Search NASA⌕ Search

SEARCH · Search NASA

Results for “error quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Discrimination and quantification of implanted solar wind in Genesis collector shards using grazing incidence synchrotron x-ray techniques: New detector initial results

Accurate knowledge of the composition of the Sun provides a baseline, which allows an understanding of how the solar system has evolved over time and how solar processes and solar wind mechanics behave. Unfortunately, the errors in photospheric abundances are too large for many planetary science problems and this hampers our understanding of these different processes. Analyses of solar wind implanted in meteorites or lunar soils have provided more precise data [e.g. 1 and references therein] but the extent to which alteration processes on these bodies complicate such information is only now being determined. Therefore, in order to obtain pristine solar wind samples, NASA developed and launched the Genesis Discovery Mission. Unfortunately, the probe crash-landed shattering the 300 collector plates into 15,000+ pieces complicating the analysis and necessitating the development of new analytical techniques and equipment. Thus, shards from the Genesis collector array and their appropriate flight spares are currently being characterized via grazing-incidence synchrotron x-ray techniques at the Advanced Photon Source at Argonne National Laboratory. The goals are (1) determine solar wind fluences of the elements Ca-Ge by grazing-incidence angle-resolved x-ray fluorescence (XRF) and x-ray reflectivity, (2) improve data reduction via the development of XRF spectral deconvolution routines and develop modeling algorithms for reflectivity and fluorescence yield analysis in order to determine element specific depth profiles from which absolute concentration may be extracted and (3) designing and developing a new multi-element silicon multi-channel (SMCD) detector system. These improvements will increase our sensitivity by a factor of three or more, reduce measurement time at a given sensitivity to one-eighth and the minimum detection limit would be reduced by a factor of 3 to {approx}3 x 10{sup 8} atoms/cm{sup 2}.

43 PARTICLE ACCELERATORS↗

How does uncertainty of soil organic carbon stock affect the calculation of carbon budgets and soil carbon credits for croplands in the U.S. Midwest?

Cropland carbon budget depicts the amount of carbon flowing in and out of agroecosystems and the changes in carbon stocks of soil and living biomass during the same period. Soil carbon credit is the additional change in soil carbon stock under certain farming practices compared with the business-as-usual practices. Accurately calculating cropland carbon budget and soil carbon credit is critical to assessing climate change mitigation potential in agroecosystems. The calculation of cropland carbon budget and soil carbon credit is sensitive to local soil and climatic conditions, especially initial soil organic carbon (SOC) stock, which is determined by both SOC concentration (SOC%) and bulk density (Bulk_Density). SOC stock data are either from soil sampling or gridded public survey data. In agroecosystem models, SOC stock data are a key model input for quantifying cropland carbon budget and soil carbon credit. However, various types and degrees of uncertainties exist in SOC stock datasets, which propagate to the quantification of SOC stock change. In particular, a large discrepancy is found in two widely used SOC stock datasets — Rapid Carbon Assessment dataset (RaCA) and Gridded Soil Survey Geographic Database (gSSURGO) — in the U.S. Midwest, with a relative difference (quantified using Normalized Root Mean Square Error, NRMSE) of 48.0% for 0–30 cm SOC stock between the two datasets. It remains largely unclear how uncertainty in SOC stocks affects the calculation of cropland carbon budget and soil carbon credit. To address this question, we used a well-validated process-based agroecosystem model, ecosys, to assess the impacts of SOC stock uncertainty on carbon budget and soil carbon credit calculation in the U.S. Midwestern corn-soybean rotation systems. Our results reveal the following findings: (1) A sizable discrepancy exists in simulated cropland carbon budget between using gSSURGO and using RaCA for their SOC% and Bulk_Density as model inputs, with a Pearson correlation coefficient (r) of only 0.4 for simulated change of SOC stock (ΔSOC) using these two different soil datasets. (2) Simulated cropland carbon budget components were more sensitive to initial SOC% than to Bulk_Density. For example, the upper and lower quartiles of multi-year averaged ΔSOC were –29.8 and 4.8 gC/m 2 /year for the selected counties respectively, with an uncertainty of 13.7 and 0.7 gC/m 2 /year induced by uncertainties in initial SOC% and Bulk_Density, respectively. (3) Both simulated ΔSOC and its uncertainty were negatively correlated with initial SOC%, whereas ΔSOC was negatively correlated with air temperature, and ΔSOC uncertainty was positively correlated with air temperature. (4) The uncertainty of calculated soil carbon credits was much smaller compared with the uncertainty of calculated absolute carbon budgets assuming the same SOC stock uncertainty level in the inputs. Specifically, in our assessment comparing planting cover crops vs no cover crop, the uncertainty of calculated soil carbon credits induced by initial SOC% uncertainty was less than 4% (relative to the quantified value of the soil carbon credits) for 90% of the cases. Our analysis highlights that high accuracy measurement of SOC% as inputs is needed for the calculation of cropland carbon budgets; however, soil carbon credit quantification is much less sensitive to the initial SOC% inputs, and the current publicly available soil datasets (e.g., gSSURGO) are largely suitable for the calculation of soil

54 ENVIRONMENTAL SCIENCES↗

Remote sensing of Pu in uranyl nitrate crystals using reflectance spectroscopy and chemometrics

Remote quantification of Pu(VI) (0–5 mol%) co-crystallized with U in uranyl nitrate hexahydrate (UNH) crystals was achieved in a glove box using reflectance spectroscopy coupled with chemometric modeling. Reflectance spectra were also acquired for Pu(IV) and Np(VI) (0–5 mol%) crystallized with UNH; revealing spectral features consistent with their solution-phase analogs. Principal component analysis revealed Pu(IV/VI) and Np(VI) concentrations as the primary source of variation in the data, informing the development of a supervised partial least squares regression model for Pu(VI). The resulting calibration demonstrated robust performance, with replicate root mean square errors near 10% and quantifiable limits near 0.2 mol% Pu(VI) relative to U. The Pu(VI) remained stable in the crystalline UNH matrix for at least one week with minimal reduction to Pu(IV). Notably, Pu(VI) and Np(VI) incorporation in UNH quenched U(VI) fluorescence while Pu(IV) did not. This study presents a noninvasive, spectroscopic approach for solid-state Pu quantification, with direct implications for material accountability and nuclear nonproliferation monitoring.

Sadergaski, Luke R. [Oak Ridge National Laboratory↗

Natural Gas Fugitive Leak Detection Using an Unmanned Aerial Vehicle: Measurement System Description and Mass Balance Approach

Natural gas is an abundant resource across the United States, of which methane (CH4) is the main component. About 2% of extracted CH4 is lost through leaks. The Remote Methane Leak Detector (RMLD)-Unmanned Aerial Vehicle (UAV) system was developed to investigate natural gas fugitive leaks in this study. The system is composed of three major technologies: miniaturized RMLD (mini-RMLD) based on Backscatter Tunable Diode Laser Absorption Spectroscopy (TDLAS), an autonomous quadrotor UAV and simplified quantification and localization algorithms. With a miniaturized, downward-facing RMLD on a small UAV, the system measures the column-integrated CH4 mixing ratio and can semi-autonomously monitor CH4 leakage from sites associated with natural gas production, providing an advanced capability in detecting leaks at hard-to-access sites compared to traditional manual methods. Automated leak characterization algorithms combined with a wireless data link implement real-time leak quantification and reporting. This study placed particular emphasis on the RMLD-UAV system description and the quantification algorithm development based on a mass balance approach. Early data were gathered to test the prototype system and to evaluate the algorithm performance. The quantification algorithm derived in this study tended to underestimate the gas leak rates and yielded unreliable estimations in detecting leaks under 7 × 10 − 6 m3/s (~1 Standard Cubic Feet per Hour (SCFH)). Zero-leak cases can be ascertained via a skewness indicator, which is unique and promising. The influence of the systematic error was investigated by introducing simulated noises, of which Global Positioning System (GPS) noise presented the greatest impact on leak rate errors. The correlation between estimated leak rates and wind conditions were investigated, and steady winds with higher wind speeds were preferred to get better leak rate estimations, which was accurate to approximately 50% during several field trials. High precision coordinate information from the GPS, accurate wind measurements and preferred wind conditions, appropriate flight strategy and the relative steady survey height of the system are the crucial factors to optimize the leak rate estimations.

03 NATURAL GAS↗

Complete quantification of parametric uncertainties in ( d , p ) transfer reactions

Deuteron-induced transfer reactions are a popular probe in nuclear structure and nuclear astro physics studies. The interpretation of these transfer measurements relies on reaction theory that takes as input effective interactions between the nucleons and the target nucleus. Previous work quantified the uncertainty associated with the optical potentials between the nucleons and the target. In this study, we extend that work by also including the parameters of the mean field associated with the overlap function of the final bound state, thus obtaining the full parametric uncertainty on transfer observables. We use Bayesian Markov Chain Monte Carlo simulations to obtain parameter posterior distributions. We use elastic-scattering cross sections to constrain the optical potential parameters and use the asymptotic normalization coefficient of the final state to constrain the bound state interaction. We then propagate these posteriors to the transfer angular distributions and obtain confidence intervals for this observable. We study (d,p) reactions on 14 C, 16 O, and 48 Ca at energies in the range $E$ $d$ = 7 - 24 MeV. Our results show a strong reduction in uncertainty by using the asymptotic normalization coefficient as a constraint, particularly for those reactions most sensitive to ambiguities in the mean field. For those reactions, the importance of constraining the bound state interaction is equal to that of constraining the optical potentials. Furthermore, the case of 14 C is an outlier because the cross section is less sensitive to the nuclear interior. When minimal constraints are used on the parameters of the nucleon-target interaction, the 1σ uncertainties on the differential cross sections are large (~ 500-100%). However, if elastic-scattering data and the asymptotic normalization coefficient are used in the analysis, with an error of 10% (5%), this uncertainty reduces to ~ 30% (~ 15%).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A quantifiable and automated volume fraction characterization technique for secondary and tertiary γ′ precipitates in Ni-based superalloys

Highlights: • A new, automated γ′ volume fraction characterization technique has been introduced for Ni-base superalloys. • New image processing techniques can automatically and accurately segment γ′ precipitates from the surrounding γ matrix. • CALPHAD and γ′ phase extraction measurements validate the new characterization technique. - Abstract: Ni-based superalloys are extensively used in high temperature, high stress applications. The presence of coherent γ′-Ni{sub 3}Al precipitates provides the requisite elevated temperature strength and creep resistance in these alloys. Therefore, quantification of the precipitate size distribution and volume fraction is essential for accurate model predictions and future alloy design. Current γ′ volume fraction characterization techniques suffer from a lack of precision and repeatability. Without a reproducible procedure, unacceptable variations and errors have plagued the past 6 decades of superalloys research and have inhibited the implementation of accurate precipitation models for these alloys. Through the use of high resolution, low kV, scanning electron microscopy and state-of-the-art image post-processing, a new, accurate γ′ characterization technique is presented. Using the new technique, secondary γ′ volume fractions in superalloy ME3 were calculated, and confirmed through phase extraction, thus opening the possibility for validation of presently used superalloy precipitation databases.

36 MATERIALS SCIENCE↗

Sensitivity and Uncertainty Analysis of Plutonium and Cesium Isotopes in Modeling of BR3 Reactor Spent Fuel

Nuclear forensics has a broad task to characterize recovered nuclear or radiological material and interpret the results of investigation. One approach to isotopic characterization of nuclear material obtained from a reactor is to chemically separate and perform isotopic measurements on the sample and verify the results with modeling of the sample history, for example, operation of a nuclear reactor. The major actinide plutonium and fission product cesium are commonly measured signatures of the fuel history in a reactor core. This study investigates the uncertainty of the plutonium and cesium isotope ratios of a fuel rod discharged from a research pressurized water reactor when the location of the sample is not known a priori. A sensitivity analysis showed overpredicted values for the 240 Pu/ 239 Pu ratio toward the axial center of the rod and revealed a lower probability of the rod of interest (ROI) being on the periphery of the assembly. The uncertainty analysis found the relative errors due to only the rod position and boron concentration to be 17% to 36% and 7% to 15% for the 240 Pu/ 239 Pu and 137 Cs/ 135 Cs ratios, respectively. Lastly, this study provides a method for uncertainty quantification of isotope concentrations due to the location of the ROI. Similar analyses can be performed to verify future chemical and isotopic analyses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Benchmarking of Different Inverse Point Kinetics Implementations for an Autocorrected Reactimeter Algorithm

In November 2017, the Transient Reactor Test Facility returned to operation. Since that time, many transient test series have been completed; each has provided valuable data for materials performance, reactor safety that can be applied in future designs. During each experimental series, detector count rates provided important information on the core behavior during transients. However, a limitation of these data is that variations in the neutron distribution during experiments cause errors when attempting to infer reactivity evolution from detector signals. Neutron physics codes can be used to compute the flux shape variations. However, this is a poor solution when the experimental data is used to do verification, validation and uncertainty quantification (VVUQ) on codes. Indeed, if the output of the code is used both as a reference and to correct what the reference is compared to, the circular dependency limits the quality of the VVUQ approach. To overcome this problem, an Autocorrected Reactimeter Algorithm (ACRA) has been developed. This approach infers time-dependent reactivity evolution by testing different spatial corrections and selecting the one that minimizes reactivity variations when the core is in a frozen configuration (i.e. when there is no variation in parameters affecting reactivity). However, the scope of this method was limited to transients where there were negligible thermal feedback. Indeed, the core is never in a frozen configuration when the fuel temperature varies during the whole transient. This is our motivation for the development of an improved version of the ACRA which does not require frozen configurations

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Uncertainty Quantification in Wind Plant Energy Estimation: Preprint

Data characterizing a wind power plant's production is important for the validation, calibration, and refinement of the wake loss models used to simulate performance for pre-construction energy estimates. In this process, there is the potential for significant variation in the methods used by an analyst for, first, the preparation of the operational production data for comparison to model data and, second, the generation of analogous production data from simulations. In this work, the uncertainty introduced by these method variations is quantified by considering ensembles of analysis methods. Specifically, 1920 methods variations were developed for preparing the operational data as a predictable production benchmark and simulations taking as input sample sets of the observed wind resource ranged in size from covering 4% to 125% of a full year were run using 3 engineering wake loss models in FLORIS simulations. The benchmark and simulation input uncertainties place lower bounds on the precision of the calibration between the simulation model estimates and operational benchmark data. Even within subsets of method variations (representative of what might be seen within a single company), the uncertainty in the predictable expected production is estimated to be between 1% and 3% the median predictable expected production while the uncertainty in the simulated expected production remains at best on the order of 2%. To put this into context: the simulated expected production is very closely related to the annual energy production (AEP) metric commonly used to quantify a plant's predicted performance and a 3% error in the pre-construction AEP estimate can result in a $17M loss due to additional financing costs for a typical 100MW Texas plant.

17 WIND ENERGY↗

Analytical comparisons of handheld LIBS and XRF devices for rapid quantification of gallium in a plutonium surrogate matrix

This work compares a portable laser-induced breakdown spectroscopy (LIBS) analyzer to a portable X-ray fluorescence (XRF) device for quantification of gallium (Ga) in a plutonium surrogate matrix of cerium (Ce) for the first time. Calibration methods are developed with spectra of Ce–Ga samples from both devices. Here, metrics such as limit of detection (LoD) and mean average percent error (MAPE) are examined to evaluate calibration performance. While the portable LIBS device can yield a nearly instantaneous analytical measurement, its accuracy is hampered by self-absorption. By employing a self-absorption correction and increasing gating delay, LIBS calibrations with errors in the low single percents and LoDs of 0.1% Ga were constructed. The XRF device produces calibrations with superlative sensitivity, yielding LoDs for gallium in the low tens of parts-per-million (ppm), two orders of magnitude lower than the corrected LIBS models. However, a clear trade-off of measurement fidelity is established between the instantaneous analysis of the LIBS device and the minutes-long XRF measurement yielding superior detection limits.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Novel Modeling Framework for Computationally Efficient and Accurate Real-Time Ensemble Flood Forecasting With Uncertainty Quantification

A novel modeling framework that simultaneously improves accuracy, predictability, and computational efficiency is presented. It embraces the benefits of three modeling techniques integrated together for the first time: surrogate modeling, parameter inference, and data assimilation. The use of polynomial chaos expansion (PCE) surrogates significantly decreases computational time. Parameter inference allows for model faster convergence, reduced uncertainty, and superior accuracy of simulated results. Ensemble Kalman filters assimilate errors that occur during forecasting. To examine the applicability and effectiveness of the integrated framework, we developed 18 approaches according to how surrogate models are constructed, what type of parameter distributions are used as model inputs, and whether model parameters are updated during the data assimilation procedure. We conclude that (1) PCE must be built over various forcing and flow conditions, and in contrast to previous studies, it does not need to be rebuilt at each time step; (2) model parameter specification that relies on constrained, posterior information of parameters (so-called Selected specification) can significantly improve forecasting performance and reduce uncertainty bounds compared to Random specification using prior information of parameters; and (3) no substantial differences in results exist between single and dual ensemble Kalman filters, but the latter better simulates flood peaks. The use of PCE effectively compensates for the computational load added by the parameter inference and data assimilation (up to ~80 times faster). Therefore, the presented approach contributes to a shift in modeling paradigm arguing that complex, high-fidelity hydrologic and hydraulic models should be increasingly adopted for real-time and ensemble flood forecasting.

54 ENVIRONMENTAL SCIENCES↗

WE-AB-204-05: Harmonizing PET/CT Quantification in Multicenter Studies: A Case Study

Purpose: To present the implementation of a strategy to harmonize FDG PET/CT quantification (SUV), performed with different scanner models and manufacturers. Methods: The strategy was based on Boellaard (2011) and EARL FDG-PET/CT accreditation program, that propose quality control measurements for harmonizing scanner performance. A NEMA IEC Body phantom study was performed using four different devices: PHP-1 (Gemini TF Base, Philips); PHP-2 (Gemini GXL, Philips); GEH (Discovery 600, General Electric); SMS (Biograph Hi-Rez 16, Siemens). The SUV Recovery Coefficient (RC) was calculated using the clinical protocol and other clinically relevant reconstruction parameters. The most appropriate reconstruction parameters (MARP) for SUV harmonization, in each scanner, are those which achieve EARL harmonizing standards. They were identified using the lowest root mean square errors (RMSE). To evaluate the strategy’s effectiveness, the Maximum Differences (MD) between the clinical and MARP RC values were calculated. Results: The reconstructions parameters that obtained the lowest RMSE are: FBP 5mm (PHP-1); LOR-RAMLA 2i0.008l (PHP-2); VuePointHD 2i32s10mm (GEH); and FORE+OSEM 4i8s6mm (SMS). Thus, to ensure that quantitative PET image measurements are interchangeable between these sites, images must be reconstructed with the above-mentioned parameters. Although, a decoupling between the best image for PET/CT qualitative analysis and the best image for quantification studies was observed. The MD showed that the strategy was effective in reducing the variability of SUV quantification for small structures (<17mm). Conclusion: The harmonization strategy of the SUV quantification implemented with these devices was effective in reducing the variability of small structures quantification, minimizing the inter-scanner and inter-institution differences in quantification. However, it is essential that, in addition to the harmonization of quantification, the standardization of the methodology of patient preparation must be maintained, in order to minimize the SUV variability due to biological factors. Financial support by CAPES.

60 APPLIED LIFE SCIENCES↗

Quantification of modeling uncertainty in the Rayleigh damping model

Understanding and accurately characterizing energy dissipation mechanisms in civil structures during earthquakes is an important element of seismic assessment and design. The most commonly used model is attributed to Rayleigh. This paper proposes a systematic approach to quantify the uncertainty associated with Rayleigh's damping model. Bayesian calibration with embedded model error is employed to treat the coefficients of the Rayleigh model as random variables using modal damping ratios. Through a numerical example, we illustrate how this approach works and how the calibrated model can address modeling uncertainty associated with the Rayleigh damping model.

42 ENGINEERING↗

Data coverage assessment on neural network based digital twins for autonomous control system

We report in a recently developed Nearly Autonomous Management and Control (NAMAC) system, neural networks (NNs) are used to develop digital twins for diagnosis (DT-Ds). However, NNs are not usually considered extrapolation models and may result in large errors if they are applied to unseen data outside the training data (uncovered). In this study, we propose a data coverage assessment (DCA) to determine if the NN-based DT-Ds are extrapolated based on their epistemic uncertainty. The uncertainty quantification algorithms and uncertainty thresholds are selected based on the confusion matrix of classifying evaluation data into covered or uncovered data. To demonstrate the adaptability of the proposed framework, we applied it to a basic feedforward neural network and a more advanced recurrent neural network based on a more nonlinear database. Case studies show that the proposed framework can distinguish unseen data for both basic and advanced applications with proper uncertainty quantification algorithms and thresholds.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Atikokan Digital Twin: Machine learning in a biomass energy system

The Atikokan Generating Station, operated by Ontario Power Generation, has a 200 MW, biomass-fired tower boiler that operates on a dispatch schedule with a five-minute cycle. The boiler is generally operated in the range of 40–100 MW using two of five burner levels. In order to optimize boiler performance, we propose the implementation of a unique digital twin. Our digital twin abstraction couples Bayesian inference from science-based models and from observations (machine learning) with decision theory to predict operating-variable set points that optimize the physical asset (the boiler) in the presence of uncertainty (artificial intelligence). We focus this paper on the continuous Bayesian machine learning part of the Atikokan Digital Twin; we discuss decision theory in a companion paper. We identify and learn about 12 operational, model, and measured-output parameters and their uncertainties from high-fidelity, science-based simulations of the Atikokan boiler and from the observed measurements at the power plant. Since the goal of the Atikokan Digital Twin is to implement it online in real time, we require fast function evaluations for the quantities of interest extracted from the simulations in the Bayesian analysis. We use Gaussian process regression/interpolation to create accurate, robust surrogate models. We define the Bayesian priors and likelihood function and solve for the posterior distributions of the 12 parameters. Here we then propagate these distributions (i.e., parameters with uncertainty) into the predicted distributions of 790 quantities of interest to learn about the relative importance of various sources of error including experimental, model, and operating-parameter errors.

09 BIOMASS FUELS↗

Development of an exchange–correlation functional with uncertainty quantification capabilities for density functional theory

This paper presents the development of a new exchange–correlation functional from the point of view of machine learning. Using atomization energies of solids and small molecules, we train a linear model for the exchange enhancement factor using a Bayesian approach which allows for the quantification of uncertainties in the predictions. A relevance vector machine is used to automatically select the most relevant terms of the model. We then test this model on atomization energies and also on bulk properties. The average model provides a mean absolute error of only 0.116 eV for the test points of the G2/97 set but a larger 0.314 eV for the test solids. In terms of bulk properties, the prediction for transition metals and monovalent semiconductors has a very low test error. However, as expected, predictions for types of materials not represented in the training set such as ionic solids show much larger errors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Processing Aleatory and Epistemic Uncertainties in Experimental Data From Sparse Replicate Tests of Stochastic Systems for Real-Space Model Validation

This paper presents a practical methodology for propagating and processing uncertainties associated with random measurement and estimation errors (that vary from test-to-test) and systematic measurement and estimation errors (uncertain but similar from test-to-test) in inputs and outputs of replicate tests to characterize response variability of stochastically varying test units. Also treated are test condition control variability from test-to-test and sampling uncertainty due to limited numbers of replicate tests. These aleatory variabilities and epistemic uncertainties result in uncertainty on computed statistics of output response quantities. The methodology was developed in the context of processing experimental data for “real-space” (RS) model validation comparisons against model-predicted statistics and uncertainty thereof. The methodology is flexible and sufficient for many types of experimental and data uncertainty, offering the most extensive data uncertainty quantification (UQ) treatment of any model validation method the authors are aware of. It handles both interval and probabilistic uncertainty descriptions and can be performed with relatively little computational cost through use of simple and effective dimension- and order-adaptive polynomial response surfaces in a Monte Carlo (MC) uncertainty propagation approach. A key feature of the progressively upgraded response surfaces is that they enable estimation of propagation error contributed by the surrogate model. Sensitivity analysis of the relative contributions of the various uncertainty sources to the total uncertainty of statistical estimates is also presented. Finally, the methodologies are demonstrated on real experimental validation data involving all the mentioned sources and types of error and uncertainty in five replicate tests of pressure vessels heated and pressurized to failure. Simple spreadsheet procedures are used for all processing operations.

97 MATHEMATICS AND COMPUTING↗

Evaluation of in vivo quantification accuracy of the Ingenuity-TF PET/MR

Purpose: The quantitative accuracy of standardized uptake values (SUVs) and tracer kinetic uptake parameters in patient investigations strongly depends on accurate determination of regional activity concentrations in positron emission tomography (PET) data. This determination rests on the assumption that the given scanner calibration is valid in vivo. In a previous study, we introduced a method to test this assumption. This method allows to identify discrepancies in quantitative accuracy in vivo by comparison of activity concentrations of urine samples measured in a well-counter with activity concentrations extracted from PET images of the bladder. In the present study, we have applied this method to the Philips Ingenuity-TF PET/MR since at the present stage, absolute quantitative accuracy of combined PET/MR systems is still under investigation. Methods: Twenty one clinical whole-body F18-FDG scans were included in this study. The bladder region was imaged as the last bed position and urine samples were collected afterward. PET images were reconstructed including MR-based attenuation correction with and without truncation compensation and 3D regions-of-interest (ROIs) of the bladder were delineated by three observers. To exclude partial volume effects, ROIs were concentrically shrunk by 8–10 mm. Then, activity concentrations were determined in the PET images for the bladder and for the urine by measuring the samples in a calibrated well-counter. In addition, linearity measurements of SUV vs singles rate and measurements of the stability of the coincidence rate of “true” events of the PET/MR system were performed over a period of 4 months. Results: The measured in vivo activity concentrations were significantly lower in PET/MR than in the well-counter with a ratio of the former to the latter of 0.756 ± 0.060 (mean ± std. dev.), a range of 0.604–0.858, and a P value of 3.9 ⋅ 10{sup −14}. While the stability measurements of the coincidence rate of “true” events showed no relevant deviation over time, the linearity scans revealed a systematic error of 8%–11% (avg. 9%) for the range of singles rates present in the bladder scans. After correcting for this systematic bias caused by shortcomings of the manufacturers calibration procedure, the PET to well-counter ratio increased to 0.832 ± 0.064 (0.668 –0.941), P = 1.1 ⋅ 10{sup −10}. After compensating for truncation of the upper extremities in the MR-based attenuation maps, the ratio further improved to 0.871 ± 0.069 (0.693–0.992), P = 3.9 ⋅ 10{sup −8}. Conclusions: Our results show that the Philips PET/MR underestimates activity concentrations in the bladder by 17%, which is 7 percentage points (pp.) larger than in the previously investigated PET and PET/CT systems. We attribute this increased underestimation to remaining limitations of the MR-based attenuation correction. Our results suggest that only a 2 pp. larger underestimation of activity concentrations compared to PET/CT can be observed if compensation of attenuation truncation of the upper extremities is applied. Thus, quantification accuracy of the Philips Ingenuity-TF PET/MR can be considered acceptable for clinical purposes given the ±10% error margin in the EANM guidelines. The comparison of PET images from the bladder region with urine samples has proven a useful method. It might be interesting for evaluation and comparison of the in vivo quantitative accuracy of PET, PET/CT, and especially PET/MR systems from different manufacturers or in multicenter trials.

60 APPLIED LIFE SCIENCES↗