Search NASA⌕ Search

SEARCH · Search NASA

Results for “exceptions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Host-guest prospects of neodymium and gadolinium ultraphosphate frameworks for nuclear waste storage: Multi-temperature topological analysis of nanoporous cages in RP{sub 5}O{sub 14}

Highlights: • The temperature-dependent cage topologies of RP{sub 5}O{sub 14} (R = Nd or Gd) were examined. • A topological analysis revealed similar cage structure for RP{sub 5}O{sub 14} (R = Nd or Gd). • One exception: the 8/4 cage topology of NdP{sub 5}O{sub 14} lacks structural cross-linking. • Volume (UO{sub 2} or PuO{sub 2}) ≫ 8/4 topology in RP{sub 5}O{sub 14} (R = Nd or Gd). • RP{sub 5}O{sub 14} (R = Nd or Gd) are good prospective host media for nuclear waste storage. - Abstract: Rare-earth ultraphosphate (RP{sub 5}O{sub 14}) framework materials are potential host media for nuclear waste storage, since cages within their nanoporous structures have volumes that match well those of prospective guests such as uranium or plutonium ions. Good volume matches of host cages and guest compounds are nonetheless not the only structural requirement for ensuring viable nuclear waste storage. Host structures also need to be stable enough to withstand the typical environmental conditions of long-term storage of spent nuclear fuel. To this end, the nanoporous cage topologies of neodymium and gadolinium ultraphosphate, NdP{sub 5}O{sub 14} and GdP{sub 5}O{sub 14}, are investigated as a function of temperature. Topological analysis shows that, while both compounds are essentially isostructural, thus displaying the same type of cage structures, the cage volumes of NdP{sub 5}O{sub 14} are significantly larger than those of GdP{sub 5}O{sub 14}, with one stark exception. This exception concerns the cage of NdP{sub 5}O{sub 14} whose 8/4 topology lacks structural cross-linking that would otherwise give it much more strength. This 'squashed' cage appears to owe its origins to the specific nature of crystallographic twinning in NdP{sub 5}O{sub 14}, which causes strain that needs alleviating; squashing the 8/4 cage in NdP{sub 5}O{sub 14} would be the most susceptible option towards this end, since its cage manifests the weakest structural construct. GdP{sub 5}O{sub 14} succumbs to a gradual contraction of its 8/4 cage only with increasing temperature above 300 K; this is well below its second-order monoclinic-to-orthorhombic phase transition at 420–430 K; which is 420 K for NdP{sub 5}O{sub 14}. Fortunately, the volumes of heavy metal ions that arise from spent nuclear fuels do not match the size requirements of cages with 8/4 topology in RP{sub 5}O{sub 14} hosts needed for encapsulation; otherwise, radiation leakage of such containment would present a risk. Both NdP{sub 5}O{sub 14} and GdP{sub 5}O{sub 14} would therefore seem to offer good prospects as host media for nuclear waste storage.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Study of interatomic potential and thermal structural properties of β-Zn{sub 4}Sb{sub 3}

Highlights: ► The multi-body interatomic potentials of various models of β-Zn{sub 4}Sb{sub 3} have been developed to describe atomic interactions. ► The radial distribution function shows that the 10% vacancy of Zn site leads to the disorder of β-Zn{sub 4}Sb{sub 3}. ► The 10% vacancy of Zn site is the main cause of the exceptional low thermal conductivity. -- Abstract: Previous experimental research shows that the disordered Zn atoms in β-Zn{sub 4}Sb{sub 3} may have an important influence on its exceptionally low thermal conductivity and easily occurred phase transition. So the present work aims to study the influence of disordered Zn atoms on thermodynamics properties of β-Zn{sub 4}Sb{sub 3} by using molecular dynamics (MD) method. Firstly, based on first principles calculation and experimental results, the interatomic potentials of β-Zn{sub 4}Sb{sub 3} and MD analysis method are established, and the feasibility is verified. Then, the influence of disordered Zn atoms on thermal conductivity of β-Zn{sub 4}Sb{sub 3} is studied in detail. The simulation results indicate that the 10% vacant Zn atoms is the main reason for the exceptionally low thermal conductivity of β-Zn{sub 4}Sb{sub 3}, and it seems that the interstitial Zn atoms have little effect on its thermal conductivity.

36 MATERIALS SCIENCE↗

Nuclear Data Sheets for A = 84

The evaluated spectroscopic data are presented for 12 known nuclides of mass 84 (Ga, Ge, As, Se, Br, Kr, Rb, Sr, Y, Zr, Nb, Mo). Except for the stable nuclides {sup 84}Sr and {sup 84}Kr, extensive new data are available for all the other nuclides since the 1997 evaluation by J.K. Tuli (1997Tu02) of A = 84 nuclides. Many precise Penning-trap mass measurements since AME-2003 for A = 84 nuclides (2009Re03,2008Ha23,2008We10,2007Ke09,2006Ka48,2006De36,2006Ri15) have resulted in improved Q values and separation energies. However, many deficiencies still remain. Some examples are given below. Excited-state data for {sup 84}Ga and {sup 84}As are nonexistent, and those for {sup 84}Ge are scarce. The radioactive decay schemes of {sup 84}Ga, {sup 84}Ge, {sup 84}Se, {sup 84}Y (39.5 min), {sup 84}Y (4.6 s), {sup 84}Zr and {sup 84}Nb suffer from incompleteness and that for {sup 84}Mo decay is not known at all. The energy ordering of the two activities (39.5 min and and 4.6 s) of {sup 84}Y is not well established, although, high-spin with tentative spin-parity of (6+) is adopted here as the ground state of {sup 84}Y based on weak arguments. From a conference report published in 2000, it is clear that extensive experiments were done to investigate decays of {sup 84}Zr and {sup 84}Y, but details of these studies never appeared in literature and none were made available to the evaluators when requested from original authors. This evaluation was carried out as part of ENSDF workshop for Nuclear Structure and Decay Data Evaluators, organized and hosted by the 'Horia Hulubei' National Institute for Physics and Nuclear Engineering, Bucharest, Romania during March 30, 2009 - April 3, 2009. Names of the evaluators principally responsible for evaluation of individual nuclides are given under the respective Adopted data sets.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Alternative Ratemaking in the US: A Prerequisite for Grid Modernization or an Unwarranted Shift of Risk to Customers?

With increasing frequency, investor-owned electric utilities are requesting preferred cost recovery for "grid modernization" in multiple forms, from multi-year rate plans to riders. Utilities' claims that massive grid investment is necessary, and that exceptional investment requires exceptional cost recovery, are typically accepted by policymakers with little challenge. It is difficult for policymakers to resist the siren call of grid modernization's perceived outcomes, from improved reliability and resilience to reduced risks to safety and new customer technology adoption (electric vehicles, distributed energy resources, and more). This paper provides a contrarian viewpoint that is virtually absent as policymakers consider alternative ratemaking practices. It introduces the possibility that excess grid investment in the name of modernization is not only possible, and economically harmful, but has already occurred, encouraged by alternative ratemaking. It provides examples of common grid modernization expenditures the authors have identified as cost-ineffective in the course of their work. It also describes traditional grid planning practices with proven ability to address changing requirements over time, calling into question the need for exceptional grid modernization investment plans. Most important, the paper explains the moral hazard inherent in alternative ratemaking, and the fundamental shift in ratemaking risks and responsibilities from utilities to customers that results. The perspectives this paper presents are critical for policymakers to understand before adopting, extending, or expanding alternative ratemaking practices in their respective jurisdictions.

ENERGY PLANNING, POLICY, AND ECONOMY,POWER TRANSMI↗

The Diurnal Variation of the Aerosol Optical Depth at the ARM SGP Site

Abstract This study examines the diurnal variation of the aerosol optical depth (AOD) at 355 nm observed by Raman lidar (RL) at the Atmospheric Radiation Measurement Program Southern Great Plains (SGP) site under both clear and cloudy‐sky conditions. Here only cloudy‐skies when the lidar signal is not fully attenuated are considered. The daytime AOD and its variation from the RL showed an excellent agreement with the Aerosol Robotic Network, demonstrating that the RL‐retrieved AOD is not affected by solar background contamination. The climatological annual‐mean daytime‐mean AOD is only slightly larger than the nighttime‐mean AOD (by 1%–3%). However, day‐to‐day variations are observed such that the daytime‐ and nighttime‐mean AOD difference for a given day can be large (about 95% of days have differences within 0.2). The seasonal AOD diurnal range (i.e., the difference between the maximum and minimum values) relative to the mean was 10%–15% except in the winter when it was 44%. The seasonal‐mean cloudy‐sky AOD diurnal variation is similar to that for clear‐sky, except that the AODs are larger (the annual‐mean cloudy‐sky AOD is larger than the clear‐sky by 24%). The aerosol lidar ratio diurnal variations are also examined, which are 10%–20% for all seasons with a minimum near 9 a.m. to 15 p.m. for all seasons except winter. Also presented is the annual‐mean AOD from the Cloud‐Aerosol Lidar and Infrared Pathfinder Satellite at SGP site: its daytime AOD is about 0.1 smaller than nighttime AOD because of daytime solar background contamination.

54 ENVIRONMENTAL SCIENCES↗

Structural Modification of Nanocrystalline Ceria by Ion Beams

Using energetic ions, we have demonstrated effective modification of grain size in nanocrystalline ceria in the critical region for controlling exceptional size-dependent electronicionic conductivity. The grain size increases and follows an exponential law as a function of ion fluence that increases with temperature, while the cubic phase is stable under the irradiation. The unique self-healing response of radiation damage at grain boundaries is utilized to control the grain size at the nanoscale.

74 ATOMIC AND MOLECULAR PHYSICS↗

Oxidation potentials of phenols and anilines: correlation analysis of electrochemical and theoretical values

As described in the main text, we classified our voltammograms into four types. For phenols, most compounds were type I or type II, except four phenols that were type III (4-nitrophenol, 4-cyanophenol, DNOC, and 4-hydroxyacetphenone); and two phenols that were type IV (4-aminophenol and dopamine). Almost all of the compounds gave the same type by SCV and SWV, except for 2,4-dinitrophenol (whose current went up and down and therefore could be considered a type II or III), 4-cyanophenol (which fell into a type III for SCV, but whose current went up and down in SWV (type II or III)), and 4-hydroxyacetophenone (which was a type III in SCV, but a type II in SWV). The majority of the anilines were type I except for p-toluidine (type II) and 4-methyl-3-nitroaniline and 2-methoxy-5-nitroaniline (both were type I for SWV, but for SCV fell into type III and type II respectively).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-energy radiation damage in zirconia: Modeling results

Zirconia is viewed as a material of exceptional resistance to amorphization by radiation damage, and consequently proposed as a candidate to immobilize nuclear waste and serve as an inert nuclear fuel matrix. Here, we perform molecular dynamics simulations of radiation damage in zirconia in the range of 0.1–0.5 MeV energies with account of electronic energy losses. We find that the lack of amorphizability co-exists with a large number of point defects and their clusters. These, importantly, are largely isolated from each other and therefore represent a dilute damage that does not result in the loss of long-range structural coherence and amorphization. We document the nature of these defects in detail, including their sizes, distribution, and morphology, and discuss practical implications of using zirconia in intense radiation environments.

36 MATERIALS SCIENCE↗

Global Shape and Ligand Binding Efficiency of the HIV-1-neutralizing Antibodies Differ from Those of Antibodies That Cannot Neutralize HIV-1

Asymmetric disposition of Fab arms in the structures solved for the broadly neutralizing monoclonal antibody (nmAb) IgG1 b12 raised the question of whether the unusual shape observed for b12 is common for all IgG1 mAbs or if there is a difference in the overall shape of nmAbs versus non-nmAbs. In this paper, we compared small angle x-ray scattering (SAXS) data-based models and limited proteolysis profiles of some IgG1 mAbs known to be having and lacking HIV-1 neutralizing potency. In non-nmAbs, the Fab arms were found to be symmetrically disposed in space relative to central Fc, but in most nmAbs, the Fab arms were asymmetrically disposed, as seen for IgG1 b12. The only exceptions were 2G12 and 4E10, where both Fab arms were closed above Fc, suggesting some Fab-Fc and/or Fab-Fab interaction in the nmAbs that constrained extension of the Fab-Fc linker. Interestingly, these observations were correlated with differential proteolysis profiles of the mAbs by papain. Under conditions when papain could cut both Fab arms of non-nmAbs, only one Fab arm could be removed from neutralizing ones (except for 2G12 and 4E10). Chromatography and small angle x-ray scattering results of papain-digested products revealed that 1) the Fab-Fc or Fab-Fab interactions in unliganded mAbs are retained in digested products, and 2) whereas anti-gp120 non-nmAbs could bind two gp120 molecules, nmAbs could bind only one gp120. Finally, additional experiments showed that except for 2G12 and 4E10, unopen shapes of nmAbs remain uninfluenced by ionic strength but can be reversibly opened by low pH of buffer accompanied by loss of ligand binding ability.

60 APPLIED LIFE SCIENCES↗

Dust Studies in DIII-D and TEXTOR

Studies of naturally occurring and artificially introduced carbon dust are conducted in DIII-D and TEXTOR. In DIII-D, dust does not present operational concerns except immediately after entry vents. Submicron sized dust is routinely observed using Mie scattering from a Nd:Yag laser. The source is strongly correlated with the presence of Type I edge localized modes (ELMs). Larger size (0.005-1 mm diameter) dust is observed by optical imaging, showing elevated dust levels after entry vents. Inverse dependence of the dust velocity on the inferred dust size is found from the imaging data. Direct heating of the dust particles by the neutral beam injection (NBI) and acceleration of dust particles by the plasma flows are observed. Energetic plasma disruptions produce significant amounts of dust. Large flakes or debris falling into the plasma may result in a disruption. Migration of pre-characterized carbon dust is studied in DIII-D and TEXTOR by introducing micron-size dust in plasma discharges. In DIII-D, a sample holder filled with {approx}30 mg of dust is introduced in the lower divertor and exposed to high-power ELMing H-mode discharges with strike points swept across the divertor floor. After a brief exposure ({approx}0.1 s) at the outer strike point, part of the dust is injected into the plasma, raising the core carbon density by a factor of 2-3 and resulting in a twofold increase of the radiated power. In TEXTOR, instrumented dust holders with 1-45 mg of dust are exposed in the scrape-off layer 0-2 cm radially outside of the last closed flux surface in discharges heated with neutral beam injection (NBI) power of 1.4 MW. At the given configuration of the launch, the dust did not penetrate the core plasma and only moderately perturbed the edge plasma, as evidenced by an increase of the edge carbon content.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Multiferroic ground states in free standing perovskite-based nanodots: a density functional theory study

In this work, we use density functional theory to investigate the possibility of polar and multiferroic states in free-standing, perovskite-based nanodots at the atomic limit of miniaturization: single unit cells with terminations which allow centro-symmetry. We consider both A-O and B-O 2 terminations for three families of nanodots: (i) A = Ba with B = Ti, Zr, and Hf; (ii) A = Ca and Sr with B = Ti; and (iii) A = Na and K with B = Nb. We find all A–O terminated dots to be non-polar and to exhibit cubic symmetry (except for K 8 NbO 6 ), regardless of the presence of ferroelectricity in the bulk. In contrast, all the B–O 2 terminated nanodots considered relax to a non-cubic ground state. Rather surprisingly, all of these structures exhibit polar ground states (except NaNb 8 O 12 ). We propose a new structural parameter, the cluster tolerance factor (CTF), to determine whether a particular chemistry will result in a polar ground state nanodot, analogous to the Goldschmidt factor for bulk ferroelectrics. In addition, we find that all A–O terminated (except Ca 8 TiO 6 ) and all polar B–O 2 terminated nanodots are magnetic, where none show magnetism in the bulk. As with bulk systems, multiferroicity in the B–O 2 terminated dots originates from separation between spin density in peripheral B atoms and polarity primarily caused by the off-center central A atom. Our findings stress that surface termination plays a crucial role in determining whether ferroelectricity is completely suppressed in perovskite-based materials at their limit of miniaturization.

36 MATERIALS SCIENCE↗

Optimization of Mn Doping in Group-IV-based Dilute Magnetic Semiconductors by Electronic Co-dopants

The percentage of substitutional doping of magnetic atoms (Mn) in group-IV-based dilute magnetic semiconductors (DMS) can be increased by co-doping with another conventional electronic dopant (e-dopant), as demonstrated from rst-principles calculations recently [Zhu et al., Phys. Rev. Lett. 100, 027205 (2008)]. Here, we report extensive theoretical investigations of the kinetic and thermodynamic characteristics of several co-doped systems including bulk Si and Ge as hosts and various group-III and group-V e-dopants. The main ndings are as follows: The n-p pairing of n-type e-dopants with p-type substitutional Mn is energetically stable in bulk Ge and Si. Mn atoms move from interstitial sites to substitutional sites easier (with lower kinetic barriers) in the presence of a neighboring n-type e-dopant. Magnetic coupling between two Mn atoms in bulk Ge oscillates between positive (ferromagnetic) and negative (antiferromagnetic) values with increasing Mn-Mn distance, but in Mn/As co-doped Ge the coupling parameter remains positive at all distances beyond nearest-neighbors and this qualitative dierence does not change with the doping level. For Mn doped Si, all coupling values except for the nearest neighbor one are positive and do not change much upon co-doping. We nd an unconventional magnetic anisotropy in the co-doped system, that is, the dependence of magnetic coupling on the relative positions of the magnetic ions and their neighboring e-dopants. We map the calculated magnetic coupling to a classical Heisenberg model and employ Monte Carlo simulations to estimate the Curie temperature (Tc). We nd that in Mn doped Ge no ferromagnetic order exists for Mn concentrations ranging from 3.13% to 6%. Instead, a spin-glass phase transition occurs at 5 K at 5% Mn doping. For Mn/As co-doped Ge, Tc increases nearly linearly with the Mn concentration and reaches 264 K at 5% Mn doping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Axion dark matter experiment: Run 1B analysis details

Searching for axion dark matter, the ADMX Collaboration acquired data from January to October 2018, over the mass range 2.81–3.31 μeV, corresponding to the frequency range 680–790 MHz. Using an axion haloscope consisting of a microwave cavity in a strong magnetic field, the ADMX experiment excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions at 90% confidence level and 100% dark matter density over this entire frequency range, except for a few gaps due to mode crossings. This paper explains the full ADMX analysis for run 1B, motivating analysis choices informed by details specific to this run.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast, high-resolution 3D dosimetry utilizing a novel optical-CT scanner incorporating tertiary telecentric collimation

This study introduces a charge coupled device (CCD) area detector based optical-computed tomography (optical-CT) scanner for comprehensive verification of radiation dose distributions recorded in nonscattering radiochromic dosimeters. Defining characteristics include: (i) a very fast scanning time of {approx}5 min to acquire a complete three-dimensional (3D) dataset, (ii) improved image formation through the use of custom telecentric optics, which ensures accurate projection images and minimizes artifacts from scattered and stray-light sources, and (iii) high resolution (potentially 50 {mu}m) isotropic 3D dose readout. The performance of the CCD scanner for 3D dose readout was evaluated by comparison with independent 3D readout from the single laser beam OCTOPUS-scanner for the same PRESAGE dosimeters. The OCTOPUS scanner was considered the 'gold standard' technique in light of prior studies demonstrating its accuracy. Additional comparisons were made against calculated dose distributions from the ECLIPSE treatment-planning system. Dose readout for the following treatments were investigated: (i) a single rectangular beam irradiation to investigate small field and very steep dose gradient dosimetry away from edge effects, (ii) a 2-field open beam parallel-opposed irradiation to investigate dosimetry along steep dose gradients, and (iii) a 7-field intensity modulated radiation therapy (IMRT) irradiation to investigate dosimetry for complex treatment delivery involving modulation of fluence and for dosimetry along moderate dose gradients. Dose profiles, dose-difference plots, and gamma maps were employed to evaluate quantitative estimates of agreement between independently measured and calculated dose distributions. Results indicated that dose readout from the CCD scanner was in agreement with independent gold-standard readout from the OCTOPUS-scanner as well as the calculated ECLIPSE dose distribution for all treatments, except in regions within a few millimeters of the edge of the dosimeter, where edge artifact is predominant. Agreement of line profiles was observed, even along steep dose gradients. Dose difference plots indicated that the CCD scanner dose readout differed from the OCTOPUSscanner readout and ECLIPSE calculations by {approx}10% along steep dose gradients and by {approx}5% along moderate dose gradients. Gamma maps (3% dose-difference and 3 mm distance-to-agreement acceptance criteria) revealed agreement, except for regions within 5 mm of the edge of the dosimeter where the edge artifact occurs. In summary, the data demonstrate feasibility of using the fast, high-resolution CCD scanner for comprehensive 3D dosimetry in all applications, except where dose readout is required close to the edges of the dosimeter. Further work is ongoing to reduce this artifact.

61 RADIATION PROTECTION AND DOSIMETRY↗

Simulation of large x-ray fields using independently measured source and geometry details

Purpose: Obtain an accurate simulation of the dose from the 6 and 18 MV x-ray beams from a Siemens Oncor linear accelerator by comparing simulation to measurement. Constrain the simulation by independently determining parameters of the treatment head and incident beam, in particular, the energy and spot size. Methods: Measurements were done with the treatment head in three different configurations: (1) The clinical configuration, (2) the flattening filter removed, and (3) the target and flattening filter removed. Parameters of the incident beam and treatment head were measured directly. Incident beam energy and spectral width were determined from the percent-depth ionization of the raw beam (as described previously), spot size was determined using a spot camera, and the densities of the flattening filters were determined by weighing them. Simulations were done with EGSnrc/BEAMnrc code. An asymmetric simulation was used, including offsets of the spot, primary collimator, and flattening filter from the collimator rotation axis. Results: Agreement between measurement and simulation was obtained to the least restrictive of 1% or 1 mm at 6 MV, both with and without the flattening filter in place, except for the buildup region. At 18 MV, the agreement was 1.5%/1.5 mm with the flattening filter in place and 1%/1 mm with it removed, except for in the buildup region. In the buildup region, the discrepancy was 2%/2 mm at 18 MV and 1.5%/1.5 mm at 6 MV with the flattening filter either removed or in place. The methodology for measuring the source and geometry parameters for the treatment head simulation is described. Except to determine the density of the flattening filter, no physical modification of the treatment head is necessary to obtain those parameters. In particular, the flattening filter does not need to be removed as was done in this work. Conclusions: Good agreement between measured and simulated dose distributions was obtained, even in the buildup region. The simulation was tightly constrained by independent measurements of parameters of the incident beam and treatment head. The method of obtaining the input parameters is described, and can be carried out on a clinical linear accelerator.

61 RADIATION PROTECTION AND DOSIMETRY↗

Validation of Varian TrueBeam electron phase–spaces for Monte Carlo simulation of MLC-shaped fields

Purpose: This work evaluates Varian’s electron phase–space sources for Monte Carlo simulation of the TrueBeam for modulated electron radiation therapy (MERT) and combined, modulated photon and electron radiation therapy (MPERT) where fields are shaped by the photon multileaf collimator (MLC) and delivered at 70 cm SSD. Methods: Monte Carlo simulations performed with EGSnrc-based BEAMnrc/DOSXYZnrc and PENELOPE-based PRIMO are compared against diode measurements for 5 × 5, 10 × 10, and 20 × 20 cm{sup 2} MLC-shaped fields delivered with 6, 12, and 20 MeV electrons at 70 cm SSD (jaws set to 40 × 40 cm{sup 2}). Depth dose curves and profiles are examined. In addition, EGSnrc-based simulations of relative output as a function of MLC-field size and jaw-position are compared against ion chamber measurements for MLC-shaped fields between 3 × 3 and 25 × 25 cm{sup 2} and jaw positions that range from the MLC-field size to 40 × 40 cm{sup 2}. Results: Percent depth dose curves generated by BEAMnrc/DOSXYZnrc and PRIMO agree with measurement within 2%, 2 mm except for PRIMO’s 12 MeV, 20 × 20 cm{sup 2} field where 90% of dose points agree within 2%, 2 mm. Without the distance to agreement, differences between measurement and simulation are as large as 7.3%. Characterization of simulated dose parameters such as FWHM, penumbra width and depths of 90%, 80%, 50%, and 20% dose agree within 2 mm of measurement for all fields except for the FWHM of the 6 MeV, 20 × 20 cm{sup 2} field which falls within 2 mm distance to agreement. Differences between simulation and measurement exist in the profile shoulders and penumbra tails, in particular for 10 × 10 and 20 × 20 cm{sup 2} fields of 20 MeV electrons, where both sets of simulated data fall short of measurement by as much as 3.5%. BEAMnrc/DOSXYZnrc simulated outputs agree with measurement within 2.3% except for 6 MeV MLC-shaped fields. Discrepancies here are as great as 5.5%. Conclusions: TrueBeam electron phase–spaces available from Varian have been implemented in two distinct Monte Carlo simulation packages to produce dose distributions and outputs that largely reflect measurement. Differences exist in the profile shoulders and penumbra tails for the 20 MeV phase–space off-axis and in the outputs for the 6 MeV phase–space.

07 ISOTOPE AND RADIATION SOURCES↗

WE-D-204-00: Session in Memory of Franca Kuchnir: Excellence in Medical Physics Residency Education

Speakers in this session will present overview and details of a specific rotation or feature of their Medical Physics Residency Program that is particularly exceptional and noteworthy. The featured rotations include foundational topics executed with exceptional acumen and innovative educational rotations perhaps not commonly found in Medical Physics Residency Programs. A site-specific clinical rotation will be described, where the medical physics resident follows the physician and medical resident for two weeks into patient consultations, simulation sessions, target contouring sessions, planning meetings with dosimetry, patient follow up visits, and tumor boards, to gain insight into the thought processes of the radiation oncologist. An incident learning rotation will be described where the residents learns about and practices evaluating clinical errors and investigates process improvements for the clinic. The residency environment at a Canadian medical physics residency program will be described, where the training and interactions with radiation oncology residents is integrated. And the first month rotation will be described, where the medical physics resident rotates through the clinical areas including simulation, dosimetry, and treatment units, gaining an overview of the clinical flow and meeting all the clinical staff to begin the residency program. This session will be of particular interest to residency programs who are interested in adopting or adapting these curricular ideas into their programs and to residency candidates who want to learn about programs already employing innovative practices. Learning Objectives: To learn about exceptional and innovative clinical rotations or program features within existing Medical Physics Residency Programs. To understand how to adopt/adapt innovative curricular designs into your own Medical Physics Residency Program, if appropriate.

60 APPLIED LIFE SCIENCES↗