Search NASA⌕ Search

SEARCH · Search NASA

Results for “friction coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Review of antiskid and brake dynamics research

The behavior of various antiskid systems was investigated under controlled conditions. Results from utilizing a single main wheel of a DC-9 aircraft suggest that the systems investigated perform well under most circumstances but there may be room for improvement. For example, it was demonstrated that pressure bias modulation can adversely affect the response of antiskid systems to rapid changes in the runway friction level. Results also indicate that antiskid systems designed to operate at a slip ratio of approximately 0.1 can provide a maximum braking effort without undue loss in the cornering capability of the tire. Time histories of braking friction coefficient were shown to provide a means of determining antiskid system performance and for systems that employed pressure bias modulation it was shown that performance could also be estimated from time histories of brake pressure and torque.

Stubbs, S. M.↗

Studies of some unconventional systems for solving various landing problems

Solutions to various landing problems were obtained through unconventional systems. The first, of these is the air cushion landing system, where efforts were concentrated on development of adequate braking and steering systems and an improved understanding of scaling laws and behavior. The second was concentrated on use of a wire brush skid as a drag producing device, which was shown to have good friction coefficients and reasonable wear rates at ground bearing pressures up to 689 kPa and forward speeds up to 80 km/hr. The third showed great promise in an active control landing gear where significant load reductions were possible during landing impact and subsequent rollout.

Leland, T. J.↗

Steady-state boundary lubrication with formulated C-ethers to 260 C

Steady state wear and friction studies were made at boundary lubrication conditions in a pin on disk (pure iron on rotating CVM M 50 steel) sliding friction apparatus with five C ether formulated fluids (modified polyphenyl ether containing phosphrous ester, organic acid, and other additives). Conditions included 20, 150, and 260 C disk temperatures, dry air test atmosphere, 1 kilogram load, 50 rpm disk speed, and test times to 130 minutes. Results were compared with those obtained with a formulated MIL L 27502 candidate ester and the C ether base fluid. Three of the C ether formulations gave better lubrication than both reference fluids under most conditions. The other two C ether formulations yielded higher wear rates and friction coefficients than the C ether base fluid for most of the temperature range. Only one C ether formulation showed consistently higher steady state wear rates than the ester.

Loomis, W. R.↗

Behavior of aircraft antiskid braking systems on dry and wet runway surfaces: Hydromechanically controlled system

The investigation utilized one main gear wheel, brake, and tire assembly of a McDonnell Douglas DC-9 series 10 airplane. The landing-gear strut was replaced by a dynamometer. During maximum braking, average braking behavior indexes based upon brake pressure, brake torque, and drag-force friction coefficient developed by the antiskid system were generally higher on dry surfaces than on wet surfaces. The three braking behavior indexes gave similar results but should not be used interchangeably as a measure of the braking of this antiskid sytem. During the transition from a dry to a flooded surface under heavy braking, the wheel entered into a deep skid but the antiskid system reacted quickly by reducing brake pressure and performed normally during the remainder of the run on the flooded surface. The brake-pressure recovery following transition from a flooded to a dry surface was shown to be a function of the antiskid modulating orifice.

Tanner, J. A.↗

Modification in drag of turbulent boundary layers resulting from manipulation of large-scale structures

The effects of placing a parallel-plate turbulence manipulator in a boundary layer are investigated by means of flow visualization and hot-wire measurements. The manipulator was found to be effective in inhibiting the intermittent large scale structure of the boundary layer, and the effect persists for at least 70 boundary-layer thicknesses downstream of the manipulator. With the removal of the large scale, there was an observed reduction in the streamwise turbulence intensity levels near the wall. The downstream distribution of the skin friction coefficient, determined from the stream wise change in fluid momentum, was also altered by the introduction of the manipulator. The data from both the visualization and hot wire studies are provided.

Corke, T. C.↗

Experimental investigation of drag on a compliant surface

The feasibility of reducing turbulent skin-friction drag by means of surface compliance was studied experimentally in a fully developed flat-plate turbulent boundary layer in air, using a membranous surface backed by a thin cavity containing a layer of polyurethane foam. Surface motion characteristics, boundary layer structure, and overall drag were measured over a range of freestream speeds from 7 to 30 m/sec, and a range of membrane tensions from 44 to 350 N/m. Low-amplitude long-wavelength motions predominate, and no significant change from the rigid surface skin-friction coefficients was observed.

Mcmichael, J. M.↗

Tribological characteristics of nitrogen (N+) implanted iron

The effect of implantation of nitrogen ions (1.5 MeV) on the friction and wear characteristics of pure ion sliding against M-50 steel (unimplanted) was studied in a pin-on-disk sliding friction apparatus. Test conditions included room temperature (25 C), a dry air atmosphere, a load of 1/2 kg (4.9 N), sliding velocities of 0.043 to 0.078 m/sec (15 to 25 rpm), a pure hydrocarbon lubricant (n-hexadecane), or a U.S.P. mineral oil and nitrogen ion implantation doses of 5x10 to the 15th power and 5x10 to the 17th power ions/sq cm. No differences in wear rates were observed in the low dose experiments. In the high dose experiments, small reductions in initial (40 percent) and steady state (20 percent) wear rates were observed for nitrogen implanted iron riders as compared with unimplanted controls. No differences in average friction coefficients were noted for either dose. Auger electron spectroscopy combined with argon ion bombardment revealed a subsurface Gaussian nitrogen distribution with a maximum concentration of 6 atomic percent at a depth of 0.8 microns. Similar analysis within the wear scar of an implanted rider after 20 microns of wear yielded only background nitrogen concentration. No inward migration of nitrogen ions was observed.

Jones, W. R.↗

A vectorized code for calculating laminar and turbulent hypersonic flows about blunt axisymmetric bodies at zero and small angles of attack

A user's guide is provided for a computer code which calculates the laminar and turbulent hypersonic flows about blunt axisymmetric bodies, such as spherically blunted cones, hyperboloids, etc., at zero and small angles of attack. The code is written in STAR FORTRAN language for the CDC-STAR-100 computer. Time-dependent, viscous-shock-layer-type equations are used to describe the flow field. These equations are solved by an explicit, two-step, time asymptotic, finite-difference method. For the turbulent flow, a two-layer, eddy-viscosity model is used. The code provides complete flow-field properties including shock location, surface pressure distribution, surface heating rates, and skin-friction coefficients. This report contains descriptions of the input and output, the listing of the program, and a sample flow-field solution.

Kumar, A.↗

Stress concentration in the vicinity of a hole defect under conditions of Hertzian contact

Two-dimensional photoelastic stress analyses were conducted for epoxy resin models containing a hole defect under the conditions of Hertzian contact. Stress concentrations around the defect were determined as a function of several parameters. These were hole diameter, its vertical distance from the contact surface, and the horizontal distance from the Hertzian contact area. Also determined was the effect of tangential traction (generated by a friction coefficient of 0.1) on the stress concentration. Sharp stress concentrations occur in the vicinity of both the left and the right side of the hole. The stress concentration becomes more distinct the larger the hole diameter and the smaller the distance between the hole and the contact surface. The stress concentration is greatest when the disk imposing a normal load is located at the contact surface directly over the hole. The magnitude and the location of stress concentration varies with the distance between the Hertzian contact area and the hole. Taking into account the stress amplitude, the area which can be involved in a process of rolling contact fatigue seems to be confined to a shallow region at both sides of the hole. The effect of tangential traction is comparatively small on the stress concentration around the hole.

Yamamoto, T.↗

Correlation of Preston-tube data with laminar skin friction

Preston-tube data have been obtained on a sharp ten-degree cone in the NASA Ames Eleven-Foot Transonic Wind Tunnel. Data were obtained over a Mach number range of 0.30 to 0.95 and unit Reynolds numbers of 9.84, 13.1, and 16.4 million per meter. The portions of these data, that were obtained within laminar boundary layers, have been correlated with the corresponding values of theoretical skin friction. The rms scatter of skin-friction coefficient about the correlation is of the order of one percent, which is comparable to the reported accuracy for calibrations of Preston-tubes in incompressible pipe-flows. In contrast to previous works on Preston-tube/skin-friction correlations, which are based on the physical height of the probe's face, this very satisfactory correlation for compressible boundary-layer flows is achieved by accounting for the effects of a variable 'effective' height of the probe. The coefficients, which appear in the correlation, are dependent on the particular tunnel environment. The general procedure can be used to define correlations for other wind tunnels.

Reed, T. D.↗

Effect of load, area of contact, and contact stress on the tribological properties of polyimide bonded graphite fluoride films

A pin-on-disk type of friction and wear apparatus was used to study the effect of load, contact stress and rider area of contact on the friction and wear properties of polyimide-bonded graphite fluoride films. Different rider area contacts were obtained by initially generating flats (with areas of 0.0035, 0.0071, 0.0145, and 0.0240 cm) on 0.476-cm radius hemispherically-tipped riders. Different projected contact stresses were obtained by applying loads of 2.5-to 58.8-N to the flats. Two film wear mechanisms were observed. The first was found to be a linear function of contact stress and was independent of rider area of contact. The second was found to increase exponentially as the stress increased. The second also appeared to be a function of rider contact area. Wear equations for each mechanism were empirically derived from the experimental data. In general, friction coefficients increased with increasing rider contact area and with sliding duration. This was related to the build-up of thick rider transfer films.

Fusaro, R. L.↗

Experimental investigation of turbulent wall-jets in the presence of adverse pressure gradients in a rectangular diffuser

An experimental study of wall static pressure distributions and mean velocity profiles along a duct and diffuser downstream of wall-jet injection was conducted over a range of diffuser total angles from 15 to 40 deg at injection to core flow mass flux ratios from 0 to 6. Pressure recovery in the diffuser increased with injection ratio and decreased with diffuser total angle. Peak velocities in the wall-jet decayed along the flow and the inner shear layer and outer mixing region grew in thickness along the flow. The inner layer was near similarity condition, but non-similar variations were found in the outer layer. Estimated wall shear stresses depended upon injection mass fluxes, downstream distance and diffuser total angle. Greater decay of peak velocity and larger friction coefficients were found in the diffuser than indicated by correlations from data for a wall-jet without a pressure gradient. At the largest diffuser total angle and the highest injection ratio flow reversal occurred in the core region.

Back, L.↗

Stagnation point heat transfer augmentation due to free stream turbulence

A model has been proposed for the momentum eddy diffusivity induced by free stream turbulence intensity and integral length scale. The eddy diffusivity model is applied to the stagnation point of a cylinder situated in a uniform crossflow in the presence of free stream turbulence. A numerical solution of the governing momentum and energy equations with the proposed eddy diffusivity model yielded results for the skin friction coefficient and the Nusselt number. The numerical predictions of the present work are compared with experimental data and the agreement between the two is seen to be very good.

Gorla, R. S. R.↗

Fundamental aspects of polyimide dry film and composite lubrication: A review

The tribological properties of polyimide dry films and composites are reviewed. Friction coefficients, wear rates, transfer film characteristics, wear surface morphology, and possible wear mechanisms of several different polyimide films, polyimide-bonded solid lubricants, polyimide solid bodies, and polyimide composites are discussed. Such parameters as temperature, type of atmosphere, load, contact stress, and specimen configuration are investigated. Data from an accelerated test device (Pin-on-Disk) are compared to similar data obtained from an end use application test device (plain spherical bearing).

Fusaro, R. L.↗

A New View on Origin, Role and Manipulation of Large Scales in Turbulent Boundary Layers

The potential of passive 'manipulators' for altering the large scale turbulent structures in boundary layers was investigated. Utilizing smoke wire visualization and multisensor probes, the experiment verified that the outer scales could be suppressed by simple arrangements of parallel plates. As a result of suppressing the outer scales in turbulent layers, a decrease in the streamwise growth of the boundary layer thickness was achieved and was coupled with a 30 percent decrease in the local wall friction coefficient. After accounting for the drag on the manipulator plates, the net drag reduction reached a value of 20 percent within 55 boundary layer thicknesses downstream of the device. No evidence for the reoccurrence of the outer scales was present at this streamwise distance thereby suggesting that further reductions in the net drag are attainable. The frequency of occurrence of the wall events is simultaneously dependent on the two parameters, Re2 delta sub 2 and Re sub x. As a result of being able to independently control the inner and outer boundary layer characteristics with these manipulators, a different view of these layers emerged.

Corke, T. C.↗

The XPS depth profiling and tribological characterization of ion-plated gold on various metals

Friction properties were measured with a gold film; the graded interface between gold and nickel substrate; and the nickel substrate. All sliding was conducted against hard silicon carbide pins in two processes. In the adhesive process, friction arises primarily from adhesion between sliding surfaces. In the abrasion process, friction occurs as a result of the hard pin sliding against the film, indenting into it, and plowing a series of grooves. Copper and 440 C stainless steel substrates were also used. Results indicate that the friction related to both adhesion and abrasion is influenced by coating depth. The trends in friction behavior as a function of film depth are, however, just the opposite. The graded interface exhibited the highest adhesion and friction, while the graded interface resulted in the lowest abrasion and friction. The coefficient of friction due to abrasion is inversely related to the hardness. The greater the hardness of the surface, the lower is the abrasion and friction. The microhardness in the graded interface exhibited the highest hardness due to an alloy hardening effect. Almost no graded interface between the vapor-deposited gold film and the substrates was detected.

Miyoshi, K.↗

RF sputtered silicon and hafnium nitrides: Properties and adhesion to 440C stainless steel

Silicon nitride and hafnium nitride coatings were deposited by reactive RF sputtering on oxidized and unoxidized 440C stainless steel substrates. Sputtering was done in mixtures of argon and nitrogen gases from pressed powder silicon nitride and from hafnium metal targets. Depositions were at two background pressures, 8 and 20 mtorr, and at two different fractions (f) of nitrogen in argon, 0.25 and 0.60, for hafnium nitride and at f = 0.25 for silicon nitride. The coatings and the interface between the coating and substrates were investigated by X-ray diffractometry, scanning electron microscopy, energy dispersive X-ray analysis and Auger electron spectroscopy. A Knoop microhardness of 1650 + or - 100 kg/sq mm was measured for hafnium nitride and 3900 + or - 500 kg/sq mm for silicon nitride. The friction coefficients between a 440C rider and the coatings were measured under lubricated conditions. Scratch test results demonstrate that the adhesion of hafnium nitride to both oxidized and unoxidized 440C is superior to that of silicon nitride. Oxidized 440C is found to have increased adhesion, to both nitrides, over that of unoxidized 440C.

Grill, A.↗

Tribological characteristics of nitrogen (N+) implanted iron

The effect of implantation of nitrogen ions (1.5 MeV) on the friction and wear characteristics of pure ion sliding against M-50 steel (unimplanted) was studied in a pin-on-disk sliding friction apparatus. Test conditions included room temperature (25 C), a dry air atmosphere, a load of 1/2 kg (4.9 N), sliding velocities of 0.043 to 0.078 m/sec (15 to 25 rpm), a pure hydrocarbon lubricant (n-hexadecane), or a U.S.P. mineral oil and nitrogen ion implantation doses of 5x10 to the 15th power and 5x10 to the 17th power ions/sq cm. No differences in wear rates were observed in the low dose experiments. In the high dose experiments, small reductions in initial (40 percent) and steady state (20 percent) wear rates were observed for nitrogen implanted iron riders as compared with unimplanted controls. No differences in average friction coefficients were noted for either dose. Auger electron spectroscopy combined with argon ion bombardment revealed a subsurface Gaussian nitrogen distribution with a maximum concentration of 6 atomic percent at a depth of 0.8 microns. Similar analysis within the wear scar of an implanted rider after 20 microns of wear yielded only background nitrogen concentration. No inward migration of nitrogen ions was observed. Previously announced in STAR as N82-24322

Jones, W. R., Jr.↗