Search NASA⌕ Search

SEARCH · Search NASA

Results for “facility development”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Nuclear Material Monitoring in Molten Salt Systems using Cyclic Voltammetry

As designs for the next generation of nuclear power plants and reprocessing facilities develop, molten salt based systems are receiving increasing attention as fuel containment, cooling and reprocessing media. Traditionally, aqueous systems for power production and fuel reprocessing are associated with well-developed methods for the monitoring and accountancy of nuclear material. Many of these techniques are proving insufficient in providing the same information in molten salt systems. The International Atomic Energy Agency (IAEA) has called for the continued evaluation of advanced measurement techniques in systems such as molten salt as part of the Generation IV International Forum (GIF) and International Project on Innovative Nuclear Reactors and Fuel Cycles (INPRO). Cyclic voltammetry (CV) is an electrochemical technique that offers promising applications in molten salt systems for the in situ monitoring of nuclear material. A technique such as CV offers a method for monitoring nuclear material in a system relying on molten salt for power production, cooling or reprocessing. Cyclic voltammetry has been shown to provide information regarding the diffusion of electroactive species in molten salt. Once a diffusion coefficient data base is assembled, CV can be performed on molten salt systems to determine concentrations of species in situ.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Lessons Learned at the Idaho National Laboratory for the Entry into Force of the U.S. Additional Protocol

For a number of years, the Idaho National Laboratory (INL) has been preparing for the entry into force of the U.S. Additional Protocol (AP). These preparations included attending training, participating in tabletop exercises, preparing draft declarations, developing INL-specific guidance documents, preparing for and hosting a mock complementary access visit, and preparing declarations for official submittal. All of these activities, the training materials, and software developed by other U.S. DOE national laboratories (PNNL, ORNL, LANL, and BNL) were very helpful in preparing for the entry into force of the AP. As with any endeavor of this size and complexity, however, there are always instances where even the best preparations and advanced planning do not anticipate every challenge. As the DOE's lead nuclear energy research and development facility, the INL faced many unique challenges. The majority of research conducted at the INL is nuclear fuel cycle related, most of which is not protected by the National Security Exclusion. This paper describes the lessons learned from the INL’s experience of preparing for the entry into force of the AP, specifically how translating and implementing general principles into actual activities proved to be one of many challenges, and provides general suggestions on how to respond effectively and efficiently to routine annual data calls and other AP requests.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Modular test facility for HTS insert coils

The final beam cooling stages of a Muon Collider may require DC solenoid magnets with magnetic fields in the range of 40-50 T. In this paper we will present a modular test facility developed for the purpose of investigating very high field levels with available 2G HTS superconducting materials. Performance of available conductors is presented, together with magnetic calculations and evaluation of Lorentz forces distribution on the HTS coils. Finally a test of a double pancake coil is presented.

43 PARTICLE ACCELERATORS↗

Development of a facility for large-scale testing of multistory buildings

Current experimental research pertaining to response of structures subjected to lateral loads such as strong winds or earthquake motions is limited to either tests of single structural components or small scale multistory structures. The feasibility of developing a facility where large scale multistory structures could be loaded to failure is discussed. The test facility would consist of a series of hydraulic actuators mounted on reaction frames currently in use at the Marshall Space Flight Center for structural testing of spacecraft components. The actuators would be controlled from signals computed by an on-line analysis of measured data. This method of loading could be used to simulate inertial forces resisted by a structure behaving in the non linear range of response subjected to motion at the base or to impulses along the height as would occur during a strong earthquake or wind.

Abrams, D. P.↗

Overview of Fish Passage Facilities at Hydropower Developments across the Conterminous United States

This dataset contains geo-referenced information on the presence and types of fish passage facilities at hydropower developments across the conterminous United States (CONUS) presented in the ORNL Hydropower Fish Passage Database Webmap (https://www.ornl.gov/project/quantifying-national-fish-passage-data/webmap). It was developed through collaborative partnerships with fish passage engineers and biologists at both the US Fish and Wildlife Service (USFWS) and the National Marine Fisheries Service (NMFS), and hydropower experts at the Low Impact Hydropower Institute (LIHI). Information contained within this dataset has been provided by many different sources, including State and Federal resource management agencies, non-governmental organizations, hydropower industry members, and published datasets=. This dataset is intended to provide a high-level overview of the distribution of fish passage infrastructure at hydropower developments across CONUS; a more comprehensive database is anticipated to be released later in 2025. This dataset contains one data file in comma-separate (*.csv) format and the information within it was last updated on 24 March 2025.

13 HYDRO ENERGY↗

Development of an Industry Dynamometer/Spin Test Facility--Equipment Only: Cooperative Research and Development Final Report, CRADA Number CRD-05-164

The Department of Energy/National Renewable Energy Laboratory (DOE/NREL) owns and operates a megawatt-scale dynamometer used for testing wind turbine drive trains up to 1.5 megawatt (MW) in rated capacity. At this time, this unit is the only unit of its type in the United States, available for use by the American Wind Industry. Currently this dynamometer is heavily backlogged and unavailable to provide testing needed by various wind industry members. DOE/NREL is in possession of two critical pieces of equipment that may be used to develop an alternative Dynamometer facility, but does not have the funds or other resources necessary to develop such a facility. The Participant possesses complimentary facilities and infrastructure that when combined with the NREL equipment can create such a test facility. The Participant is also committed to expending funds to develop and operate such a facility to the subsequent benefit of the Wind Industry and DOE Wind Energy program. In exchange for DOE/NREL providing the critical equipment, the Participant will grant DOE/NREL a minimum of 90 days of testing time per year in the new facility while incurring no facilities fees.

17 WIND ENERGY↗

Development of a facility for high-precision irradiation of cells with carbon ions

Purpose: Compared to photons, using particle radiation in radiotherapy reduces the dose and irradiated volume of normal tissues, potentially reducing side effects. The biological effect of dose deposited by particles such as carbon ions, however, differs from that of dose deposited by photons. The inaccuracy in models to estimate the biological effects of particle radiation remains the most important source of uncertainties in particle therapy. Improving this requires high-precision studies on biological effects of particle radiation. Therefore, the authors aimed to develop a facility for reproducible and high-precision carbon-ion irradiation of cells in culture. The combined dose nonuniformity in the lateral and longitudinal direction should not exceed {+-}1.5%. Dose to the cells from particles than other carbon ions should not exceed 5%. Methods: A uniform lateral dose distribution was realized using a single scatter foil and quadrupole magnets. A modulator wheel was used to create a uniform longitudinal dose distribution. The choice of beam energy and the optimal design of these components was determined using GEANT4 and SRIM Monte Carlo simulations. Verification of the uniformity of the dose distribution was performed using a scintillating screen (lateral) and a water phantom (longitudinal). The reproducibility of dose delivery between experiments was assessed by repeated measurements of the spatial dose distribution. Moreover, the reproducibility of dose-response measurements was tested by measuring the survival of irradiated HEK293 cells in three independent experiments. Results: The relative contribution of dose from nuclear reaction fragments to the sample was found to be <5% when using 90 MeV/u carbon ions. This energy still allows accurate dosimetry conforming to the IAEA Report TRS-398, facilitating comparison to dose-effect data obtained with other radiation qualities. A 1.3 mm long spread-out Bragg peak with a diameter of 30 mm was created, allowing the irradiation of cell samples with the specified accuracy. Measurements of the transverse and longitudinal dose distribution showed that the dose variation over the sample volume was {+-}0.8% and {+-}0.7% in the lateral and longitudinal directions, respectively. The track-averaged LET of 132{+-}10 keV/{mu}m and dose-averaged LET of 189{+-}15 keV/{mu}m at the position of the sample were obtained from a GEANT4 simulation, which was validated experimentally. Three separately measured cell-survival curves yielded nearly identical results. Conclusions: With the new facility, high-precision carbon-ion irradiations of biological samples can be performed with highly reproducible results.

60 APPLIED LIFE SCIENCES↗

PERLE: A novel facility for ERL development and applications in multi-turn configuration and high-power regime

The development of ERLs has been recognized as one of the five main pillars of accelerators R&D in support of the European Strategy for Particle Physics (ESPP). The international panel in charge of the ERL Roadmap definition recognized PERLE project as “a central part of the roadmap for the development of energy-recovery linacs”, with milestones to be achieved by the next ESPP in 2026. PERLE project is aiming at the construction of a novel ERL facility for the development and application of the energy recovery technique in multi-turn configuration, high current and large energy regime. It will operate in a 3-turns mode, first at 250 MeV, then upgraded to 500 MeV with 20mA beam current. Such challenging parameters make PERLE a unique multi-turn ERL facility operating at an unexplored operational power regime (10MW), studying and validating a broad range of accelerator phenomena, paving the way for the future larger scale ERLs. PERLE will be the necessary demonstrator for the future HEP machine (LHeC / FCC-eh), with which it shares the same technological choices and beam parameters. Furthermore, PERLE opens a new frontier for the physics of “the electromagnetic probe”. It will be the first ERL dedicated to Nuclear Physics for studying the eN interaction with radioactive nuclei. Here we will report on the project status, introduce the main ongoing achievements and describe the staged strategy we will adopt toward the construction of PERLE machine at its nominal performances.

Kaabi, Walid↗

Identifying Controlling Variables Related to Mercury Vapor Concentrations in Legacy Facilities: SRNL Technology Development For D&D

A suite of sensor packages has been installed in the Alpha-4 facility at Y-12 and preliminary data analysis to isolate the controlling variables has been performed after two months of data collection. In line with the conceptual model presented in Section 2.0, the preliminary analysis has demonstrated that temperature, barometric pressure, and relative humidity are the key controlling variables for mercury vapor releases within the building. The data analysis will continue to explore these controlling variables across the next several months to capture a more complete picture of the annual change in meteorological conditions at Y-12.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Drive-train dynamics technology - State-of-the-art and design of a test facility for advanced development

A program for the development and verification of drive-train dynamic technology is described along with its basis and the results expected from it. A central feature of this program is a drive-train test facility designed for the testing and development of advanced drive-train components, including shaft systems, dampers, and couplings. Previous efforts in designing flexible dynamic drive-train systems are reviewed, and the present state of the art is briefly summarized. The design of the test facility is discussed with major attention given to the formulation of the test-rig concept, dynamic scaling of model shafts, and the specification of design parameters. Specific efforts envisioned for the test facility are briefly noted, including evaluations of supercritical test shafts, stability thresholds for various sources and types of instabilities that can exist in shaft systems, effects of structural flexibility on the dynamic performance of dampers, and methods for vibration control in two-level and three-level flexible shaft systems.

Badgley, R. H.↗

Development of robotics facility docking test hardware

Design and fabricate test hardware for NASA's George C. Marshall Space Flight Center (MSFC) are reported. A docking device conceptually developed was fabricated, and two docking targets which provide high and low mass docking loads were required and were represented by an aft 61.0 cm section of a Hubble space telescope (ST) mockup and an upgrading of an existing multimission modular spacecraft (MSS) mockup respectively. A test plan is developed for testing the hardware.

Loughead, T. E.↗

Development of a facility using robotics for testing automation of inertial instruments

The Integrated Robotics System Simulation (ROBSIM) was used to evaluate the performance of the PUMA 560 arm as applied to testing of inertial sensors. Results of this effort were used in the design and development of a feasibility test environment using a PUMA 560 arm. The implemented facility demonstrated the ability to perform conventional static inertial instrument tests (rotation and tumble). The facility included an efficient data acquisitions capability along with a precision test servomechanism function resulting in various data presentations which are included in the paper. Analysis of inertial instrument testing accuracy, repeatability and noise characteristics are provided for the PUMA 560 as well as for other possible commercial arm configurations. Another integral aspect of the effort was an in-depth economic analysis and comparison of robot arm testing versus use of contemporary precision test equipment.

Greig, Joy Y.↗

Bright x-ray stainless steel K-shell source development at the National Ignition Facility

High x-ray conversion efficiency (XRCE) K-shell sources are being developed for high energy density experiments for use as backlighters and for the testing of materials exposed to high x-ray fluxes and fluences. Recently, sources with high XRCE in the K-shell x-ray energy range of iron and nickel were investigated at the National Ignition Facility (NIF). The x-ray conversion efficiency in the 5–9 keV spectral range was determined to be 6.8% ± 0.3%. These targets were 4.1 mm diameter, 4 mm tall hollow epoxy tubes having a 50 μm thick wall supporting a tube of 3 to 3.5 μm thick stainless steel. The NIF laser deposited ∼460 kJ of 3ω light into the target in a 140 TW, 3.3 ns square pulse. The absolute x-ray emission of the source was measured by two calibrated Dante x-ray spectrometers. Time resolved images filtered for the Fe K-shell were recorded to follow the heating of the target. Time integrated high-resolution spectra were recorded in the K-shell range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a CCD array as an imaging detector for advanced X-ray astrophysics facilities

The development of a charge coupled device (CCD) X-ray imager for a large aperture, high angular resolution X-ray telescope is discussed. Existing CCDs were surveyed and three candidate concepts were identified. An electronic camera control and computer interface, including software to drive a Fairchild 211 CCD, is described. In addition a vacuum mounting and cooling system is discussed. Performance data for the various components are given.

Schwartz, D. A.↗

An overview of the facilities, activities, and developments at the University of North Texas Ion Beam Modification and Analysis Laboratory (IBMAL)

The Ion Beam Modification and Analysis Laboratory (IBMAL) at the University of North Texas includes several accelerator facilities with capabilities of producing a variety of ion beams from tens of keV to several MeV in energy. The four accelerators are used for research, graduate and undergraduate education, and industrial applications. The NEC 3MV Pelletron tandem accelerator has three ion sources for negative ions: He Alphatross and two different SNICS-type sputter ion sources. Presently, the tandem accelerator has four high-energy beam transport lines and one low-energy beam transport line directly taken from the negative ion sources for different research experiments. For the low-energy beam line, the ion energy can be varied from {approx}20 to 80 keV for ion implantation/modification of materials. The four post-acceleration beam lines include a heavy-ion nuclear microprobe; multi-purpose PIXE, RBS, ERD, NRA, and broad-beam single-event upset; high-energy ion implantation line; and trace-element accelerator mass spectrometry. The NEC 3MV single-ended Pelletron accelerator has an RF ion source mainly for hydrogen, helium and heavier inert gases. We recently installed a capacitive liner to the terminal potential stabilization system for high terminal voltage stability and high-resolution microprobe analysis. The accelerator serves a beam line for standard RBS and RBS/C. Another beamline for high energy focused ion beam application using a magnetic quadrupole lens system is currently under construction. This beam line will also serve for developmental work on an electrostatic lens system. The third accelerator is a 200 kV Cockcroft-Walton accelerator with an RF ion source. The fourth accelerator is a 2.5 MV Van de Graaff accelerator, which was in operation for last several decades is currently planned to be used mainly for educational purpose. Research projects that will be briefly discussed include materials synthesis/modification for photonic, electronic, and magnetic applications, surface sputtering and micro-fabrication of materials, development of high-energy ion microprobe systems, and educational and outreach activities.

43 PARTICLE ACCELERATORS↗