Search NASA⌕ Search

SEARCH · Search NASA

Results for “guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

WE-F-201-00: Practical Guidelines for Commissioning Advanced Brachytherapy Dose Calculation Algorithms

With the recent introduction of heterogeneity correction algorithms for brachytherapy, the AAPM community is still unclear on how to commission and implement these into clinical practice. The recently-published AAPM TG-186 report discusses important issues for clinical implementation of these algorithms. A charge of the AAPM-ESTRO-ABG Working Group on MBDCA in Brachytherapy (WGMBDCA) is the development of a set of well-defined test case plans, available as references in the software commissioning process to be performed by clinical end-users. In this practical medical physics course, specific examples on how to perform the commissioning process are presented, as well as descriptions of the clinical impact from recent literature reporting comparisons of TG-43 and heterogeneity-based dosimetry. Learning Objectives: Identify key clinical applications needing advanced dose calculation in brachytherapy. Review TG-186 and WGMBDCA guidelines, commission process, and dosimetry benchmarks. Evaluate clinical cases using commercially available systems and compare to TG-43 dosimetry.

60 APPLIED LIFE SCIENCES↗

WE-F-201-02: Review TG-186 and WGMBDCA Guidelines, Commission Process, and Dosimetry Benchmarks

With the recent introduction of heterogeneity correction algorithms for brachytherapy, the AAPM community is still unclear on how to commission and implement these into clinical practice. The recently-published AAPM TG-186 report discusses important issues for clinical implementation of these algorithms. A charge of the AAPM-ESTRO-ABG Working Group on MBDCA in Brachytherapy (WGMBDCA) is the development of a set of well-defined test case plans, available as references in the software commissioning process to be performed by clinical end-users. In this practical medical physics course, specific examples on how to perform the commissioning process are presented, as well as descriptions of the clinical impact from recent literature reporting comparisons of TG-43 and heterogeneity-based dosimetry. Learning Objectives: Identify key clinical applications needing advanced dose calculation in brachytherapy. Review TG-186 and WGMBDCA guidelines, commission process, and dosimetry benchmarks. Evaluate clinical cases using commercially available systems and compare to TG-43 dosimetry.

60 APPLIED LIFE SCIENCES↗

SU-F-P-54: Guidelines to Check Image Registration QA of a Clinical Deformation Registration Software: A Single Institution Preliminary Study

Purpose: The objective of this study is to verify and analyze the accuracy of a clinical deformable image registration (DIR) software. Methods: To test clinical DIR software qualitatively and quantitatively, we focused on lung radiotherapy and analyzed a single (Lung) patient CT scan. Artificial anatomical changes were applied to account for daily variations during the course of treatment including the planning target volume (PTV) and organs at risk (OAR). The primary CT (pCT) and the structure set (pST) was deformed with commercial tool (ImSimQA-Oncology Systems Limited) and after artificial deformation (dCT and dST) sent to another commercial tool (VelocityAI-Varian Medical Systems). In Velocity, the deformed CT and structures (dCT and dST) were inversely deformed back to original primary CT (dbpCT and dbpST). We compared the dbpST and pST structure sets using similarity metrics. Furthermore, a binary deformation field vector (BDF) was created and sent to ImSimQA software for comparison with known “ground truth” deformation vector fields (DVF). Results: An image similarity comparison was made by using “ground truth” DVF and “deformed output” BDF with an output of normalized “cross correlation (CC)” and “mutual information (MI)” in ImSimQA software. Results for the lung case were MI=0.66 and CC=0.99. The artificial structure deformation in both pST and dbpST was analyzed using DICE coefficient, mean distance to conformity (MDC) and deformation field error volume histogram (DFEVH) by comparing them before and after inverse deformation. We have noticed inadequate structure match for CTV, ITV and PTV due to close proximity of heart and overall affected by lung expansion. Conclusion: We have seen similarity between pCT and dbpCT but not so well between pST and dbpST, because of inadequate structure deformation in clinical DIR system. This system based quality assurance test will prepare us for adopting the guidelines of upcoming AAPM task group 132 protocol.

60 APPLIED LIFE SCIENCES↗

SU-F-T-616: Comparison of Different Techniques Using RTOG0631 Guidelines in Spine SBRT

Purpose: Stereotactic body radiosurgery (SBRT) for spine metastases involves irradiation using a single high dose fraction. The purpose of this study was to investigate a Hybrid VMAT/IMRT technique which combines volumetric modulated arc therapy (VMAT) and intensity modulated radiation therapy (IMRT) for spine SBRT in terms of its dosimetric quality and treatment efficiency using Radiation Therapy Oncology Group (RTOG) 0631 guidelines. Methods: 7 fields IMRT, 2 full arcs VMAT and Hybrid VMAT/IMRT were created for ten previously treated patients. The Hybrid VMAT/IMRT technique consisted of 1 full VMAT arc and 5 IMRT fields. Hybrid VMAT/IMRT plans were compared with IMRT and VMAT plans in terms of the dose distribution, spinal cord sparing, homogeneity, conformity and gradient indexies, monitor unit (MU) and beam on time (BOT). RTOG 0631 recommendations were applied for treatment planning. All plans were normalized and prescribed to deliver 18.0 Gy in a single fraction to 90% of the target volume. Results: The Hybrid VMAT/IMRT technique significantly improved target dose homogeneity and conformity compared with IMRT and VMAT techniques. Providing sharp dose gradient Hybrid VMAT/IMRT plans spare the spinal cord and healthy tissue more effectively. Although, both MU and BOT slightly increased in Hybrid VMAT/IMRT plans there is no statistically meaningful difference between VMAT and Hybrid VMAT/IMRT plans. Conclusion: In IMRT, a smaller volume of healthy tissue can be irradiated in the low dose region, VMAT plans provide better target volume coverage, favorable dose gradient, conformity and better OAR sparing and also they require a much smaller number of MUs and thus a shorter treatment time than IMRT plans. Hybrid plan offers a sinergy through combination of these two techniques with slightly increased number of MU and thus more treatment time.

60 APPLIED LIFE SCIENCES↗

Methodological Guidelines for Accurate Detection of Viruses in Wild Plant Species

Here ecological understanding of disease risk, emergence, and dynamics and of the efficacy of control strategies relies heavily on efficient tools for microorganism identification and characterization. Misdetection, such as the misclassification of infected hosts as healthy, can strongly bias estimates of disease prevalence and lead to inaccurate conclusions. In natural plant ecosystems, interest in assessing microbial dynamics is increasing exponentially, but guidelines for detection of microorganisms in wild plants remain limited, particularly so for plant viruses. To address this gap, we explored issues and solutions associated with virus detection by serological and molecular methods in noncrop plant species as applied to the globally important Barley yellow dwarf virus PAV ( Luteoviridae ), which infects wild native plants as well as crops. With enzyme-linked immunosorbent assays (ELISA), we demonstrate how virus detection in a perennial wild plant species may be much greater in stems than in leaves, although leaves are most commonly sampled, and may also vary among tillers within an individual, thereby highlighting the importance of designing effective sampling strategies. With reverse transcription-PCR (RT-PCR), we demonstrate how inhibitors in tissues of perennial wild hosts can suppress virus detection but can be overcome with methods and products that improve isolation and amplification of nucleic acids. These examples demonstrate the paramount importance of testing and validating survey designs and virus detection methods for noncrop plant communities to ensure accurate ecological surveys and reliable assumptions about virus dynamics in wild hosts.

59 BASIC BIOLOGICAL SCIENCES↗

Two-particle multiplets splitting as a guideline in nucleon pairing estimations

The ground state multiplet structure for nuclei over the wide range of mass number A was calculated in δ-approximation and different mass relations for pairing energy were analysed in this work. Correlation between the calculated multiplet structure and experimental data offers a guideline in deciding between mass relations for nucleon pairing.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Guidelines for Making, Interpreting, and Quantifying Activity Measurements of Molten Salts Containing Mixed Cations and Anions Using Cation-Based Electrodes by Electromotive Force

Measurements of thermochemical properties in molten salt electrolytes with mixtures of cations and anions are difficult to interpret. Electromotive force measurements of salts containing common anions were driven by the least stable anion compound (e.g., LiCl in LiCl-KCl), while measurements in common cation salts were driven by the most noble anion half-cell reaction (e.g., F − /F 2 in LiCl-LiF). Measurements in mixed cation and anion salts were driven by the least stable anion compound for the most noble anion half-cell reaction (e.g., KF in KCl-LiF). These guidelines enable quantification of the activity of electroactive species in salts containing multiple cations or anions.

Lichtenstein, Timothy [Argonne National Laboratory↗

Guideline 36 Savings Calculator v0.1

This software package contains a simple calculator that can be used to estimate savings from implementing a retrofit of HVAC controls to ASHRAE Guideline 36 in a multi-zone office building. Implemented in Excel, the calculator has a user-interface front-end to configure parameters of the case study, such as location, building size, and existing control strategies, and a back-end containing results from a large number of pre-run annual energy simulations. The software package also contains the simulation models and associated pre- and post-processing scripts to generate these results.

Blum, David↗

Radiological Staging for Distant Metastases in Breast Cancer Patients with Confirmed Local and/or Locoregional Recurrence: How Useful are Current Guideline Recommendations?

Background: Breast cancer patients with local and/or locoregional recurrence (LR) are at higher risk of developing distant metastases (DM) at a later time. Once LR has been confirmed, some international interdisciplinary guidelines recommend performing radiological examinations for DM to determine the course of further therapy (curative or palliative approach). This study analyzed the metastatic patterns of patients with LR with particular regard to the frequency of concurrent diagnosis of LR and DM; in other words: are radiological staging procedures actually justified for DM at the time of diagnosis of LR? Methods: This study included all patients (n = 1368) who were diagnosed and treated for nonmetastatic breast cancer (Stage I–III) at the University Women’s Hospital Basel, Switzerland between 1990 and 2009. Results: In 137 patients, LR was diagnosed without a history of DM: in-breast/thoracic wall only, n = 90 (65.7%); involvement of axillary/supra-/infraclavicular lymph nodes, n = 47 (34.3%). DM was found at the time of diagnosis of LR in 44 patients (32.1%). Concurrent diagnosis of LR and DM occurred significantly more often in patients with lymph node recurrence compared with those with in-breast/chest wall recurrence (48.9% vs. 23.3%; p = 0.004). Conclusions: Approximately one-third of patients with a LR had synchronous DM at the time of their local/locoregional event. For this reason, routine systemic staging imaging at the time of LR should be an absolute requirement for planning further therapy. Confirmation of DM may spare the patients radical surgical interventions with questionable impact on survival in the face of an incurable disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design Guidelines for Predicting Stress in Cemented Doublets Undergoing Temperature Change

This work explores quick predictive methods for calculating potentially risky stresses in cemented doublets underdoing temperature change that agree well with finite element analysis. We also provide guidelines for avoiding stress concentrations. Cemented doublets are ubiquitous in the optics world, but it is not always clear if they will perform as intended in a specific thermal environment due to excessive stress. The stress in the optic can cause debonding or even fracture. Yoder addressed this problem using analytical results from Chen and Nelson but also expressed some skepticism as to the accuracy and usefulness of those results. Closed-form analytical solutions are extremely useful when doing trade-off studies to see if a particular geometry or glass choice will cause stress problems. The problem of bonded materials undergoing temperature change is of great interest in the electronics industry, and improved analytical solutions are now available that address the issues raised by Yoder, and they have been validated using finite element analysis (FEA). But the newer solutions still have limitations. The analytical solutions presented here cannot predict stresses due to stress concentrations or singularities at the edge of the bondline—this still has to be done using FEA—although some advanced methods are available. Also, the existing analytical methods assume a flat interface between adjoining elements; they do not account for the effect of curvature. We find that most doublet failures start at the edges and involve debonding of the glass. Glass fracture is rare for doublets, accounting for less than 10% of the failures. This paper provides the reader with a general introduction to a large and dense body of literature in order to demystify the subject of temperature-induced glass bonding failures.

36 MATERIALS SCIENCE↗

Field Demonstration of the Brick Ontology to Scale up the Deployment of ASHRAE Guideline 36 Control Sequences

Many commercial buildings have a vast network of sensors as part of their building automation systems (BAS) that allows opportunities for energy consumption and cost savings by deploying advanced control sequences. However, this resource is often underutilized since BAS are typically programmed with simple control sequences with limited potential to deliver on these opportunities. The recent availability of ASHRAE Guideline 36 (G36) with advanced HVAC control sequences supports control retrofits in existing buildings to unlock much of the savings potential. However, barriers such as the lack of standard naming convention of building assets and data points, proprietary equipment and BAS, and the inherent uniqueness of buildings and their systems prevent building stakeholders from adopting any “plug-and-play” implementation of G36. Instead, control vendors must often undertake the manual and labor-intensive point mapping process to identify a data stream’s functional and spatial relationship within the HVAC system along with other relevant contexts and map it to the new control sequences. The vendor must carry out the point mapping process in each individual building since the mapping is unlikely to port over to another building. Even for the same building, the point mapping process can occur multiple times if various control vendors implement different control retrofits and/or multiple control retrofits happen over the lifecycle of the building. Then, there is the likelihood that G36 control sequences are programmed uniquely to the building, preventing the same implementation from being reused in another. Therefore, this paper presents a field demonstration of how we leveraged the Brick ontology with BACnet, OpenBuildingControl’s Control Description Language (CDL), and open-source support tools to implement scalable and portable advanced building controls. These tools provide standardized semantic descriptions and relationships of the building’s assets and data points (Brick), standardized communication protocol to read from and write to the building’s BAS (BACnet), and standardized code implementations (CDL) of standardized advanced control strategies (G36). We implemented G36’s hot water supply temperature setpoint reset in a Berkeley, CA building for this field demonstration. This field demonstration aims to show how integrating these tools may streamline the deployment of advanced control sequences such as G36 in a consistent manner regardless of differences found across buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Utility-Scale Parabolic Trough Solar Systems: Performance Acceptance Test Guidelines, April 2009 - December 2010

Prior to commercial operation, large solar systems in utility-size power plants need to pass a performance acceptance test conducted by the engineering, procurement, and construction (EPC) contractor or owners. In lieu of the present absence of ASME or other international test codes developed for this purpose, the National Renewable Energy Laboratory has undertaken the development of interimguidelines to provide recommendations for test procedures that can yield results of a high level of accuracy consistent with good engineering knowledge and practice. The Guidelines contained here are specifically written for parabolic trough collector systems with a heat-transport system using a high-temperature synthetic oil, but the basic principles are relevant to other CSP systems.

14 SOLAR ENERGY↗

Strategy Guideline: Advanced Construction Documentation Recommendations for High Performance Homes

As whole house energy efficiency increases, new houses become less like conventional houses that were built in the past. New materials and new systems require greater coordination and communication between industry stakeholders. The Guideline for Construction Documents for High Performance Housing provides advice to address this need. The reader will be presented with four changes that arerecommended to achieve improvements in energy efficiency, durability and health in Building America houses: create coordination drawings, improve specifications, improve detail drawings, and review drawings and prepare a Quality Control Plan.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Air Sealing Mechanical Closets in Slab-On-Grade Homes

This measure guideline describes covers two fundamental retrofit strategies for air sealing around air handling systems that are located within the living space in an enclosed closet: one in which all of the equipment is removed and being replaced, and a closet where the equipment is to remain and existing conditions are sealed. It includes the design and installation details necessary toeffectively seal the air handler closet and central return system to maximize the efficiency and safety of the space conditioning system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strategy Guideline: HVAC Equipment Sizing

This guide describes the equipment selection of a split system air conditioner and furnace for an example house in Chicago, IL as well as a heat pump system for an example house in Orlando, Florida. The required heating and cooling load information for the two example houses was developed in the Department of Energy Building America Strategy Guideline: Accurate Heating and Cooling Load Calculations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Strategy Guideline: High Performance Residential Lighting

The Strategy Guideline: High Performance Residential Lighting has been developed to provide a tool for the understanding and application of high performance lighting in the home. The high performance lighting strategies featured in this guide are drawn from recent advances in commercial lighting for application to typical spaces found in residential buildings. This guide offers strategies togreatly reduce lighting energy use through the application of high quality fluorescent and light emitting diode (LED) technologies. It is important to note that these strategies not only save energy in the home but also serve to satisfy the homeowner's expectations for high quality lighting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measure Guideline: Heat Pump Water Heaters in New and Existing Homes

This Building America Measure Guideline is intended for builders, contractors, homeowners, and policy-makers. This document is intended to explore the issues surrounding heat pump water heaters (HPWHs) to ensure that homeowners and contractors have the tools needed to appropriately and efficiently install HPWHs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗