Search NASA⌕ Search

SEARCH · Search NASA

Results for “heat simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 379 records · Page 21

National energy savings potential of cellular shades: A measurement and simulation study

Windows are major contributors to energy demand in residential homes because of their inferior thermal resistance compared with the opaque envelope, and sometimes from unwanted solar heat gain. Window attachments can help mitigate the energy demand by controlling the solar heat gains and enhancing window thermal resistance. Cellular shades have the potential of superior thermal performance compared with generic shades because of its honeycomb structure. Here, in this study, the team analyzed the energy savings potential of cellular shades in residential homes via experimental testing for two heating seasons and energy simulations. Five shading devices—three single-cell and two double cellular/cell-in-cell shades—were used to compare the performance with generic horizontal venetian blinds using two nearly identical side-by-side rooms in a residential home. The experimental testing showed daily heating energy savings in the range of 17%–36% compared with the case without shades. The experimental testing data also exhibited improvements in thermal comfort when using cellular shades. Additionally, energy simulations were performed to evaluate the energy savings potential of the cellular shades using a residential prototype home, which demonstrated energy savings up to 9 kWh/m2/year in cold climates. The total site energy savings for heating and cooling from cellular shades was up to ~9% for the home with a heat pump and up to ~15% for a home with a gas furnace compared with cases without any shading devices. The energy savings at a national scale were up to 14.6 TWh assuming a 20% penetration rate in residential homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance Assessment of a Dual-purpose HP-TES for a Typical Year Comparing Different Climate Zones

Complete electrification of heating and cooling systems in the United States would overload the existing electrical grid. To this end, recent research efforts have focused on energy storage as one way to reduce ever-increasing peak electricity demands. One such technology is heat pump integrated thermal-energy storage (HP-TES) systems, which can enable load-shifting and reduce demand during peak hours. In this work, a Modelica model of a 4-Ton, dual-mode (heating and cooling) HP-TES system using a room-temperature phase-change material (PCM) integrated through a secondary hydronic loop was developed and simulated for a typical meteorological year in Riverside, CA (ASHRAE Climate Zone 2B), and Chicago, IL (ASHRAE Climate Zone 5A), for a DOE small office prototype building. The COP improvement and demand reduction were analyzed during the time-of-use peak hours along with the required recharge cycle energy demand. A typical summer in Riverside, CA resulted in model-predicted peak COP increases of 50 – 100% compared to the baseline heat pump, especially at higher outdoor temperatures, coupled with maximum peak energy reductions of 22%. During shoulder and winter season simulations, heating energy savings were higher as outdoor temperatures dropped below the PCM phase change temperature. For Chicago, IL, backup heating was necessary to meet the required system capacity for very cold ambient conditions, resulting in winter peak energy savings between 16 – 60% when accounting for backup heating requirements. The recharge energy was found to be mostly below the baseline HP energy during the peak. With improved component selections and controls, the recharge energy may be reduced. The outcomes from the simulations can provide first-order estimates for potential peak energy savings, challenges, and required controls in any location before conducting any field testing.

25 ENERGY STORAGE↗

Coupling subsurface and above-surface models for optimizing the design of borefields and district heating and cooling systems in the presence of varying water-table depth. In: Proceedings, 46th Workshop on Geothermal Reservoir Engineering

Dynamic energy simulation is important for the design and sizing of district heating and cooling systems with geothermal heat exchange. Current modeling approaches in building and district energy simulation tools typically consider heat conduction through the ground between boreholes, without flow of groundwater. On the other hand, detailed simulation tools for subsurface heat and mass transfer exist, but these fall short in simulating above-surface energy systems. To support the design and operation of such systems, we have developed a coupled model including a software package for building and district energy simulation, and software for detailed heat and mass transfer in the ground. For the first, we use the open-source Modelica Buildings Library, which includes dynamic simulation models for building and district energy and control systems. For the heat and mass transfer in the soil, we use the TOUGH simulator. TOUGH can model heat and multi-phase, multi-component mass transport for a variety of fluid systems, as well as chemical reactions, in fractured porous media. In previous work, we described the coupling of these software packages, including how time-dependent boundary conditions for the borehole walls are synchronized for use in Modelica and TOUGH. We verified that the coupled Modelica/TOUGH code produced consistent results with the original Modelica code for an idealized problem in which heat transfer was purely by conduction in a uniform geologic medium. Here, we examine less idealized problems for which TOUGH’s advanced capabilities for modeling fluid flow are required. The first problem has a shallow vadose zone, and the second problem has a thicker vadose zone with a water-table depth that varies in time, which requires a fine vertical grid discretization for the TOUGH model.

Doughtry, Christine↗

Incorporating two-dimensional conduction modeling techniques into an energy simulation program: The EnergyPlus radiant system example

Due to the inherent complexity of multi-dimensional solutions for transient conduction in a multilayered building element, most heat balance-based algorithms assume that conduction occurs only in one dimension—through the building element between the inside and outside environments. Usually, since the length and width of the elements are much greater than the thickness of the element, this is a valid assumption. However, there are some cases such as hydronic radiant slabs where this assumption may not lead to an accurate estimate of the energy consumption of the system. In a hydronic radiant slab, water tubes are embedded in a slab, and hot or chilled water is circulated to meet any heating or cooling loads. The energy consumption of such a system will depend highly on the temperature of the water being sent to the slab (i.e., produced by the boiler or chiller). The temperature of the water that must be sent to the slab will depend on the spacing of the tubes, the multilayer construction of the building element, and the boundary conditions to which the construction is exposed. Thus, to accurately predict the energy consumption of such a system, a transient two-dimensional heat conduction model must be integrated with a heat balance-based simulation. This paper demonstrates the potential loss of accuracy associated with the one-dimensional radiant system models by providing a comparison of one- and two-dimensional solutions using EnergyPlus.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of a multi-layer canopy model for E3SM Land Model with support for heterogeneous computing

The vertical structure of vegetation canopies creates micro-climates. However, the land components of most Earth System Models, including the Energy Exascale Earth System Model (E3SM), typically neglect vertical canopy structure by using a single layer big-leaf representation to simulate water, CO 2 , and energy exchanges between the land and the atmosphere. In this study, we developed a Multi-Layer Canopy Model for the E3SM Land Model to resolve the micro-climate created by vegetation canopies. The model developed in this study re-implements the CLM-ml_v1 to support heterogeneous computing architectures consisting of CPUs and GPUs and includes three additional optimization-based stomatal conductance models. The use of Portable, Extensible Toolkit for Scientific Computation provides a speedup of 25–50 times on a GPU relative to a CPU. The numerical implementation of the model was verified against CLM-ml_v1 for a month-long simulation using data from the Ameriflux US-University of Michigan Biological Station site. Model structural uncertainty was explored by performing control simulations for five stomatal conductance models that exclude and include the control of plant hydrodynamics (PHD) on photosynthesis. The bias in simulated sensible and latent heat fluxes was lower when PHD was accounted for in the model. Additionally, six idealized simulations were performed to study the impact of three environmental variables (i.e. air temperature, atmospheric CO 2 , and soil moisture) on canopy processes (i.e. net CO 2 assimilation, leaf temperature, and leaf water potential). Increasing air temperature reduced net CO 2 assimilation and increased air temperature. Net CO 2 assimilation increased at higher atmospheric CO 2 , while decreasing soil moisture resulted in lower leaf water potential.

54 ENVIRONMENTAL SCIENCES↗

High Efficiency Heat Pumps Can Pave the Path for Building Decarbonization in Cold Climates: Preprint

Heat pumps play an instrumental role in buildings decarbonization strategies. Recent advances in heat pump systems employ variable-speed compressor technology and electronically commutated fan motors. Inherently, the heating capacity and efficiency of heat pumps decrease with falling outdoor temperatures. Compared to single-speed heat pumps, variable speed systems can maintain higher heating and cooling efficiencies over a wider range of outdoor temperatures. The goal of this multi-phase project was to determine the energy savings of a high efficiency, variable-speed, air-source, split system heat pump designed for cold climate applications. The first project phase was to evaluate the performance of the heat pump in the laboratory under varying outdoor conditions in heating and cooling modes. The second phase was to translate the laboratory-measured performance into lookup tables for EnergyPlus hourly building simulation engine. Then, two sets of annual building simulations were performed using typical meteorological year weather from the Chicago-O'Hare airport for three different building types (a single-family residence, a strip mall, and a low-rise office building). The first set simulated a standard efficiency heat pump while the second set utilized the phase two performance tables to model a high efficiency heat pump. The high efficiency heat pump produced significant annual heating energy savings in all three buildings. The variable speed compressor and fan control also contributed to cooling energy savings. The simulated annual energy savings ranged from 22% to 35% over their respective baseline. The project's findings helped a Midwest electric utility, Commonwealth Edison (ComEd), design new incentives around high efficiency heat pumps.

cold climate heat pump↗

BISON Simulated and Experimental Fission Product Release Comparisons from Reradiated AGR-3/4 Compacts During High Temperature Heating Tests

The fuel performance modeling code BISON was used to predict the release of fission products iodine-131 (131I), xenon-133 (133Xe), and krypton-85 (85Kr) from four re-irradiated AGR-3/4 fuel compacts containing tristructural isotropic (TRISO) coated particles during high-temperature isothermal heating tests. The AGR-3/4 fuel compacts were irradiated in the Advanced Test Reactor (ATR) as part of the third and fourth series of planned experiments to support the Advanced Gas Reactor (AGR) Program. They were subsequently stored and re-irradiated in the Neutron Radiography (NRAD) reactor for approximately five days and then stored for another five to eight days before being subjected to isothermal heating tests in the Fuel Accident Condition Simulation (FACS furnace) for 200 to 300 hours at temperatures between 1000°C and 1600°C to evaluate fission product release at elevated temperatures. New nuclide-specific fission product source term models for the three nuclides of interest were developed using the reactor multiphysics code Griffin and implemented into BISON to support this work. The new source term models were incorporated into coupled compact- and particle-scale BISON simulations, which predict spatially- and temporally-resolved radionuclide generation, radioactive decay, transport, and release throughout the entire irradiation history, including the initial ATR irradiation, NRAD re-irradiations, FACS heating tests, and intermediate periods spent in storage. The experimentally measured fission product release from the heating tests were compared to modeling release predictions calculated by BISON to evaluate how well the code compares to experimental results. Overall, the experimental measured and BISON predicted comparative release results varied but generally agreed to within 5 particle equivalents. Comparative release results identified general observations to take into consideration to help refine future models and reduce uncertainties associated with both the measurement results and predictive results. This includes developing new uranium oxycarbide (UCO) specific kernel diffusivities for the three isotopes examined to more accurately reflect the material properties of the fuel form. Deriving new diffusivities will aid in producing a more informed BISON model

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Fokker-Planck simulations of fast ion ICRF and electron EC heating in a mirror plasma using CQL3D-m

The CQL3D-m continuum bounce-average Fokker-Planck code is adapted for magnetic mirror plasmas [1] and is now routinely used in no-free-parameter classical integrated modeling of mirror devices [2, 3]. In the present effort, we report on two RF methods of plasma heating in mirror machine. The fast ions (FI) are heated by Fast waves at 2nd-4th harmonic, where FIs originate from neutral beam injection at 45 degrees to the magnetic field. The scenario shows an efficient ion heating near the FI bouncing point. The electrons are heated by X-mode launched from the high magnetic field side towards the resonance. Different from the tokamak applications, CQL3D-m provides an evolving self-consistent ambipolar parallel electric field, which determines the shape of the loss cone and hence an accurate confinement time of both ions and electrons. Also, it includes a description of ion and electron sources and sinks (related to charge exchange and impact ionization) which are updated at every time step. CQL3D-m utilizes a fully nonlinear Coulomb collision operator that is important for the significantly non-Maxwellian ion distributions typically established in mirror plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Critical heat flux on zircaloy and accident tolerant fuel cladding under prototypical conditions of pressurized and boiling water reactors

First of a kind high spatial and temporal resolution temperature measurements of Pressurized Water Reactor and Boiling Water Reactor simulated fuel pins (high heat flux cosine profile heaters) in annular rod type geometry during nucleate boiling, departure from nucleate boiling and re-wetting has been performed. Distributed fiber optic measurements of the cladding axial temperature with spatial resolutions down to 2.5 mm axially at up to three equally spaced azimuthal locations per rod have demonstrated the similarities and differences of the different accident tolerant fuel cladding materials. These experiments show the performance of accident tolerant cladding with a precise measurement of the location and evolution of dryout followed by the re-wetting phenomena (see supplementary time history of a critical heat flux event). Experimental parameters varied coolant mass fluxes from 1695 to 2712 kg/m 2 s, pressures from 10 to 20 MPa, and inlet subcooling from 10 to 55 °C. It was found that the coatings and different material have little effect on the value of the critical heat flux. Any discrepancies between the local critical heat flux verified among the cladding material are attributed to different departure from nucleate boiling phenomena captured during the experiment with the high-resolution optical fiber temperature data. Substantial differences in the performance of the different cladding material to survive a critical heat flux event were however observed by post-test X-ray and optical inspection. External evident damage and internal cracks to the simulated fuel pin having the bare zircaloy cladding were observed in regions associated with the occurrence of the critical heat flux for longer periods. Such damages were associated with zirconium oxidation, and not noticed on the Cr coated zircaloy or FeCrAl claddings. These results indicate that the use of FeCrAl or a Cr coated zircaloy as cladding in Pressurized Water Reactor and Boiling Water Reactor may increase the survivability of the cladding material for short transients.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Selective Thermal Emission with Radiation and Adsorption in Annuli (STERADIAN): An Advanced Heat Exchanger Concept for Supercritical CO 2 Power Cycles

One of the key limitations affecting ability to achieve the efficiency and cost saving advantages of a supercritical CO 2 (scCO 2 ) power cycle resides with the primary heat exchanger where costs can exceed 50% of the plant capital budget depending on design. This project established the foundational groundwork for a new type of heat exchanger optimized to take advantage of radiative heat transfer to scCO 2 . Selective thermal emission coatings were designed and tested that radiated more light tuned to the 4.2 µm infrared absorption band of CO 2 . Coating design utilized principles of nanophotonic bandgap theory to design a selective emitter that has: 1) low emissivity in the visible band, 2) near 100% effective emissivity in the mid-IR wavelength between 4 and 4.5 µm wavelength, and 3) strong suppression of far-IR light emission that will maximize radiative heat transfer efficiency to scCO 2 . Computational fluid dynamics simulations show that an advanced heat exchanger implementing this selective thermal emitter coating is 25 to as much as 40% smaller than conventional heat exchanger designs.

14 SOLAR ENERGY↗

Optimization of District Heating Network Parameters in Steady-State Operation

Here we examine the modeling, simulation, and optimization of district heating systems, which are widely used for thermal transport using steam or hot water as a carrier. We propose a generalizable framework to specify network models and scenario parameters, and develop an optimization method for evaluating system states including pressures, fluid flowrates, and temperatures throughout the network. The network modeling includes pipes, thermal plants, pumps, and passive or controllable loads as system components. We propose basic models for thermodynamic fluid transport and enforce the balance of physical quantities in steady-state flow over co-located outgoing and return networks. We formulate an optimization problem with steam and hot water as the outgoing and return carriers, as in legacy twentieth century systems. The physical laws and engineering limitations are specified for each component type, and the thermal network flow optimization problem is formulated and solved for a realistic test network under several scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CFD simulations of electric motor end ring cooling for improved thermal management

Proper thermal management of an electric motor for vehicle applications extends its operating range. One cooling approach is to impinge Automatic Transmission Fluid (ATF) onto the rotor end ring. Increased ATF coverage correlates to enhanced heat transfer. Computational Fluid Dynamics (CFD) analytical tools provide a mechanism to assess motor thermal management prior to hardware fabrication. The complexity of the fluid flow (e.g., jet atomization, interface tracking, wall impingement) and heat transfer makes these simulations challenging. Computational costs are high when solving these flows on high-speed rotating meshes. Typically, a Volume-of Fluid (VOF) technique (i.e., two-fluid system) is used to resolve ATF dynamics within this rotating framework. Suitable numerical resolution of the relevant physics for thin films under strong inertial forces at high rotor speeds is computationally expensive, further increasing the run times. In this work, a numerical study of rotor-ring cooling by ATF is presented using a patent automated Cartesian cut-cell based method coupled with Automatic Mesh Refinement (AMR). This approach automatically creates the Cartesian mesh on-the-fly and can effectively handle complex rotating geometries by adaptively refining the mesh based on local gradients in the flow field which results in better resolution of the air-ATF interface. A Single non-inertial Reference Frame (SRF) approach is used to account for the rotating geometry and to further improve the overall computational efficiency. Quasi-steady state conditions are targeted in the analysis of the results. Important physics such as ATF jet structure, velocity detail near the air-jet interface, ATF coverage/accumulation on the ring surface, and cooling capacity are presented for a low-resolution Reynolds averaged Navier-Stokes (RANS), high-resolution RANS, and high-resolution Large-Eddy Simulation (LES) models. Computations are scaled over hundreds of cores on a supercomputer to maximize turnaround time. Each numerical approach is shown to capture the general trajectory of the oil jet prior to surface impingement. The high-resolution LES simulation, however, is superior in capturing small scale details and heat transfer between the free jet and surrounding air.

42 ENGINEERING↗

Time-Dependent 600 °C Post-Weld Heat Treatment Response of Laser-Wire-Directed Energy Deposited Austenitic Stainless Steel Claddings on Carbon Steel

Austenitic stainless steel overlay claddings are often used to protect nuclear reactor pressure vessels from corrosion. Arc welding processes are traditionally employed, which require a high heat input to bond the dissimilar metals, creating a large heat-affected zone and high residual stress that demands a lengthy stress-relieving post-weld heat treatment, up to 48 hours. High energy beam (e.g., laser, electron beam) directed energy deposition-based overlay cladding processes show promise for fabricating claddings with superior performance compared to arc welded ones because of their localized heat input; however, their necessity and time of post-weld heat treatment are currently unclear. In this research, we investigate the time dependence of a 600 C stress-relieving post-weld heat treatment of austenitic stainless steel clad on low carbon steel by laser-wire-directed energy deposition, comparing the microstructure and mechanical properties of the as-fabricated condition to 2-, 10-, and 48-hour heat treatment times. Diffusion simulations and microscopy show a gradual carburization of the stainless steel cladding and decarburization of the heat-affected zone/base metal. Nanoindentation testing shows up to a 1.8–2.69 embrittlement in the cladding and a 0.33 to 0.69 softening in the heat-affected zone after the 48-hour post-weld heat treatment. Tensile testing of the cladding composites reveals that increasing post-weld heat treatment time raises clad cracking susceptibility due to intergranular carbide formation and shows that laser-wire-directed energy deposition claddings may not require post-weld heat treatment.

Coating↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

Oilwell Conversion (Well API 121913310501) to Geothermal Heat Storage Well for Flexible Electricity Storage

Geothermal growth is limited by a lack of geographically dispersed high-temperature thermal resources and high initial upfront investment in characterization and well construction. This project intended to address the challenges of energy supply intermittency and enhance grid resilience, reliability, and energy security by storing energy provided from currently available renewable resources in the subsurface to harvest it a later time during at-peak energy demand. This project intended to improve geothermal adoption, reduce initial project risk, and improve price competitiveness through utilizing existing oil and gas infrastructure such as non-productive wells, non-economic fields, dry holes, and orphaned wells. The project also intended to address the lack of geographically dispersed thermal resources and enhance grid resilience, reliability, and energy security by introducing an economical method for storing energy from currently available renewable resources in the subsurface for usage during at-peak energy demand. During this research, the project furthered the understanding of the feasibility of utilizing abandoned oil and gas wells as geothermal heat storage wells. The project team investigated the heat storage and hydrogeological characteristics of subsurface reservoirs in the Illinois Basin to evaluate their response to heat injection for determining the evolution of temperature profiles and heat losses over time using existing and available data sets. The project team then performed modeling and simulation to evaluate the heat losses of returning fluids during heat extraction. The outputs were used to select an optimal candidate reservoir and location in Southern Illinois. The team designed and performed a small-scale field test in an existing oil well to refine the model and to demonstrate the permitting and regulatory pathways necessary for the conversion of oil and gas assets to geothermal use. The field test also serves as a proof of concept and can guide the procedures for future research and implementation. Additionally, the project team, conducted initial market research and customer discovery to develop a go to market strategy for an Advanced Geothermal Energy Storage (AGES) system. The project team in this research also identified the parameters to be refined in future research, to improve the current go to market strategy economic model. To this end several subject matter experts were also identified to assist in future research with geothermal infrastructure setup, energy storage policy and law, energy storage market demand, potential siting based on demand etc. Future research will involve further sophistication of the site commercial modeling, implementing a larger-scale test, and further refinement of the thermodynamic modeling/simulation process. The output will be lifecycle costs and economics suitable for comparison to alternative approaches from a validated full-scale demonstration for venture capital investment into this technology. The project successfully demonstrated the ability to leverage existing oilfield infrastructure, permits, and land access and leasing agreements, to enable geothermal storage projects to come online faster and cheaper than a greenfield development could. This technology could allow for greater energy independence and security through long-term energy storage solutions. The longer duration allows for greater storage for renewables currently limited by hours-long storage durations of lithium-ion. The AGES system would support the growth of renewable energy farms, and provide greater opportunities for a cleaner energy infrastructure.

15 GEOTHERMAL ENERGY↗