Search NASA⌕ Search

SEARCH · Search NASA

Results for “focal planes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Strehl Ratio Meter for Focusing Segmented Mirrors 1

Initial focusing segmented mirrors that must be deployed in space, such as the Next Generation Space Telescope (NGST), provide challenges not faced before in the area of adaptive optics. The devices used to focus the mirror must minimize the power used and unnecessary mechanical movement. The device described in this report requires no movable parts except for the essential actuators required to move the mirror segments. Detail description of the components can be found in Coker, 1996. The primary mirror of the NGST will consist of 9 segments, a central annular segment, surrounded by 8 segments. The entire mirror assembly will be an 8 meter nearly filled circle (with the corners of the segments clipped to allow for storage in an Atlas IIe shroud). As the segments of the primary mirror are deployed to their operational positions, they must be positioned to within small fractions of a wavelength of near infrared light. When focused, the NGST will put most of its collected li-ht into the small region near the center of its focal plane. The ratio of the total light in the diffraction limited spot about the center of the focal plane to the total light in the focal plane. The purpose of this research effort is to design and build a device that will measure Strehl ratio and to use demonstrate that the Strehl ratio can be used to focus a segmented mirror.

Olivier, Philip D.↗

Cobra Fiber-Optic Positioner Upgrade

A prime focus spectrometer (PFS), along with corrective optics, will mount in place of the secondary mirror of the Subaru telescope on Mauna Kea, Hawaii. This will allow simultaneous observations of cosmologic targets. It will enable large-scale galactic archeology and dark energy surveys to help unlock the secrets of the universe. To perform these cosmologic surveys, an array of 2,400 optical fibers needs to be independently positioned within the 498-mm-diameter focal plane of the PFS instrument to collect light from galaxies and stars for spectrographic analyses. To allow for independent re-positioning of the fibers, a very small positioner (7.7 mm in diameter) is required. One hundred percent coverage of the focal plane is also required, so these small actuators need to cover a patrol region of 9.5 mm in diameter. To optimize the amount of light that can be collected, the fibers need to be placed within 5 micrometers of their intended target (either a star or galaxy). The Cobra Fiber Positioner was designed to meet the size and accuracy requirements stated above. Cobra is a two-degrees-of-freedom mechanism that can position an optical fiber in the focal plane of the PFS instrument to a precision of 5 micrometers. It is a theta-phi style positioner containing two rotary piezo tube motors with one offset from the other, which enables the optic fibers to be placed anywhere in a small circular patrol region. The patrol region of the actuator is such that the array of 2,400 positioners allows for full coverage of the instrument focal plane by overlapping the patrol areas. A second-generation Cobra positioner was designed based on lessons learned from the original prototype built in 2009. Improvements were made to the precision of the ceramic motor parts, and hard stops were redesigned to minimize friction and prevent jamming. These changes resulted in reducing the number of move iterations required to position the optical fiber within 5 micrometers of its target. At the time of this reporting, there are still many tests to be performed that will validate system level performance, but on an individual level, the Cobra positioner demonstrates excellent performance and will enable the PFS instrument to make unprecedented measurements of the universe. What is unique about the upgrades made to the Cobra positioner is the improved performance due to the design changes in the hard stops and the ceramic end caps of the motors. Other changes were made to reduce the unit cost of a Cobra positioner without affecting the performance, since thousands of these devices will have to be built for the PFS instrument.

Fisher, Charles D.↗

In-Flight Thermal Performance of the OCO-2 Instrument

The Orbiting Carbon Observatory-2 (OCO-2), launched on July 2, 2014, continues to operate nominally after successfully completing its primary mission of two years in space. It is hoped that, following a Senior Review and proposal phase, NASA will fund a two year extended mission, which would start in June 2017. The thermal design provides three temperature zones required by the instrument, specifically at 120 K, 267 K and 297 K. A single-stage pulse tube cryocooler provides refrigeration to three focal plane arrays to 120 K, via a high conductance flexible thermal strap. A variable conductance heat pipe (VCHP) based heat rejection system transports waste heat from the instrument, located inside the spacecraft, to the space-viewing radiators, providing tight temperature control of the spectrometer optics to 267 K, and maintains the electronics and cryocooler at 297 K. Soon after entering the A-Train on August 3, 2014, the optics and focal planes were cooled to their operating temperatures. Ice contamination of the cryogenic surfaces led to increased cryocooler loads and drove the need for two focal plane decontamination cycles between September 2014 and October 2014. A decrease in the radiometric gain of the O2 A-Band channel led to five additional focal plane decontamination cycles, between January 2015 and February 2017, and is now the primary driver of decontamination cycles. This paper provides a general overview of the thermal and cryogenic system design and reviews the inflight thermal performance for the mission.

Na-Nakornpanom, Arthur↗

Interferometric angle monitor

Two mutually coherent light beams formed from a single monochromatic light source were directed to a reflecting surface of a rotatable object. They were reflected into an imaging optical lens having a focal plane optically at infinity. A series of interference fringes were formed in the focal plane which were translated linearly in response to angular rotation of the object. Photodetectors were located adjacent the focal plane to detect the fringe translation and output a signal in response to the translation. The signal was fed to a signal processor which was adapted to count the number of fringes detected and develop a measure of the angular rotation and direction of the object.

Minott, P. O.↗

Coherent Detection of High-Rate Optical PPM Signals

A method of coherent detection of high-rate pulse-position modulation (PPM) on a received laser beam has been conceived as a means of reducing the deleterious effects of noise and atmospheric turbulence in free-space optical communication using focal-plane detector array technologies. In comparison with a receiver based on direct detection of the intensity modulation of a PPM signal, a receiver based on the present method of coherent detection performs well at much higher background levels. In principle, the coherent-detection receiver can exhibit quantum-limited performance despite atmospheric turbulence. The key components of such a receiver include standard receiver optics, a laser that serves as a local oscillator, a focal-plane array of photodetectors, and a signal-processing and data-acquisition assembly needed to sample the focal-plane fields and reconstruct the pulsed signal prior to detection. The received PPM-modulated laser beam and the local-oscillator beam are focused onto the photodetector array, where they are mixed in the detection process. The two lasers are of the same or nearly the same frequency. If the two lasers are of different frequencies, then the coherent detection process is characterized as heterodyne and, using traditional heterodyne-detection terminology, the difference between the two laser frequencies is denoted the intermediate frequency (IF). If the two laser beams are of the same frequency and remain aligned in phase, then the coherent detection process is characterized as homodyne (essentially, heterodyne detection at zero IF). As a result of the inherent squaring operation of each photodetector, the output current includes an IF component that contains the signal modulation. The amplitude of the IF component is proportional to the product of the local-oscillator signal amplitude and the PPM signal amplitude. Hence, by using a sufficiently strong local-oscillator signal, one can make the PPM-modulated IF signal strong enough to overcome thermal noise in the receiver circuits: this is what makes it possible to achieve near-quantum-limited detection in the presence of strong background. Following quantum-limited coherent detection, the outputs of the individual photodetectors are automatically aligned in phase by use of one or more adaptive array compensation algorithms [e.g., the least-mean-square (LMS) algorithm]. Then the outputs are combined and the resulting signal is processed to extract the high-rate information, as though the PPM signal were received by a single photodetector. In a continuing series of experiments to test this method (see Fig. 1), the local oscillator has a wavelength of 1,064 nm, and another laser is used as a signal transmitter at a slightly different wavelength to establish an IF of about 6 MHz. There are 16 photodetectors in a 4 4 focal-plane array; the detector outputs are digitized at a sampling rate of 25 MHz, and the signals in digital form are combined by use of the LMS algorithm. Convergence of the adaptive combining algorithm in the presence of simulated atmospheric turbulence for optical PPM signals has already been demonstrated in the laboratory; the combined output is shown in Fig. 2(a), and Fig. 2(b) shows the behavior of the phase of the combining weights as a function of time (or samples). We observe that the phase of the weights has a sawtooth shape due to the continuously changing phase in the down-converted output, which is not exactly at zero frequency. Detailed performance analysis of this coherent free-space optical communication system in the presence of simulated atmospheric turbulence is currently under way.

Vilnrotter, Victor↗

LANDSAT-4 sensor performance

Preflight and in-orbit sensor and data measurements indicate that TM meets or exceeds most specifications. Measured spectral band edges meet instrument specifications in 12 out of 14 cases; there is ample dynamic range. The signal-to-noise ratio exceeds specifications, except for band 3, channel 4; and band 7 channel 7 is very noisy but still meets specifications. The modulation transfer function of channel 4, band 2, is smaller than specified. Registration errors between the primary focal plane (PFP) and the cold focal plane (CFP) are about 0.75 pixels along-scan and 0.2 pixels across scan. Forward and reverse scan discontinuities, are well within ground-processing capabilities to rectify. Instrument gain variability, up to 7% for band 5, requires use of the internal calibration (IC) system to assure radiometric accuracy. Preliminary applications evaluation of image contents indicates that TM provides much better definition of edges than MSS.

Barker, J. L.↗

Landsat-4 sensor performance

Preflight and in-orbit sensor and data measurements indicate that TM meets or exceeds most specifications. Measured spectral band edges meet instrument specifications in 12 out of 14 cases; there is ample dynamic range. The signal-to-noise ratio exceeds specifications, except for band 3, channel 4; and band 7 channel 7 is very noisy but still meets specifications. The modulation transfer function of channel 4, band 2, is smaller than specified. Registration errors between the primary focal plane (PFP) and the cold focal plane (CFP) are about 0.75 pixels along-scan and 0.2 pixels across scan. Forward and reverse scan discontinuities are well within ground-processing capabilities to rectify. Instrument gain variability, up to 7 percent for band 5, requires use of the internal calibration (IC) system to assure radiometric accuracy. Preliminary applications evaluation of image contents indicates that TM provides much better definition of edges than MSS.

Barker, J. L.↗

ACIS Door Failure Investigation and Mitigation Procedures

NASA's Chandra X-ray Observatory (formerly AXAF) was launched on July 23, 1999 and is currently in orbit performing scientific studies. Chandra is the third of NASA's Great Observatories to be launched, following the Hubble Space Telescope and the Compton Gamma Ray Observatory. One of four primary science instruments on Chandra, and one of only two focal plane instruments, is the Advanced CCD Imaging Spectrometer, or ACIS. The ACIS focal plane and Optical Blocking Filter (OBF) must be launched under vacuum, so a tightly sealed, functioning door and venting subsystem were implemented. The door was opened two and one-half weeks after launch (after most out-gassing of composite materials) and allowed X-rays to be imaged by the ACIS CCD's in the focal plane. A failure of this door to open on-orbit would have eliminated all ACIS capabilities, severely degrading mission science. During the final pre-flight thermal-vacuum test of the fully integrated Chandra Observatory at TRW, the ACIS door failed to open when commanded to do so. This paper describes the efforts, under considerable time pressure, by NASA, its contractors and outside review teams to investigate the failure and to develop modified hardware and procedures which would correct the problem. Of interest is the fact that the root cause of the test failure was never clearly identified despite massive effort. We ultimately focussed on hardware and procedures designed to mitigate the effects of potential, but unproven, failure modes. We describe a frequent real-world engineering situation in which one must proceed on the best basis possible in the absence of the complete set of facts.

Podgorski, William A.↗

Performance and characterization of the SPT-3G digital frequency-domain multiplexed readout system using an improved noise and crosstalk model

The third-generation South Pole Telescope camera (SPT-3G) improves upon its predecessor (SPTpol) by an order of magnitude increase in detectors on the focal plane. The technology used to read out and control these detectors, digital frequency-domain multiplexing (DfMUX), is conceptually the same as used for SPTpol, but extended to accommodate more detectors. A nearly 5× expansion in the readout operating bandwidth has enabled the use of this large focal plane, and SPT-3G performance meets the forecasting targets relevant to its science objectives. However, the electrical dynamics of the higher-bandwidth readout differ from predictions based on models of the SPTpol system due to the higher frequencies used and parasitic impedances associated with new cryogenic electronic architecture. To address this, we present an updated derivation for electrical crosstalk in higher-bandwidth DfMUX systems and identify two previously uncharacterized contributions to readout noise, which become dominant at high bias frequency. The updated crosstalk and noise models successfully describe the measured crosstalk and readout noise performance of SPT-3G. These results also suggest specific changes to warm electronics component values, wire-harness properties, and SQUID parameters, to improve the readout system for future experiments using DfMUX, such as the LiteBIRD space telescope.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Imaging front-end systems for millimeter waves and submillimeter waves

Imaging (multi-beam) front-end systems utilize a reflector or a lens, as well as a focal-plane array of receptor elements (beams). To be practical, such systems must utilize focal plane arrays which can be fabricated using hybrid integrated (and eventually monolithic) technology. This paper reviews alternative approaches to focussing elements, auxiliary devices required for local oscillator injection and similar functions, and focal plane arrays. It also discusses general limitations and advantages of these approaches, as well as typical applications to millimeter and submillimeter astronomical instrumentation.

Yngvesson, K. S.↗

Two-Arm Flexible Thermal Strap

Airborne and space infrared cameras require highly flexible direct cooling of mechanically-sensitive focal planes. A thermal electric cooler is often used together with a thermal strap as a means to transport the thermal energy removed from the infrared detector. While effective, traditional thermal straps are only truly flexible in one direction. In this scenario, a cooling solution must be highly conductive, lightweight, able to operate within a vacuum, and highly flexible in all axes to accommodate adjustment of the focal plane while transmitting minimal force. A two-armed thermal strap using three end pieces and a twisted section offers enhanced elastic movement, significantly beyond the motion permitted by existing thermal straps. This design innovation allows for large elastic displacements in two planes and moderate elasticity in the third plane. By contrast, a more conventional strap of the same conductance offers less flexibility and asymmetrical elasticity. The two-arm configuration reduces the bending moment of inertia for a given conductance by creating the same cross-sectional area for thermal conduction, but with only half the thickness. This reduction in the thickness has a significant effect on the flexibility since there is a cubic relationship between the thickness and the rigidity or bending moment of inertia. The novelty of the technology lies in the mechanical design and manufacturing of the thermal strap. The enhanced flexibility will facilitate cooling of mechanically sensitive components (example: optical focal planes). This development is a significant contribution to the thermal cooling of optics. It is known to be especially important in the thermal control of optical focal planes due to their highly sensitive alignment requirements and mechanical sensitivity; however, many other applications exist including the cooling of gimbal-mounted components.

Urquiza, Eugenio↗

Installation of the Dark Energy Spectroscopic Instrument at the Mayall 4-meter telescope

The Dark Energy Spectroscopic Instrument (DESI) is a Stage IV ground-based dark energy experiment that will measure the expansion history of the Universe using the Baryon Acoustic Oscillation technique. The spectra of 35 million galaxies and quasars over 14000 square degrees will be measured during the life of the experiment. We describe the installation of the major elements of the instrument at the Mayall 4m telescope, completed in late 2019. The previous prime focus corrector, spider vanes, and upper rings were removed from the Mayall’s Serrurier truss and replaced with the newlyconstructed DESI ring, vanes, cage, hexapod, and optical corrector. The new corrector was optically aligned with the primary mirror using a laser tracker system. The DESI focal plane system was integrated to the corrector, with each of its ten 500-fiber-positioner petal segments installed using custom installation hardware and the laser tracker. Ten DESI spectrographs with 30 cryostats were installed in a newly assembled clean room in the Large Coude Room. The ten cables carrying 5000 optical fibers from the positioners in the focal plane were routed down the telescope through cable wraps at the declination and hour angle axes, and their integral slitheads were integrated with the ten spectrographs. The fiber view camera assembly was installed to the Mayall’s primary mirror cell. Servers for the instrument control system replaced existing computer equipment. The fully integrated instrument has been commissioned and is ready to start its operations phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Delta-Doped CCDs as Detector Arrays in Mass Spectrometers

In a conventional mass spectrometer, charged particles (ions) are dispersed through a magnetic sector onto an MCP at an output (focal) plane. In the MCP, the impinging charged particles excite electron cascades that afford signal gain. Electrons leaving the MCP can be read out by any of a variety of means; most commonly, they are post-accelerated onto a solid-state detector array, wherein the electron pulses are converted to photons, which, in turn, are converted to measurable electric-current pulses by photodetectors. Each step in the conversion from the impinging charged particles to the output 26 NASA Tech Briefs, February 2007 current pulses reduces spatial resolution and increases noise, thereby reducing the overall sensitivity and performance of the mass spectrometer. Hence, it would be preferable to make a direct measurement of the spatial distribution of charged particles impinging on the focal plane. The utility of delta-doped CCDs as detectors of charged particles was reported in two articles in NASA Tech Briefs, Vol. 22, No. 7 (July 1998): "Delta-Doped CCDs as Low-Energy-Particle Detectors" (NPO-20178) on page 48 and "Delta- Doped CCDs for Measuring Energies of Positive Ions" (NPO-20253) on page 50. In the present developmental miniature mass spectrometers, the above mentioned miniaturization and performance advantages contributed by the use of delta-doped CCDs are combined with the advantages afforded by the Mattauch-Herzog design. The Mattauch- Herzog design is a double-focusing spectrometer design involving an electric and a magnetic sector, where the ions of different masses are spatially separated along the focal plane of magnetic sector. A delta-doped CCD at the focal plane measures the signals of all the charged-particle species simultaneously at high sensitivity and high resolution, thereby nearly instantaneously providing a complete, high-quality mass spectrum. The simultaneous nature of the measurement of ions stands in contrast to that of a scanning mass spectrometer, in which abundances of different masses are measured at successive times.

Nikzad, Shouleh↗

NEAT: A Microarcsec Astrometric Telescope

NEAT, Nearby Exo-Earth Astrometric Telescope is a medium-small telescope ~ 1m in diameter that is designed to make ultra precise < 1 uas (microarcsec) astrometric measurements of nearby stars in a ~ 1hr observation. Four major error sources prevent normal space telescopes from obtaining accuracies close to 1 uas. Even with a small 1m telescope, photon noise is usually not a problem for the bright nearby target stars. But in general, the reference stars are much fainter. Typically a field of view of ~0.5 deg dia is needed to obtain enough bright reference stars. The NEAT concept uses a very simple but unusual design to avoid optically induced astrometric errors. The third source of error is the accuracy and stability of the focal plane. A 1uas error over a ~2000 arcsec field of view implies the focal plane is accurate or at least stable to 5 parts in 1010 over the lifetime of the mission (~5yrs). The 4th class of error has to do with our knowledge of the PSF and how that PSF is sampled by an imperfect detector. A Nyquist sampled focal plane would have > 2 pixels per ?/D, and centroiding to 1uas means centroiding to 10-5 pixels. This paper describes the mission concept, and an overview of the technology needed to perform 1uas astrometry with a small telescope, and how we overcome problems 1 and 2. A companion paper will describe the technical progress we've made in solving problems 3 and 4.

interferometry↗

Micro-Pixel Image Position Sensing Testbed

The search for Earth-mass planets in the habitable zones of nearby Sun-like stars is an important goal of astrophysics. This search is not feasible with the current slate of astronomical instruments. We propose a new concept for microarcsecond astrometry which uses a simplified instrument and hence promises to be low cost. The concept employs a telescope with only a primary, laser metrology applied to the focal plane array, and new algorithms for measuring image position and displacement on the focal plane. The required level of accuracy in both the metrology and image position sensing is at a few micro-pixels. We have begun a detailed investigation of the feasibility of our approach using simulations and a micro-pixel image position sensing testbed called MCT. So far we have been able to demonstrate that the pixel-to-pixel distances in a focal plane can be measured with a precision of 20 micro-pixels and image-to-image distances with a precision of 30 micro-pixels. We have also shown using simulations that our image position algorithm can achieve accuracy of 4 micro-pixels in the presence of lambda/20 wavefront errors.

astrometry↗

Star Tracker Accuracy Improvement and Optimization for Attitude Measurement in Three-Axis

High precision attitude measurement systems obviate the need for the beacon from the receiver making it possible for the spacecraft to beam a laser communications signal to a ground station without the ground station advertising its location. The research presented targets new detection and estimation methods to improve the accuracy in locating stars on a focal plane detector, and an understanding of the effects of changes in the optics design parameters and aberration, including defocus, on the navigation solution itself. This understanding can lead to an optimization of the attitude solution with respect to those optics realm parameter changes. The methodology discussed includes the development of a model of a current star tracker system. Using this model, multiple algorithms are implemented, including a multi-hypothesis method (MHT), to detect and estimate the position of the stars on the focal plane detector. It will be shown that using the MHT for detection and estimation, a greater accuracy can be found for each star estimation from more traditional detection and estimation algorithms. The approach then uses the model to develop statistics of the star tracker and the attitude estimation outputs to understand the accuracy, or variance, of the system's attitude solution. This solution is repeated for a range of defocus aberration, and a lower limit to the variance of the attitude solution is shown. A Cramer Rao lower bound solution is derived for the star tracker system and the results are compared to the Monte Carlo analysis from the model and shown to correlate very well. The approach uses a star image not as a Gaussian spot on the focal plane as done in previous work, and use of an image that includes the effects of aberrations of the optic system, and the effects of under-sampling and noise from the focal plane detector as well. Analysis includes exploring a star tracker's accuracy improvement through the combination of focus error and under-sampling effects alone, possibly contradicting conventional wisdom and approaches.

Lichter, Michael J.↗

Variable Shadow Screens for Imaging Optical Devices

Variable shadow screens have been proposed for reducing the apparent brightnesses of very bright light sources relative to other sources within the fields of view of diverse imaging optical devices, including video and film cameras and optical devices for imaging directly into the human eye. In other words, variable shadow screens would increase the effective dynamic ranges of such devices. Traditionally, imaging sensors are protected against excessive brightness by use of dark filters and/or reduction of iris diameters. These traditional means do not increase dynamic range; they reduce the ability to view or image dimmer features of an image because they reduce the brightness of all parts of an image by the same factor. On the other hand, a variable shadow screen would darken only the excessively bright parts of an image. For example, dim objects in a field of view that included the setting Sun or bright headlights could be seen more readily in a picture taken through a variable shadow screen than in a picture of the same scene taken through a dark filter or a narrowed iris. The figure depicts one of many potential variations of the basic concept of the variable shadow screen. The shadow screen would be a normally transparent liquid-crystal matrix placed in front of a focal-plane array of photodetectors in a charge-coupled-device video camera. The shadow screen would be placed far enough from the focal plane so as not to disrupt the focal-plane image to an unacceptable degree, yet close enough so that the out-of-focus shadows cast by the screen would still be effective in darkening the brightest parts of the image. The image detected by the photodetector array itself would be used as feedback to drive the variable shadow screen: The video output of the camera would be processed by suitable analog and/or digital electronic circuitry to generate a negative partial version of the image to be impressed on the shadow screen. The parts of the shadow screen in front of those parts of the image with brightness below a specified threshold would be left transparent; the parts of the shadow screen in front of those parts of the image where the brightness exceeded the threshold would be darkened by an amount that would increase with the excess above the threshold.

Lu, Ed↗

LWS design replacement study: Optimum design and tradeoff analysis

A design for two long-wavelength (LW) focal-plane and cooler assemblies, including associated preamplifiers and post-amplifiers is presented. The focal-planes and associated electronic assemblies are intended as direct replacement hardware to be installed into the existing 24-channel multispectral scanner used with the NASA Earth Observations Aircraft Program. An organization skilled in the art of LWIR systems can fabricate and deliver the two long-wavelength focal-plane assemblies described in this report when provided with the data and drawings developed during the performance of this contract. The concepts developed during the study including the alternative approaches and selection of components are discussed. Modifications to the preliminary design as reported in a preliminary design review meeting have also been included.

Source record↗