Search NASA⌕ Search

SEARCH · Search NASA

Results for “gas injection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Operation above the Greenwald density limit in high performance DIII-D negative triangularity discharges

The density limit in strongly-shaped negative triangularity (NT) discharges is studied experimentally in the DIII-D tokamak. Record-high Greenwald fractions f G are obtained, using gas puff injection only, with values up to near 2, where f G is defined as the ratio of the line-averaged density over n G = I p /(π a 2 ), with I p [MA] the plasma current and a[m] the plasma minor radius. A clear higher operational limit with higher auxiliary power is also demonstrated, with the ohmic density limit about two times lower than with additional neutral beam injection heating. The evolution of the electron density, temperature and pressure profiles are analyzed as well. The core density can be up to twice the Greenwald density and keeps increasing, while the value at the separatrix remains essentially constant and slightly below n G . The edge temperature gradient collapses to near zero and NT plasmas are shown to be resilient to such profiles in terms of disruptivity. We also present the time evolution of the inverse electron pressure scale length with the value at the last closed flux surface (LCFS) decreasing below the value at the normalized radius 0.9 near the density limit, demonstrating the clear drop of confinement starting from the edge. This inverse scale length ‘collapse’ at the LCFS also defines well the characteristic behavior of the kinetic profiles approaching a density limit.

density limit↗

Field, frequency, and temperature dependencies of the surface resistance of nitrogen diffused niobium superconducting radio frequency cavities

We investigate the rf performance of several single-cell superconducting radio-frequency cavities subjected to low temperature heat treatment in nitrogen environment. The cavities were treated at temperature 120 – 165 ° C for an extended period of time (24–48 h) either in high vacuum or in a low partial pressure of ultrapure nitrogen. The improvement in Q 0 with a Q rise was observed when nitrogen gas was injected at ∼ 300 ° C during the cavity cooldown from 800 ° C and held at 165 ° C , without any degradation in accelerating gradient over the baseline performance. The treatment was applied to several elliptical cavities with frequency ranging from 0.75 to 3.0 GHz, showing an improved quality factor as a result of low temperature nitrogen treatments. The Q rise feature is similar to that achieved by nitrogen alloying Nb cavities at higher temperature, followed by material removal by electropolishing. The surface modification was confirmed by the change in electronic mean free path and tuned with the temperature and duration of heat treatment. The decrease of the temperature-dependent surface resistance with increasing rf field, resulting in a Q rise, becomes stronger with increasing frequency and decreasing temperature. The data suggest a crossover frequency of ∼ 0.95 GHz above that the Q rise phenomenon occurs at 2 K. Some of these results can be explained qualitatively with an existing model of intrinsic field-dependence of the surface resistance with both equilibrium and nonequilibrium quasiparticle distribution functions. The change in the Q slope below 0.95 GHz may result from masking contribution of trapped magnetic flux to the residual surface resistance. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Enabling off-highway diesel engine downsizing and performance improvement using electrically assisted turbocharging

Internal combustion engine (ICE) downsizing through various turbocharging configurations is generally known by the powertrain design community as an effective means to reduce frictional losses, increase waste heat recovery, and improve fuel efficiency while increasing engine power density. However, often is the case that turbocharging strategies, including variable geometry turbochargers, and regulated two-stage turbochargers, incur the performance tradeoff between transient response and fuel economy (pumping losses) at high engine speeds. For off-highway vehicles having particularly transient and high-powered duty cycles, efforts to improve this tradeoff and increase operational flexibility have turned to evaluating various electrified air system architectures. In this study, a 4.5 L diesel-ICE configured with an electrically driven compressor (eBooster ® ) is placed in series with a conventional turbocharger and integrated into a 48 V mild-hybrid powertrain architecture. The objective of this powertrain configuration is to enable engine downsizing by 34%, replacing the current 6.8 L ICE platform with the hybridized 4.5 L ICE concept. The commercial 1-D simulation software GT-SUITE is used for powertrain system development and system optimization. Development and validation of the GT-SUITE model and air system controls is concurrently supported through experimental data collection. The simulation model development includes using machine learning methods for optimizing exhaust gas dilution, injection timing, and eBooster ® power to improve steady-state and transient brake-specific fuel consumption while minimizing criteria pollutant emissions. It was found that total specific fluid consumption over the standardized non-road transient engine duty cycle could be reduced by 18% over the current 6.8 L engine by using an optimized eBoosted 4.5 L engine. The hybridized 4.5 L engine concept concurrently showed sufficient transient response capability and nearly an order of magnitude reduction in duty cycle total soot production.

25 ENERGY STORAGE↗

Understanding the field and frequency dependence of rf loss in SRF cavities

SRF cavities subjected to heat treatment below 200 °C in the presence of nitrogen showed an improvement in quality factor while maintaining an accelerating gradient above 25 MV/m. Here, we report the rf performance of several single-cell superconducting radio frequency cavities with frequency ranging from 0.75 - 3.0 GHz subjected to low temperature heat treatment in nitrogen environment. The cavities were treated at temperature 120 - 175 oC for 24 - 48 hours in low partial pressure of ultra-pure nitrogen gas. The improvement in Q? with Q-rise was observed when nitrogen gas was injected ~300 °C during the furnace treatment. The surface modification was confirmed by the change in electronic mean free path and near surface elemental analysis by SIMS. The field dependence of the rf losses is strongly correlated to the cavity frequency. The analysis of experimental data with available theoretical models as well as comparison with similar study on high temperature nitrogen doped cavities will be presented.

Ciovati, Gianluigi↗

Annual Performance Testing of Tracer Gas Detectors for use in Radionuclide NESHAP Compliance Testing

Los Alamos National Laboratory’s (LANL’s) compliance with Radionuclide NESHAP0F 1 regulations is managed by the Radioactive Air Emissions Management (RAEM) team, part of LANL’s Compliance Programs group (EPC-CP). One area of the Radionuclide NESHAP addresses requirements for siting a stack sample system. Prior to commissioning a new stack sampling system, the ANSI Standard for stack sampling requires that the stack sample location must meet several criteria, including uniform mixing of tracer gas (sulfur hexafluoride, SF 6 ) and tracer aerosol (liquid oil droplets) in the air stream. This memorandum will specifically focus on the tracer gas portion of the ANSI Standard. For these mix tests, tracer gas is injected into the stack air stream and the resulting air concentrations are measured across the plane of the stack at the proposed sampling location. The coefficient of variation of the media concentration must be under 20% when evaluated over the central 2/3 area of the stack or duct.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Review of CCUS in the Context of Foams, Regulatory Frameworks and Monitoring

Greenhouse gas emission into the atmosphere is considered the main reason for the rise in Earth’s mean surface temperature. According to the Paris Agreement, to prevent the rise of the global average surface temperature beyond two degrees Celsius, global CO2 emissions must be cut substantially. While a transition to a net-zero emission scenario is envisioned by mid-century, carbon capture, utilization, and storage (CCUS) will play a crucial role in mitigating ongoing greenhouse gas emissions. Injection of CO2 into geological formations is a major pathway to enable large-scale storage. Despite significant recent technological advancements, mass deployment of these technologies still faces several technical and non-technical difficulties. This paper provides an overview of technical milestones reached thus far in CO2 capture, utilization, geological storage, monitoring technologies, and non-technical aspects such as regulatory frameworks and related policies in the US and the rest of the world. This paper describes different injection methods to store CO2 in various subsurface formations, the use of foams and the resulting potential gains in CO2 storage capacity, the role of nanoparticles for foam stabilization, and ensuring long-term storage safety. This work also addresses several safety-related aspects of geological storage and subsurface monitoring technologies that may mitigate risks associated with long-term storage.

42 ENGINEERING↗

Predictive Modeling of NOx Emissions from Lean Direct Injection of Hydrogen and Hydrogen/Natural Gas Blends Using Flame Imaging and Machine Learning

This research paper explores the use of machine learning to relate images of flame structure and luminosity to measured NOx emissions. Images of reactions produced by 16 aero-engine derived injectors for a ground-based turbine operated on a range of fuel compositions, air pressure drops, preheat temperatures and adiabatic flame temperatures were captured and postprocessed. The experimental investigations were conducted under atmospheric conditions, capturing CO, NO and NOx emissions data and OH* chemiluminescence images from 27 test conditions. The injector geometry and test conditions were based on a statistically designed test plan. These results were first analyzed using the traditional analysis approach of analysis of variance (ANOVA). The statistically based test plan yielded 432 data points, leading to a correlation for NOx emissions as a function of injector geometry, test conditions and imaging responses, with 70.2% accuracy. As an alternative approach to predicting emissions using imaging diagnostics as well as injector geometry and test conditions, a random forest machine learning algorithm was also applied to the data and was able to achieve an accuracy of 82.6%. This study offers insights into the factors influencing emissions in ground-based turbines while emphasizing the potential of machine learning algorithms in constructing predictive models for complex systems.

08 HYDROGEN↗

Preparation of fine-particles at cryogenic temperatures

Flash freezing process yields gelling agent for use at cryogenic temperatures. Vaporized material, diluted with an inert gas, is injected below the surface of an agitated cryogenic liquid. This method disperses particles of chlorine trifluoride in liquid oxygen difluoride.

Globus, H.↗

Radiative coupled viscous flow with massive blowing

An analysis of the fully-coupled viscous, radiating flow past an ablating blunt body at hyperbolic entry conditions is presented. A detailed thermodynamics computation, as well as a realistic radiation transport model, is included. A locally nonsimilar approach is employed to solve the conservation equations away from the stagnation point. The validity of the locally nonsimilar approach is demonstrated for some nonablating cases. Sample calculations are made for the typical flight condition of a Jovian entry probe. The effects of the downstream injection of the ablation products of a carbon heat shield on the flux distribution around the body are discussed in detail. It is found that most of the radiative energy is absorbed by the injected carbon gas and dumped into the wake.

Chou, Y. S.↗

Depletion of the F2 region ionosphere and the protonosphere by the release of molecular hydrogen

Theoretical models have been used to investigate the effects of artificially injected H2 gas on plasma densities in the ionospheric F region and the overlying protonosphere. Owing to large reaction rates between H2 and ionospheric O(+) ions, plasma densities in both daytime and nighttime ionospheres can be greatly reduced by modest amounts of released H2 gas. One hundred kg of H2 released at 300-km altitude reduces local O(+) densities by more than three orders of magnitude and produces about a 5% depression in H(+) densities in the overlying protonosphere. These results suggest that it should be possible to conduct controlled chemical-modification experiments for investigation of many outstanding ionospheric and magnetospheric problems.

Bernhardt, P. A.↗

Stagnation region gas film cooling: Spanwise angled injection from multiple rows of holes

The stagnation region of a cylinder in a cross flow was used in experiments conducted with both a single row and multiple rows of spanwise angled (25 deg) coolant holes for a range of the coolant blowing ratio with a freestream to wall temperature ratio approximately equal to 1.7 and R(eD) = 90,000. Data from local heat flux measurements are presented for injection from a single row located at 5 deg, 22.9 deg, 40.8 deg, 58.7 deg from stagnation using a hole spacing ratio of S/d(o) = 5 and 10. Three multiple row configurations were also investigated. Data are presented for a uniform blowing distribution and for a nonuniform blowing distribution simulating a plenum supply. The data for local Stanton Number reduction demonstrated a lack of lateral spreading by the coolant jets. Heat flux levels larger than those without film cooling were observed directly behind the coolant holes as the blowing ratio exceeded a particular value. The data were spanwise averaged to illustrate the influence of injection location, blowing ratio and hole spacing. The large values of blowing ratio for the blowing distribution simulating a plenum supply resulted in heat flux levels behind the holes in excess of the values without film cooling. An increase in freestream turbulence intensity from 4.4 to 9.5 percent had a negligible effect on the film cooling performance.

Luckey, D. W.↗