. This techno-economic analysis provided various options for integrating hydrogen storage at the Intermountain Power Plant site to co-fire the CCPP units. The results provide insightful data about the magnitude of capacity needed and the economics of producing hydrogen and reducing CO 2 emissions.

08 HYDROGEN↗