Search NASA⌕ Search

SEARCH · Search NASA

Results for “geometry optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

Process optimization of complex geometries using feed forward control for laser powder bed fusion additive manufacturing

Additive manufacturing (AM) enables the fabrication of complex designs that are difficult to create by other means. Metal parts manufactured by laser powder bed fusion (LPBF) can incorporate intricate design features and demonstrate desirable mechanical properties. However, printing a part that is qualified for its intended application often involves reprinting and discarding many parts to eliminate defects, improve dimensional accuracy, and increase repeatability. The process of iteratively converging on the appropriate build parameters increases the time and cost of creating functional LPBF manufactured parts. This work describes a fast, scalable method for part-scale process optimization of arbitrary geometries. Additionally, the computational approach uses feature extraction to identify scan vectors in need of parameter adaptation and applies results from simulation-based feed forward control models. This method provides a framework to quickly optimize complex parts through the targeted application of models with a range of fidelity and by automating the transfer of optimization strategies to new part designs. The computational approach and algorithmic framework are described, a software package is implemented, the method is applied to parts with complex features, and parts are printed on a customized open architecture LPBF machine.

3D printing↗

Optimization of Fairing Geometry for ORPC Modular RivGen Power System: Cooperative Research and Development (Final Report)

The work will optimize the hydrodynamic performance and flow augmentation of Ocean Renewable Power Company's (ORPC) modular fairing for their cross-flow marine hydrokinetic (MHK) turbine, using a computational fluid dynamics study. The influence of the fairing cross-sectional shape and rotor-fairing spacing will be assessed, to maximize power production and minimize structural loads.

16 TIDAL AND WAVE POWER↗

RAPID OPTIMAL SPH PARTICLE DISTRIBUTIONS IN SPHERICAL GEOMETRIES FOR CREATING ASTROPHYSICAL INITIAL CONDITIONS

Creating spherical initial conditions in smoothed particle hydrodynamics simulations that are spherically conformal is a difficult task. Here, we describe two algorithmic methods for evenly distributing points on surfaces that when paired can be used to build three-dimensional spherical objects with optimal equipartition of volume between particles, commensurate with an arbitrary radial density function. We demonstrate the efficacy of our method against stretched lattice arrangements on the metrics of hydrodynamic stability, spherical conformity, and the harmonic power distribution of gravitational settling oscillations. We further demonstrate how our method is highly optimized for simulating multi-material spheres, such as planets with core–mantle boundaries.

79 ASTRONOMY AND ASTROPHYSICS↗

Geometry-independent microstructure optimization for electron beam powder bed fusion additive manufacturing

The ability to manipulate the formation of microstructure is one of the potential advantages of additive manufacturing. Yet, the additive manufacturing process is riddled with complex interactions between processing parameters, geometry, and spot melting sequence which makes the task of controlling microstructure challenging. This paper proposes a method to solve the microstructure texture optimization problem by leveraging established optimization techniques and increasingly fast and accurate analytical heat transfer models. Respectively, we apply two different optimization algorithms, genetic algorithm and concurrent greedy line search, in order to induce arbitrarily shaped microstructure regions and we use a heat transfer model to evaluate the fitness of solutions in an iterative approach that is far more efficient than pure trial and error. The objective of the optimization algorithm is to control local thermal conditions – hence microstructure formation – during the melting process by manipulating the order and the dwell time of all the points of the infill pattern sequence. We then analyze the optimized sequence to determine important path characteristics that affect the microstructure formation. Through examples, we show that relative order and frequency, as measured by weighted average and variance of spot order, are important factors that influence the final characteristics.

36 MATERIALS SCIENCE↗

A method for optimizing LINAC treatment geometry for volumetric modulated arc therapy of multiple brain metastases

Purpose: Volumetric modulated arc therapy (VMAT) is a rotational delivery technique in which MLC shapes, dose rate, and gantry rotation speed are optimized to produce conformal dose distributions. The aim of this work is to develop a beam projection method for deriving the optimal table and collimator angles for multilesion treatment planning. Methods: The method consists of four steps. The first step is to define the vector of beam-eye-view (BEV)-Y-axis in the treatment planning CT coordinates. The second step is to project each target onto the BEV-Y-axis vector. In the third step, the best table and collimator angle are found with a brute-force optimization technique that minimizes MLC leaf sharing between lesions. The fourth step is to generate an optimized VMAT plan with appropriate table/collimator angles and evaluate the plan quality. Results: The authors tested the method on three example cases with targets of various locations in the brain and sizes ranging from 1.18 to 17.86 cm{sup 3}. Applying the optimized geometric parameter to generate VMAT plan, a reduction of the 12 Gy volume was more than 6.1% for all cases; the plan homogeneity (D{sub 2%}-D{sub 95%}) was improved from 5.88{+-}1.21 to 5.21{+-}0.93 Gy vs a VMAT plan with the manufacturer recommended table and collimator angles. Conclusions: The authors conclude that the use of the projection method minimizes the sharing of MLC leaves between lesions and improves the plan quality for multilesion VMAT delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relativistic and magnetic Breit effects for the reaction Sg + 6CO → Sg(CO)6 and Sg(OC)6: Prediction of the existence and atomization energy of the isomer Sg(OC)6

Our ab initio all-electron fully relativistic Dirac–Fock (DF) and Dirac–Fock–Breit–Gaunt (DFBG) and nonrelativistic (NR) Hartree–Fock (HF) calculations for seaborgium hexacarbonyl Sg(CO)6 predict atomization energies (Ae) of 68.81, 69.28, and 67.69 eV, respectively, at the corresponding optimized octahedral geometry. However, our DF, DFBG, and NR HF calculations for the isomer Sg(OC)6 yield atomization energies of 64.30, 64.77, and 62.62 eV, respectively, at the optimized geometry for this species. The optimized Sg–C and C–O bond distances (in Å) for octahedral Sg(CO)6 using our DF (NR) calculations are 2.15 (2.32) and 1.11 (1.11), respectively. However, the optimized Sg–O and O–C bond distances (in Å) for the isomer octahedral Sg(OC)6 obtained with our DF (NR) calculations are 2.80 (2.73) and 1.10 (1.11), respectively. Our prediction of the greater stability of Sg(CO)6 isomer at both the relativistic (DF and DFBG) and the NR HF levels of theory lends further support to the detection of Sg(CO)6 in the state-of-the-art gas-phase experimental studies of the carbonyl complex of seaborgium reported by Even et al. [Science 345(6203), 1491 (2014)].

Materials Science↗

Multiwall carbon nanotube microcavity arrays

Periodic highly dense multi-wall carbon nanotube (MWCNT) arrays can act as photonic materials exhibiting band gaps in the visible regime and beyond terahertz range. MWCNT arrays in square arrangement for nanoscale lattice constants can be configured as a microcavity with predictable resonance frequencies. Here, computational analyses of compact square microcavities (≈0.8 × 0.8 μm{sup 2}) in MWCNT arrays were demonstrated to obtain enhanced quality factors (≈170–180) and narrow-band resonance peaks. Cavity resonances were rationally designed and optimized (nanotube geometry and cavity size) with finite element method. Series (1 × 2 and 1 × 3) and parallel (2 × 1 and 3 × 1) combinations of microcavities were modeled and resonance modes were analyzed. Higher order MWCNT microcavities showed enhanced resonance modes, which were red shifted with increasing Q-factors. Parallel microcavity geometries were also optimized to obtain narrow-band tunable filtering in low-loss communication windows (810, 1336, and 1558 nm). Compact series and parallel MWCNT microcavity arrays may have applications in optical filters and miniaturized optical communication devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of Hydrocyclone Geometry via Rapid Optimization Based on Computational Fluid Dynamics

Abstract Hydrocyclones exploit density gradients for the centrifugal separation of dispersions in a continuous liquid. Selection of the geometrics for optimal separation is case specific, like the media characteristics. The existing optimization method based on computational fluid dynamics (CFD) provides a powerful analytical tool but requires long computational times. The most common praxis for CFD optimization is via the single‐factor optimization method (SFOM). In this study, a novel approach is presented as an improved rapid optimization method that implements a dynamic‐mesh and user‐defined function optimization method (DUOM). The DUOM adapts the dynamic‐mesh approach from other applications to the optimization analysis of hydrocyclones. The DUOM reduced the computational time by 31.1 %, compared to the SFOM.

Liu, Lin↗

SU-D-BRB-04: Plan Quality Comparison of Intracranial Stereotactic Radiosurgery (SRS) for Gamma Knife and VMAT Treatments

Purpose: To compare treatment plan quality of intracranial stereotactic radiosurgery (SRS) for VMAT (RapidArc) and Gamma Knife (GK) systems. Methods: Ten patients with 24 tumors (seven with 1–2 and three with 4–6 lesions), previously treated with GK 4C (prescription doses ranging from 14–23 Gy) were re-planned for RapidArc. Identical contour sets were kept on MRI images for both plans with tissues assigned a CT number of zero. RapidArc plans were performed using 6 MV flattening-filter-free (FFF) beams with dose rate of 1400 MU/minute using two to eight arcs with the following combinations: 2 full coplanar arcs and the rest non-coplanar half arcs. Beam selection was based on target depth. Areas that penetrated more than 10 cm of tissue were avoided by creating smaller arcs or using avoidance sectors in optimization. Plans were optimized with jaw tracking and a high weighting to the normal-brain-tissue and Normal-Tissue-Objective without compromising PTV coverage. Plans were calculated on a 1 mm grid size using AAA algorithm and then normalized so that 99% of each target volume received the prescription dose. Plan quality was assessed by target coverage using Paddick Conformity Index (PCI), sparing of normal-brain-tissue through analysis of V4, V8, and V12 Gy, and integral dose. Results: In all cases critical structure dose criteria were met. RapidArc had a higher PCI than GK plans for 23 out of 24 lesions. The average PCI was 0.76±0.21 for RapidArc and 0.46±0.20 for GK plans (p≤0.001), respectively. Integral dose and normal-brain-tissue doses for all criteria were lower for RapidArc in nearly all patients. The average ratio of GK to RapidArc plans was 1.28±0.27 (p=0.018), 1.31±0.25 (p=0.017), 1.81±0.43 (p=0.005), and 1.50±0.61 (p=0.006) for V4, V8, and V12 Gy, and integral dose, respectively. Conclusion: VMAT was capable of producing higher quality treatment plans than GK when using optimal beam geometries and proper optimization techniques.

60 APPLIED LIFE SCIENCES↗

The Influence of Linker Geometry on Uranyl Complexation by Rigidly-Linked Bis(3-hydroxy-N-methyl-pyridin-2-one)

A series of bis(3-hydroxy-N-methyl-pyridin-2-one) ligands was synthesized, and their respective uranyl complexes were characterized by single crystal X-ray diffraction analyses. These structures were inspected for high-energy conformations and evaluated using a series of metrics to measure co-planarity of chelating moieties with each other and the uranyl coordination plane, as well as to measure coordinative crowding about the uranyl dication. Both very short (ethyl, 3,4-thiophene and o-phenylene) and very long ({alpha},{alpha}{prime}-m-xylene and 1,8-fluorene) linkers provide optimal ligand geometries about the uranyl cation, resulting in planar, unstrained molecular arrangements. The planarity of the rigid linkers also suggests there is a degree of pre-organization for a planar coordination mode that is ideal for uranyl-selective ligand design. Comparison of intramolecular N{sub amide}-O{sub phenolate} distances and {sup 1}H NMR chemical shifts of amide protons supports earlier results that short linkers provide the optimal geometry for intramolecular hydrogen bonding.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ITER ICRF Antenna Reduced-Scale Mock-up EM Simulations and Comparisons with the Measurements

A reduced-scale mock-up of one ITER ICRF antenna triplet has been recently built, featuring the optimized front-end geometry, an optimized 4-port junction and the implementation of a service stub. Provision is made to adapt the frequency response of the antenna by acting on the 4-port junction arms lengths, the service stub length as well as the position of its inclusion in the circuit. Variable antenna loading is achieved by moving a salted water tank in front of the antenna. A summary of the first measurements carried out on this mockup is reported in a companion paper. The EM simulations of the mock-up are done with CST Microwave Studio registered. The geometry of the mock-up is converted from a CAD file and all essential details are included in the model. S parameters of the mock-up are calculated in a large frequency range covering the ITER ICRF antenna frequency band for different geometries of the mock-up and distances to the load. Results of the simulations and systematic comparisons with the measurements are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimizing RF gun cavity geometry within an automated injector design system

RF guns play an integral role in the success of several light sources around the world, and properly designed and optimized cw superconducting RF (SRF) guns can provide a path to higher average brightness. As the need for these guns grows, it is important to have automated optimization software tools that vary the geometry of the gun cavity as part of the injector design process. This will allow designers to improve existing designs for present installations, extend the utility of these guns to other applications, and develop new designs. An evolutionary algorithm (EA) based system can provide this capability because EAs can search in parallel a large parameter space (often non-linear) and in a relatively short time identify promising regions of the space for more careful consideration. The injector designer can then evaluate more cavity design parameters during the injector optimization process against the beam performance requirements of the injector. This paper will describe an extension to the APISA software that allows the cavity geometry to be modified as part of the injector optimization and provide examples of its application to existing RF and SRF gun designs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Incident beam optics optimization for the single crystal neutron diffractometer Pioneer with a polarized beam option

Pioneer, a next-generation single-crystal neutron diffractometer, is under development for Oak Ridge National Laboratory’s Second Target Station. Designed to address a wide range of scientific questions, Pioneer will deliver homogeneous neutron beams with customizable size and divergence and provide a polarized beam option. This article introduces its incident beam optics, highlighting the optimization methodology and the simulated performance. Pioneer will utilize a modified elliptical-straight guide for neutron transport and deploy slit packages and insertable apertures to control beam size and divergence. The optimized guide geometry matches the optimal-and-full-sample-illumination condition, and the beam control system effectively filters out unwanted neutrons while preserving the desired ones. In addition, we have found that polygon-approximated guides provide satisfactory transport efficiency and beam homogeneity, eliminating the need for truly curved guides. Further, to enhance neutronics performance and reduce cost, the coatings of supermirror elements are individually optimized to the lowest half-integer m-values that are sufficient to deliver the desired neutrons. After evaluating polarizing V-cavities and 3 He spin filters over the default polarized wavelength band of 1.2–5.5 Å, we selected a translatable multichannel polarizing V-cavity as the incident beam polarizer. Strategically placed at a location where the beam divergence is low and a large in-guide gap has negligible impact on transport efficiency, the optimized V-cavity achieves an average P 2 T of ~35%.

47 OTHER INSTRUMENTATION↗

Cherenkov imaging method for rapid optimization of clinical treatment geometry in total skin electron beam therapy

Purpose: A method was developed utilizing Cherenkov imaging for rapid and thorough determination of the two gantry angles that produce the most uniform treatment plane during dual-field total skin electron beam therapy (TSET). Methods: Cherenkov imaging was implemented to gather 2D measurements of relative surface dose from 6 MeV electron beams on a white polyethylene sheet. An intensified charge-coupled device camera time-gated to the Linac was used for Cherenkov emission imaging at sixty-two different gantry angles (1° increments, from 239.5° to 300.5°). Following a modified Stanford TSET technique, which uses two fields per patient position for full body coverage, composite images were created as the sum of two beam images on the sheet; each angle pair was evaluated for minimum variation across the patient region of interest. Cherenkov versus dose correlation was verified with ionization chamber measurements. The process was repeated at source to surface distance (SSD) = 441, 370.5, and 300 cm to determine optimal angle spread for varying room geometries. In addition, three patients receiving TSET using a modified Stanford six-dual field technique with 6 MeV electron beams at SSD = 441 cm were imaged during treatment. Results: As in previous studies, Cherenkov intensity was shown to directly correlate with dose for homogenous flat phantoms (R{sup 2} = 0.93), making Cherenkov imaging an appropriate candidate to assess and optimize TSET setup geometry. This method provided dense 2D images allowing 1891 possible treatment geometries to be comprehensively analyzed from one data set of 62 single images. Gantry angles historically used for TSET at their institution were 255.5° and 284.5° at SSD = 441 cm; however, the angles optimized for maximum homogeneity were found to be 252.5° and 287.5° (+6° increase in angle spread). Ionization chamber measurements confirmed improvement in dose homogeneity across the treatment field from a range of 24.4% at the initial angles, to only 9.8% with the angles optimized. A linear relationship between angle spread and SSD was observed, ranging from 35° at 441 cm, to 39° at 300 cm, with no significant variation in percent-depth dose at midline (R{sup 2} = 0.998). For patient studies, factors influencing in vivo correlation between Cherenkov intensity and measured surface dose are still being investigated. Conclusions: Cherenkov intensity correlates to relative dose measured at depth of maximum dose in a uniform, flat phantom. Imaging of phantoms can thus be used to analyze and optimize TSET treatment geometry more extensively and rapidly than thermoluminescent dosimeters or ionization chambers. This work suggests that there could be an expanded role for Cherenkov imaging as a tool to efficiently improve treatment protocols and as a potential verification tool for routine monitoring of unique patient treatments.

61 RADIATION PROTECTION AND DOSIMETRY↗