Search NASA⌕ Search

SEARCH · Search NASA

Results for “feed - forward”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Effects of Blending and In-Tank Pretreatment on Direct Feed Hanford High Level Waste Vitrification - 18434

A direct feed high level waste (DFHLW) option is under consideration for early operations of the Hanford Tank Waste Treatment and Immobilization Plant (WTP). In this option, the Pretreatment Facility would be bypassed in order to support an earlier start-up of the HLW Vitrification Facility. For HLW, this would mean that ultrafiltration and caustic leaching that would otherwise have been performed either would not be performed or would be replaced by interim pretreatment functions such as in-tank washings. These changes could result in higher aluminum contents, higher chromium contents, higher fractions of supernate, and lower solids contents in the HLW feed. As a result, glass formulations and downstream vitrification operations will be impacted. In the present work, we investigate the effects of various waste blending and in-tank pretreatment scenarios on DFHLW glass waste loadings, canister counts, and processing rates. Eleven source tanks and five waste groups were selected for the studies of waste blending. In addition, the five waste groups selected were the subjects of an in-tank pretreatment study. Glass property-composition models and melter test data were used to calculate waste loadings, canister counts, processing rates, and treatment durations for a range of DFHLW scenarios. The processing scenarios were defined by the types of waste blending and in-tank pretreatment that were assumed. Blending cases were evaluated that ranged between the 'No Blend' and 'Total Blend' extremes and included pairwise blending (blending of two source tanks, either completely or in various proportions) and macro-batches formed from various combinations of the source tanks. Over 36,000 possible pairwise blending scenarios were evaluated and an optimal retrieval/blending sequence was identified. The waste loading of this optimal sequence is within 0.03 wt% of the 'Total Blend' case. Further, a total of 38 retrieval sequences were identified that have waste loadings within 0.1 wt% of the 'Total Blend' case. To evaluate the effects of in-tank pretreatment, an in-tank wash/settle/decant process was assumed and tank-specific wash factors were employed. Washing of the macro-batch blends gave a general increase in HLW loading, decrease in canister count, and decrease in glass yield. Glass yields are towards the low end of the values expected for the WTP, which could lead to lower than nominal glass production rates. The waste loading increases and canister count reductions with washing were small for two of the wastes indicating that direct treatment of the unwashed waste may be practical. For wastes that are relatively low in sulfate and halides, excessive washing is counterproductive. The results highlight the importance of maintaining high solids content in the HLW feed to maintain glass production rates. The results also illustrate that the optimum washing strategy will need to be evaluated on a tank-to-tank basis. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radioactive Test Platform Demonstrating the Direct Feed Low-Activity Waste Process at Hanford - 18628

The Hanford Site is implementing a phased process for treating liquid legacy radioactive waste. The process is called the Direct Feed Low-Activity Waste process (DFLAW). The DFLAW includes a filtration and ion-exchange unit in the Low-Activity Waste Pretreatment System (LAWPS) that removes solids and cesium. This pretreat feed is then sent to a vitrification facility where glass-forming solids are added and the waste is turned into glass in a melter. The melter off-gas liquid condensate is evaporated in the Effluent Management Facility (EMF), with the concentrate recycled back into the feed. A laboratory-scale test platform has been built to test various aspects of the DFLAW process using samples of actual radioactive waste. The current platform represents four of the major unit operations: filtration, ion-exchange, vitrification, and off-gas condensation. A lab scale EMF is being designed to supplement the current platform. The platform is expandable to add any or all unit operations. The radioactive test platform has three missions. The first is simply to demonstrate the DFLAW process with real waste. A second objective is to address flowsheet gaps and opportunities, some of which require testing with real waste. Some gaps and opportunities include addressing the fate of mercury in the flowsheet, evaluating salt and aluminum precipitation, and proving new glass formulations with real waste. A third objective of the radioactive test platform is to demonstrate or evaluate future operations and alternative flowsheets. Some of the future operations evaluated will be the life expectancy of the resin in real waste, resin sampling, evaluation of how waste affects melter throughput, and grouting various primary and secondary waste streams. The radioactive test platform is therefore a crucial tool for verifying and optimizing the DFLAW flowsheet at Hanford with real waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Recovery from loss of reductant feed to a U/Pu separation contactor, magnox reprocessing plant, Sellafield - 14217

Following a revealed sustained loss of reductant feed to the Primary Separation 4 (PS4) U/Pu separation contactor in the Magnox Reprocessing Plant in 2014 the solvent extraction cycles were safely shutdown. However, initial mass balance calculations indicated that over four times the typical mass of Pu could be present in PS4. Due to the loss of reductant feed, much of this Pu was expected to be in the solvent phase of Tributyl Phosphate and Odourless Kerosene (TBP/OK) where it would be difficult to observe with the neutron monitors located under PS4. Samples were taken of the solvent in PS4 which confirmed the presence of Pu in solvent; normally almost all of the Pu in PS4 is in the aqueous phase. The volume ratio of solvent to aqueous in the PS4 contactor is high. This meant that simply re-dosing PS4 with reductant could not be supported as a recovery option due to the potential to realise high Pu concentrations in the aqueous phase. This paper details the recovery options which were considered and the ultimate decision to recover PS4 using Gadolinium (Gd) poisoning and Gd-dosed reductant feeds. The recovery included: - The need to consider the impact of Gd poisoning on monitoring of the recovery with the PS4 neutron monitors; - Close support from criticality safety personnel on the plant at all times during the recovery; - Production of operator aids and short fit for purpose safety documentation to assist with the recovery. The recovery of PS4 proceeded safely and smoothly. There were no losses of Pu to raffinate streams despite the prolonged shutdown. The plant was then safely rundown to flush out residual Pu and Gd. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Feeding of the 1 1/2- isomers in stable Ir and Au isotopes

Excited states were studied and absolute partial {gamma}-ray cross sections were measured using the ({eta}, {eta}'{gamma}) reaction in {sup 191}Ir, {sup 193}Ir and {sup 197}Au. A Compton-suppressed germanium-detector array (GEANIE) for {gamma}-ray spectroscopy and the broad-spectrum pulsed neutron source of the Los Alamos Neutron Science Center's WNR facility were used for the measurement. The energy of the incident neutrons was determined using the time-of-flight technique. Absolute partial {gamma}-ray cross sections were measured up to incident neutron energy of 20 MeV for several transitions feeding directly the 1 1/2- isomers and ground states in {sup 191}Ir, {sup 193}Ir and {sup 197}Au. The feeding of the 1 1/2- isomers, which originate from the odd proton occupying the h{sub 1 1/2} orbital, was found for the three targets to be very similar and increasing relative to the feeding of the corresponding ground state with increasing neutron energy up to E{sub n} {approx} 10 MeV. Above this neutron energy the opening of the (n, 2{sub n}) reaction channel strongly affects the population of the isomers and leads to a decrease of their relative population compared to the population of the ground states. The experimental results are compared with theoretical predictions from the GNASH reaction model calculation implementing a version of the spin distribution for the pre-equilibrium reaction piece with either a compound nucleus spin distribution (CN-GNASH) or a Feshbach-Kerman-Koonin (FKK-GNASH) quantum mechanical spin distribution. The effects of the spin cutoff parameter values on the population of states are examined. Evidence is presented that FKK-GNASH provides a description of the experimental data that mitigates the need for adjustment of the level density parameter to fit the data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

EFFECT OF MELTER-FEED-MAKEUP ON VITRIFICATION PROCESS

Increasing the rate of glass processing in the Hanford Tank Waste Treatment and Immobilization Plant (WTP) will allow shortening the life cycle of waste cleanup at the Hanford Site. While the WTP melters have approached the limit of increasing the rate of melting by enhancing the heat transfer rate from molten glass to the cold cap, a substantial improvement can still be achieved by accelerating the feed-to-glass conversion kinetics. This study investigates how the feed-to-glass conversion process responds to the feed makeup. By identifying the means of control of primary foam formation and silica grain dissolution, it provides data needed for a meaningful and economical design of large-scale experiments aimed at achieving faster melting.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Minimum reflux calculation for multicomponent distillation in multi‐feed, multi‐product columns: Mathematical model

Abstract Multi‐feed, multi‐product distillation columns are ubiquitous in multicomponent distillation systems. The minimum reflux ratio of a distillation column is directly related to its energy consumption and capital cost. Thus, it is a key parameter for distillation systems design, operation, and comparison. In this series, we present the first accurate shortcut based algorithmic method to determine the minimum reflux condition for any general multi‐feed, multi‐product (MFMP) distillation column separating any ideal multicomponent mixture. The classic McCabe‐Thiele or Underwood method is a special case of this general approach. Compared with existing techniques, this method does not involve any rigorous tray‐by‐tray calculation, nor does it require guessing of key components. In this first part of the series, we present the mathematical model for a general MFMP column, derive constraints for feasible separation and minimum reflux condition, discuss their geometric interpretations, and present an illustrative example to demonstrate the effectiveness of our approach.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Inferring pesticide toxicity to honey bees from a field‐based feeding study using a colony model and Bayesian inference

Abstract Honey bees are crucial pollinators for agricultural crops but are threatened by a multitude of stressors including exposure to pesticides. Linking our understanding of how pesticides affect individual bees to colony‐level responses is challenging because colonies show emergent properties based on complex internal processes and interactions among individual bees. Agent‐based models that simulate honey bee colony dynamics may be a tool for scaling between individual and colony effects of a pesticide. The U.S. Environmental Protection Agency (USEPA) and U.S. Department of Agriculture (USDA) are developing the VarroaPop + Pesticide model, which simulates the dynamics of honey bee colonies and how they respond to multiple stressors, including weather, Varroa mites, and pesticides. To evaluate this model, we used Approximate Bayesian Computation to fit field data from an empirical study where honey bee colonies were fed the insecticide clothianidin. This allowed us to reproduce colony feeding study data by simulating colony demography and mortality from ingestion of contaminated food. We found that VarroaPop + Pesticide was able to fit general trends in colony population size and structure and reproduce colony declines from increasing clothianidin exposure. The model underestimated adverse effects at low exposure (36 µg/kg), however, and overestimated recovery at the highest exposure level (140 µg/kg), for the adult and pupa endpoints, suggesting that mechanisms besides oral toxicity‐induced mortality may have played a role in colony declines. The VarroaPop + Pesticide model estimates an adult oral LD 50 of 18.9 ng/bee (95% CI 10.1–32.6) based on the simulated feeding study data, which falls just above the 95% confidence intervals of values observed in laboratory toxicology studies on individual bees. Overall, our results demonstrate a novel method for analyzing colony‐level data on pesticide effects on bees and making inferences on pesticide toxicity to individual bees.

59 BASIC BIOLOGICAL SCIENCES↗

Pediatric Enteric Feeding Techniques: Insertion, Maintenance, and Management of Problems

Enteral feeding is considered a widespread, well-accepted means of delivering nutrition to adults and children who are unable to consume food by mouth or who need support in maintaining adequate nutrition for a variety of reasons, including acute and chronic disease states. Delivery of enteral feeding to nutritionally deprived patients may be achieved by several means. In this article, the indications and insertion of enteral access in children will be reviewed. In addition, common complications and management of problems will be discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A method for including external feed in depletion calculations with CRAM and implementation into ORIGEN

A method for including external feed with polynomial time dependence in depletion calculations with the Chebyshev Rational Approximation Method (CRAM) is presented and the implementation of CRAM to the ORIGEN module of the SCALE suite is described. In addition to being able to handle time-dependent feed rates, the new solver also adds the capability to perform adjoint calculations. Results obtained with the new CRAM solver and the original depletion solver of ORIGEN are compared to high precision reference calculations, which shows the new solver to be orders of magnitude more accurate. Lastly, in most cases, the new solver is up to several times faster due to not requiring similar substepping as the original one.

97 MATHEMATICS AND COMPUTING↗

Insights from FEED studies for retrofitting existing fossil power plants with carbon capture technology

Recent United States Department of Energy (DOE) sponsored front-end engineering design (FEED) studies for retrofitting existing fossil-fueled power plants with state-of-the-art carbon capture technology contain previously overlooked real-world design considerations for near-term deployment of carbon capture. Insights from examining seven recently published FEED study reports are summarized in this paper. This includes a discussion of the design, performance, and cost implications associated with (1) location-specific considerations such as water availability, land availability, and accessibility; (2) host-plant-specific factors such as flue gas specifications, allowable degree of integration between the capture system and host plant, and operational mode; and (3) miscellaneous factors such as market conditions, permitting requirements, and business case incentives. In conclusion, this manuscript highlights (1) water availability as a key design and cost driver, with host plant steam extraction increasing capture system cooling water availability, (2) modularization and constructability impacts on the number of capture trains, (3) the impacts of host plant operational mode and capacity factor on the business case for installing capture, and (4) the merit of continued research, development, and demonstration efforts addressing steam extraction, host plant tie-in at the stack, solvent reclamation and air emissions control.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Enteral Feeding During Chemoradiotherapy for Advanced Head-and-Neck Cancer: A Single-Institution Experience Using a Reactive Approach

Purpose: The optimal method for providing enteral nutrition to patients with head-and-neck cancer is unclear. The purpose of the present study was to evaluate the safety and efficacy of our reactive policy, which consists of the installation of a nasogastric (NG) feeding tube only when required by the patient's nutritional status. Methods and Materials: The records of all patients with Stage III and IV head-and-neck cancer treated with concomitant chemotherapy and radiotherapy between January 2003 and December 2006 were reviewed. The overall and disease-free survival rates were estimated using the Kaplan-Meier method and compared with the log-rank test. Results: The present study included 253 patients, and the median follow-up was 33 months. At 3 years, the estimated overall survival and disease-free survival rate was 82.8% and 77.8%, respectively, for the whole population. No survival difference was observed when the patients were compared according to the presence and absence of a NG tube or stratified by weight loss quartile. The mean weight loss during treatment for all patients was 10.4%. The proportion of patients requiring a NG tube was 49.8%, and the NG tube remained in place for a median duration of 40 days. No major complications were associated with NG tube installation. Only 3% of the patients were still dependent on enteral feeding at 6 months. Conclusion: These results suggest that the use of a reactive NG tube with an interdisciplinary team approach is a safe and effective method to manage malnutrition in patients treated with concomitant chemotherapy and radiotherapy for head-and-neck cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A reduced-order model of concentration polarization in reverse osmosis systems with feed spacers

Feed spacers in reverse osmosis systems generate complex fluid flows that limit computational fluid dynamics (CFD) simulations to small length and time scales. That limits our ability to simulate mineral scaling and other membrane fouling phenomena, which occur over longer length and time scales. Thus motivated, we develop a reduced model that replaces the CFD simulation of the velocity field with an analytical model that mimics spacers. This focuses the remaining numerical effort on simulating the advection–diffusion equation governing solute transport. We motivate and validate the model with CFD simulations and bench-scale experiments of spacer filaments in three different arrangements, including cases of unsteady vortex shedding. We show that the model produces a roughly 10,000-fold speedup compared to CFD, and accurately reproduces CFD predictions of not only the average and maximum concentrations, but also the local concentration distribution along the membrane. Here, we also demonstrate the model for simulating a feed channel with a length-to-height ratio of 200. The model provides a simple testbed for exploratory studies of multispecies transport, precipitation, and membrane fouling phenomena for which simulating spacers is often prohibitive.

Computational fluid dynamics↗

Dynamic force and stability prediction for milling using feed rate scheduling software and time-domain simulation

This paper describes: 1) the use of feed rate scheduling software to predict the radial depth of cut variation for three-axis milling toolpaths and; 2) the use of the radial depth profile in a time-domain simulation to predict dynamic cutting forces. The time-domain simulation, which also includes the tool tip frequency response functions and force model (which relates the cutting force components to the chip geometry) as inputs, enables dynamic force profiles to be predicted and parameter combinations that cause chatter to be identified. A ramp geometry is selected that provides constantly varying radial depth and force predictions are completed at multiple axial depths for comparison to measured forces. Both stable and unstable (chatter) milling conditions were observed with good agreement between time-domain simulation and measurement results. The value of combining the feed rate scheduling software and time-domain simulation is demonstrated.

42 ENGINEERING↗

Erythroneura lawsoni abundance and feeding injury levels are influenced by foliar nutrient status in intensively managed American sycamore.

Abstract 1 Abundance and feeding injury of the leafhopper Erythroneura lawsoni Robinson was measured in an intensively-managed American sycamore Platanus occidentalis L. plantation. Trees were planted in spring 2000 in a randomized complete block design, and received one of three annual treatments: (i) fertilization (120 kg N/ha/year); (ii) irrigation (3.0 cm/week); (iii) fertilization + irrigation; or (iv) control (no treatment). 2 Foliar nutrient concentrations were significantly influenced by the treatments because only sulphur and manganese levels were not statistically greater in trees receiving fertilization. 3 Over 116 000 E. lawsoni were captured on sticky traps during the study. Leafhopper abundance was highest on nonfertilized trees for the majority of the season, and was positively correlated with foliar nutrient concentrations. Significant temporal variation in E. lawsoni abundance occurred, suggesting five discrete generations in South Carolina. 4 Significant temporal variation occurred in E. lawsoni foliar injury levels, with the highest injury ratings occurring in late June and August. Foliar injury was negatively correlated with foliar nutrient content, and higher levels of injury occurred more frequently on nonfertilized trees. 5 The results obtained in the present study indicated that increased E. lawsoni abundance occurred on trees that did not receive fertilization. Nonfertilized trees experienced greater foliar injury, suggesting that lower foliar nutrient status may have led to increased levels of compensatory feeding.

60 APPLIED LIFE SCIENCES↗

Developing Load Cell Monitoring on the Mock UF 6 Feed and Withdrawal System

A proof-of-concept load cell monitoring system has been developed for the Mock Feed and Withdrawal (F&W) System at Oak Ridge National Laboratory (ORNL). This system leverages industry-standard commercial off-the-shelf (COTS) hardware and software in a modular and scalable design. The Mock F&W System was designed to simulate operations at a uranium hexafluoride (UF 6 ) gas centrifuge enrichment plant F&W area. It provides a test bed for process-monitoring technologies. Water, used as a surrogate for UF 6 , is pumped from three feed tanks, through a process surge tank, and is then cut between two tails tanks and three product tanks. The weight of the each tank is continuously monitored using a load cell monitoring system. In addition to the F&W stations, large and small accountancy stations are monitored. The Mock F&W System allows ORNL to test and evaluate capabilities of industry-standard process monitoring hardware and software. A variety of commonly used weighing indicators are connected to the load cells to monitor the weight at each station. These weighing indicators are representative of the types likely found in operating facilities. A data center modeled after those currently used for international safeguards was installed to collect and manage the weight data. This data center provides a robust and flexible test bed for testing and developing software solutions. COTS software packages that leverage industry-standard communication protocols provide a data flow architecture that is modular, interoperable, and scalable. One software package provides communication drivers to collect the raw weight data from the weighing indicators. A data historian is used to store the raw data. Custom in-house algorithms have been developed using MATLAB to analyze the raw historical data and to automatically identify process information. This information includes the number of cycles completed and the mass of material transferred from stations to the process. The process information identified by the analysis is stored in a Microsoft SQL Server database. Visualization concepts have been developed that display the analyzed process information alongside visually compelling plots and animations of the raw data. The load cell monitoring system developed on the Mock F&W System was designed as a proof of concept that could be scaled to a field trial at an operating facility. This system, built with industry standard hardware and software, has allowed ORNL to develop capabilities that provide confidence in the ability to leverage existing operator load cell monitoring equipment with minimal impact on operations. The international safeguards community is evaluating the use of load cell monitoring as an additional safeguards measure; this system demonstrates a practical solution to collect, store, analyze, and visualize load cell weight data.

commercial off the shelf↗

10 MWE CDCL Large Pilot Plant – pre-FEED Study

Coal Direct Chemical Looping (CDCL) is an advanced oxy-combustion technology that has the potential to substantially reduce the energy penalty and the cost of electricity (COE) for coal-fired power generation with CO₂ capture. The Babcock & Wilcox Company (B&W) and The Ohio State University (OSU) have been collaborating on the development of an iron oxide oxygen-carrier based chemical looping technology for clean power generation with inherent carbon capture. In this process, coal is dried and pulverized prior to being transported into a moving-bed reducer. In the reducer, coal reacts with the oxygen-carrier particles, forming combustion byproducts, predominantly CO₂ and H₂O, while reducing the iron oxide oxidation state from Fe₂O₃ to a mixture of FeO and Fe. The reduced state particles are then transported to a combustor reactor and re-oxidized with air. Following the oxidation, the oxygen-carrier particles are regenerated, and a large amount of heat is released for steam production. The produced steam is sent to a turbine for electricity generation. Meanwhile, the CO₂–rich stream leaving the reducer is cooled, cleaned, and compressed for subsequent pipeline transportation and sequestration. By combining air separation and fuel conversion into a single system, the CDCL technology enables the intensification of oxy-combustion processes by eliminating the energy and cost intensive cryogenic air separation unit and thereby results in higher overall plant efficiencies and lower COE’s. The use of a moving-bed reducer results in high conversions of volatile hydrocarbons and high CO₂ purity, which reduces the cost of downstream CO₂ purification for sequestration or utilization. The Babcock & Wilcox Company in collaboration with The Ohio State University, Johnson & Matthey, The Electric Power Research Institute, and Dover Light & Power completed a Preliminary Front-End Engineering and Design (Pre-FEED) study of a 10 MWe coal-direct chemical looping (CDCL) pilot plant. The planned system is a modular 10 MWe CDCL large pilot facility consisting in 4 modules of 2.5 MWe each, working in parallel and to be hosted within the current structure at the City of Dover’s Municipal Power Plant. The CDCL system can achieve auto-thermal operation and includes a sub-critical steam cycle for power generation. The pilot system was designed to demonstrate full commercial operation at a reduced scale. The coal distribution per plan area is a representative slice of larger commercial arrangements. The system includes a CO₂ recycle system, but it does not include a compression system. The large pilot includes all the environmental control equipment and oxygen carrier and ash handling systems. As part of the project, the Team performed laboratory testing and carried out multiple pilot test campaigns to obtain design and performance information at the 250 kWth CDCL pilot facility at the Babcock & Wilcox Company’s Research Center. The Team demonstrated sustained operations at designed coal inputs, high coal conversion, high CO₂ purity, heat generation on the combustor, low carbon carryover between reactors and low particle attrition. Emissions generated in the reducer reactor were identified as SO₂ and NO x . The commercial manufacturing cost of oxygen carrier particle was evaluated by JM. A particle manufacturing report was generated and submitted to the DOE. Based on the results from the pilot tests and the pre-FEED design efforts, a techno-economic analysis was performed. The study shows that the CDCL process is a promising carbon-friendly technology capable of producing electricity with high efficiency. The estimated COE of the supercritical CDCL plant is $83.3 / MWh, which meets DOE’s target of less than 30% increase in COE when compared to a supercritical PC plant without CO₂ capture. This is the lowest among the existing carbon capture technologies (post-combustion and oxy-combustion) for fossil fuel power plant. CDCL is evaluated to be the most promising technology for carbon capture from the economic aspect.

01 COAL, LIGNITE, AND PEAT↗

Front-End Engineering Design (FEED) Study for a Carbon Capture Plant Retrofit to a Natural Gas-Fired Gas Turbine Combined Cycle Power Plant

A comprehensive front-end engineering design (FEED) study has been undertaken for a post-combustion capture (PCC) unit located at Panda’s Sherman natural gas–combined cycle (NGCC) power plant in Sherman, Texas. This is described in a full and unredacted FEED study report with all supporting documents, numbering over 150, also publicly available.

20 FOSSIL-FUELED POWER PLANTS↗

Front-End Engineering Design (FEED) Study for a Carbon Capture Plant Retrofit to a Natural Gas-Fired Gas Turbine Combined Cycle Power Plant (2x2x1 Duct-Fired 758-MWe Facility with F Class Turbines)

A comprehensive front-end engineering design (FEED) study has been undertaken by Bechtel National Inc. (Bechtel) for locating a post-combustion capture and compression (PCC) unit at Panda’s Sherman natural gas–combined cycle (NGCC) power plant in Sherman, Texas. This is described in the unredacted FEED Study report (Attachment 1) with all supporting documents, numbering over 150. The Study Report is publicly available. Sizing of the PCC plant is based on treating an amount of flue gas equivalent to that produced when generating 420 MW, which is approximately 68% of the total flue gas emitted by the NGCC power plant operating at guarantee condition with duct burners off. A reduced power plant capacity factor was used for sizing the PCC plant because the gas turbines at the site often operate at reduced load due to the high penetration of renewable power in the ERCOT region. The cost of carbon capture is primarily driven by capital cost (and therefore is highly sensitive to capacity factor). Sizing the capture unit so that when used it is nearly always operating at full capacity is critical to the economic viability of the proposed investment.

03 NATURAL GAS↗